• Title/Summary/Keyword: critical deposition stress

Search Result 22, Processing Time 0.021 seconds

Effects of Additives on the Characteristics of Sodium Borosilicate Thin Film Fabricated by AFD Method (첨가제가 AFD법에 의해 제조된 광소자용 Sodium Borosilicate 박막의 물성에 미치는 영향)

  • Chung, Hyung-Gon;Chun, Young-Yun;Mun, Jong-Ha;Chung, Suck-Jong;Lee, Hyung-Jong
    • Korean Journal of Materials Research
    • /
    • v.8 no.8
    • /
    • pp.693-698
    • /
    • 1998
  • The effects of $AI_{2}$$O_{3}$ and the ratio of $Na_2O/B_2O_3$ on the phase separation and optical properties of sodium borosilicate glass film fabricated by AFD(Aerosol Flame Deposition) were investigated. When AI,O, of 6wt% was added to $66SiO_2-27B_2O_3-7Na_2O$ the clear glass film without any crystallization was produced under air-quenching condition after consolidation. As the amount of $AI_{2}$$O_{3}$ increased from 1.5 to 6.0 wt% the refractive index linearly increased from 1.4610 to 1.4701, and the difference of TE and TM mode causing by residual stress in film increased gradually. However, the difference of TE and TM mode to reveal birefringence could be minimized by annealing below the glass transition temperature after consolidation and air quenching. On the other hand. as the ratio of $Na_2O/B_2O_3$ increased the refractive index and birefringence of glass film tended to increase, but the measurement of their values were not available at over the critical ratio of $Na_2O/B_2O_3$, because of the cloudiness due to crystallization. The phase separation was greatly accelerated with increasing the ratio of $Na_2O/B_2O_3$.

  • PDF

Hydraulic Stability Examination of Rainwater Reservoir Pipe Network System on Various Inflow Conditions (유입량 변화에 따른 도심지 내 우수저류조 관망시스템의 안정성 검토)

  • Yoo, Hyung Ju;Kim, Dong Hyun;Maeng, Seung Jin;Lee, Seung Oh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.4
    • /
    • pp.1-13
    • /
    • 2019
  • Recently, as the occurrence frequency of sudden floods due to climate change increased, it is necessary to install the facilities that can cope with the initial stormwater. Most researches have been conducted on the design of facilities applying the Low Impact Development (LID) and the reduction effect on rainfall runoff to examine with 1D or 2D numerical models. However, the studies on the examination about flow characteristics and stability of pipe network systems were relatively insufficient in the literature. In this study, the stability of the pipe network system in rainwater storage tank was examined by using 3D numerical model, FLOW-3D. The changes of velocity and dynamic pressure were examined according to the number of rainwater storage tank and compared with the design criteria to derive the optimal design plan for a rainwater storage tank. As a results of numerical simulation with the design values in the previous study, it was confirmed that the velocity became increased as the number of rainwater storage tank increased. And magnitude of the velocity in pipes was formed within the design criteria. However, the velocity in the additional rainwater storage pipe was about 3.44 m/s exceeding the allowable range of the design criteria, when three or more additional rainwater storage tanks were installed. In the case of turbulence intensity and bottom shear stress, the bottom shear stress was larger than the critical shear stress as the additional rainwater storage was increased. So, the deposition of sediment was unlikely to occur, but it should be considered that the floc was formed by the reduction of the turbulence intensity. In addition, the dynamic pressure was also satisfied with the design criteria when the results were compared with the allowable internal pressure of the pipes generally used in the design of rainwater storage tank. Based on these results, it was suitable to install up to two additional rainwater storage tanks because the drainage becomes well when increasing of the number of storage tank and the velocity in the pipe becomes faster to be vulnerable to damage the pipe. However, this study has a assumption about the specifications of the rainwater storage tanks and the inflow of stormwater and has a limitation such that deriving the suitable rainwater storage tank design by simply adding the storage tank. Therefore, the various storage tank types and stormwater inflow scenarios will be asked to derive more efficient design plans in the future.