• 제목/요약/키워드: corona charging

검색결과 65건 처리시간 0.021초

코로나 대전 특성을 이용한 FRP의 표면 열화메커니즘의 해석 (The Analysis of Surface Degradation Mechanism on PRP(epoxy/glass fiber) by Corona Charging Properties)

  • 이백수;임경범;정의남;박종관;이덕출
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권5호
    • /
    • pp.373-378
    • /
    • 1999
  • In order to analyse the degradation mechanism of polymer materials for outdoor condition, FRP laminate was exposed to high temperature and ultraviolet rays. Then, thedegradation process was evaluated by comparing contact angle, surface potential decay, and polarity effect respectively. Especially, the analysis of surface degradation phenomena by corona charging method showed the exact correlation with the result of chemical properties. Therefore we can confirm that the application of corona charging method on the identification of degradation process is very useful. If this method is usedin degradation studies on the polymer surface, it will be more effective on the surface analysis of polymer insulators. With corona charging method and chemical spectrum analysis, it was possible concretely to define degradation process on the polymer surface exposed at the situation of different environmental conditions.

  • PDF

1,4-Diketo-3,6-Diphenyl-Pyrrolo-[3,4c]-Pyrrole(DPP)계 유기안료의 합성 및 흡수스펙트라 (Synthesis and Absorption Spectra of 1,4-Diketo-3,6-Diphenyl-Pyrrolo-[3,4c]-Pyrrole)

  • 김성훈
    • 한국인쇄학회지
    • /
    • 제14권1호
    • /
    • pp.1-15
    • /
    • 1996
  • In this paper, the preparation of lead zirconium titanate(PZT) thin film by sol-gel processing was descried. Thin film coated with thickness of 4${\mu}{\textrm}{m}$ on the stainless steel substrates using the multiple spin-coating process. The crystalline phases of PZT powder and film were investigated by X-ray diffraction pattern and PZT thin film has perovskite structure over 600 C annealing temperature. Corona charging characteristics of the ferroelectric PZT thin film at 600 C were investigated by electrophotographic measurement. A difference in the charging characteristics between positive and negative corona charging was found. The charge acceptance depended in the polarity of corona and the poling of film. According to the D-E hysteresis measurment, PZT thin film can be poled by corona charging without use of top electrode. The remnant polarization in the PZT thin film is generally in the order of 48$\mu$C/$\textrm{cm}^2$. From this results, the ferroelectric PZT thin film will be possible to apply for the add-on type imaging formation.

  • PDF

폴리염화비닐(PVC)의 코로나 대전현상에 관한 연구 (A study on the Corona Electrification Phenomena for Polyvinyl chloride (PVC))

  • 박구범;황명환;조기선;이덕출;임헌찬
    • 한국안전학회지
    • /
    • 제7권2호
    • /
    • pp.57-62
    • /
    • 1992
  • In this thesis, the electrification phenomenon was studied by measurement of charging current and discharging current in polymers when the carriers generated by corona discharge were supplied to the surface of polymers. Corona charging current of PVC, polar and noncrystalline polymer, was larger than that of nonpolar and amorphous polymers. Corona charging current on the specimen of naked upper surface (CIM) was larger than charging current on the specimen of electrode made. Carrier injection differed from interfacial phase of polymer surFace. The transfer phenomenon vaned with chemical structure of polymer and then the polar effect of PVC was remarkable because of large electron affinity of Cl. In the characteristics of discharging current of PVC, the abnormal current was observed. It was supposed that this phenomena presented the trap of injected carriers in PVC and that static electricity phenomenon was generated by trap.

  • PDF

유한요소법을 이용한 폴리프로필렌 일렉트렛트 셀의 코로나 대전과정 시뮬레이션에 관한 연구 (A Study on the Simulation of the Corona Charging Process of Polypropylene Electret Cell Using Finite Element Method)

  • 이수길;박건호;정일형;장경욱;이준옹
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.169-171
    • /
    • 1993
  • In order to estimate space charging process in the corona charging apparatus which has been used to make polymer electret cell, the electrical properties of 30[${\mu}m$] thick polypropylene film were obtained from TSC measurement after corona charging between copper knife electrode and aluminum cylinder electrode with the voltage of -8, -7, -6, -5 (kV). And, the electrostatic contour and the electric field vector were calculated using Finite Element Method with the electrical properties obtained from TSC spectra analysis. The edge effect around the edge of knife electrode affects electrostatic contour on the surface of specimen and the electric field concentration inside the polymer. As a result the uneven charging state in the electret cell due to the mistake of design was calculated, and the optimal design of corona charging apparatus opprobriate to various specimen was come to be practicable.

  • PDF

코로나 대전된 Teflon-FEP의 충.방전 전류 특성에 관한 연구 (A Study on the Charging and discharging current of corona charged Teflon-FEP film)

  • 정기석;이승우;박광현;이덕출
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1988년도 춘계학술대회 논문집
    • /
    • pp.60-62
    • /
    • 1988
  • In this study, the characteristic of charging current which flows into the polymer by applying the corona discharge carriers on the polymer surface was measured, so as to investigate the phenomenon of charge injection and movement if injected charge on polymer. Also. the characteristics of discharge current which flows by shorting both sides of corona charged polymers were measured. Experimental results are as follows; The amount of charges injected by corona discharge vary according to the state of surface and the type of carriers, and then the charging current varies according to the properties of injected carriers.

  • PDF

Approach to Characterization of a Diode Type Corona Charger for Aerosol Size Measurement

  • Intra Panich;Tippayawong Nakorn
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권5호
    • /
    • pp.196-203
    • /
    • 2005
  • A semi-empirical method to determine the electrostatic characteristics of a diode type corona aerosol charger based on ion current measurement and electrostatic charging theory was presented. Results from mathematical model were in agreement with those from experimental investigation of the charger. Current-voltage characteristics, $N_{i}t$ product and charge distribution against aerosol size were obtained. It was shown that the space charge was significant and must be taken into account at high ion number concentration and low flow rate. Additionally, significant particle loss was evident for particles smaller than 20 nm in diameter where their electrical mobility was high. Increase in charging efficiency may be achieved by introducing surrounding sheath flow and applying AC high voltage. Overall, the approach was found to be useful in characterizing the aerosol charger.

입자하전량에 따른 클린룸 수직벽체로의 입자침착 특성 (Characteristics of Particle Deposition onto Cleanroom Wall Panel for Varying Particle Charging Rates)

  • 김종준;노광철;성상철;백선호;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.725-730
    • /
    • 2008
  • In this study, we found out charged particle's deposition characteristic by experiments of $0.5{\mu}m$, $1.0{\mu}m$, $3.0{\mu}m$ size particle's concentration decay. We carried out the experiments on charged particle deposition onto the vertical cleanroom wall panel and some other fundamental experiments. The particle deposition mechanism is consist of sedimentation, convection, diffusion, thermophoresis, electrostatic and so on. Particle size determines mainly working deposition mechanism. The charged particle is made with corona discharge that are constituted field charging and diffusion charging. In addition, this combinational mechanism is called combined charging. The type of corona discharge determines quantity of particle electrical charge. In conclusion, we assumed that quantity of particle electrical charge accelerations deposition velocity onto the vertical cleanroom wall panel and proved it. And we figured out particle's deposition characteristic through compared between our experiment's results.

  • PDF

소용량 EHD 발전에 관한 실험적 연구 (An Experimental Study on the Small Capacity EHD Power Generation)

  • 전춘생;이재복;임응춘
    • 태양에너지
    • /
    • 제9권2호
    • /
    • pp.58-68
    • /
    • 1989
  • This paper describes an experimental study that was performed to determine the limiting factors on the power output in the closed cycle Electro-Hydro-Dynamic generator of small capacity. A corona discharge for producing unipolar charged particles used as the charging method. The experiment demonstrated that the corona method of charging was an efficient and effective means of producing unipolar charged particles. Four factors having an effect on the power output characteristics of EHD generator are discussed and examined experimentally, using methyl alcohol and kerosene as working fluides; a. The conversion length between attractor and collector. b. The corona current of Emitter. c. The flow velocity of working fluids. d. Load resistance. This results are as follows; 1) There in a critical value in conversion length for its maximum power output. 2) Power output increases almost linearly with corona current and flow velocity. 3) There is the critical value of load resistance producing a maximum power output. 4) Kerosene is known better working fluid than Methyl alcohol in this EHD generator.

  • PDF

합성고분자재료의 대전현상에 관한 기초연구 (A Basic Study on Electrification Phenomena of Synthetic Polymer Material)

  • 이덕출;한상옥
    • 전기의세계
    • /
    • 제28권10호
    • /
    • pp.48-54
    • /
    • 1979
  • The electrification phenomena of polymerized materials is governed by the competitive processes of the charge generation and the charge dissipation. In this paper, The charged particles were supplied on the naked upper surface of the polyethylene film from a point corona discharge with a screen electrode which controls the potential difference across the film. The charging current with the corona charging was found to be larger than that obtained with the electric charging on the MIM structure and the discharge current was found to flow in the same direction as that of the charging current. these results can suggest that the charge injection occurs from the interface between the polethylene surface and the accumulated charge layer, the injected charge are trapped and the space charge is established.

  • PDF

센서재료용 일렉트렛트의 코로나 대전 과정 시뮬레이션 (Simulation of Corona Charging Process in Electret for Sensor Materials)

  • 박건호
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2012년도 제46차 하계학술발표논문집 20권2호
    • /
    • pp.421-422
    • /
    • 2012
  • 본 연구에서는 코로나 대전된 고분자의 열자격전류(Thermally Stimulated Current; 이하 TSC) 데이터를 기반으로 코로나 대전 과정을 유한요소법(Finite Element Method; 이하 FEM)을 이용하여 시뮬레이션하였다. $DC -5{\sim}-8[kV]$의 고전압을 고분자에 인가하여 형성시킨 일렉트렛트를 온도 범위 $-100{\sim}+200[^{\circ}C]$에서 얻은 TSC 데이터의 대전 과정을 조사하기 위하여 FEM으로 시뮬레이션을 수행하여 공간에서 코로나 대전 과정을 추정하였다.

  • PDF