• Title/Summary/Keyword: count of discharge

Search Result 76, Processing Time 0.027 seconds

Characteristics in W-EDM of Tungsten Carbide (초경합금의 와이어 방전가공에 의한 특성)

  • 맹민재
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.7-13
    • /
    • 2001
  • Wire electrical discharge machining experiments in conducted to investigate characteristics of acoustic emission (AE) and electrical discharge energy due to current peak (I$_{p}$), pulse on time($\tau$/on/). The AE signals are obtained with a sensor attached to workpiece side. Machining states are identified with scanning electron microscopy and residual stress analyzer. It is demonstrated that the residual stress provide reliable informations about the machining states. Moreover, machining states can be detected successfully using both the residual stress and AE count rate.e.

  • PDF

Development of a Milk Filtering System for Decreasing Somatic Cell Count (체세포수 감소를 위한 우유여과시스템 개발)

  • Chang, Jin-Tack;Kim, Wan-Young;Yeo, Joon-Mo;Kang, In-Chul;Lee, Seung-Kee
    • Journal of Animal Environmental Science
    • /
    • v.20 no.1
    • /
    • pp.15-20
    • /
    • 2014
  • The present study was conducted to develop a milk filtering system for decreasing somatic cell count (SCC) in bulk tank milk. The pore sizes of the filter were 0.1, 0.3, 0.4, 0.5 and $0.8{\mu}m$. The rate of SCC reduction of $1^{st}$ grade milk on $0.1{\mu}m$ filter was 76% and significantly higher than other treatments. The rates of SCC reduction for 0.3, 0.4, 0.5 and $0.8{\mu}m$ were 35, 32, 18 and 6.4%, respectively. The effects of the milk filtering system on bacterial count and milk fat content were minimal. The milk flow rates per minute between the filter sizes were similar. But discharge pressures were increased as the pore size of the filter decreased. In conclusion, Considering the rate of SCC reduction, discharge pressure and cost, $0.4{\mu}m$ filter could be recommended.

A Complex Noise Suppression Algorithm for On-line Partial Discharge Diagnosis Systems (운전중 부분방전 진단시스템을 위한 복합 잡음제거 기법)

  • Yi, Sang-Hwa;Youn, Young-Woo;Choo, Young-Bae;Kang, Dong-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.342-348
    • /
    • 2009
  • This paper introduces a novel denoising algorithm for the partial-discharge(PD) signals from power apparatuses. The developed algorithm includes three kinds of specific denoising sub-algorithms. The first sub-algorithm uses the fuzzy logic which classifies the noise types in the magnitude versus phase PD pattern. This sub-algorithm is especially effective in the rejection of the noise with high and constant magnitude. The second one is the method simply removing the pulses in the phase sections below the threshold count in the count versus phase pattern. This method is effective in removing the occasional high level noise pulses. The last denoising sub-algorithm uses the grouping characteristics of PD pulses in the 3D plot of the magnitude versus phase versus cycle. This special technique can remove the periodical noise pulses with varying magnitudes, which are very difficult to be removed by other denoising methods. Each of the sub-algorithm has different characteristic and shows different quality of the noise rejection. On that account, a parameter which numerically expresses the noise possessing degree of signal, is defined and evaluated. Using the parameter and above three sub-algorithms, an adaptive complex noise rejection algorithm for the on-line PD diagnosis system is developed. Proposed algorithm shows good performances in the various real PD signals measured from the power apparatuses in the Korean plants.

A Study on the Texturing Characteristics of Work Roll and Variation of Strip Surface Roughness in 4-Hi Mill (4단 압연기용 작업롤의 표면조도가공 특성과 판면조도 변화에 관한 연구)

  • Kim, Moon Kyung;Jeon, Eon Chan;Kim, Soon Kyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.7
    • /
    • pp.167-175
    • /
    • 1996
  • Work roll wear in the cold rolling of steel strip is strongly affected by rolling materials, rolling conditions and lubrication. Tests were performed to find the effects of rolling materials under the same lubricating conditions. Surface roughness of cold rolled steel strip as well as the coating technique itself is quite improtant in obtaining high image clarity of electronic products and car outer panels. Therefore this paper reviews for improvement of roughness and peak count about the surface of Cr coated work roll is investigated from the actual temper mill. The conclusions were obtained as follows; 1) Work roll wear in the cold rolling of steel strip is strongly affected by carbon contents of rolling materials, but there is not a separating force and total reduction ratio. 2) The roughness of strip surface is larger in the direction of width than in roll direction. 3) The electro-discharge textured roll has more uniform roughness distribu- tion than shot blasted roll and it's life time is two times longer than shot blasted because it has more harmonic wave roughness, and the higher peak count of surface roughness. 4) The life time of Cr coated work roll is 2 times longer than that of shot blasted work roll and variation of peak count, roughness and life time of Cr coated work roll is similar to electro-discharge texturing work roll. 5) The proper Cr coating thickness is 10 .mu. m at the work roll of temper mill.

  • PDF

Properties and classification of air discharge by Kohonen network (기중방전의 특성분석과 Kohonen network에 의한 방전원의 패턴분류)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.704-707
    • /
    • 1999
  • Partial discharge(PD) in air insulated electric power systems is responsible for considerable power lossesfrom high voltage transmission lines. PD in air often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge and may give rise to interference in ommunication systems. PD can indicate incipient failure. Thus understanding and classification of PD in air is very important to discern source of PD. In this paper, we investigated PD in air by using statical method. We classified air discharge with corona, surface discharge and cavity discharge by source of discharge. we used the mean pulse-height phase distribution $H_{qmean}(\psi)$, the max pulse-height phase distribution $H_{qmax}(\psi)$ , the pulse count phase distribution $H_n(\psi)$ and the max pulse height vs. repetition rate $H_{q}(n)$ for analysis PD pattern. We used statistical operators, such as skewness(S+. S-1, kurtosis(K+, K-), mean phase(AP+. AP-), cross-correlation factor(CC) and asymmetry from the distribution.

  • PDF

Recognition of Discharge Sources using Neural Networks (신경회로망을 이용한 방전원 인식에 관한 연구)

  • Lee, Woo-Young;Kang, Dong-Sik;Chon, Young-Kap
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1540-1542
    • /
    • 1994
  • This paper describes an experimental study of pattern recognition of partial discharge for three different discharge sources by using neural network(NN) system. The NN system is three layer feedforward connections and its learning method is a backpropagation algorithm incorporating an external teacher signal. Input information for NN is a statistical parameters of a discharge magnitude and the number of pulse count. After learning three typical input patterns, NN system offers good discrimination between different defects.

  • PDF

Comparison of Fish Species Composition by Trammel Net at the Intake and Discharge of Weolseong Nuclear Power Plant (월성원자력발전소 취수구 및 배수구에서 삼중자망으로 채집된 어류의 종조성 비교)

  • Ryu, Jung-Hwa;Yoo, Jae Myung;Kim, Jin-Koo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.49 no.6
    • /
    • pp.883-888
    • /
    • 2016
  • We investigated fish species composition seasonally at the intake and discharge of Weolseong Nuclear Power Plant (WS-NPP) from February to November 2008 using a trammel net. At the intake, 121 individuals belonging to 28 species were collected, and 157 fish from 34 species were sampled at the WS-NPP discharge. Dominant species at the intake were Chelidonichthys spinosus (17.2%), Scomber japonicus (11.5%) and Ditrema temminckii (8.2%) at the intake, while Sillago japonica (18.5%), Chelidonichthys spinosus (13.4%) and Konosirus punctatus (8.3%) dominated at the discharge. The species count and diversity index at the discharge were highest during winter, whereas those at the intake were highest during spring, perhaps due to warm seawater at the discharge site. This study is the first to reveal an effect of effluent water on the aggregation of warm water fish species during winter.

Association between Initial Chest CT or Clinical Features and Clinical Course in Patients with Coronavirus Disease 2019 Pneumonia

  • Zhe Liu;Chao Jin;Carol C. Wu;Ting Liang;Huifang Zhao;Yan Wang;Zekun Wang;Fen Li;Jie Zhou;Shubo Cai;Lingxia Zeng;Jian Yang
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.736-745
    • /
    • 2020
  • Objective: To identify the initial chest computed tomography (CT) findings and clinical characteristics associated with the course of coronavirus disease 2019 (COVID-19) pneumonia. Materials and Methods: Baseline CT scans and clinical and laboratory data of 72 patients admitted with COVID-19 pneumonia (39 men, 46.2 ± 15.9 years) were retrospectively analyzed. Baseline CT findings including lobar distribution, presence of ground glass opacities, consolidation, linear opacities, and lung severity score were evaluated. The outcome event was recovery with hospital discharge. The time from symptom onset to discharge or the end of follow-up (for those remained hospitalized) was recorded. Data were censored in events such as death or discharge without recovery. Multivariable Cox proportional hazard regression was used to explore the association between initial CT, clinical or laboratory findings, and discharge with recovery, whereby hazard ratio (HR) values < 1 indicated a lower rate of discharge at four weeks and longer time until discharge. Results: Thirty-two patients recovered and were discharged during the study period with a median length of admission of 16 days (range, 9 to 25 days), while the rest remained hospitalized at the end of this study (median, 17.5 days; range, 4 to 27 days). None died during the study period. After controlling for age, onset time, lesion characteristics, number of lung lobes affected, and bilateral involvement, the lung severity score on baseline CT (> 4 vs. ≤ 4 [reference]: adjusted HR = 0.41 [95% confidence interval, CI = 0.18-0.92], p = 0.031) and initial lymphocyte count (reduced vs. normal or elevated [reference]: adjusted HR = 0.14 [95% CI = 0.03-0.60], p = 0.008) were two significant independent factors that influenced recovery and discharge. Conclusion: Lung severity score > 4 and reduced lymphocyte count at initial evaluation were independently associated with a significantly lower rate of recovery and discharge and extended hospitalization in patients admitted for COVID-19 pneumonia.

Changes in Nutritional Status according to Biochemical Assay, Body Weight, and Nutrient Intake Levels in Gastrectomy Patients (위절제 환자들의 혈액의 생화학적 지표, 체중 및 영양소 섭취 변화에 관한 추적 연구)

  • Yu, Eun-Joo;Kang, Ju-Hee;Yoon, Sun;Chung, Hye-Kyung
    • Journal of the Korean Dietetic Association
    • /
    • v.18 no.1
    • /
    • pp.16-29
    • /
    • 2012
  • The purpose of this study was to investigate the changes in nutritional status of gastrectomy patients. The anthropometric and biochemical data were measured at pre-operation, at discharge, 1 month after discharge, and 3 months after discharge. Nutrient intake levels, nutrients adequacy ratio (NAR), mean adequacy ratio (MAR), and the proportion of patients with intake levels inferior to those of dietary reference intakes (DRIs) were analyzed at discharge, 1 month after discharge, and 3 months after discharge. Finally, the data on 23 patients (15 male and 8 female) were collected and used for statistical analysis. Fifteen patients underwent subtotal gastrectomy, and 8 patients underwent total gastrectomy. Compared to pre-operation, body weight and body mass index of subjects significantly decreased at discharge, 1 month after discharge, and 3 months after discharge (P<0.001). Serum albumin (P<0.001), total lympocyte count (P<0.001), total cholesterol (P<0.001), hemoglobin (P<0.001), hematocrit (P<0.001), and mean corpuscular hemoglobin concentration (P<0.05) were significantly different between pre-operation, at discharge, 1 month after discharge, and 3 months after discharge. The proportions of patients with lower nutrient intake levels than DRIs were substantial. MAR at discharge, 1 month after discharge, and 3 months after discharge were 0.70, 0.80 and 0.91, respectively. Especially, the NARs of folate, niacin, vitamin $B_2$, vitamin C, and zinc were all low. Considering the various nutritional problems of gastrectomy patients, systematic medical nutrition therapy is needed after gastrectomy.

The Analysis of Corona Discharge of Surface Flashover Model for Aging Diagnosis of Power Facility (전력설비의 열화 진단을 위한 연면방전 모델에서의 코로나 방전 특성 분석)

  • Pang, Man-Sik;Choi, Jae-Hyeong;Kim, Woo-Jin;Kim, Young-Seok;Kim, Sang-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.4
    • /
    • pp.314-318
    • /
    • 2011
  • Recently, ultrasound, infrared detector, V-I characteristic, gas analysis, UV (ultra-violet rays) camera etc. is used as inspections and diagnoses of the safety of power equipment. Especially, UV camera have attracted a great deal of interest from the view point of easy judgement. UV camera is used corona discharge. One of the most important and difficult problems to be solved filer design, materials and corona discharge. This paper is studied on the temperature characteristics, UV generation and shape analysis and corona pulse count according to the electrode distance and applied voltage. Also, Corona discharge characteristics in air are analyzed using prototype UV camera of Korea. UV generation due to surface discharge of AC is higher than that of DC.