• Title/Summary/Keyword: critical shear stress for deposition

Search Result 7, Processing Time 0.024 seconds

An Experimental Study on Erosion and Deposition of Estuarial Cohesive Sediment (하구점성토의 침식 및 퇴적에 관한 실험적 연구)

  • 안수한;김재중
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.1 no.1
    • /
    • pp.44-49
    • /
    • 1989
  • Cohesive sedimentation mechanism is affected by various physico-chemical factors. Thus, the field observations and the laboratory experiments for cohesive sediment have been reported for decades. Erosion and deposition test was carried out with cohesive sediment material sampled in the Keum River Estuary in this study. The change of the suspended cohesive sediment concentration was measured for various flow conditions, which have the purpose to determine the critical shear stress and the coefficients for erosion and deposition . The critical shear stress and the coefficient for erosion were determined in the flume test. The equilibrium concentration was determined for each shear stress and the relationship between the normalized equilibrium cocentration with the initial cocentration (Ceq/co) and the equivalent shear stress was obtained. The experimental results were compared with the other results and showed fairly well agreements with them.

  • PDF

The Laboratory Study on Estimation of Depositional Properties of Kaolinite Sediments on Saltwater Condition (염도 존재시 고령토 퇴적물의 퇴적특성 산정에 관한 실험적 연구)

  • Hwang, Kyu-Nam;Kim, Nam-Hun;Lee, Yong-Hao
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.9
    • /
    • pp.863-872
    • /
    • 2008
  • In this study, a series of deposition tests have been conducted on saltwater condition(salinity 32 %o) using an annular flume, in order to estimate depositional properties of kaolinite sediments and to analyze the effect of the initial concentration on them. Total 37 deposition tests have been carried out in three different initial concentrations (1000, 5000, 15000 ppm) with varying the bed shear stress. From these test results, minimum shear stress (or critical shear stress for deposition; ${\tau}_{bmin}$) and the deposition rate parameters (${\sigma}_1,\;({\tau}^*_b-1)_{50},\;{\sigma}_2,\;t_{50}$) for kaolinite sediments have been quantified, and the effects of the initial concentration and salinity on depositional properties of cohesive sediments have been analyzed qualitatively. As the results, ${\tau}_{bmin},\;{\sigma}_1\;and\;({\tau}^*_b-1)_{50}$ are found to be 0.147, 0.74 and $0.65N/m^2$ respectively. Through comparing with results from previous studies, the performance of this study and tests results are shown to be good enough to verify.

Laboratory Study on the Settling Properties of Silty Mud (실트질 점토의 심강(沈降) 특성(特性)에 관한 연구)

  • Kim, Cha Kyum;Lee, Jong Sup
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.3
    • /
    • pp.85-93
    • /
    • 1991
  • To investigate the effect of the initial sediment concentration ($C_o$) and bed shear stress (${\tau}_b$) on the settling properties of silty mud, deposition experiments were conducted in a recirculating flume using silty mud sediment taken from the Youngkwang coast which is located in the eastern Yellow Sea. The relative concentration, $C/C_o$ (C=depth averaged concentration), and the relative equilibrium concentration, $C_{eq}/C_o$ ($C_{eq}$=depth averaged concentration in the equilibrium state), have been found to depend much more strongly on the bed shear stress than initial concentration, and to increase with increasing bed shear stress. The minimum value. ${\tau}_{bmin}$, and maximum value. ${\tau}_{bmax}$, of critical bed shear stress for deposition of the Youngkwang sediment were deduced to be $0.017N/m^2$ and $1.25N/m^2$, respectively, and these values depend strongly on the properties of sediment (grain size and mineralogy). Formulas for the relative concentration and apparent median settling velocity in the range of ${\tau}_b{\geq}{\tau}_{bmin}$ were deduced. The apparent median settling velocity was found to depend much more strongly on the bed shear stress than the initial concentration and to decrease exponentially with increasing bed shear stress.

  • PDF

Characteristics of Undrained Static Shear Behavior for Sand Due to Aging Effect (Aging 효과에 따른 모래의 비배수 정적전단거동 특성)

  • 김영수;김대만
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.6
    • /
    • pp.137-150
    • /
    • 2004
  • Aging effect of sands showed insignificant result in comparison with that of clay, so that it has not been studied so far. But, as penetration resistance increase has been observed with the lapse of time after deposition and disturbance, aging effect of sands has been actively investigated by field tests, and recently many researchers are performing not oかy field tests but also laboratory tests on sands, so aging effects of sands have been also examined by laboratory tests. In this study, to observe the aging effect of undrained static shear behavior for Nak-Dong River sand, undrained static triaxial tests were performed with changing relative density$(D_r)$, consolidation stress ratio$(K_c)$, and consolidation time. These tests showed that modulus within elastic section increased as consolidation time increased, and in addition, phase transformation point strength$(S_{PT})$ and critical stress ratio point strength $(S_{CSR})$ also increased. But pore water pressure ratio$(u/{p_c}')$ decreased as consolidation time increased, so with this various result, aging effect of static shear for sands can be observed as well.

Estimating Critical Stream Power by the Distribution of Gravel-bed Materials in the Meandering River (만곡하천의 자갈하상재료 분포에 따른 한계수류력 평가)

  • Shin, Seung-Sook;Park, Sang-Deok;Lee, Seung-Kyu;Ji, Min-Gyu
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.2
    • /
    • pp.151-163
    • /
    • 2012
  • The distribution of gravel-bed materials in mountainous river is formed by the process of deposition and transportation of sediment responding to stream power of the latest flood that is over the certain scale. The particle size of bed material was surveyed in the longitudinal points of river and detail points of a specific meandering section and used to estimate the critical velocity and stream power. Yang's critical unit stream power and Bagnold's critical stream power for gravel-bed materials increased with the distance from downstream to upstream. Dimensionless shear stress based on the designed flood discharge in Shields diagram was evaluated that the gravel-bed materials in most survey points may be transported as form of bedload. The mean diameter in the meandering section was the biggest size in first water impingement point of inflow water from upstream and the second big size in second water impingement point by reflection flow. The mean diameters were relatively the small sizes in points right after water impingement. The range of mean critical velocity was 0.77~2.60 m/s and critical unit stream power was big greatly in first water impingement point. The distribution of critical stream power, range of 7~171 $W/m^2$, was shown that variation in longitudinal section was more obvious than that of cross section and estimated that critical stream power may be affected greatly in first and second water impingement point.

Two-dimensional Numerical Simulation of Rainfall-induced Slope Failure (강우에 의한 사면붕괴에 관한 2차원 수치모의)

  • Regmi, Ram Krishna;Jung, Kwan-Sue;Lee, Gi-Ha
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.34-34
    • /
    • 2012
  • Heavy storms rainfall has caused many landslides and slope failures especially in the mountainous area of the world. Landslides and slope failures are common geologic hazards and posed serious threats and globally cause billions in monetary losses and thousands of casualies each year so that studies on slope stability and its failure mechanism under rainfall are being increasing attention of these days. Rainfall-induced slope failures are generally caused by the rise in ground water level, and increase in pore water pressures and seepage forces during periods of intense rainfall. The effective stress in the soil will be decreased due to the increased pore pressure, which thus reduces the soil shear strength, eventually resulting in slope failure. During the rainfall, a wetting front goes downward into the slope, resulting in a gradual increase of the water content and a decrease of the negative pore-water pressure. This negative pore-water pressure is referred to as matric suction when referenced to the pore air pressure that contributes to the stability of unsaturated soil slopes. Therefore, the importance is the study of saturated unsaturated soil behaviors in evaluation of slope stability under heavy rainfall condition. In an actual field, a series of failures may occur in a slope due to a rainfall event. So, this study attempts to develop a numerical model to investigate this failure mechanism. A two-dimensional seepage flow model coupled with a one-dimensional surface flow and erosion/deposition model is used for seepage analysis. It is necessary to identify either there is surface runoff produced or not in a soil slope during a rainfall event, while analyzing the seepage and stability of such slopes. Runoff produced by rainfall may result erosion/deposition process on the surface of the slope. The depth of runoff has vital role in the seepage process within the soil domain so that surface flow and erosion/deposition model computes the surface water head of the runoff produced by the rainfall, and erosion/deposition on the surface of the model slope. Pore water pressure and moisture content data obtained by the seepage flow model are then used to analyze the stability of the slope. Spencer method of slope stability analysis is incorporated into dynamic programming to locate the critical slip surface of a general slope.

  • PDF

Hydraulic Stability Examination of Rainwater Reservoir Pipe Network System on Various Inflow Conditions (유입량 변화에 따른 도심지 내 우수저류조 관망시스템의 안정성 검토)

  • Yoo, Hyung Ju;Kim, Dong Hyun;Maeng, Seung Jin;Lee, Seung Oh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.4
    • /
    • pp.1-13
    • /
    • 2019
  • Recently, as the occurrence frequency of sudden floods due to climate change increased, it is necessary to install the facilities that can cope with the initial stormwater. Most researches have been conducted on the design of facilities applying the Low Impact Development (LID) and the reduction effect on rainfall runoff to examine with 1D or 2D numerical models. However, the studies on the examination about flow characteristics and stability of pipe network systems were relatively insufficient in the literature. In this study, the stability of the pipe network system in rainwater storage tank was examined by using 3D numerical model, FLOW-3D. The changes of velocity and dynamic pressure were examined according to the number of rainwater storage tank and compared with the design criteria to derive the optimal design plan for a rainwater storage tank. As a results of numerical simulation with the design values in the previous study, it was confirmed that the velocity became increased as the number of rainwater storage tank increased. And magnitude of the velocity in pipes was formed within the design criteria. However, the velocity in the additional rainwater storage pipe was about 3.44 m/s exceeding the allowable range of the design criteria, when three or more additional rainwater storage tanks were installed. In the case of turbulence intensity and bottom shear stress, the bottom shear stress was larger than the critical shear stress as the additional rainwater storage was increased. So, the deposition of sediment was unlikely to occur, but it should be considered that the floc was formed by the reduction of the turbulence intensity. In addition, the dynamic pressure was also satisfied with the design criteria when the results were compared with the allowable internal pressure of the pipes generally used in the design of rainwater storage tank. Based on these results, it was suitable to install up to two additional rainwater storage tanks because the drainage becomes well when increasing of the number of storage tank and the velocity in the pipe becomes faster to be vulnerable to damage the pipe. However, this study has a assumption about the specifications of the rainwater storage tanks and the inflow of stormwater and has a limitation such that deriving the suitable rainwater storage tank design by simply adding the storage tank. Therefore, the various storage tank types and stormwater inflow scenarios will be asked to derive more efficient design plans in the future.