• Title/Summary/Keyword: critical current ratio

Search Result 174, Processing Time 0.028 seconds

The Preparation of Bi-2223 Superconducting Powder and Tape by Emulsion Drying Method (에멀젼 건조법에 의한 Bi-2223 초전도 분말과 테이프 제조)

  • 장중철;이응상;이희균;홍계원
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.2
    • /
    • pp.115-122
    • /
    • 1997
  • The powder preparation by using emulsion drying method, one of the chemical powder fabrication methods has the advantages; easy to control the chemical stoichiometry and to fabricate homogeneously fine particles. In the present study, the initial morphology and size distribution of the powder fabricated by using emulsion dry-ing method were controlled and were improved the homogeneity. By carefully controlling the mixing ratio of oil phase and aqueous solution and surfactant of preventing emulsion separation, the Bi(Pb)-Sr-Ca-Cu-O su-perconducting powders were prepared. The properties of the superconducting powder fabricated by this method and the microstructures and superconducting properties of the pelletized samples were investigated. The microstructures and electric properties of the tapes prepared by oxide powder-in-tube method were in-vestigated. The fabricated powder was spherical with less than 1$\mu$m but most of them was agglomerated with 2~5$\mu$m in size. The critical temperature of the pelletized sample annealed at 84$0^{\circ}C$ for 72 hours in oxygen par-tial pressure of 1/13atm in Ar atmosphere was 108K. And the critical current of the first and second annealed tapes in air prepared by oxide powder-in-tube process were 0.4A and 1.5A, respectively.

  • PDF

A Study on Appropriate Nurse Staffing Levels in Intensive Care Units and Improvement of the Critical Care Nursing Fee Schedules (중환자실 적정 간호사 배치수준과 간호관리료 차등제 개선 연구)

  • Lee, Hyo Jin;Cho, Sung-Hyun;Shim, Mi Young;Kim, Jung Yeon;Song, Yu Gil;Kim, Jin;Kim, Young Sam
    • Journal of Korean Clinical Nursing Research
    • /
    • v.29 no.3
    • /
    • pp.312-326
    • /
    • 2023
  • Purpose: This study attempted to analyze the staffing level and critical care nursing fees of intensive care units at tertiary and general hospitals and to provide a professional judgment-based recommendation on staffing level and critical care nursing fee schedules. Methods: Staffing grades and critical care nursing fee schedules for the first quarter of 2017~2020 and the fourth quarter of 2020~2022 were analyzed. A survey was conducted on nursing managers and nurses about the current and appropriate staffing levels. A total of 77 nurse managers and 708 nurses working in Intensive Care Unit(ICU)s at tertiary and general hospitals participated in the study. Results: Grade 1 staffing increased from 25.6% in 2017 to 92.1% in 2022 at tertiary hospitals and from 0.8% in 2017 to 28.4% in 2022 at general hospitals. The current staffing ratios of tertiary and general hospitals were 1:2.21 and 1:2.77, respectively. The appropriate staffing ratio according to nurse managers and nurses was 1:1.00 in patients with more than a ventilator application and 1:2.00 in patients without any ventilator application in tertiary hospitals, and it was 1:1.25 in patients with more than a ventilator application and 1:2.00 in patients without any ventilator application in general hospitals, respectively. Conclusion: The appropriate staffing level was suggested from 1:1.0 to 1:2.0. The new nursing fee schedules were suggested from 1:1.0 (Grade 1) to 1:3.0 (Grade 5) and recommended to be paid based on the staffing grade, minimum number of nurses, and standard annual working days. It is expected to increase staffing levels and provide a better nursing work environment.

Shear behavior of exposed column base connections

  • Cui, Yao
    • Steel and Composite Structures
    • /
    • v.21 no.2
    • /
    • pp.357-371
    • /
    • 2016
  • Column base connections are critical components in steel structures because they transfer axial forces, shear forces and moments to the foundation. Exposed column bases are quite commonly used in low- to medium-rise buildings. To investigate shear transfer in exposed column base plates, four large scale specimens were subjected to a combination of axial load (compression or tension) and lateral shear deformations. The main parameters examined experimentally include the number of anchor rod, arrangement of anchor rod, type of lateral loading, and axial force ratio. It is observed that the shear resisting mechanism of exposed column base changed as the axial force changed. When the axial force is in compression, the resisting mechanism is rotation type, and the shear force will be resisted by friction force between base plate and mortar layer. The specimens could sustain inelastic deformation with minimal strength deterioration up to column rotation angle of 3%. The moment resistance and energy dissipation will be increased as the number of anchor rods increased. Moreover, moment resistance could be further increased if the anchor rods were arranged in details. When the axial force is in tension, the resisting mechanism is slip type, and the shear force will be resisted by the anchor rods. And the shear resistance was reduced significantly when the axial force was changed from compression to tension. The test results indicated that the current design approach could estimate the moment resistance within reasonable acceptance, but overestimate the shear resistance of exposed column base.

The Effect of Compressive Residual Stress on Computer Corrosion Fatigue Crack of SAE 5155 (SAE 5155강의 컴퓨터부식피로 균열에 미치는 압축잔류응력의 영향)

  • Park, Sung-Mo;Moon, Kwang-Seok;Park, Kyung-Dong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.2
    • /
    • pp.34-40
    • /
    • 2007
  • Antifatigue failure technology take an important part of current industries. Currently, the shot peening is used for removing the defect from the surface of steel and improving the fatigue strength on surface. Therefore, this paper the effect of compressive residual stress and corrosion of spring steel(SAE 5155)by shot-peening on fatigue crack growth characteristics in stress ratio(R=0.05)was investigated with considering fracture mechanics. By using the methods mentioned above, We arrived at the following conclusions. The fatigue crack growth rate(da/dN) of the shot-peening material was lower than that of the un-peening material. And in stage I, ${\Delta}Kth$, the threshold stress intensity factor, of the shot-peen processed material is high in critical parts unlike the un-peening material. Also m, fatigue crack growth exponent and number of cycle of the shot-peening material was higher than that of the un-peening material. That is concluded from effect of da/dN. Finally fracture of shot-peening material and un-peening material was identified and discussed in this study.

  • PDF

Electro-mechanical properties in Bi-2223 superconducting composite tape due to axial fatigue loading (축방향 피로하중에 의한 Bi-2223 복합 초전도선재의 전기-기계적 특성)

  • Shin, Hyung-Seop;Dizon, John Ryan C.;Kim, Ki-Hyun;Oh, Sang-Soo;Ha, Dong-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.345-348
    • /
    • 2004
  • For practical applications, the evaluation of reliability or endurance of HTS conductors is necessary. The mechanical properties and the critical current, $I_c$, of multifilamentary Bi-2223 superconducting tapes, externally reinforced with stainless steel foils, subjected to high cycle fatigue loading in the longitudinal direction were investigated at 77K. The S-N curves were obtained and its transport property was evaluated with the increase of repeated cycles at different stress amplitudes. The effect of the stress ratio, R, on the $I_c$ degradation behavior under fatigue loading was also examined considering the practical application situation of HTS tapes. Microstructure observation was conducted in order to understand the L degradation mechanism in fatigued Bi-2223 tapes.

  • PDF

The Effect of Compressive Residual Stress on Fatigue Fracture of the Spring steel (현가장치용 SUP-9강의 피로파괴에 미치는 압축잔류응력의 영향)

  • Park, Kyoung-Dong;Jin, Young-Beom
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.3
    • /
    • pp.79-85
    • /
    • 2004
  • The lightness of components required in automobile and machinery industry is requiring high strength of components. In particular, fatigue failure phenomena, which happen in metal, bring on danger in human life and property. Therefore, antifatigue failure technology takes an important part of current industries. Currently, the shot peening is used for removing the defects from the surface of steel and improving the fatigue strength on surface. Therefore, in this paper the effect of compressive residual stress of spring steel(JISG SUP-9)by shot peening on fatigue crack growth characteristics in stress ratio(R=0 1, R=0 3, R=0 6)was investigated considering fracture mechanics. By using the methods mentioned above, I arrived at the following conclusions: (1) The fatigue crack growth rate(da/dN) of the shot peening material was lower than the unpeening material And in stage I, ${\Delta}K_{th}$, the threshold stress intensity factor, of the shot peening material is high in critical parts unlike the unpeening material. (2) Fatigue life shows more Improvement in the shot peening material than in the unpeening material. And compressive residual stress of surface on the shot peening processed operate the resistance of fatigue crack propagation.

  • PDF

The Trend of Newspaper Articles for Male Appearance Management (신문기사를 통해 본 남성 외모 관리 경향)

  • Park, Su-Jin;Park, Kil-Soon
    • The Research Journal of the Costume Culture
    • /
    • v.16 no.3
    • /
    • pp.547-558
    • /
    • 2008
  • This study aims on observing the social recognition and its aspects for men taking care of their outer appearances at current point where men are rapidly rising as the main consumer in the beauty industry while their interest for outer appearances are increasing. Therefore, we observed the overall trend and changes in social recognition for male looks by analyzing the contents of newspaper articles from 1990 to 2005 that play the critical role of spreading new information trend while reflecting the interest of people of a certain era. As a result, articles related to male looks were divided into fashion, hair, skin and cosmetics, physical image, cosmetic surgery, trend related to male looks, and male oriented stores and sites, and among them, articles related to fashion and skin took up the highest ratio. Especially articles related to the trend took up the largest ratio as it reflects the properties of two industries launching new products. Moreover, articles related to male looks tended to increase generally according to timely changes, and rapidly increased especially since 2000.

  • PDF

Buckling analysis of steel plates in composite structures with novel shape function

  • Qin, Ying;Luo, Ke-Rong;Yan, Xin
    • Steel and Composite Structures
    • /
    • v.35 no.3
    • /
    • pp.405-413
    • /
    • 2020
  • Current study on the buckling analysis of steel plate in composite structures normally focuses on applying finite element method to derive the buckling stress. However, it is time consuming, computationally complicated and tedious for general use in design by civil engineers. Therefore, in this study an analytical study is conducted to predict the buckling behavior of steel plates in composite structures. Hand calculation method was proposed based on energy principle. Novel buckling shapes with biquadratic functions along both loaded and unloaded direction were proposed to satisfy the boundary condition. Explicit solutions for predicting the critical local buckling stress of steel plate is obtained based on the Rayleigh-Ritz approach. The obtained results are compared with both experimental and numerical data. Good agreement has been achieved. Furthermore, the influences of key factors such as aspect ratio, width to thickness ratio, and elastic restraint stiffness on the local buckling performance are comprehensively discussed.

Frontal Alpha Asymmetry, Heart Rate Variability, and Positive Resources in Bereaved Family Members with Suicidal Ideation after the Sewol Ferry Disaster

  • Jang, Kuk-In;Lee, Sangmin;Lee, Seung-Hwan;Chae, Jeong-Ho
    • Psychiatry investigation
    • /
    • v.15 no.12
    • /
    • pp.1168-1173
    • /
    • 2018
  • Objective After the Sewol ferry disaster, bereavement with suicidal ideation was a critical mental health problem that was accompanied by various neuropsychological symptoms. This study examined the frontal alpha asymmetry (FAA), heart rate variability (HRV), and several psychological symptoms in bereaved family members (BFM) after the Sewol ferry disaster. Methods Eighty-three BFM after the Sewol ferry disaster were recruited. We assessed FAA, HRV, and psychological symptoms, including depression, post-traumatic stress, post-traumatic growth factor, anxiety, grief, and positive resources, between BFM with the presence and absence of current suicidal ideation. Results Compared to BFM without suicidal ideation, BFM with suicidal ideation showed a higher FAA with right dominance. Significant differences in psychological symptoms were observed between the groups. In BFM with suicidal ideation, the low: high frequency (LF:HF) ratio correlated with social resources and support. Conclusion The FAA and LF:HF ratio may be biomarkers that represent the pathological conditions of BFM with suicidal ideation. If researched further, they may shed light on the interaction between bereavement with suicidal ideation and social resources for therapeutic intervention.

Analysis on the Improvement of Power Capacity Increase in the Transformer-Type SFCL with Neutral Lines (중성선을 갖는 변압기형 초전도 한류기의 용량증대 개선 연구)

  • Cho, Yong-Sun;Choi, Hyo-Sang;Kim, Deog-Goo;Go, Sung-Pil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1438-1443
    • /
    • 2011
  • The increase of power capacity in the superconducting fault current limiter (SFCL) is essential for application into the power grid. To achieve this, when superconducting units were connected in series and parallel, the unbalanced quenching characteristics between superconducting units generated by different critical current behavior should be improved. In the transformer-type SFCL, the superconducting units connected in series could be simultaneously quenched by the connection of neutral lines between secondary coils and superconducting units. From this the consumed power in superconducting units was equally distributed. In addition, the more the turn ratio of the transformer was reduced, the more consumed power in the superconducting units was reduced by the decrease of the induction voltage generated in the superconducting units. From those results, the transformer-type SFCL using neutral lines could increase the power capacity of the SFCL by the equal power division into the superconducting units.