• 제목/요약/키워드: counting time

검색결과 483건 처리시간 0.033초

COUNTING STATISTICS MODIFIED BY TWO DEAD TIMES IN SERIES

  • Choi, H.D.
    • Nuclear Engineering and Technology
    • /
    • 제43권3호
    • /
    • pp.287-300
    • /
    • 2011
  • Counting statistics modified by introducing two dead times in series under a Poisson input distribution are discussed. A previous study examined the two cases of series combinations of nonextended-extended (NE-E) and extended-extended (EE) dead times. The present study investigated the remaining two cases of extended-nonextended (E-NE) and nonextended-nonextended (NE-NE) dead times. For the three time origins of the counting processes - ordinary, equilibrium, and shifted processes - a set of formulae was newly developed from a general formulation and presented for the event time interval densities, total densities, and exact mean and variance of the counts in a given counting duration. The asymptotic expressions for the mean and variance of the counts, which are most convenient for applications, were fully listed. The equilibrium mean count rates distorted by the three dead times in series were newly derived from the information obtained in these studies. An application of the derived formulae is briefly discussed.

몬테칼로 전산모사를 이용한 복합 G-M 계수기 불감시간 모형의 계측 통계 연구 (A Study on Counting Statistics of the Hybrid G-M Counter Dead Time Model Using Monte Carlo Simulations)

  • 이상훈;제무성
    • Journal of Radiation Protection and Research
    • /
    • 제29권4호
    • /
    • pp.269-273
    • /
    • 2004
  • 고계수율 환경에서의 G-M 계수기의 가용 범위를 확장하기 위하여 두 가지 불감시간(연장가능 및 연장불능)을 채택한 복합 모형이 개발되었으며, 이 복합모형 참 계수율과 실측 계수율간의 상관관계를 보다 정확히 설명한다. 이 논문에서는 몬테칼로 모사법에 근거한 G-M 계수기 불감효과 분석 프로그램 GMSIM을 개발하여 연장가능 불감시간 모형 및 연장불능 불감시간 모형에 적용하여 그 정확도를 확인하였다. GMSIM을 이용하여 복합 불감시간 모형을 따르는 G-M 계수기의 계수 통계 특성을 분석한 결과, 두 가지 이상적 모형의 중간적 특성을 보였다. 향후 GMSIM은 세 가지 모형의 불감시간 특성을 분석하는데 사용될 수 있다.

광학센서를 이용한 알약계수기의 계수알고리즘 향상에 관한 연구 (Research for enhanced counting algorithm of optical pill counting machine)

  • 홍인기;원민규;이순걸
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.683-686
    • /
    • 2002
  • It is fundamental to count and pack the pills in the medicine manufacture field but those tasks are time and labor consuming. Thus, the need fur automation of those tasks is necessarily getting increased in order to get effective mass production. It Is significant to perceive pills quickly and precisely. There were many trials for this processing but the performance of the existing counting machines varies about size, shape and dispersion tendency of pills. In this paper, the authors try to improve the counting performance of a pill counting machine that has optical sensors with the neural network. The passing signal of pill is acquired with optical sensor and the passage signal of the pill is extracted as input patterns. The gradient and integration of signal during passing time and the time keeping the pill interrupt the light from the LED are used as characteristic feature. The back propagation and perception algorithm are used for training. Experimental results with several pills show that the designed algorithm is a little bit effective to reduce the noise effect which is generated from interference among the machine components and unreliable environment.

  • PDF

방사능 존재확인과 정량분석시 최적화된 측정시간의 결정을 위한 계측전략 (Counting Strategies in Radioactivity Measurement for the Monitoring and Screening)

  • 서경원
    • Journal of Radiation Protection and Research
    • /
    • 제23권2호
    • /
    • pp.65-74
    • /
    • 1998
  • 저 준위방사능 계측에서 가장 기본적으로 요구되는 것이 최적 측정시간의 결정이다. 최적화된 계측전략으로 측정시간을 결정하기 위하여 측정시간을 고정하는 방법, 측정값을 고정하는 방법, 시료와 자연계수율 또는 기준준위를 비교하여 측정하는 방법을 비교 검토하는 결정식을 도출하였다. 이 계측전략에서 기기에 주어진 측정조건 즉, 검출기의 효율, 측정기의 용량, 측정기의 최대 및 평균 자연계수율과 관련기준 즉, 기준준위, 검출한계 등을 만족하는 측정시간이 결정된다. 계측전략은 측정시 주어진 조건에서 방사능 존재확인과 정량분석에 대한 시료의 최적 측정시간의 결정을 편리하게 함으로써 일상의 저준위방사능 측정에 유용하게 사용될 것이다.

  • PDF

방사선 스펙트럼 계측기 (Multi-Channel Analyzer)의 Live-Time 보상회로에 관한 연구 (A Study on Electronic Circuit for Liwe-Time Correction in Multi-Channel Analyzer : Survey and Analysis)

  • 황인구;권기춘;송순자
    • Nuclear Engineering and Technology
    • /
    • 제27권5호
    • /
    • pp.784-791
    • /
    • 1995
  • 방사선계측에서는 방사선검출기(detector)로부터 나오는 pulse를 처리하는 데 있어서 pulse의 counting 손실이 발생한다. 이 손실을 최소화하거나 보상하기 위한 여러가지 방법들이 제시되어 왔으나, 아직도 절대적인 해답이 확립되지 않은 실정이다. 본 연구에서는 기 제시된 보상알고리즘들을 그 기능을 구현하는 전자회로와 함께 기술하고 특징을 분석하였다. 또한 본 연구를 통해 pulse의 counting손실을 보상하는 한가지 알고리즘 개선방향을 제시하였다.

  • PDF

A novel method for cell counting of Microcystis colonies in water resources using a digital imaging flow cytometer and microscope

  • Park, Jungsu;Kim, Yongje;Kim, Minjae;Lee, Woo Hyoung
    • Environmental Engineering Research
    • /
    • 제24권3호
    • /
    • pp.397-403
    • /
    • 2019
  • Microcystis sp. is one of the most common harmful cyanobacteria that release toxic substances. Counting algal cells is often used for effective control of harmful algal blooms. However, Microcystis sp. is commonly observed as a colony, so counting individual cells is challenging, as it requires significant time and labor. It is urgent to develop an accurate, simple, and rapid method for counting algal cells for regulatory purposes, estimating the status of blooms, and practicing proper management of water resources. The flow cytometer and microscope (FlowCAM), which is a dynamic imaging particle analyzer, can provide a promising alternative for rapid and simple cell counting. However, there is no accurate method for counting individual cells within a Microcystis colony. Furthermore, cell counting based on two-dimensional images may yield inaccurate results and underestimate the number of algal cells in a colony. In this study, a three-dimensional cell counting approach using a novel model algorithm was developed for counting individual cells in a Microcystis colony using a FlowCAM. The developed model algorithm showed satisfactory performance for Microcystis sp. cell counting in water samples collected from two rivers, and can be used for algal management in fresh water systems.

Determination of counting efficiency considering the biodistribution of 131I activity in the whole-body counting measurement

  • MinSeok Park ;Jaeryong Yoo;Minho Kim ;Won Il Jang ;Sunhoo Park
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.295-303
    • /
    • 2023
  • Whole-body counters are widely used to assess internal contamination after a nuclear accident. However, it is difficult to determine radioiodine activity due to limitations in conventional calibration phantoms. Inhaled or ingested radioiodine is heterogeneously distributed in the human body, necessitating time-dependent biodistribution for the assessment of the internal contamination caused by the radioiodine intake. This study aims at calculating counting efficiencies considering the biodistribution of 131I in whole-body counting measurement. Monte Carlo simulations with computational human phantoms were performed to calculate the whole-body counting efficiency for a realistic radioiodine distribution after its intake. The biodistributions of 131I for different age groups were computed based on biokinetic models and applied to age- and gender-specific computational phantoms to estimate counting efficiency. After calculating the whole-body counting efficiencies, the efficiency correction factors were derived as the ratio of the counting efficiencies obtained by considering a heterogeneous biodistribution of 131I over time to those obtained using the BOMAB phantom assuming a homogeneous distribution. Based on the correction factors, the internal contamination caused by 131I can be assessed using whole-body counters. These correction factors can minimize the influence of the biodistribution of 131I in whole-body counting measurement and improve the accuracy of internal dose assessment.

색소 농도에 따른 형광 광자의 계수율 : 광자 검출기의 dead time 효과 (Fluorescence photon counting rate as a function of dye concentration: Effect of dead time of photon detector)

  • 고동섭
    • 한국광학회지
    • /
    • 제8권4호
    • /
    • pp.353-355
    • /
    • 1997
  • 공초점 형광 현미경과 단일 광자 계수기로 구성되어 있는 단일 분자 검출장치를 사용하여, 색소 농도에 따른 광자 계수율의 변화를 관측하였다. 농도가 증가함에 따라 계수율이 포화하는 경향을 보였으며, 광검출기의 죽은 시간을 고려하여 측정 결과를 설명하였다. 계수율과 검출 부피, 광검출기의 양자효율, 입사 광량 사이의 관계를 나타내는 관계식을 제시하였다. 또한 신호대 잡음비에 대해서도 간략하게 논하였다.

  • PDF

Development of People Counting Algorithm using Stereo Camera on NVIDIA Jetson TX2

  • Lee, Gyucheol;Yoo, Jisang;Kwon, Soonchul
    • International journal of advanced smart convergence
    • /
    • 제7권3호
    • /
    • pp.8-14
    • /
    • 2018
  • In the field of surveillance cameras, it is possible to increase the people detection accuracy by using depth information indicating the distance between the camera and the object. In general, depth information is obtained by calculating the parallax information of the stereo camera. However, this method is difficult to operate in real time in the embedded environment due to the large amount of computation. Jetson TX2, released by NVIDIA in March 2017, is a high-performance embedded board with a GPU that enables parallel processing using the GPU. In this paper, a stereo camera is installed in Jetson TX2 to acquire depth information in real time, and we proposed a people counting method using acquired depth information. Experimental results show that the proposed method had a counting accuracy of 98.6% and operating in real time.

Propidium monoazide와 real-time PCR을 이용한 살아있는 Enterococcus faecalis의 선택적인 검출 (SELECTIVE DETECTION OF VIABLE ENTEROCOCCUS FAECALIS USING PROPIDIUM MONOAZIDE IN COMBINATION WITH REAL-TIME PCR)

  • 김신영;이승종;김의성;서덕규;송윤정;정일영
    • Restorative Dentistry and Endodontics
    • /
    • 제33권6호
    • /
    • pp.537-544
    • /
    • 2008
  • 세균의 검출에 있어서 polymerase chain reaction (PCR) 방법은 기존의 plate counting과 달리 빠르게 세균을 검출할 수 있다. 하지만 세균이 죽은 후에도 DNA는 장기간 존재할 수 있기 때문에, DNA에 기초한 분석은 살아있는 세균과 죽은 세균을 구분할 수 없다. 최근에 DNA extraction전에 propidium monoazide (PMA)를 처리하여 살아있는 세균만 선택적으로 검출하는 방법이 제시되었다. PMA는 손상된 세포막만 통과하여 죽은 세포의 DNA와 빛 노출 하에서 결합하여 PCR이 증폭되는 것을 막는다. Enterococcus faecalis는 근관치료의 실패에 있어서 중요한 원인이 되는 세균으로 제시되어 왔다. 그리고 chlorhexidine (CHX)은 E. faecalis의 제거에 있어서 효과적인 약제임이 밝혀졌다. 이번 실험의 목적은 세균 수의 측정에 있어서, PMA 처리와 real-time PCR 방법의 적용 가능성을 기존의 plate counting과 비교하여 알아보는 것이다. 또한 E. faecalis에 대한 2% CHX의 살균 효과를 PMA 처리 후 real-time PCR 방법을 사용하여 알아보는 것이다. 실험 방법으로 먼저 살아있는 세균과 죽은 세균을 다른 비율로 섞어서 PMA를 처리한 후 real-time PCR을 시행하여 PMA가 빛 노출 하에서 죽은 세균의 DNA와 결합하는 효과를 나타내는지 알아보았다. 다음으로 PMA 처리 후 realtime PCR 방법을 이용하여 살아있는 세균의 양을 측정한 것을 plate counting으로 얻은 CFU와 비교하였다. 마지막으로 2% CHX의 처리시간을 다르게 하였을 때 E. faecalis에 대한 살균 효과를 PMA 처리 후 real-time PCR 방법을 사용하여 알아보았다. 실험 결과로 살아있는 E. faecalis의 비율이 감소할수록 Ct value는 증가하였다. 그리고 PMA 처리 후 real-time PCR 방법을 이용하여 세균의 양을 측정한 것과 plate counting으로 얻은 CFU 사이에는 Optical density (OD) 값이 1.0일 때까지는 상관관계가 있었다. 하지만 OD 값이 1.5일 때는, PMA를 처리한 후 real-time PCR을 시행했을 때 측정된 살아있는 세균의 양이 감소하였음에 반해서 plate counting에 의한 CFU는 계속 증가하였다. 마지막으로 2% CHX을 오래 적용할수록 살아있는 E. faecalis의 상대적인 양이 감소하는 것을 PMA 처리와 real-time PCR 방법을 이용해 확인하였다.