• Title/Summary/Keyword: coupling ratio

Search Result 657, Processing Time 0.023 seconds

Novel Design Conditions to Optimize Power Coupling in Optical Grating-Assisted Directional Couplers

  • Ho, Kwang-Chun;Kong, Hyung-Yun
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.508-511
    • /
    • 2002
  • By defining a power distribution ratio (PDR) and coupling efficiency (CE) amenable to the rigorous analytical solutions of newly developed rigorous modal transmission-line theory (MTLT), we explicitly analyze the power coupling characteristics of TE modes propagating in GADCs. The numerical results reveal that the incident power is optimally coupled into the desired guiding channel if the powers of rigorous modes excited at the input boundary of grating-assisted coupler are equally partitioned.

  • PDF

Effect of the Exercise Load on the Locomotor-Respiratory Coupling (운동부하가 움직임-호흡 결합에 미치는 영향)

  • Namkung, Young;Park, Eun-Young;Park, Ho-Joon
    • Physical Therapy Korea
    • /
    • v.5 no.3
    • /
    • pp.56-62
    • /
    • 1998
  • The nature of entrainment between the locomotor and the respiratory rhythm was investigated while normal human subjects were walked or running on a treadmill. The purpose of this study was to analyze the incidence and type of coordination between the locomotor and the respiratory rhythm during running at different work load. The experiments were carried out on 12 untrained volunteers exercising at 3 work loads (2 METs, 3 METs, 4 METs in randomized order). The gait cycle was measured by electromyography (EMG) signal of gastrocnemius firing and the respiratory cycle was measured by a thermometer. We found that the ratio between the locomotor and the respiratory rhythm existed and 2:1 ratio between the locomotor-respiratory coupling was dominant at 2 METs and 3 METs.

  • PDF

Analysis on Current Limiting and Recovery Characteristics of a SFCL using Magnetic Coupling of Two Coils with Series Connection (직렬연결된 두 코일의 자기결합을 이용한 초전도 전류제한기의 전류제한 및 회복특성 분석)

  • Lim, Sung-Hun;Kim, Jin-Seok;Ahn, Jae-Min;Moon, Jong-Fil;Kim, Jae-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.281-283
    • /
    • 2008
  • The superconducting fault current limiter (SFCL) using magnetic coupling of two coils with series connection, which was suggested by us, has the merit to increase the operational current and the limiting impedance of the SFCL through the adjustment of the inductance ratio and the winding direction of two coils. In addition, the recovery characteristics of the SFCL is affected by the winding direction of two coils as well as two coils' inductance ratio. In this paper, the fault current limiting and recovery characteristics of a SFCL using magnetic coupling of two coils with series connection were analyzed. Through the analysis based on the experimental results, the recovery characteristics and the current limiting characteristics of the SFCL were confirmed to be improved more in case of the additive polarity winding.

  • PDF

Extraction Solution for the Coupling Coefficient at the Magnetically Coupled Wireless Power Transmission (자계 결합 무선 전력 전송에서의 결합 계수 추출 방법)

  • Kim, Gun-Young;Lee, Bom-Son
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.9
    • /
    • pp.1073-1078
    • /
    • 2012
  • This paper presented the extraction solution for the coupling coefficient at the magnetically coupled wireless power transmission(WPT) system through the analysis of its equivalent circuit considering the loss. The conventional extraction solution using coupled mode theory is generalized employing the extracted solution considering the load resistance. Consequently, the measuring process of extracting coupling coefficient becomes convenient since the even/odd mode analysis is not necessary. Furthermore, the coupling coefficient obtained from the induced extraction method was in excellent agreement with the coupling coefficient obtained using the ratio of magnetic flux passing through the two loops. The extraction of the accurate coupling coefficient at the magnetically coupled WPT is an essential work to analyze and optimize the WPT system.

Plastic hinge length for coupled and hybrid-coupled shear walls

  • Abouzar Jafari;Meysam Beheshti;Amir Ali Shahmansouri;Habib Akbarzadeh Bengar
    • Steel and Composite Structures
    • /
    • v.48 no.4
    • /
    • pp.367-383
    • /
    • 2023
  • A coupled wall consists of two or more reinforced concrete (RC) shear walls (SWs) connected by RC coupling beams (CBs) or steel CBs (hybrid-coupled walls). To fill the gap in the literature on the plastic hinge length of coupled walls, including coupled and hybrid-coupled shear walls, a parametric study using experimentally validated numerical models was conducted considering the axial stress ratio (ASR) and coupling ratio (CR) as the study variables. A total of sixty numerical models, including both coupled and hybrid-coupled SWs, have been developed by varying the ASR and CR within the ranges of 0.027-0.25 and 0.2-0.5, respectively. A detailed analysis was conducted in order to estimate the ultimate drift, ultimate capacity, curvature profile, yielding height, and plastic hinge length of the models. Compared to hybrid-coupled SWs, coupled SWs possess a relatively higher capacity and curvature. Moreover, increasing the ASR changes the walls' behavior to a column-like member which decreases the walls' ultimate drift, ductility, curvature, and plastic hinge length. Increasing the CR of the coupled SWs increases the walls' capacity and the risk of abrupt shear failure but decreases the walls' ductility, ultimate drift and plastic hinge length. However, CR has a negligible effect on hybrid-coupled walls' ultimate drift and moment, curvature profile, yielding height and plastic hinge length. Lastly, using the obtained results two equations were derived as a function of CR and ASR for calculating the plastic hinge length of coupled and hybrid-coupled SWs.

Improvement of extinction ratio of polarization independent very short vertical directional couplers with the double-sided deep-ridge waveguide structure (편광에 관계없이 매우 짧은 결합길이를 가지는 Double-Sided Deep-Ridge 도파관 구조 수직 방향성 결합기의 소멸비 향상)

  • 정병민;김부균
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.12-16
    • /
    • 2004
  • We show that the extinction ratio is improved using slight asymmetry in two core refractive indices of polarization independent very short vertical directional couplers with the double-sided deep-ridge (DSDR) waveguide structure. The optimum asymmetry with the maximum extinction ratio and the tolerance of the refractive index of core with the extinction ratio larger 1ha]1 30 ㏈ increase as the thickness of inner cladding layer and the two cores decrease due to the increase of the coupling strength between the two cores. Also, the device length and the tolerance of the device length with the extinction ratio larger than 30 ㏈ decrease as the thickness of the inner cladding layer and the two cores decrease due to the increase of the coupling strength between the two cores. We show that polarization independent vertical directional couplers with the DSDR waveguide structure with the device length less than 100 ${\mu}{\textrm}{m}$ and the extinction ratio larger than 30 ㏈ could be implemented.

Bleeding characteristics of coupling materials for installation of acoustic emission (AE) sensor (AE 센서 설치를 위한 커플링 재료의 블리딩 특성)

  • Lee, Jong-Won;Kim, Hyunwoo;Kim, Min-Koan;Oh, Tae-Min
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.4
    • /
    • pp.635-650
    • /
    • 2017
  • Acoustic emission (AE) sensors have broadly used to monitor the damage of underground structures and tunnels. The reliability of measured signal is determined by the coupling condition of the AE sensors which are embedded in the target underground structure. To secure the reliability of health monitoring results, it is important to understand the characteristics of the coupling materials. In this study, laboratory tests were performed using portland cement, micro cement, and gypsum as coupling materials in order to verify the bleeding characteristics. The effective parameters for bleeding were determined to be water-cement ratio, material type, curing time, and injected volume of coupling materials. As a results of the experimental study, the bleeding rate increases with an increase in a water-cement ratio and an injected volume; for portland cement, water-cement ratio and injected volume effects are larger than the micro cement. However, curing time is not much effective for occurrence of the bleeding phenomenon. It is anticipated that this study may be useful for the selection of suitable coupling materials for installation of acoustic emission sensors.

Effects of Matrix Ductility on the Shear Performance of Precast Reinforced HPFRCC Coupling Beams

  • Yun Hyun-Do;Kim Sun-Woo;Jeon Esther;Park Wan Shin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.53-56
    • /
    • 2005
  • This paper investigates the effect of ductile deformation behavior of high performance hybrid fiber-reinforced cement composites (HPHFRCCs) on the shear behavior of coupling beams to lateral load reversals. The matrix ductility and the reinforcement layout were the main variables of the tests. Three short coupling beams with two different reinforcement arrangements and matrixes were tested. They were subjected to cyclic loading by a suitable experimental setup. All specimens were characterized by a shear span-depth ratio of 1.0. The reinforcement layouts consisted of a classical scheme and diagonal scheme without confining ties. The effects of matrix ductility on deflections, strains, crack widths, crack patterns, failure modes, and ultimate shear load of coupling beams have been examined. The combination of a ductile cementitious matrix and steel reinforcement is found to result in improved energy dissipation capacity, simplification of reinforcement details, and damage-tolerant inelastic deformation behavior. Test results showed that the HPFRCC coupling beams behaved better than normal reinforced concrete control beams. These results were produced by HPHFRCC's tensile deformation capacity, damage tolerance and tensile strength.

  • PDF

Analytic Derivation of Single Transmission Line Parameters for Weakly Coupled Meander Line (약 결합된 Meander Line의 단일전송선 Parameter의 해석적 계산)

  • 염경환;강명숙
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.5
    • /
    • pp.738-747
    • /
    • 2000
  • In this paper it is shown that the meander line at the low frequency can be thought as the single transmission line whose characteristic impedance is approximately equal to that without coupling. But the length is contracted from that without coupling. The approximate contraction ratio is derived for weak coupling and is compared with the circuit simulation results and the EM simulation results. The formula are in good agreement with the simulation results in weak coupling.

  • PDF

Bearing Strength of Steel Coupling Beams-Wall Connections depending upon Joint Details (접합부 상세에 따른 철골 커플링 보-벽체 접합부의 지압강도)

  • Park Wan-Shin;Yun Hyun-Do;Han Byung-Chan;Hwang Sun-Kyung;Yang Il-Seong;Kim Sun-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.113-116
    • /
    • 2004
  • No specific guidelines are for computing the shear strength of steel coupling beam connections embedded in the reinforced concrete shear wall. In this paper, a theoretical study of the strength of hybrid coupled shear wall connections is achieved. The bearing stress at failure in the concrete below the steel coupling beam section is related to the concrete compressive strength and the ratio of the width of the steel coupling beam section to the thickness of the hybrid coupled shear wall. To revise factor affecting shear transfer strength across connections between coupled shear walls and steel coupling beam, experimental studies are achieved. The main test variables were auxiliary details of stud bolts. In this studies, these proposed equations are shown to be in good agreement with the test results reported in the paper and with other test data in the literature.

  • PDF