• Title/Summary/Keyword: correlation measurement

Search Result 3,265, Processing Time 0.038 seconds

Measurement of Surface Temperature for Real Time Monitoring of the GMA Welding Processes (GMA용접공정의 실시간 모니터링을 위한 표면온도 측정)

  • 부광석;조형석
    • Proceedings of the KWS Conference
    • /
    • 1994.10a
    • /
    • pp.111-114
    • /
    • 1994
  • This paper describes a method to measure a weldment surface temperature for estimating variations of the weld pool size in the gas metal arc(GMA) welding processes. An Infrared sensing system is designed to measure the radiation emitted from the top surface of the weldment, The interference effect of the electric arc to the measurement is rejected by detecting the low peaks of the noisy signal. An optimizing criterion, in which the correlation between the weld quality and the measured temperature is maximized, is also proposed to determine the optimal measurement location.

  • PDF

Comparison of Growth and Allometric Change of Stand and Dominant Trees in Pinus koraiensis Plantation over 34 Years

  • Seo, Yeongwan;Lee, Daesung;Chhorn, Vireak;Choi, Jungkee
    • Journal of Forest and Environmental Science
    • /
    • v.34 no.3
    • /
    • pp.235-241
    • /
    • 2018
  • This study was conducted to find out the growth pattern of Pinus koraiensis plantation over 34 years, focusing on DBH, height, basal area and allometric change. Total increment (TI), mean annual increment (MAI) and correlation coefficient were calculated and compared with stand and dominants. Total increment and mean annual increment of both DBH and height of dominants were bigger than those of stand. The difference was apparently shown bigger in DBH than height. Unlike DBH and height the total increment and mean annual increment of basal area per hectare of dominants were distinctively smaller than those of stand. Furthermore MAI of dominant was increasing until age 42, while MAI of stand increased at early ages and then gradually decreased after culmination like MAIs of DBH and height. MAIs of basal area of dead trees at each measurement tended to increase until early age (18 years in this study), while it reached a peak and gradually decrease after that (21 years in this study). Correlation coefficient between DBH and height tended to decrease as both dominant and stand age and the difference between dominant and stand was not clearly shown over the measurement period. Correlation coefficients between DBH and crown width tended to decrease as the trees age and correlation coefficients of dominant were clearly shown smaller than that of stand. Correlation coefficients of height and crown width also was found to be similar to correlation coefficients between DBH and crown. Meanwhile correlation coefficient of height and crown width dropped more radically than coefficient of DBH and crown width as the trees age.

A Study on Flow Characteristics of a Ginseng Cleaner Using PIV (PIV에 의한 인삼세척기의 특성연구)

  • 송치성
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.140-145
    • /
    • 2000
  • The objective of experimental study is to apply simultaneous measurement by PIV(Particle Image Velocimetry) to high_speed flow characteristics within ginseng cleaner model. Three different kinds of flow rate(15.20 27ℓ/min) are selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. The instantaneous velocity distribution time0mean velocity distribution and velocity profile are represented quantitatively for the deeper understanding of the flow characteristics in a ginseng cleaner model.

  • PDF

ACOUSTIC TIME DOMAIN CORRELATION TECHNIQUE (ATDCT) IN OCEAN WAVE AND CURRENT OBSERVATION

  • I.N. Dienkulov;E.J. Kim;S.W. Yoon;V.V. Frolov
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.210-214
    • /
    • 1993
  • There are two general techniques to observe particle movements in fluid. One is the acoustic time domain correlation technique and another is the frequency domain Doppler-shift techniques. Both techniques were reviewed and mentioned their some merits and demerits in ocean wave and current observation. Some possible application of acoustic time domain correlation technique in ocean wind wave measurement was discussed.

  • PDF

Comparison of Real Time Nanoparticle Monitoring Instruments in the Workplaces

  • Ham, Seunghon;Lee, Naroo;Eom, Igchun;Lee, Byoungcheun;Tsai, Perng-Jy;Lee, Kiyoung;Yoon, Chungsik
    • Safety and Health at Work
    • /
    • v.7 no.4
    • /
    • pp.381-388
    • /
    • 2016
  • Background: Relationships among portable scanning mobility particle sizer (P-SMPS), condensation particle counter (CPC), and surface area monitor (SAM), which are different metric measurement devices, were investigated, and two widely used research grade (RG)-SMPSs were compared to harmonize the measurement protocols. Methods: Pearson correlation analysis was performed to compare the relation between P-SMPS, CPC, and SAM and two common RG-SMPS. Results: For laboratory and engineered nanoparticle (ENP) workplaces, correlation among devices showed good relationships. Correlation among devices was fair in unintended nanoparticle (UNP)-emitting workplaces. This is partly explained by the fact that shape of particles was not spherical, although calibration of sampling instruments was performed using spherical particles and the concentration was very high at the UNP workplaces to allow them to aggregate more easily. Chain-like particles were found by scanning electron microscope in UNP workplaces. The CPC or SAM could be used as an alternative instrument instead of SMPS at the ENP-handling workplaces. At the UNP workplaces, where concentration is high, real-time instruments should be used with caution. There are significant differences between the two SMPSs tested. TSI SMPS showed about 20% higher concentration than the Grimm SMPS in all workplaces. Conclusions: For nanoparticle measurement, CPC and SAM might be useful to find source of emission at laboratory and ENP workplaces instead of P-SMPS in the first stage. An SMPS is required to measure with high accuracy. Caution is necessary when comparing data from different nanoparticle measurement devices and RG-SMPSs.

Reproducibility Assessment of Skin Furrows Measurement using Facial Skin Photographing System (전안촬영시스템을 이용한 주름 측정의 재현성 평가)

  • Lee, Seung-Ryun;Lee, Yun-Kyu;Park, Seo-Young;Ko, Kyoung-Mo;Lee, Yoon-Kyoung;Kim, Jae-Su;Lee, Bong-Hyo;Lim, Seong-Chul;Jung, Tae-Young;Lee, Kyung-Min
    • Journal of Acupuncture Research
    • /
    • v.25 no.1
    • /
    • pp.187-197
    • /
    • 2008
  • Objectives : The purpose of this study was to assess the reproducibility of measurement of facial skin furrows using a facial skin photographing system. Methods : Subjects were 19 patients who visited the department of acupuncture and moxsibustion, at the hospital of Oriental medical college, at Daegu Haany University for the cosmetic acupuncture treatment during August 2007 to 31th August 2007. The facial skin photograph of each participant was analyzed a total of six times in two days using DM-3(a facial skin photographing system). The square and counts of skin furrows were also measured for each one. As the statistical method, Pearson's correlation coefficient and repeated measured ANOVA were used. Results : The Pearson's correlation coefficient, it showed significantly high correlation in both the square and count of skin furrows for each analysis time. Repeated measured ANOVA showed no significant differences among analyses in both square and count of skin furrows. Conclusions : This study reveales that the measurement of the count and square of facial skin furrows by facial skin photograph analysis has high reproducibility. DM-3(a facial skin photographing system) can be useful for the evaluation of facial skin furrows in facial cosmetic acupuncture.

  • PDF

Comparison of LDL-Cholesterol direct measurement with the estimate using various formula

  • Kwon, Se Young;Na, Young-Ak
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.3
    • /
    • pp.103-111
    • /
    • 2012
  • Low-Density Lipoprotein cholesterol (LDLC) is the most important marker for the treatment of hyperlipidemia in NCEP-ATP III(National Cholesterol Education Program-Adult Treatment Panel III) guideline. Therefore, LDL cholesterol is pathologically meaningful, accurate measurement should be a top priority. Currently, LDLC is directly measured in most cases, but, the estimate is still used in mass health examination or screening test. This study is about the comparison of LDL-Cholesterol direct measurement with the estimate using various formula (Friedewald: [LDL-F=TC-HDL-TG/5], Nakajima: [LDL-N=TC-HDL-TG/4], Hattori: [LDL-H =0.94TC-0.94HDL-0.19TG], Puavilai: [LDL-P=TC-HDL-TG/6], Carvalho: [LDL-C=3(TC-HDL)/4]) for calculating more accurate value. We analyzed total cholesterol (TC), try-glyceride (TG), high-density lipoprotein cholesterol (HDLC), and LDLC levels of 210 subjects between June and November in 2011. Until now, the Friedewald formula is the most commonly used estimate for the LDLC. When Friedewald formula was applied, the correlation coefficient (r) was 0.940, showing high correlation. But, the result of the direct method was significantly different, compared with those of the Friedewald formula in triglyceride levels ${\geq}400mg/dL$(p<0.05). There was the highest correlation when we used LDL-P formula(r=0.947) in triglyceride levels <400 mg/dl. Also there was the lowest mean difference regardless of triglyceride level. Therefore, the study showed that TG/6 is more precise means of calculation than TG/5. On the other hand, the calculation of LDL-Cholesterol was underestimated, compared with direct measurement. It is necessary to have more data and modified Friedewald formula should be used for the accurate calculation.

  • PDF

A Study of the Strain Measurement for Al 6061-T6 Tensile Specimen using the Digital Image Correlation (디지털 이미지 상관관계를 이용한 Al 6061-T6 인장시험편의 변형률 측정에 관한 연구)

  • Kwon, Oh Heon;Kim, Sang Tae;Kang, Ji Woong
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.4
    • /
    • pp.26-32
    • /
    • 2013
  • A digital image correlation(DIC) method is a whole-field measurement technique that acquires surface displacements and strains from images information which characterized a random speckle as intensity grey levels. Recently years, this DIC method is being developed and used increasingly in various research. In this study, we tried to apply to aluminum alloy(Al 6061-T6) using DIC method and strain gauge. DIC results demonstrated the usefulness and ability to determine a strain. The test specimen used in this study was an aluminum alloy(Al 6061-T6, thickness 1 mm). For a strain measurement, a strain gauge was attached at the center of a specimen. A specimen was lightly sprayed with a white paint and a black dot pattern was sprayed on its fully dried white surface to obtain a random speckle. The experimental apparatus used to perform the tensile test consisted of universal dynamic tester(5 kN; T.O. Co.) under displacement speed of 0.5, 1.0 and 3.0 mm/min. A Model 5100 B Scanner(V. Co.) used to obtain a strain. A CCD camera connected to a PC uses to record the images of the specimen surface. After acquisition, the images were transferred to PC where the DIC software was implemented. An acquired image was evaluated by the DIC program. DIC method for displacement and strain was suggests and it results show a good consistent remarkably. DIC results demonstrated the usefulness and ability to determine surface strain was better than by using classical measurements. The strain field measurement using a DIC is so useful that it can be applied to map strain distributions at a full area. DIC method can evaluate a strain change so it can predict a location of fracture. The findings of the investigation suggest that the DIC method is an efficient and reliable tool for full-field monitoring and detailed damage characterization of materials.

Development of Multi-Frequency Impedance Measurement System for Acupuncture Points and Preliminary Report of Measurement Results (Multi-frequency 자극 방식을 이용한 생체 전기 임피던스 측정 시스템 설계 및 경혈의 전기적 특이성에 대한 고찰)

  • Kim, Soo-Byeong;Lee, Na-Ra;Lee, Seung-Wook;Choi, Jun-Young;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.29 no.1
    • /
    • pp.71-81
    • /
    • 2012
  • Objectives : The purpose of this paper was to suggest new diagnostic method that was to supersede the estimation of electrical properties at acupoints. Thus, we developed the multi- frequencies bioelectrical impedance measurement system so as to analyze the state of bio-ions in body fluid as body compositions, not skin impedance at acupoint. Methods : At low frequency, the current does not penetrate the cell membrane and at high frequency, the current passes through both intracellular and extracellular fluid because of the decreas of cell membrane impedance. To confirm the reflection of composition in extracellular fluid or intracellular fluid of segment such as acupoint, the system was developed to detect the acupoint potential between adjacent two points in the area of LU3, LU4 and LU9 using 5,50 and 200KHz. Results : The detected acupoint potential has been decreased according to elevation of frequency. As a result of correlation of left/right identical acupoint, we observed a high correlation of three types of acupoint potential at multi-frequencies. Moreover, we observed the low correlation at 5KHz, and that was a significant factor to be considered as unbalanced relationship of identical acupoints. Conclusions : On the basis of meridian theoretical point of view, we may infer the acupoint's physiological composition using the multi-frequencies bioelectrical impedance measurement system.

A Study on Correlation of the Results VFA Measured by CT Position with VFA Measured by InBody (CT 측정 위치에 따른 내장지방 면적과 Inbody로 측정한 내장지방 면적의 상관성 연구)

  • Lee, Sang Heon;Im, In Chul;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.691-698
    • /
    • 2019
  • The patients who visited the Health Promotion Center were compared between the visceral fat area according to CT fat measurement position and the visceral fat area measured by Inbody. In the CT measurement, the visceral fat area measured at the L4-5 and CT Umbilicus positions was not different regardless of gender. In addition, there was no difference between CT visceral fat area and Inbody visceral fat area in the correlation between visceral fat area according to CT measurement position and visceral fat area measured by Inbody. The highly correlated CT measurement position were male L4-5, L5-S1, female L3-4, L4-5, L5-S1, and Umbilicus. In addition, when studying the relationship between the inbody visceral fat area and CT visceral fat area regardless of gender, it is suggested to compare the visceral fat area at the CT L4-5 position.