• 제목/요약/키워드: crack resistance property

검색결과 66건 처리시간 0.03초

Flexible ITO/PEDOT:PSS Hybrid Transparent Conducting Electrode for Organic Photovoltaics

  • Lim, Kyounga;Jung, Sunghoon;Kang, Jae-Wook;Kim, Jong-Kuk;Kim, Do-Geun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.299-299
    • /
    • 2013
  • Indium Tin Oxide (ITO) has widely been used as a transparent conductive oxide (TCE) for photovoltaic devices. Lately, flexibility of ITO becomes an issue as demand of flexible device increases. Several scientists have tried to substitute ITO to different materials such as conductive polymer, graphene, CNT, and metal nanowire because of ITO brittleness. Among the substitute materials, PEDOT:PSS has mostly paid attention because PEDOT:PSS has excellent flexibility and good conductivity. The conductivity of PEDOT:PSS increases up to 1000 S/cm with additives such as DMSO, EG, sorbitol, and so on. In our research group, we introduce a conductive polymer PEDOT:PSS as a buffer layer to improve not only flexibility but also conductivity. As PEDOT:PSS layer forms beneath ITO thin film (20 nm), sheet resistance decreases from $230{\Omega}$/${\Box}$ to $85{\Omega}$/${\Box}$ and crack initiation decreases from 4.5 mm to 3.5 mm as well. We have fabricated organic photovoltaic device and power conversion efficiencies using conventional ITO electrode and ITO/PEDOT:PSS hybrid electrode. The photovoltaic property such as power conversion efficiency for ITO/PEDOT:PSS hybrid electrode is comparable to the value obtained using conventional ITO electrode on glass substrate.

  • PDF

염해환경에서 외부전원법에 의한 지오폴리머 시험체 보강철근의 방식특성 평가 (Anti-Corrosion Property of Geopolymer Evaluated by an Impressed Current Cathodic Protection Method, Exposed to Marine Environment)

  • 이해승;조규환;박동천
    • 한국건축시공학회지
    • /
    • 제14권5호
    • /
    • pp.397-405
    • /
    • 2014
  • 극한 염해환경에서 철근보강 지오폴리머 시험체의 외부전원법 전기방식 특성을 평가를 위하여 일련의 촉진실험을 실시하였다. 동시에 같은 조건의 보통 시멘트 콘크리트도 제조하여 비교 검토하였다. 환경조건은 침지대, 간만대, 그리고 크랙을 상정하였다. 지오폴리머는 밀실한 재료적 특성에 기인한 열화인자 침투 저항 증대에 의해 자연전위 뿐만 아니라 촉진 종료 후의 부식면적에서도 상당히 우수한 방식 성능이 있는 것으로 밝혀졌으며 향후 제작 양생 등의 문제를 개선함으로써 해양구조물로써의 활용이 다양해질 것으로 기대된다.

기체확산층 물성이 고분자전해질 연료전지 성능에 미치는 영향 (Effect of Gas Diffusion Layer Property on PEMFC Performance)

  • 김준섭;김준범
    • 공업화학
    • /
    • 제31권5호
    • /
    • pp.568-574
    • /
    • 2020
  • 기체확산층은 유로에서 전극으로 반응물을 전달하고, 반응으로 생성되는 물을 배출하는 통로이며 열 배출과 전극 지지대 등의 역할을 하는 고분자전해질 연료전지의 핵심 구성요소이다. 본 연구에서는 국내외 기체확산층 상용 제품인 39BC와 JNT30-A3에 대한 연료전지의 성능 평가를 수행하였다. 25 ㎠ 단위 전지를 이용하여 유량, 상대습도 조건에 대한 분극 곡선을 측정하였고, empirical equation을 이용하여 운전 조건에 대한 성능 인자를 도출하였다. 기체확산층의 PTFE 함량이 높을수록 저항이 증가하였고, 미세다공층의 크랙은 물의 이동 통로로서 농도 손실에 영향을 미쳤다. 또한 상대습도가 낮을수록 Ohmic 저항이 증가하였지만, 전류밀도가 증가할수록 이온전도도가 증가하여 Ohmic 저항이 감소하였다. Empirical equation을 이용한 fitting curve을 통하여 기체확산층의 운전 조건에 대한 성능 인자 경향을 해석할 수 있었다.

프리스트레스트 콘크리트 관형 구조물의 폭발량에 따른 내부폭발저항성능에 관한 실험적 평가 (Experimental Evaluation of Internal Blast Resistance of Prestressed Concrete Tubular Structure according to Explosive Charge Weight)

  • 최지훈;최승재;양달훈;김장호
    • 대한토목학회논문집
    • /
    • 제39권3호
    • /
    • pp.369-380
    • /
    • 2019
  • PSC 구조물에 폭발과 같은 극한하중이 짧은 시간 동안 발생하게 되면 급작스러운 파괴와 그로 인한 수많은 인명 및 재산피해를 발생시킨다. 하지만 원전격납구조물, 가스탱크와 같은 PSC 구조물의 경우 방호 및 방재개념이 포함된 구조설계가 적용되지 않은 실정이며, 특히, 구조물 내부에서 발생하는 폭발압력하중은 피해규모가 외부폭발에 비해 훨씬 크기 때문에 내부폭발하중에 대한 검증은 반드시 필요하다. 따라서, 본 연구에서는 원전격납구조물의 내부폭발에 대한 저항성능을 검토하기 위해 이방향 프리스트레스트 콘크리트 축소모형을 제작하였다. 내부폭발 실험은 22.68, 27.22, 31.75 kg (50, 60, 70 lbs)의 ANFO 폭약을 이용하여 시편으로부터 1,000 mm의 거리에서 폭발시켰으며, 압력하중, 처짐, 변형률, 균열형상, 긴장력 변화 등의 데이터를 분석하였다. 본 연구결과를 이용하여 원전격납구조물의 내부폭발하중 발생 시 손상도 범위 예측이 가능할 것으로 판단된다.

Manufacture of Cement-Bonded Particleboards from Korean Pine and Larch by Curing of Supercritical CO2 Fluid

  • Suh, Jin-Suk;Hermawan, Dede;Kawai, Shuichi
    • Journal of the Korean Wood Science and Technology
    • /
    • 제28권4호
    • /
    • pp.41-50
    • /
    • 2000
  • Cement-bonded particleboard is being used as outdoor siding material all over the world, because this composite particularly bears a light weight, high resistance against fire, decay, and crack by cyclic freezing and thawing, anti-shock property, and strength enhancement. Construction systems are currently changing into a frame-building style and wooden houses are being constructed with prefabrication type. Therefore, they require a more durability at outdoor-exposed sides. In this study, the cement hydration property for Korean pine particle, Japanese larch particle and face- and middle layer particles (designated as PB particle below) used in Korean particleboard-manufacturing company was investigated, and the rapid manufacturing characteristics of cement-bonded particleboard by supercritical $CO_2$ curing was evaluated. Korean pine flour showed a good hydration property, however, larch flour showed a bad one. PB particle had a better hydration property than larch flour. The addition of $Na_2SiO_3$ indicated a negative effect on hydration, however, $MgCl_2$ had a positive one. Curing by supercritical $CO_2$ fluid gave a conspicuous enhancement in the performances of cement-bonded particleboards compared to conventional curing. $MgCl_2$ 3%-added PB particle had the highest properties, and $MgCl_2$ 1%-added Korean pine particle had the second class with the conditions of cement/wood ratio of 2.7, a small fraction-screened particle and supercritical curing. On the contrary, the composition of non-hammermilled or large fraction-screened particle at cement/wood ratio of 2.2 was poorer. Also, the feasibility for actual use of 3%-added, small PB particle-screened fraction was greatest of all the conventional curing treatments. Relative superiority of supercritical curing vs. conventional curing at dimensional stability was not so apparent as in strength properties. Through the thermogravimetric analysis, it was ascertained that the peak of a component $CaCO_3$ was highest, and the two weak peaks of calcium silicate hydrate and ettringite and $Ca(OH)_2$ were present in supercritical treatment. Accordingly, it was inferred that the increased formation of carbonates in board contributes to strength enhancement.

  • PDF

잠열성 결합재를 활용한 콘크리트의 특성에 관한 실험적 연구 (An Experimental Study on Properties of Concrete Using Latent Heat Binder)

  • 김용로;김도수;길배수;김욱종;이도범
    • 콘크리트학회논문집
    • /
    • 제20권5호
    • /
    • pp.661-668
    • /
    • 2008
  • 콘크리트구조물의 초고층화, 대형화 및 장대화에 따라 초고층 건축물의 매트 기초, 장대형 교량의 교각 기초, LNG 저장시설 등과 같은 수화열 관리가 반드시 필요한 대형 매스콘크리트의 적용 사례가 증가함에 따라 콘크리트의 온도균열을 효과적으로 제어할 수 있는 보다 성능 향상되고 실용적인 기술의 개발이 건설현장에서 요구되고 있다. 이에 본 연구에서는 대형 매스콘크리트의 수화열 저감을 위한 새로운 기술로서 일정 온도에서 상변화를 일으키는 잠열재를 활용하여 콘크리트 수화열 제어를 위한 잠열성 결합재를 개발하고, 이를 사용한 콘크리트의 기초물성, 내구성 및 수화발열 특성 등을 평가하였다. 연구결과 잠열성 결합재는 콘크리트의 기초물성 및 내구성에 영향을 미치지 않고, 콘크리트의 수화열 저감 및 온도균열 제어에 우수한 성능을 나타내는 것을 확인할 수 있었으며, 대형 매스콘크리트 구조물의 수화열 저감을 위한 유효한 기술로서 실용화될 수 있을 것으로 판단된다.

단면보수용 콘크리트 패치재료의 역학적 특성 및 내구성 실험 (Mechanical and Durability Properties of Partial-Depth Patch Materials using Polymer Materials for Concrete Pavement)

  • 양성철;황인동;한승환;김성민
    • 한국도로학회논문집
    • /
    • 제11권3호
    • /
    • pp.23-32
    • /
    • 2009
  • 본 연구에서는 콘크리트포장의 단면보수용 복합재료 8개(초속경시멘트계열 : RCC 3종, 폴리머시멘트계열 : PCC 2종, 폴리머계열 : PC 3종)에 대해 역학적인 특성 및 내구성 실험을 수행하였다. 역학적 특성으로서 응결시간, 압축강도, 휨강도, 탄성계수, 경화수축에 대해 실험하였고, 내구성으로서 동탄성계수 및 동결융해 후 부착강도, 흡수율, 내화학성, 자외선 노출 실험을 수행하였다. 탄성계수는 RCC>PCC>PC계열의 순으로 나타나서 폴리머가 사용되면서 연성의 특성을 보였다. 초기 재령에서의 폴리머 콘크리트의 경화수축이 상대적으로 큰 것으로 관찰되었지만 재령 28일에서는 다소 안정된 결과를 보였다. 상대동탄성계수, 흡수율, 10% $CaCl_2$와 10% $Na_2SO_4$의 화학용액을 사용한 내화학성 실험결과 PC계열, PCC계열, RCC계열 순으로 저항성이 우수한 것으로 나타났다. 200~300회 동결융해 이후의 부착강도 실험결과 PC-2를 제외하고는 모두 1.3MPa 이상을 확보하였고, PC 및 PCC 제품의 부착강도가 RCC 제품보다 전체적인 면에서 우수한 것으로 나타났다. 또한 시편을 500시간동안 자외선 노출시험 결과 모든 패치재료 시편에서 균열 및 표면 결함 등이 발견되지 않아 PC 및 PCC 제품의 자외선에 대한 내구성이 확보됨을 확인하였다.

  • PDF

탄화규소로 코팅된 탄소-탄소 복합재료의 단열 특성 (Characterizations on the Thermal Insulation of SiC Coated Carbon-Carbon Composites)

  • 서형일;임병주;신인철;배수빈;이형익;최균;이기성
    • Composites Research
    • /
    • 제33권3호
    • /
    • pp.101-107
    • /
    • 2020
  • 본 논문에서는 탄화규소로 코팅된 탄소-탄소복합재료의 단열 특성을 고찰하였다. 탄소-탄소 복합재료 상에 탄화규소를 화학증착법(CVD)법으로 코팅하였다. 먼저 탄화규소로 코팅한 복합재와 코팅되지 않은 복합재에 대해, 공기 중에서 1350℃의 온도를 급작스럽게 부가하였을 때의 단열특성을 서로 비교하는 연구를 수행하였다. 또한 본 연구에서는 최대 1700℃ 및 2000℃의 온도에 복합재의 표면을 노출시키는 고온 버너실험을 수행하였다. 버너실험 전, 후의 무게를 측정하여 무게변화를 고찰하였다. 고온 버너실험 후 탄소-탄소 복합재 및 탄화규소로 코팅된 복합재의 손상여부를 비교, 고찰하였다. 그 결과 2000℃의 온도에 노출 시 탄화규소 코팅재에서 박리, 균열, 공동 등의 결함손상들이 발견되었으나, 고온으로부터 탄소-탄소 복합재를 보호하는데 효과적이었다.

에어로졸 증착법에 의한 YSZ 코팅된 AA1050 알루미늄 합금의 전기화학적 부식 특성 (Electrochemical Corrosion Properties of YSZ Coated AA1050 Aluminium Alloys Prepared by Aerosol Deposition)

  • 유현삼;임태섭;류정호;박동수;홍성현
    • 한국세라믹학회지
    • /
    • 제48권5호
    • /
    • pp.439-446
    • /
    • 2011
  • Yttria stabilized zirconia (YSZ) coating was formed on AA1050 Al alloys by aerosol deposition (AD), and its electrochemical corrosion properties were investigated in 3.5 wt% NaCl and 0.5M $H_2SO_4$ solutions. The crack-free, dense, and ~5 ${\mu}m$ thick YSZ coating was successfully obtained by AD. The as-deposited coating was composed of cubic-YSZ nanocrystallites of ~10 nm size. The potentiodynamic test indicated that the YSZ coated Al alloy had much lower corrosion current densities (2 nA/$cm^2$) by comparison to uncoated sample and exhibited a passive behavior in anodic branch. Particularly, a pitting breakdown potential could not be identified in $H_2SO_4$. EIS tests revealed that the impedance of YSZ coated sample was ${\sim}10^6{\Omega}cm^2$ in NaCl and ${\sim}10^7{\Omega}cm^2$ in $H_2SO_4$, which was about 3 or 4 orders of magnitude higher than that of uncoated sample. Consequently, the corrosion resistance of Al alloy had been significantly enhanced by the YSZ coating.

일방향 및 평직 CF/Mg 복합재 적층판의 부식에 따른 미세조직 및 기계적 특성 변화 (Microstructure and Mechanical Property Changes of Unidirectional and Plain Woven CF/Mg Composite Laminates after Corrosion)

  • 임시온;이정무;이상관;박용호;박익민
    • 대한금속재료학회지
    • /
    • 제50권9호
    • /
    • pp.697-702
    • /
    • 2012
  • In this study, unidirectional and plain woven carbon fiber reinforced magnesium matrix composite laminates were fabricated by the liquid pressing infiltration process, and evolutions of the microstructure and compressive strength of the composite laminates under corrosion were investigated by static immersion tests. In the case of the unidirectional composite laminate, the main microstructural damage during immersion appeared as a form of corrosion induced cracks, which were formed at both CF/Mg interfaces and the interfaces between layers. On the otherhand, wrap/fill interface cracks were mainly formed in the plain woven composite laminate, without any cracks at the CF/Mg interface. The formation of these cracks was considered to be associated with internal thermal residual stress, which was generated during cooling after the fabrication process of these materials. As a consequence of the corrosion induced cracks, the thickness of both laminates increased in directions vertical to the fibers with increasing immersion time. With increasing immersion time, the compressive strengths of both composite laminates also decreased continuously. It was found that the plain woven composite laminates have superior corrosion resistance and stability under a corrosive condition than unidirectional laminates.