• Title/Summary/Keyword: counting time

Search Result 482, Processing Time 0.027 seconds

COUNTING STATISTICS MODIFIED BY TWO DEAD TIMES IN SERIES

  • Choi, H.D.
    • Nuclear Engineering and Technology
    • /
    • v.43 no.3
    • /
    • pp.287-300
    • /
    • 2011
  • Counting statistics modified by introducing two dead times in series under a Poisson input distribution are discussed. A previous study examined the two cases of series combinations of nonextended-extended (NE-E) and extended-extended (EE) dead times. The present study investigated the remaining two cases of extended-nonextended (E-NE) and nonextended-nonextended (NE-NE) dead times. For the three time origins of the counting processes - ordinary, equilibrium, and shifted processes - a set of formulae was newly developed from a general formulation and presented for the event time interval densities, total densities, and exact mean and variance of the counts in a given counting duration. The asymptotic expressions for the mean and variance of the counts, which are most convenient for applications, were fully listed. The equilibrium mean count rates distorted by the three dead times in series were newly derived from the information obtained in these studies. An application of the derived formulae is briefly discussed.

A Study on Counting Statistics of the Hybrid G-M Counter Dead Time Model Using Monte Carlo Simulations (몬테칼로 전산모사를 이용한 복합 G-M 계수기 불감시간 모형의 계측 통계 연구)

  • Lee, Sang-Hoon;Jae, Moo-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.269-273
    • /
    • 2004
  • The hybrid dead time model adopting paralyzable (or extendable) and non-paralyzable (or non-extendable) dead times has been introduced to extend the usable range of G-M counters in high counting rate environment and the relationship between true and observed counting rates is more accurately expressed in the hybrid model. GMSIM, dead time effects simulator, has been developed to analyze the counting statistics of G-M counters using Monte Carlo simulations. GMSIM accurately described the counting statistics of the paralyzable and non-paralyzable models. For G-M counters that follow the hybrid model, the counting statistics behaved in between two idealized models. In the future, GMSIM may be used in predicting counting statistics of three G-M dead time models, which are paralyzable, non-paralyzable and hybrid models.

Research for enhanced counting algorithm of optical pill counting machine (광학센서를 이용한 알약계수기의 계수알고리즘 향상에 관한 연구)

  • 홍인기;원민규;이순걸
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.683-686
    • /
    • 2002
  • It is fundamental to count and pack the pills in the medicine manufacture field but those tasks are time and labor consuming. Thus, the need fur automation of those tasks is necessarily getting increased in order to get effective mass production. It Is significant to perceive pills quickly and precisely. There were many trials for this processing but the performance of the existing counting machines varies about size, shape and dispersion tendency of pills. In this paper, the authors try to improve the counting performance of a pill counting machine that has optical sensors with the neural network. The passing signal of pill is acquired with optical sensor and the passage signal of the pill is extracted as input patterns. The gradient and integration of signal during passing time and the time keeping the pill interrupt the light from the LED are used as characteristic feature. The back propagation and perception algorithm are used for training. Experimental results with several pills show that the designed algorithm is a little bit effective to reduce the noise effect which is generated from interference among the machine components and unreliable environment.

  • PDF

Counting Strategies in Radioactivity Measurement for the Monitoring and Screening (방사능 존재확인과 정량분석시 최적화된 측정시간의 결정을 위한 계측전략)

  • Seo, Kyung-Won
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.2
    • /
    • pp.65-74
    • /
    • 1998
  • One of the important things in low level radioactivity measurement is determination of the optimized counting time. Counting strategy has to be established, in order to count the radioactivity of the sample by condition of optimized measurement. There were three kinds of counting strategies in this report ; about fixed time, about fixed count, to compared sample, background, and reference level. The best of them was satisfied rendition to give about condition of instrument and process, as an example, efficiency of detector, counter capacity, maximum and average background count rate of counter, reference level and limit of derision and detection, etc. Therefore, we can decide the optimized counting time in the screening and monitoring. And we can save the time for courting the sample of course the data of count will be counted by optimized accuracy finally, in rountine measurement of radioactivity these strategies will be used available.

  • PDF

A Study on Electronic Circuit for Liwe-Time Correction in Multi-Channel Analyzer : Survey and Analysis (방사선 스펙트럼 계측기 (Multi-Channel Analyzer)의 Live-Time 보상회로에 관한 연구)

  • Hwang, I.K.;Kwon, K.H.;Song, S.J.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.784-791
    • /
    • 1995
  • This paper describes the counting-loss problem for radiation measurement Multi-channel analyzers and spectrometers adopt various techniques for compensation for counting-losses in process-ing the radiation pulses from a detector. Researchers hate tried to seek the best solution for the problem. However, any absolute solution has not been reached and vendors of radiation instruments use their own algorithms individually. This survey explains the various compensation algorithms with electronic implementation approach. Shortcomings and merits of each algorithm are also reviewed and a direction is suggested of the recommendable development strategy for counting-loss compensation.

  • PDF

A novel method for cell counting of Microcystis colonies in water resources using a digital imaging flow cytometer and microscope

  • Park, Jungsu;Kim, Yongje;Kim, Minjae;Lee, Woo Hyoung
    • Environmental Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.397-403
    • /
    • 2019
  • Microcystis sp. is one of the most common harmful cyanobacteria that release toxic substances. Counting algal cells is often used for effective control of harmful algal blooms. However, Microcystis sp. is commonly observed as a colony, so counting individual cells is challenging, as it requires significant time and labor. It is urgent to develop an accurate, simple, and rapid method for counting algal cells for regulatory purposes, estimating the status of blooms, and practicing proper management of water resources. The flow cytometer and microscope (FlowCAM), which is a dynamic imaging particle analyzer, can provide a promising alternative for rapid and simple cell counting. However, there is no accurate method for counting individual cells within a Microcystis colony. Furthermore, cell counting based on two-dimensional images may yield inaccurate results and underestimate the number of algal cells in a colony. In this study, a three-dimensional cell counting approach using a novel model algorithm was developed for counting individual cells in a Microcystis colony using a FlowCAM. The developed model algorithm showed satisfactory performance for Microcystis sp. cell counting in water samples collected from two rivers, and can be used for algal management in fresh water systems.

Determination of counting efficiency considering the biodistribution of 131I activity in the whole-body counting measurement

  • MinSeok Park ;Jaeryong Yoo;Minho Kim ;Won Il Jang ;Sunhoo Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.295-303
    • /
    • 2023
  • Whole-body counters are widely used to assess internal contamination after a nuclear accident. However, it is difficult to determine radioiodine activity due to limitations in conventional calibration phantoms. Inhaled or ingested radioiodine is heterogeneously distributed in the human body, necessitating time-dependent biodistribution for the assessment of the internal contamination caused by the radioiodine intake. This study aims at calculating counting efficiencies considering the biodistribution of 131I in whole-body counting measurement. Monte Carlo simulations with computational human phantoms were performed to calculate the whole-body counting efficiency for a realistic radioiodine distribution after its intake. The biodistributions of 131I for different age groups were computed based on biokinetic models and applied to age- and gender-specific computational phantoms to estimate counting efficiency. After calculating the whole-body counting efficiencies, the efficiency correction factors were derived as the ratio of the counting efficiencies obtained by considering a heterogeneous biodistribution of 131I over time to those obtained using the BOMAB phantom assuming a homogeneous distribution. Based on the correction factors, the internal contamination caused by 131I can be assessed using whole-body counters. These correction factors can minimize the influence of the biodistribution of 131I in whole-body counting measurement and improve the accuracy of internal dose assessment.

Fluorescence photon counting rate as a function of dye concentration: Effect of dead time of photon detector (색소 농도에 따른 형광 광자의 계수율 : 광자 검출기의 dead time 효과)

  • 고동섭
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.4
    • /
    • pp.353-355
    • /
    • 1997
  • A single molecule detection system, which consists of confocal fluorescence microscope and single photon counter, has been used to observe the dye concentration dependence of photon counting rate. With increasing concentration, a saturation effect of counting is observed and demonstrated on the basis of the dead time of photon detector. The equations presented here show the relations between the counting rate and some parameters such as probe volume, quantum efficiency of detector, and fluorescence photon number entered onto detector. The signal-to-noise ratio is also discussed briefly.

  • PDF

Development of People Counting Algorithm using Stereo Camera on NVIDIA Jetson TX2

  • Lee, Gyucheol;Yoo, Jisang;Kwon, Soonchul
    • International journal of advanced smart convergence
    • /
    • v.7 no.3
    • /
    • pp.8-14
    • /
    • 2018
  • In the field of surveillance cameras, it is possible to increase the people detection accuracy by using depth information indicating the distance between the camera and the object. In general, depth information is obtained by calculating the parallax information of the stereo camera. However, this method is difficult to operate in real time in the embedded environment due to the large amount of computation. Jetson TX2, released by NVIDIA in March 2017, is a high-performance embedded board with a GPU that enables parallel processing using the GPU. In this paper, a stereo camera is installed in Jetson TX2 to acquire depth information in real time, and we proposed a people counting method using acquired depth information. Experimental results show that the proposed method had a counting accuracy of 98.6% and operating in real time.

SELECTIVE DETECTION OF VIABLE ENTEROCOCCUS FAECALIS USING PROPIDIUM MONOAZIDE IN COMBINATION WITH REAL-TIME PCR (Propidium monoazide와 real-time PCR을 이용한 살아있는 Enterococcus faecalis의 선택적인 검출)

  • Kim, Sin-Young;Lee, Seung-Jong;Kim, Eui-Seong;Seo, Deog-Gyu;Song, Yoon-Jung;Jung, Il-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.6
    • /
    • pp.537-544
    • /
    • 2008
  • Polymerase chain reaction (PCR) can detect bacteria more rapidly than conventional plate counting. However DNA-based assays cannot distinguish between viable and dead cells due to persistence of DNA after cells have lost their vitality. Recently, propidium monoazide (PMA) treatment has been introduced. The purpose of this study is to evaluate the applicability of the PMA treatment and real-time PCR method for cell counting in comparison with plate counting and to evaluate the antibacterial efficacy of 2% CHX on E. faecalis using PMA treatment in combination with real-time PCR. Firstly, to elucidate the relationship between the proportion of viable cells and the real-time PCR signals after PMA treatment, mixtures with different ratios of viable and dead cells were used. Secondly, relative difference of viable cells using PMA treatment in combination with real-time PCR was compared with CFU by plate counting. Lastly, antibacterial efficacy of 2% CHX on E. faecalis was measured using PMA treatment in combination with real-time PCR. The results were as follows : 1. Ct value increased with decreasing proportion of viable E. faecalis. 2. There was correlation between viable cells measured by real-time PCR after PMA treatment and CFU by plate counting until Optical density (OD) value remains under 1.0. However, viable cells measured by real-time PCR after PMA treatment have decreased at 1.5 of OD value while CFU kept increasing. 3. Relative difference of viable E. faecalis decreased more after longer application of 2% CHX.