• 제목/요약/키워드: crestal bone resorption

검색결과 34건 처리시간 0.022초

Evaluation of Crestal Bone Resorption of the TiUnite(R) Anodized Implant System

  • Kim, Young-Kyun;Ahn, Min-Seok;Lee, Yang-Jin;Yun, Pil-Young
    • Journal of Korean Dental Science
    • /
    • 제1권1호
    • /
    • pp.4-9
    • /
    • 2008
  • Purpose : This study sought to examine the aspects of crestal bone resorption and to evaluate the clinical outcomes of the TiUnite$^{(R)}$ (Nobel Biocare, Sweden) anodized implant system. Materials and Methods : Among the 67 patients (211 fixtures) who were treated using TiUnite(r) implants at Seoul National University Bundang Hospital between March 2004 and January 2007, 26 (91 fixtures) were considered in this study. Initial and secondary stabilities were measured using Periotest$^{(R)}$ and Ostell(tm) Mentor. The radiographic evaluation of crestal bone resorption was carried out by measuring the change in crestal bone level at the time of surgery compared to that 1 year after loading. Panoramic radiograph and periapical radiograph were used. Based on the radiographic findings, the shapes of crestal bone resorption were classified. Results : The average amount of crestal bone resorption after 1 year of functional implant loading was 0.30 mm. There was no saucerization in 40 implant fixtures (43.9%), although more than 1 thread were exposed in 51 implant fixtures (56.6%). The success rate of the implants was 94.5%, and the survival rate was 100%. Conclusions : Good clinical outcomes and minor crestal bone resorption were noted in this study. Saucerization for the establishment of biological width was not a general finding in the TiUnite$^{(R)}$ anodized implant system.

  • PDF

치조정 골흡수에 대한 platform switching이 미치는 영향 (Influence of platform switching on crestal bone resorption)

  • 김도영;김태일;설양조;이용무;구영;류인철;정종평;한수부
    • Journal of Periodontal and Implant Science
    • /
    • 제38권2호
    • /
    • pp.135-142
    • /
    • 2008
  • Purpose: Numerous studies have shown that crestal bone resorption around the implant was related to the location of the implant abutment junction(IAJ). Recently it was hypothesized that platform switching termed the inward horizontal repositioning of the IAJ might limit bone resorption around the implants. The purpose of this clinical study was to evaluate the effect of platform switching on crestal bone resorption. Materials and Methods: The crestal bone loss of 65 external hex implants in 26 patients were radiographically measured at crown placement and follow-up examinations. 23 standard implants(non-platform switching group, NP) were connected with the matching abutments and 42 wide implants(platform switching group, PS) were connected with the 1 mm smaller diameter abutments. Results: There was significant difference of crestal bone loss between NP group and PS group. For implants in the NP group, mean crestal bone loss was $1.18{\pm}0.68\;mm$ at crown placement and $1.42{\pm}0.41\;mm$ at follow-up. The meal bone loss in PS group was $0.47{\pm}0.52\;mm$ at crown placement and $0.60{\pm}0.65\;mm$ at follow-up. When the crestal bone changes according to placement depths of implants were compared, subcrestal position of IAJ had a significantly less bone loss in PS group, but it was not in NP group. Conclusion: Within the limits of the present study, it was concluded that platform switching technique might decrease crestal bone loss around the implants. Additionally, when the IAJ of implant was placed 1 mm deeper in the alveolar bone, the effect of platform switching on bone loss was enhanced.

Beagle dog를 이용한 임프란트 사이의 간격에 따른 골흡수에 대한 방사선 및 조직학적 평가 (INFLUENCE OF INTERIMPLANT DISTANCE ON BONE RESORPTION : A RADIOLOGICAL AND HISTOLOGICAL STUDY IN BEAGLE DOGS)

  • 이수연;이재욱;김진욱;이상한
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권5호
    • /
    • pp.571-577
    • /
    • 2008
  • Introduction: Possible etiologic factors associated with bone loss around implants after implantation are surgical trauma, occlusal overload, periimplantitis, presence of micro gap and the formation of biologic distances. Tarnow et al. observed that the crestal bone loss was greater when the distance between the implants was <3mm than when the implants were ${\geq}\;3mm$ apart. The aim of this study was to evaluate the influence of different interimplant distance on marginal bone and crestal bone resorption in the beagle dogs. Materials and methods: The mandibular premolars of 5 dogs were extracted bilaterally. After 12 weeks of healing, each dog received 7 implants. On each side, implants were separated by 2mm (Group 1) and by 5mm (Group 2). After 16 weeks of healing, the dogs were sacrificed. Marginal bone loss was determined through linear measurements made between the implant-abutment junctions and the most coronal portions of the bone in contact with the implant surface. A line was drawn uniting the implant-abutment junctions of the adjacent implants, and a linear measurement was made at the midpoint in the direction of the most coronal peak of the interimplant bone crest to determine the crestal bone loss. Both of them was measured radiologically and histologically. Result and conclusion: In radiological analysis, the mean of marginal bone loss was $1.26{\pm}0.14mm$ for group 1 and $1.23{\pm}0.34mm$ for group 2, the mean of crestal bone loss was $1.10{\pm}0.14mm$ for group 1 and $1.02{\pm}0.30mm$ for group 2. The results were not statistically significant between 2 groups. In histological analysis, the mean of marginal bone loss was $1.63{\pm}0.48mm$ for group 1 and $1.62{\pm}0.50mm$ for group 2, the mean of crestal bone loss was $1.23{\pm}0.35mm$ for group 1 and $1.15{\pm}0.39mm$ for group 2. The differences were also not statistically significant. The clinical significance of this result is that the increase in the crestal bone loss results in the increase in the distance between the base of the interproximal contact of the crowns and the bone crest, and this determines if papilla will be present or absent between implants. Considering this fact, keeping up sufficient interimplant distance is important to minimize crestal bone loss.

치조능확장골절단술을 이용한 임프란트 식립술의 유용성 평가 (Evaluation of the Availability of Implant placement using Ridge Expansion Osteotomy (REO))

  • 김영균;윤필영;김범수
    • 대한치과의사협회지
    • /
    • 제46권4호
    • /
    • pp.243-247
    • /
    • 2008
  • Purpose : Ridge expansion osteotomy (REO) has been introduced when it is necessary to expand narrow crestal ridge with simultaneous implant placement. This study has designed to evaluate the clinical availability of REO. Materials and methods : Subject were patients who had visited Seoul National University Bundang Hospital from July. 2003 to December, 2005 for implant placement using REO by one surgeon. Intraoperative and postoperative complication, failure of initial osseointegration and marginal bone resorption were estimated using electronic medical record and periapical radiography. Twenty?three patients, 8 males and 15 females, mean age 51, ranged 18 to 72, were treated for mean 26 months, ranged from 16 months to 46 months. Results : Mean diameter and length of implants placed at upper anterior, were 3.72mm and 13.32mm each other. Guided bone regeneration and ridge splitting were accompanied in this study. Five cases of cortical bone fracture, three cases of crestal bone loss more than 2mm, 2cases of gingival recession, and 2 cases of infection were noted, but there were no implants removed because of disintegration. Success rate of implant was 91.7%, even if survival rate of implant was 100%. In addition, there were no statistical significance between the success rate of REO and bone graft(p>0.05). Conclusion : Based on the results of the present study, it can be concluded that REO technique is reliable for implant placement at atrophic ridge with adequate height compared to bone graft and other osteotomies for ridge expansion, but care should be taken of esthetic problem such as gingival recession because of crestal bone resorption from trauma by osteotome.

  • PDF

Analysis of factors affecting crestal bone loss around the implants

  • Park, Ji-Hoon;Kim, Young-Kyun;Yun, Pil-Young;Yi, Yang-Jin;Yeo, In-Sung;Lee, Hyo-Jung;Park, Jin-Young
    • Journal of Korean Dental Science
    • /
    • 제2권2호
    • /
    • pp.12-17
    • /
    • 2009
  • Purpose : To determine whether peri-implant crestal bone loss could be affected by systemic disease, primary ISQ value, implantation method (submerged vs. non-submerged), surface treatment, and bone density Materials and methods : Patients who underwent fixture installation from June 24, 2005 to October 23, 2008 at Seoul National University Bundang Hospital were evaluated. A total of 157 patients (male: 52, female: 85) had 346 fixtures installed. Among them, 49 patients had periapical radiographs taken 1 year after prostheses were first set. A total of 97 fixtures were implanted. In particular, 30 fixtures were installed in patients with systemic diseases such as diabetes mellitus, cardiovascular disease, hypertension, and liver disease. The immediate stability of implants was measured with $Osstell^{tm}$. Implant surface treatment was classified into two groups (RBM, Cellnest (Anodized)), and bone density, into four groups (D1~D4). The bone resorption on the mesial and distal areas of fixtures was measured with periapical radiographs using the paralleling technique, and the mean value was calculated. The length determination program in IMPAX (AGFA, Belgium) was used. Results : At least 332 out of 346 (96%) installed GS II implants were successfully osseointegrated 1 year after prostheses were first set. The mean value of the bone resorption of the installed GS II implants was 0.44mm. The minimum value was 0mm, and the maximum value, 2.85mm. There was a statistically significant difference between the implantation methods (submerged, non-submerged) with regard to the amount of alveolar bone loss 1 year after prostheses were first set (p<0.05). Non-submerged implants showed less crestal bone loss. Note, however, that other variables had no correlation with crestal bone loss (p>0.05). Conclusion : There was a statistically significant difference between the 1-stage method and 2-stage method with regard to the amount of alveolar bone loss 1 year after prostheses were first set. Systemic disease, primary ISQ value, surface treatment, and bone density were not associated with alveolar bone loss. Other variables were assumed to have a correlation with alveolar bone loss.

  • PDF

Comparison of autogenous tooth bone graft and synthetic bone graft materials used for bone resorption around implants after crestal approach sinus lifting: a retrospective study

  • Kim, Young-Kyun;Lee, Junho;Yun, Ji-Young;Yun, Pil-Young;Um, In-Woong
    • Journal of Periodontal and Implant Science
    • /
    • 제44권5호
    • /
    • pp.216-221
    • /
    • 2014
  • Purpose: This retrospective study compares the amount of bone resorption around implants between an autogenous tooth bone graft (AutoBT) and a synthetic bone graft after a bone-added crestally approached sinus lift with simultaneous implant placements. Methods: In all, 37 patients participated in this study. Seventeen patients were grouped as group I and underwent an AutoBT-added sinus lift using the crestal approach. The remaining 20 patients were grouped as group II and underwent synthetic bone grafting. Both groups received the implant placements simultaneously. Of the 37 participating patients, only 22 patients were included in the final results: Eleven patients of group I and 11 patients of group II. Before the surgery, the distance from the alveolar crest to the sinus floor was measured using panoramic radiography. After the surgery, the distance was measured again from the neck of the implant thread to the most superior border of the added graft materials. Then, the amount of sinus lift was calculated by comparing the two panoramic radiographs. After a year, a panoramic radiograph was taken to calculate the resorption of the bone graft material from the radiograph that was taken after the surgery. The significance of the resorption amount between the two types of graft materials was statistically analyzed. Results: The bone height was increased to an average of 4.89 mm in group I and 6.22 mm in group II. The analysis of panoramic radiographs 1 year after the surgery showed an average bone resorption of 0.76 mm and 0.53 mm, respectively. However, the degree of lifting (P=0.460) and the amount of bone-grafted material resorption (P=0.570) showed no statistically significant difference. Conclusions: Based on this limited study, AutoBT can be considered a good alternative bone graft to a synthetic bone graft in a bone-added sinus lift, when extraction is necessary prior to the surgery.

Evaluation of Survival Rate and Crestal Bone Loss of the Osstem GS II Implant System

  • Kim, Young-Kyun;Park, Ji-Hoon;Shen, Winston Tan Kwong;Carreon, Charlotte Ann Z.
    • Journal of Korean Dental Science
    • /
    • 제2권2호
    • /
    • pp.31-34
    • /
    • 2009
  • The survival rate of the OSSTEM GS II Implant 1 year after serving the prosthetic function in 2 domestic and foreign medical institutes was 97.57%; the success rate was 95.7%, and the average alveolar bone resorption was 0.24mm(n=389). In particular, the alveolar bone resorption occurred differently according to the placement location as well as whether or not the patient underwent bone grafting operation, but the implant s length and diameter did not have significant impact on alveolar bone resorption.

  • PDF

Long-term Retrospective Clinical Study Comparing Submerged Type with External Hex Connection and Non-submerged Type with Internal Morse Taper Connection Implants

  • Kwoen, Min-Jeong;Kim, Sang-Yun;Kim, Young-Kyun
    • Journal of Korean Dental Science
    • /
    • 제12권1호
    • /
    • pp.29-37
    • /
    • 2019
  • Purpose: This study was aimed to compare the survival and success rates, and long-term crestal bone loss according to the use of 2 connection types of dental implants (submerged-USII and non-submerged-SSII; Osstem $Implant^{(R)}$) by analyzing the change in alveolar bone height after 1 year under load and during final follow-up period. Materials and Methods: Between December 2004 and August 2008, patients with two types of Osstem implants (USII and SSII) were retrieved retrospectively. A total of 92 patients with 284 implants (USII=60, SSII=224) was finally selected. Their mean follow-up period was 7.5 years. The mesial and distal alveolar crestal bone changes were measured using radiographic images and the average was calculated at 1 year after loading and during final follow-up period. Result: Among the 284 implants, 4 USII and 7 SSII implants were removed, indicating 93.3% and 96.9% survival rates. Of the survived implants, mean crestal bone loss 1 year after loading was 0.39 mm for USII and 0.19 mm for SSII (P=0.018). During the final follow-up, mean crestal bone loss was 0.63 mm and 0.35 mm for USII and SSII, respectively, without statistical significance (P=0.092). According to the criteria for the success and failure of the implant by Albreksson and colleagues, final success rate was estimated as 86.7% for USII and 91.5% for SSII, respectively. Conclusion At 1 year after loading, the average crestal bone loss was significantly different between USII and SSII; however, both types met the criteria for implant success. During the final follow-up, both groups showed insignificant bone resorption patterns and did not show any pathological clinical symptoms. Therefore, both implants exhibited high long-term stability.

손톱 깨물기 습관을 가진 아동의 교정 치료 시 전치부 치근 길이와 치조골 높이의 변화 (Changes of root length and crestal bone height before and after the orthodontic treatment in nail biting patients)

  • 황충주;양재홍
    • 대한치과교정학회지
    • /
    • 제34권1호
    • /
    • pp.47-61
    • /
    • 2004
  • 교정치료의 목표는 치아와 악골의 기능성과 심미성을 높이며 안정성을 도모하는 데에 있지만, 치료 과정 중에 치근 흡수와 치조골 흡수와 같은 여러 가지 후유증이 발생할 수 있다 이러한 치근첨의 흡수는 예측이 불가능하고, 상아질 부위까지 파급될 수 있으며, 발생 후 비가역적이다. 치조골 흡수는 치주 지지의 관점에서 매우 중요한 후유증이다. 이에 여러 가지 구강악습관 중 손톱 깨물기 습관을 가진 아동의 교정 치료 전, 후의 치근과 치조골 높이 변화를 고찰하여, 교정 치료 시 적절한 생역학을 고려하고, 치근흡수와 치조골 상실의 가능성에 대처하고자 본 연구를 시행하였다. 연구대상은 1997년 7월부터 1999년 2월까지 연세대학교 치과대학병원 교정과에 교정치료를 목적으로 내원한 $10\~15$세까지의 청소년 중 큰 골격 변이가 없고, 함께 내원한 부모로부터 손톱 깨물기 습관이 있다고 확인되고 전형적인 손톱 형태 -정기적인 손톱 깎는 일이 없이 치아로 손톱을 뜯는 습관으로 변연이 불규칙한 손톱의 형태 -를 가진 환자 63명을 실험군으로, 같은 연령대의 손톱 깨물기 습관이 없는 환자63명을 대조군으로 설정하였다. 교정 치료 후 실험군은 31명, 대조군은 22명이었다. 교정 치료 전(T1)과 치료 후(T2), 각 군의 전치부 치근단 방사선 사진을 채득하여 치근의 길이와 치조골의 높이를 평가하여 다음과 같은 결과를 얻었다. 1. 교정 치료 전 실험군의 평균 치관/치근 비는 상악 4전치와 하악 우측 측절치에서 대조군보다 유의성 있게 큰 값을 보여주었다. 2. 교정 치료 전 실험군의 치근 길이는 하악 양측 중절치와 상$\cdot$하악 우측 측절치에서 상대적으로 대조군보다 더 짧은 값을 보였다. 3. 교정 치료 전 실험군의 치간골에서 대조군보다 유의성 있는 상실을 보인 곳이 있었다. 4. 교정 치료 후 실험군과 대조군 모두 치근 길이의 감소와 치간골 소실이 있었다. 5. 교정 치료 후 실험군에서 모든 치아의 치관/치근 비의 변화와 치근의 길이 감소가 대조군보다 유의성 있게 크게 나타났다. 6. 교정 치료 후 실험군의 모든 치아의 치간골 높이가 대조군보다 유의성 있게 감소하였다.

What is the effect of initial implant position on the crestal bone level in flap and flapless technique during healing period?

  • Al-Juboori, Mohammed Jasim;Ab Rahman, Shaifulizan;Hassan, Akram;Ismail, Ikmal Hisham Bin;Tawfiq, Omar Farouq
    • Journal of Periodontal and Implant Science
    • /
    • 제43권4호
    • /
    • pp.153-159
    • /
    • 2013
  • Purpose: The level of the implant above the marginal bone and flap design have an effect on the bone resorption during the healing period. The aim of this study is to detect the relationship between the level of the implant at the implant placement and the bone level at the healing period in the mesial and distal side of implants placed with flapless (FL) and full-thickness flap (FT) methods. Methods: Twenty-two nonsubmerged implants were placed with the FL and FT technique. Periapical radiographs were taken of the patient at implant placement, and at 6 and 12 weeks. By using computer software, bone level measurements were taken from the shoulder of the healing cap to the first bone implant contact in the mesial and distal side of the implant surface. Results: At 6 weeks, the correlation between the crestal bone level at the implant placement and crestal bone level of the FT mesially was significant (Pearson correlation coefficient=0.675, P<0.023). At 12 weeks, in the FT mesially, the correlation was nonsignificant (Spearman correlation coefficient=0.297, P<0.346). At 6 weeks in the FT distally, the correlation was nonsignificant (Pearson correlation coefficient=0.512, P<0.107). At 12 weeks in the FT distally, the correlation was significant (Spearman correlation coefficient=0.730, P<0.011). At 6 weeks in the FL mesially, the correlation was nonsignificant (Spearman correlation coefficient=0.083, P<0.809). At 12 weeks in the FL mesially, the correlation was nonsignificant (Spearman correlation coefficient= 0.062, P<0.856). At 6 weeks in the FL distally, the correlation was nonsignificant (Spearman correlation coefficient=0.197, P<0.562). At 12 weeks in the FL distally, the correlation was significant (Pearson correlation coefficient=0.692, P<0.018). Conclusions: A larger sample size is recommended to verify the conclusions in this preliminary study. The bone level during the healing period in the FT was more positively correlated with the implant level at implant placement than in the FL.