• Title/Summary/Keyword: corrosion prevention

Search Result 154, Processing Time 0.024 seconds

Leakage Prevention of Mechanical Seal in a Feed Water Pumpof Power Plant with Oxygen Water Treatment (산소주입 수처리 발전소용 급수펌프 밀봉장치의 누설방지)

  • Shin, Jung-Gook;Moon, Seung-Jae;Yoo, Hoseon
    • Plant Journal
    • /
    • v.7 no.1
    • /
    • pp.56-63
    • /
    • 2011
  • The identifying cause of leakage problems on mechanical seal in a feed water pump of power plant have been difficult because of technical limits of domestic mechanical seal manufacturer and the various conditions of power plants. This paper can get a conclusion through the consideration study and experiment test of mechanical seal characteristics of feed water pump depending on oxygen treatment as follows. The oxygen treatment increase dissolved oxygen and cause a corrosion on the mechanical seal stationary ring composed of antimony as well as leakage problems. For solving leakage problems of seal, to eliminate dissolved oxygen in the cooling water of seal with hydrazine injection can prevent leakage problems of mechanical seal in feed water pump.

  • PDF

A Study on the Development of ppb Level Dissolved Oxygen Measuring Technology using Clark Cell (Clark Cell을 이용한 ppb Level 용존산소 측정기술 개발에 관한 연구)

  • 정경열;이후락;동은석;이수태;류길수
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.197-201
    • /
    • 2001
  • Measuring of the dissolved oxygen is widely used for the environmental control of natural waters, sewage waste treatment, medical and biochemical studies, soil husbandry, food and drug process control, and prevention of corrosion in boilers. Especially, a power plants need special management for preventing accidents from corrosion, therefore, it is essential to measure the concentration of dissolved oxygen in real-time. In this paper we present a method of measuring dissolved oxygen very accurately up to ppb units. This method, called polarographic method, is based on the measures of the electric current generated by the oxidation process in cathode and de-oxidation process in anode, assuming that the amount of the current is proportional to the density of dissolved oxygen.

  • PDF

DATA LOGGER APPARATUS FOR MEASUREMENT STRAY CURRENT OF SUBWAY AND POWER LINE (지하철과 전력선의 누설전류 측정을 위한 저장형 데이터 계측장치)

  • Bae, Jeong-Hyo;Ha, Yun-Cheol;Ha, Tae-Hyeon;Lee, Hyeon-Gu;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.731-734
    • /
    • 2003
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so. In this paper, results of development about data logger apparatus for measurement stray current of subway and power line are presented.

  • PDF

Two-dimensional water seepage monitoring in concrete structures using smart aggregates

  • Zou, Dujian;Li, Weijie;Liu, Tiejun;Teng, Jun
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.2
    • /
    • pp.313-323
    • /
    • 2018
  • The presence of water inside concrete structures is an essential condition for the deterioration of the structures. The free water in the concrete pores and micro-cracks is the culprit for the durability related problems, such as alkali-aggregate reaction, carbonation, freeze-thaw damage, and corrosion of steel reinforcement. To ensure the integrity and safe operation of the concrete structures, it is very important to monitor water seepage inside the concrete. This paper presents the experimental investigation of water seepage monitoring in a concrete slab using piezoelectric-based smart aggregates. In the experimental setup, an $800mm{\times}800mm{\times}100mm$ concrete slab was fabricated with 15 SAs distributed inside the slab. The water seepage process was monitored through interrogating the SA pairs. In each SA pair, one SA was used as actuator to emit harmonic sine wave, and the other was used as sensor to receive the transmitted stress wave. The amplitudes of the received signals were able to indicate the water seepage process inside the concrete slab.

Variations of Mechanical Properties and Corrosion Rate with Melting Conditions and Alloying Elements in High Silicon Cast Irons (용해조건 및 합금원소 첨가에 따른 고규소 내산주철의 기계적 성질 및 부식속도의 변화)

  • Kim, Jung-Chul;Han, Dong-Woon;Baik, Jin-Hyun;Baik, Seung-Han;Moon, Byung-Moon;Shin, Je-Sik;Lee, Young-Kuk
    • Journal of Korea Foundry Society
    • /
    • v.24 no.4
    • /
    • pp.209-216
    • /
    • 2004
  • High silicon cast irons(HSCI) with the high acid resistance have been used for the prevention of acid corrosion occurring in various structures under acid conditions. However, the HSCI is only known as one of materials which have high acid resistance, but few work has dealt with this material in domestic. Therefore, in this study, the acid resistance of various cast irons with alloying elements and melting conditions have been examined, and studied the influences of the matrix structures, mechanical properties and morphologies of graphite. The results obtained in this study are as follows : In case of melting temperature, the mechanical properties of specimen manufactured with high temperature of $1650^{\circ}C$ showed higher value because the inclusion and impurity were removed. In case of pouring temperature, the mechanical properties of specimen fabricated below $1350^{\circ}C$ of pouring temperature showed higher value because the amount of gas absorption from atmosphere decreased during the solidification time. The corrosion rate decreased with increase in Si content. On the other hand, Mn addition appeared an opposite trend with Si.

Field Investigation of Chloride Penetration and Evaluation of Corrosion Characteristics for Deicer (염화물 침투 현장조사 및 제설제에 따른 부식특성)

  • Yang, Eun-Ik;Kim, Myung-Yu;Park, Hae-Geun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.47-52
    • /
    • 2008
  • Deicer has been generally used for prevention of a road freezing in winter, and the usage amount is increasing every year. However, deicer may induce the decrease of bond strength, surface scaling, and environmental pollution. In this study, the field test was performed to investigate the deterioration of concrete road structures used for 17 years. And, the corrosion resistance characteristics were compared for the existing deicer and eco-friendly deicer. According to the field test results, the penetration depth of limit chloride amount was about 40mm, and the average concentration of chloride was $3.45kg/m^3$ at the surface of structures. On the contrary, the carbonation depth was slight. The penetration depth of eco-friendly deicer was less than the existing deicer, and the corrosion resistance of eco-friendly deicer was higher.

The Assessment for Coupling Integrity of Pressurizer Support Bolting (가압기 지지대 볼트 연결부의 건전성 평가에 관한 연구)

  • Cho, Nam-Jin;Kim, Woo-Chang;Kim, Hak-Joong
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.26-31
    • /
    • 2013
  • In nuclear power plant, anchor bolts for pressurizer supports are sufficiently used in terms of safety reason, but field inspections have reported that some bolts exceed the limit of their allowable hardness. Because the high level of hardness may lead to failures due to the stress corrosion or fracture toughness, a regular inspection is required for the bolts in nuclear power plant. Thus, this research measures the hardness of bolts currently used in pressurizer supports and then estimates maximum allowable stresses preventing failures by stress corrosion and fracture toughness. Using the ANSYS program, the stresses of the bolts in the regular condition and accidental condition have been calculated, and the possible maximum stress has been compared with the estimated allowable stresses. From the results, the stresses of bolts in the accidental condition satisfy the allowable safety stress from the stress corrosion failure. However, in the future, it shall be needed to consider the reflection of the structure assembling method on the assembling procedure to ensure the pressurizer integrity during maintenance period time.

Wireless structural health monitoring of bridges: present and future

  • Hoult, Neil A.;Fidler, Paul R.A.;Hill, Peter G.;Middleton, Campbell R.
    • Smart Structures and Systems
    • /
    • v.6 no.3
    • /
    • pp.277-290
    • /
    • 2010
  • Internationally the load carrying capacity of bridges is decreasing due to material deterioration while at the same time increasing live loads mean that they are often exposed to stresses for which they were not designed. However there are limited resources available to ensure that these bridges are fit for purpose, meaning that new approaches to bridge maintenance are required that optimize both their service lives as well as maintenance costs. Wireless sensor networks (WSNs) provide a tool that could support such an optimized maintenance program. In many situations WSNs have advantages over conventional wired monitoring systems in terms of installation time and cost. In order to evaluate the potential of these systems two WSNs were installed starting in July 2007 on the Humber Bridge and on a nearby approach bridge. As part of a corrosion prevention strategy, a relative humidity and temperature monitoring system was installed in the north anchorage chambers of the main suspension bridge where the main cables of the bridge are anchored into the foundation. This system allows the Bridgemaster to check whether the maximum relative humidity threshold, above which corrosion of the steel wires might occur, is not crossed. A second WSN which monitors aspects of deterioration on a reinforced concrete bridge located on the approach to the main suspension bridge was also installed. Though both systems have provided useful data to the owners, there are still challenges that must be overcome in terms of monitoring corrosion of steel, measuring live loading and data management before WSNs can become an effective tool for bridge managers.

Performance assessment of polymeric filler and composite sleeve technique for corrosion damage on large-diameter water pipes (대구경 상수도관 부식 손상부의 고분자 필러와 복합슬리브 성능 평가)

  • Ho-Min Lee;Jeong-Soo Park;Jeong-Joo Park;Cheol-Ho Bae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.4
    • /
    • pp.203-214
    • /
    • 2023
  • In this study, the physical properties and fracture characteristics according to the tensile load are evaluated on the materials of the polymeric filler and carbon fiber-based composite sleeve technique. The polymeric filler and the composite sleeve technique are applied to areas where the pipe body thickness is reduced due to corrosion in large-diameter water pipes. First, the tensile strength of the polymeric filler was 161.48~240.43 kgf/cm2, and the tensile strength of the polyurea polymeric filler was relatively higher than that of the epoxy. However, the tensile strength of the polymeric filler is relatively very low compared to ductile cast iron pipes(4,300 kgf/cm2<) or steel pipes(4,100 kgf/cm2). Second, the tensile strength of glass fiber, which is mainly used in composite sleeves, is 3,887.0 kgf/cm2, and that of carbon fiber is up to 5,922.5 kgf/cm2. The tensile strengths of glass and carbon fiber are higher than ductile cast iron pipe or steel pipe. Third, when reinforcing the hemispherical simulated corrosion shape of the ductile cast iron pipe and the steel pipe with a polymeric filler, there was an effect of increasing the ultimate tensile load by 1.04 to 1.06 times, but the ultimate load was 37.7 to 53.7% compared to the ductile cast iron or steel specimen without corrosion damage. It was found that the effect on the reinforcement of the corrosion damaged part was insignificant. Fourth, the composite sleeve using carbon fiber showed an ultimate load of 1.10(0.61T, 1,821.0 kgf) and 1.02(0.60T, 2,290.7 kgf) times higher than the ductile cast iron pipe(1,657.83 kgf) and steel pipe(2,236.8 kgf), respectively. When using a composite sleeve such as fiber, the corrosion damage part of large-diameter water pipes can be reinforced with same level as the original pipe, and the supply stability can be secured through accident prevention.

Study on the Sandblast Machine in Painting of Steel Structures for Environmental Pollution Prevention (공해방지를 위한 강구조물의 도장용 샌드블라스트 장치에 관한 연구)

  • 임우조;황태호;이진열
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.47-52
    • /
    • 1996
  • 본 연구에서는 각종 강구조물의 도장전 샌드블리스트 작업에 다른 공해를 방지하기 위해, 모래-물의 2상류를 분사할 수 있는 샌드블라스트 장치를 제작하여, 2상류 분사에 따른 마멸-부식(wear-corrosion)특성과 slurry erosion에 의한 anchor pattern 및 침식-마멸거동을 고찰하고, 물에 의한 강구조물의 부식방지를 위한 부식억제제가 강구조물의 도막에 미치는 방식특성을 구명함으로써 공해방지, 부식손상 및 산업의 국제경쟁력 향상에 기여하고자 한다.

  • PDF