• Title/Summary/Keyword: corneal

Search Result 377, Processing Time 0.03 seconds

A Systematic Review on Drug Safety for Molsidomine, Nicorandil and Trimetazidine (Molsidomine, Nicorandil, Trimetazidine의 안전성 관련 체계적 고찰)

  • Jeong, Kyeong Hye;Lee, Euni
    • Korean Journal of Clinical Pharmacy
    • /
    • v.26 no.2
    • /
    • pp.172-180
    • /
    • 2016
  • Background: Ischemic heart disease is the most common type of heart disease and an important cause of death in Korea. Among marketed anti-anginal medications, molsidomine, nicorandil, and trimetazidine are approved in Korea with unique mechanism of actions. As these drugs are not approved by the US Food and Drug Administration, the access to the up-to-dated and comprehensive safety-related information has been less than optimal from drug information resources used by Korean pharmacists. Methods: A systematic review was conducted using Embase and Korean manuscripts to compile safety updates for these medications. Out of 418 articles from keyword searches, 52 studies were reviewed in full to compare adverse effects (AEs) with the approved package inserts (PI). Results: Molsidomine related adverse effects were mostly mild or moderate, but anxiety, palpitation, epigastric pain, and sexual potency reduction were additional AEs found from the review not listed in PI. Although PI has included ulceration in oral cavity and gastrointestinal tracts including anus by nicorandil, the Korea FDA recently recommended adding corneal, genital, and skin ulcers to the approved PI. Trimetazidine induced Parkinsonism, worsening of the symptoms for patients diagnosed with Parkinson's disease, gastrointestinal burning, and muscle cramps were additionally identified AEs not listed in PI for trimetazidine. Conclusion: Continuous evaluations of the safety profile of these agents are needed to balance the risks and benefits to provide evidence-based safety counseling to the patients. In addition, more focused efforts on spontaneous reporting are warranted by healthcare professionals to safeguard patients against AEs.

Oculocardiac Reflex Caused by Retrobulbar Block in a Dog with Scoliosis (척추측만증이 있는 개에서 안구후방마취 후 발생된 안구심장반사 1례)

  • Park, Young-Woo;Son, Won-Gyun;Kim, Se-Eun;Seo, Kang-Moon;Lee, In-Hyung
    • Journal of Veterinary Clinics
    • /
    • v.26 no.5
    • /
    • pp.476-479
    • /
    • 2009
  • Enucleation of a 9-year-old, spayed female Pekingese's right eye was scheduled because of recurrent eyeball rupture caused by chronic corneal ulcer and descemetocele. Scoliosis of the thoracic vertebra was observed on thoracic radiography. Complete blood count, electrolytes, serum chemistry profiles were within normal ranges except of alkaline phosphatase, which was markedly improved, compared with that of five months ago. Severe respiratory sinus arrhythmia was observed before induction of anesthesia, it disappeared after induction. Retrobulbar block was performed with 0.5% bupivacaine, 2% lidocaine, 0.1% epinephrine combination (4 : 1 : 0.2 ratio of volume) before start of surgery. After retrobulbar block, heart rate decreased from 110 to 76 beats/min and sinus arrhythmia recurred. It was considered as oculocardiac reflex caused by increase of intraorbital pressure from retrobulbar block, atropine (0.025 mg/kg, IV) was administered and intermittent positive pressure ventilation was started. Three minutes after atropine administration, abnormal waveform of the electrocardiograph was appeared, it suspected as ventricular or supraventricular tachycardia, so lidocaine (2 mg/kg, IV) was administered. Then, heart rate was maintained around 130 beats/min, and the surgery was finished without the other problems. Although, retrobulbar block is performed to provide analgesia and to prevent oculocardiac reflex in ophthalmic surgery, occasionally it could induce oculocardiac reflex by infiltrated volume.

The Retrospective Study of 463 Patients who had Funduscopy Examination at Korean Medicine Ophthalmology (한방 안과에 내원하여 안저 검사를 시행한 환자 463명에 대한 후향적 연구 보고)

  • Lee, Ma-Eum;Jeong, Mi-Rae;Kim, Chul-Yun;Kwon, Kang;Seo, Hyung-Sik
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.33 no.2
    • /
    • pp.1-11
    • /
    • 2020
  • Objectives : The purpose of this study was to analyze and report status of Korean Medicine Ophthalmology patients who did funduscopy examination. Through this, we hope that the development of our diagnosis and treatment. Methods : From June 1, 2010 to May 31, 2019, Based on the electronic medical records of patients who had funduscopy examination at Korean Medicine Ophthalmology, Busan University Korean Medicine Hospital, the gender, age, visiting motives and paths, diagnosis, examination number of years, other eye examinations and treatments method were summarized and analyzed. Results : 463 patients were able to check the electronic medical records. They were 283 females and 180 males. The mean age of the patients was 51.5 years and elderly patients who 50s and 60s were 49.3% of whole patients. The most common motives for Korean Medicine Ophthalmology visitation was 'combination treatment with other department in Korean Medicine Hospital'. Outer eye diseases were 283 cases, inner eye diseases were 198 cases. Dry eye syndrome, asthenopia, visual discomfort, conjunctivitis, and eye discomfort were most common in the outer eye diseases. Cataracts, Vitreous floater, Macular Degeneration, Glaucoma and Ocular Pain were most common in the inner eye disease. The most common parts of outer eye diseases were Conjunctival, lacrimal gland, paralytic, corneal, eyelid and front uveal, scleral disease and then in inner eye diseases parts, Retinal, lens, vitreous, glaucoma, optic nerve, behind uveal, choroid disease were most common. The number of funduscopy examination was ups and downs. Herbal medicine was the most common used. Conclusions : The funduscopy examination is essential for diagnosis and treatment of eye disease. We hope that the use of fundus examination and other ophthalmologic examination will be expanded soon in Korean Medicine Ophthalmology.

Effects of Base Curve on Fitting with the current Soft Contact Lenses (베이스 커브에 의한 콘택트렌즈 피팅 효과)

  • Choe, Oh Mok;Gang, Myoung Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.65-72
    • /
    • 2000
  • The study investigated the effects of base curve radius art the fit of thin, mid-water contact lenses. It was found that central corneal curvature(as measured with the keratometer) was not predictive of the best fitting base curve. Proper lens fit may be the single most important factor that ultimately determines the success of contact lens wear. Comfort, vision, and physiological response are all dependent on the fit of the lens. The percent of optimal fits was highest with the 8.4 mm base curve lens for all three ranges of keratometry values. When fit with the 8.4 mm lens. For most eyes, fitting a flatter lens led to greater decentration, decreased comfort, and no increase in lens movement. The 8.4 mm lens was found to provide on "optimal" fit in over 60% of eyes tested and a fit of "good" or "better" in nearly 90% of eyes tested. Comparisons of different manufactures' lens found that similiar lenses do not always fit in the same way due to subtle design and production differences. Therefore, different products may require different base curve radii to fit the same patient. This is even true when water content, center thickness, and diameter are approximately the same. A praditioner fitting a new patient in this lenses should begin with the 8.4 mm base curve radius.

  • PDF

Pulsed Radiofrequency Treatment of the Supraorbital and Supratrochlear Nerve in a Case of Trigeminal Neuralgia -A case report- (삼차신경통 환자에서 안와상 신경과 활차상 신경에 시행한 박동성 고주파술에 의한 치료경험 -증례보고-)

  • Seo, Kwi Chu;Shin, Heung Dong;Kim, Jong Hae;Song, Seok Young;Rho, Woon Seok;Chung, Jin Yong
    • The Korean Journal of Pain
    • /
    • v.22 no.2
    • /
    • pp.167-170
    • /
    • 2009
  • Pharmacological management is the first choice for treatment of the trigeminal neuralgia patients; however, if this mode of treatment fails a minimally invasive procedure should be performed. One of the most commonly used procedures is conventional radiofrequency lesioning of the Gasserian ganglion. Despite its popularity and success rate, this technique has disadvantages such as diminished corneal reflex, masseter weakness, numbness and anesthesia dolorosa. As a result, many studies have been conducted in an attempt to find a better method of treating trigeminal neuralgia. We report here a case of a trigeminal neuralgia patient that was treated with pulsed radiofrequency lesioning of the supraorbital and supratrochlear nerve due to pain in the frontal head that was refractory to the pharmacological treatments. Following the procedure, the Visual Analogue Scale score for pain decreased to 1-2/10 and the pain relief persisted for 7 months. These results indicate that pulsed radiofrequency treatment of the peripheral nerve may be useful for trigeminal neuralgia patients that do not respond to pharmacological treatments.

Experience with Conventional Radiofrequency Thermorhizotomy in Patients with Failed Medical Management for Trigeminal Neuralgia

  • Singh, Sarita;Verma, Reetu;Kumar, Manoj;Rastogi, Virendra;Bogra, Jaishree
    • The Korean Journal of Pain
    • /
    • v.27 no.3
    • /
    • pp.260-265
    • /
    • 2014
  • Background: To evaluate the results of conventional radiofrequency thermorhizotomy (CRT) for trigeminal neuralgia (TN) in patients with failed medical management. Methods: Patients with Trigeminal neuralgia who were referred to us for 'limited intervention' during the time frame July-2011 to Jan-2013 were enrolled for this study. CRT was administered by the Sweet technique. Pain relief was evaluated by the principle investigator. Results: Eighteen patients were enrolled and completed a mean follow-up of 18.0 months. Pain relief was observed in 14 of 18 (77.8%) patients on the post-operative day, 14 of 18 (77.8%) at 1-month follow-up, 14 of 17 (82.4%) at 3-months follow-up, 12 of 15 (80%) at 6-months follow-up, 7 of 11 (63.6%) at 1-year follow-up and 2 of 6 (33.3%) 1.5 years of follow-up. Four patients required a repeat cycle of CRT; two at six months of follow-up and two at one year of follow-up. One patient was transferred for surgical intervention at six months of follow-up. Side-effects included facial hypoesthesia (n = 6); nausea/vomiting (n = 2), diminished corneal reflex (n = 13) and difficulty in chewing (n = 11). Severity of adverse effects gradually diminished and none of the patients who are beyond 6 months of follow-up have any functional limitation. Conclusions: CRT is an effective method of pain relief for patients with Trigeminal neuralgia. Successful outcome (excellent or good) can be expected in 66.7% of patients after first cycle of CRF. The incidence and severity of adverse effects is less and the procedure is better tolerated by the patients.

Image Analysis Algorithm for the Corneal Endothelium

  • Kim Young-Yoon;Kim Beop-Min;Park Hwa-Joon;Im Kang-Bin;Lee Jin-Su;Kim Dong-Youn
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.3
    • /
    • pp.125-130
    • /
    • 2006
  • The number of the living endothelial cells and the shape of those are very import clinical parameters for the evaluation of the quality of cornea. In this paper, we developed the automated endothelial cell counting and shape analysis algorithm for a confocal microscope. Since, the endothelial images from the confocal microscope has a non-uniform illumination and low contrast between cell boundaries and cell bodies, it is very difficult to segment the cells from the endothelial images. To cope with these difficulties, we proposed the new two stage image processing algorithm. At first stage algorithm, we used a high-pass filter and histogram equalization to compensate the non-uniform brightness pattern and a morphological filter and a watershed method are applied to detect the boundary of cells. From this stage, we could count the number of cells in an endothelial image. At second stage algorithm, we used a Voronoi diagram method to classify the shape of cells. This cell shape analysis and the percent of hexagonal cells are very sensitive in detecting the early endothelium damage. To evaluate the performance of the proposed system, we p개cessed seven endothelial images obtained using a confocal microscope. The proposed system correctly counted 95.5% cells and classified 92.0% of hexagonal cell shapes. This result is better than any others in this research area.

A Mechanical Model of Excimer Laser Surgery (엑시머 레이저 수술의 역학적 모델)

  • Shin, Jung-Woog;Kim, Jong-Hyun
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.57-60
    • /
    • 1993
  • A finite element-based computer simulation of excimer laser susery was conducted to study some factors on the surgery. In particular, the radius of curvature at the apex of the cornea was examined under various surgical conditions. Corneal tissue was assumed to be a nearly incompressible, linear elastic, homogeneous, isotropic material under very small deformation. The geometry of the human cornea was taken from the experimental data[1]. The simulation utilized ANSYS(Swanson Analysis System Inc.Rev.4.4A). In this study, the major factors which affect the outcomes of the excimer laser surgery were investigated. First, two patterns of surgery with various surgery thickness(40-70micrometers) were examind. The pattern#1 describes the meridian from the apex to the edge of the surgery area to be straight. And the corresponding meridian of the pattern 2 can be expressed as a quardratic function. The results show that the pattern #2 is more realistic and effective. Then, the effects of other factors were investigated based on the pattern #2. Other factors are:various diameters of the surgical area (3-8 milimeters), Young's modules(3.5-4.5MPa), and depth of surgery at the apex(40-70micrometers). Compared with the computer simulation of the radial keratotomy surgery[2], the excimer laser surgery was proven to be more effective in treating myopia patients. In conculusion, the results of the simulation are qualitative agreement with clinical experience[3] indicating the potential of the finite element model of the surgery as a guideline to the surgeon before actual surgery.

  • PDF

Backbone NMR assignments of the FAS1-3/FAS1-4 domains of transforming growth factor-beta-induced protein

  • Kang, Dong-Hoon;Yi, Jong-Jae;Sim, Dae-Won;Park, Jung-Wook;Lee, Sung-Hee;Kim, Eun-Hee;Jeon, Young-Ho;Son, Woo Sung;Won, Hyung-Sik;Kim, Ji-Hun
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • An extracellular matrix protein, transforming growth factor-beta-induced protein (TGFBIp/βig-h3), which is induced by transforming growth factor-β in the human cornea, skin, and matrix of many connective tissues, is associated with the adhesion, migration, proliferation, and differentiation of various cells. TGFBIp contains four homologous repeat domains, known as FAS1 domains, where certain mutations have been considered to cause corneal dystrophies. In this study, backbone NMR assignments of FAS1-3/FAS1-4 tandem domain were obtained and compared with those previously known for the isolated FAS1-4 domain. The results corroborate in solution the inter-domain interaction between FAS1-3 and FAS1-4 in TGFBIp.

Glint Reconstruction Algorithm Using Homography in Gaze Tracking System (시선 추적 시스템에서의 호모그래피를 이용한 글린트 복원 알고리즘)

  • Ko, Eun-Ji;Kim, Myoung-Jun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2417-2426
    • /
    • 2014
  • Remote gaze tracking system calculates the gaze from captured images that reflect infra-red LEDs in cornea. Glint is the point that reflect infra-red LEDs to cornea. Recently, remote gaze tracking system uses a number of IR-LEDs to make the system less prone to head movement and eliminate calibration procedure. However, in some cases, some of glints are unable to spot. In this case, it is impossible to calculate gaze. This study examines patterns of glints that are difficult to detect in remote gaze tracking system. Afterward, we propose an algorithm to reconstruct positions of missing glints that are difficult to detect using other detected glints. Based on this algorithm, we increased the number of valid image frames in gaze tracking experiments, and reduce errors of gaze tracking results by correcting glint's distortion in the reconstruction phase.