• Title/Summary/Keyword: corrected data

Search Result 951, Processing Time 0.028 seconds

Evaluation of Contrast and Resolution on the SPECT of Pre and Post Scatter Correction (산란보정 전, 후의 SPECT 대조도 및 분해능 평가)

  • Seo, Myeong-Deok;Kim, Yeong-Seon;Jeong, Yo-Cheon;Lee, Wan-Kyu;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.127-132
    • /
    • 2010
  • Purpose: Because of limitation of image acquisition method and acquisition time, scatter correction cannot perform easily in SPECT study. But in our hospital, could provide to clinic doctor of scatter corrected images, through introduction of new generation gamma camera has function of simple scatter correction. Taking this opportunity, we will compare scatter corrected and non-scatter corrected image from image quality of point of view. Materials and Methods: We acquisite the 'Hoffman brain phantom' SPECT image and '1mm line phantom' SPECT image, each 18 times, with GE Infinia Hawkeye 4, SPECT-CT gamma camera. At first, we calculated each contrast from axial slice of scatter corrected and non-scatter corrected SPECT image of 'Hoffman brain phantom'. and next, calculated each FWHM of horizontal and vertical from axial slice of scatter corrected and non-scatter corrected SPECT image of '1mm line phantom'. After then, we attempted T test analysis with SAS program on data, contrast and resolution value of scatter corrected and non-scatter corrected image. Results: The contrast of scatter corrected image, elevated from 0.3979 to 0.3509. And the resolution of scatter corrected image, elevated from 3.4822 to 3.6375. p value were 0.0097 in contrast and <0.0001 in resolution. We knew the fact that do improve of contrast and resolution through scatter correction. Conclusion: We got the improved SPECT image through simple and easy way, scatter correct. We will expect to provide improved images, from contrast and resolution point of view. to our clinic doctor.

  • PDF

Contrast and geometric correction of non-standardized radiographs in digital subtraction radiography (디지털 공제술에서 비표준화 방사선사진의 대조도 및 기하학적 보정에 관한 연구)

  • Kim, Eun-Kyung
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.4
    • /
    • pp.797-809
    • /
    • 1998
  • The purposes of this study were to develop the computer program for the contrast and geometric correction in digital subtration radiography with the IDL (Interactive Data Language) and compare the results with this program for the correction of the non-standardized radiographs to those of standardized radiographs and those with "Emago" software, the commercial program for the correction. The procedures were written for the contrast correction and subtraction with the geometric correction, using IDL. 32 pairs of periapical radiographs of premolar and molar portion of two dry human mandibles were taken at two different occasions with XCP film holder(nonstandardized films) and another 32 pairs with customized XCP film holder(standardized films). Subtraction of standardized film pairs was performed. Subtraction after the contrast and geometric correction of non-standardized films was performed using the newly developed program and Emago software. Standard deviations of grey levels of the subtracted images by the newly developed program were compared with those of the standardized group and Emago-corrected group. Standard deviations of grey levels of new program-corrected group were much smaller than those of the Emago-corrected group (p<0.001) and slightly larger than those of standardized group (p<0.05). However, the difference was very minute. This study indicates that the newly developed program written with IDL may substitute the mechanical standardization for digital subtraction radiography.

  • PDF

Correlation Between Collimation-Corrected Peak Luminosity and Spectral Lag of Gamma-ray Bursts in the Source Frame

  • Chang, Heon-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.3
    • /
    • pp.253-258
    • /
    • 2012
  • We revisit the relation between the peak luminosity $L_{iso}$ and the spectral time lag in the source frame. Since gamma-ray bursts (GRBs) are generally thought to be beamed, it is natural to expect that the collimation-corrected peak luminosity may well correlate with the spectral time lag in the source frame if the lag-luminosity relation in the GRB source frame exists. With 12 long GRBs detected by the Swift satellite, whose redshift and spectral lags in the source frame are known, we computed $L_{0,H}$ and $L_{0,W}$ using bulk Lorentz factors ${\Gamma}_{0,H}$ and ${\Gamma}_{0,W}$ archived in the published literature, where the subscripts H and W represent homogeneous and wind-like circumburst environments, respectively. We have confirmed that the isotropic peak luminosity correlates with the spectral time lag in the source frame. We have also confirmed that there is an anti-correlation between the source-frame spectral lag and the peak energy, $E_{peak}$ (1 + z) in the source frame. We have found that the collimation-corrected luminosity correlates in a similar way with the spectral lag, except that the correlations are somewhat less tight. The correlation in the wind density profile seems to agree with the isotropic peak luminosity case better than in the homogeneous case. Finally we conclude by briefly discussing its implications.

Missing Data Imputation Using Permanent Traffic Counts on National Highways (일반국토 상시 교통량자료를 이용한 교통량 결측자료 추정)

  • Ha, Jeong-A;Park, Jae-Hwa;Kim, Seong-Hyeon
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.1 s.94
    • /
    • pp.121-132
    • /
    • 2007
  • Up to now Permanent traffic volumes have been counted by Automatic Vehicle Classification (AVC) on National Highways. When counted data have missing items or errors, the data must be revised to stay statistically reliable This study was carried out to estimate correct data based on outoregression and seasonal AutoRegressive Integrated Moving Average (ARIMA). As a result of verification through seasonal ARIMA, the longer the missed period is, the greater the error. Autoregression results in better verification results than seasonal ARIMA. Traffic data is affected by the present state mote than past patterns. However. autoregression can be applied only to the cases where data include similar neighborhood patterns and even in this case. the data cannot be corrected when data are missing due to low qualify or errors Therefore, these data shoo)d be corrected using past patterns and seasonal ARIMA when the missing data occurs in short periods.

Radar Data Correction for Long Distance Observation In Coastal Zone (해안지역 내 원거리 레이더관측자료의 보정에 관한 연구)

  • Ricardo S. TENORIO;Byung-Hyuk Kwon;Hong-Joo Yoon;Dong-In Lee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.5
    • /
    • pp.985-996
    • /
    • 2000
  • In the coastal zone, to draw up short and medium range weather forecasts, mesoscale pluviogenic systems coming from the sea have to be observed in real time. These observations use remote sensing. However, satellite remote sensing is not sufficient to describe pluviogenic systems; reference to radar long distance observations is indispensable. This paper deals with the corrections, which must be made to long distance radar data if the rainfall field is to be both accurately and quantitatively defined. The error due to vertical variation in the reflectivity factor can be corrected from estimation of the mean profiles or by a climatic adjustment method. Atten-uation in the propagation can be corrected by an iterative polarimetric method. These various correc-tions permit the distance validity limits of radar data to be extended.

  • PDF

Sea-Level Trend at the Korean Coast

  • Cho, Kwangwoo
    • Journal of Environmental Science International
    • /
    • v.11 no.11
    • /
    • pp.1141-1147
    • /
    • 2002
  • Based on the tide gauge data from the Permanent Service for Meau Sea Level (PSMSL) collected at 23 locations in the Korean coast, the long-term sea-level trend was computed using a simple linear regression fit over the recorded length of the monthly mean sea-level data. The computed sea-level trend was also corrected for the vertical land movement due to post glacial rebound(PGR) using the ICE-4G(VM2) model output. It was found that the PGR-corrected sea-level trend near Korea was 2.310 $\pm$ 2.220 mm/yr, which is higher than the global average at 1.0∼2.0mm/yr, as assessed by the Intergovernmental Panel on Climate Change(IPCC). The regional distribution of the long-term sea-level trend near Korea revealed that the South Sea had the largest sea-level rise followed by the West Sea and East Sea, respectively, supporting the results of the previous study by Seo et al. However, due to the relatively short record period and large spatial variability, the sea-level trend from the tide gauge data for the Korean coast could be biased with a steric sea-level rise by the global warming during the 20th century.

KOMPSAT2 TERMINAL POLAR STATION MASS PRODUCTION TEST

  • Kang, Ji-Hoon;Lee, Chol;Kim, Tae-Hoon;Ahn, Sang-Il
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.375-377
    • /
    • 2008
  • The KOMPSAT2 Terminal Polar Station was recently installed at near North Pole, Tromso, and Toulouse. The K2PS consists of one receiving station and two processing sites. The receiving station has been installed at SvalSat ($N78^{\circ}$, $E15^{\circ}$ ), and the two receiving sites have been installed at KSAT (Kongsberg Satellite Service AS), Tromso, Norway ($N69^{\circ}$ ,$E18^{\circ}$ ) and SISA, Toulouse, France ($N43^{\circ}$ ,$E1^{\circ}$ ). The products ofK2PS system can be classified to two categories: Level 1R product and Level 1G product. The Level 1R product is radiometric corrected product with RPC (Rational Polynomial Coefficients) and the Level 1G product is geometric corrected product with POD (Precise Orbit Data) and PAD (Precise Attitude Data) data based on Level 1R product. To meet a SISA (Spot Image SA)'s requirement, K2PS system has high performance product producing capability. This paper describes overall K2PS systems' production generation flow and the mass production test result of K2PS systems.

  • PDF

Timing Data Optimize of Traffic Intersection C-ITS Message Set for LTE-based V2X in-vehicle Devices (LTE 기반 차량용 V2X 통신단말에 대한 신호 교차로 C-ITS 메시지의 타이밍 데이터 최적화 기법)

  • Park, Su-In;Seo, Woo-Chang;Yang, Eun-Ju;Seo, Dae-Wha
    • Journal of Auto-vehicle Safety Association
    • /
    • v.14 no.1
    • /
    • pp.45-54
    • /
    • 2022
  • Recently, the introduction of Cooperative Intelligent Transport Systems (C-ITS) has been attempted to solve the limitation of only the sensor of the vehicle itself. For example, vehicles traveling at intersections can drive more safely through C-ITS. By using V2X communication of WAVE and LTE, the driver can receive the status and time of traffic lights. However, LTE has a larger transmission delay time than WAVE, so timimg data may not match in real time. In this paper, using the SPaT message, it was confirmed that LTE has a larger C-ITS service transmission delay time than WAVE. Finally, it was confirmed that the timing data of SPaT provided by LTE corrected by the algorithm is similar to SPaT provided by WAVE. It was confirmed that safer intersection driving is possible based on real-time.

Quantitative Comparisons in $^{18}F$-FDG PET Images: PET/MR VS PET/CT ($^{18}F$-FDG PET 영상의 정량적 비교: PET/MR VS PET/CT)

  • Lee, Moo Seok;Im, Young Hyun;Kim, Jae Hwan;Choe, Gyu O
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.68-80
    • /
    • 2012
  • Purpose : More recently, combined PET/MR scanners have been developed in which the MR data can be used for both anatometabolic image formation and attenuation correction of the PET data. For quantitative PET information, correction of tissue photon attenuation is mandatory. The attenuation map is obtained from the CT scan in the PET/CT. In the case of PET/MR, the attenuation map can be calculated from the MR image. The purpose of this study was to assess the quantitative differences between MR-based and CT-based attenuation corrected PET images. Materials and Methods : Using the uniform cylinder phantom of distilled water which has 199.8 MBq of $^{18}F$-FDG put into the phantom, we studied the effect of MR-based and CT-based attenuation corrected PET images, of the PET-CT using time of flight (TOF) and non-TOF iterative reconstruction. The images were acquired from 60 minutes at 15-minute intervals. Region of interests were drawn over 70% from the center of the image, and the Scanners' analysis software tools calculated both maximum and mean SUV. These data were analyzed by one way-anova test and Bland-Altman analysis. MR images are segmented into three classes(not including bone), and each class is assigned to each region based on the expected average attenuation of each region. For clinical diagnostic purpose, PET/MR and PET/CT images were acquired in 23 patients (Ingenuity TF PET/MR, Gemini TF64). PET/CT scans were performed approximately 33.8 minutes after the beginnig of the PET/MR scans. Region of interests were drawn over 9 regions of interest(lung, liver, spleen, bone), and the Scanners' analysis software tools calculated both maximum and mean SUV. The SUVs from 9 regions of interest in MR-based PET images and in CT-based PET images were compared. These data were analyzed by paired t test and Bland-Altman analysis. Results : In phantom study, MR-based attenuation corrected PET images generally showed slightly lower -0.36~-0.15 SUVs than CT-based attenuation corrected PET images (p<0.05). In clinical study, MR-based attenuation corrected PET images generally showed slightly lower SUVs than CT-based attenuation corrected PET images (excepting left middle lung and transverse Lumbar) (p<0.05). And percent differences were -8.01.79% lower for the PET/MR images than for the PET/CT images. (excepting lung) Based on the Bland-Altman method, the agreement between the two methods was considered good. Conclusion : PET/MR confirms generally lower SUVs than PET/CT. But, there were no difference in the clinical interpretations made by the quantitative comparisons with both type of attenuation map.

  • PDF

Duty Cycle-Corrected Analog Synchronous Mirror Delay for High-Speed DRAM (고속 DRAM을 위한 Duty Cycle 보정 기능을 가진 Analog Synchronous Mirror Delay 회로의 설계)

  • Choi Hoon;Kim Joo-Seong;Jang Seong-Jin;Lee Jae-Goo;Jun Young-Hyun;Kong Bai-Sun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.9 s.339
    • /
    • pp.29-34
    • /
    • 2005
  • This paper describes a novel internal clock generator, called duty cycle-corrected analog synchronous mirror delay (DCC-ASMD). The proposed circuit is well suited for dual edge-triggered systems such as double data-rate synchronous DRAM since it can achieve clock synchronization within two clock cycles with accurate duty cycle correction. To evaluate the performance of the proposed circuit, DCC-ASMD was designed using a $0.35\mu$m CMOS process technology. Simulation results show that the proposed circuit generates an internal clock having $50\%$ duty ratio within two clock cycles from the external clock having duty ratio range of $40\;\~\;60$.