• Title/Summary/Keyword: cornea thickness

Search Result 42, Processing Time 0.024 seconds

Fabrication of Ex vivo Cornea Model for a Drug Toxicity Evaluation (약물 독성 평가용 생체외 각막 모델 제작 연구)

  • Kim, Seon-Hwa;Park, Sang-Hyug
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.143-150
    • /
    • 2019
  • To evaluate the toxicity of ophthalmic drug, the Draize test and Bovine Corneal Opacity and Permeability (BCOP) test commonly used. In Draize test, experimental animals were under stress and pain due to long-term exposure of drug. In addition, regarding physiological functions, animal model is not perfectly reflected a human eye condition. Although some models such as $EpiOcular^{TM}$, HCE model, LabCyte Cornea-Model, and MCTT $HCE^{TM}$ were already presented advanced cornea ex-vivo model to replace animal test. In this sense, cornea tissue structure mimicked ex-vivo toxicity model was fabricated in this study. The corneal epithelial cells (CECs) and keratocytes (CKs) isolated from rabbit eyeball were seeded on non-patterned silk film (n-pSF) and patterned silk film (pSF) at $32,500cells/cm^2$ and $6,500cells/cm^2$. Sequentially, n-pSF and pSF were stacked to mimic a multi-layered stroma structure. The thickness of films was about $15.63{\mu}m$ and the distance of patterns was about $3{\mu}m$. H&E stain was performed to confirm the cell proliferation on silk film. F-actin of CKs was also stained with Phalloidin to observe the cytoskeletal alignment along with patterns of the pSF. In the results, CECs and CKs were shown the good cell attachment on the n-pSF and pSFs. Proliferated cells expressed the specific phenotype of cornea epithelium and stroma. In conclusion, we successfully established the ex-vivo cornea toxicity model to replace the eye irritation tests. In further study, we will set up the human ex-vivo cornea toxicity model and then will evaluate the drug screening efficacy.

Mathematical Expression of the Toric Cornea using Corneal Topography Measurements (각막지형도(topography) 각막곡률로부터 토릭 각막형상의 수식화)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.439-444
    • /
    • 2011
  • Purpose: To represent the shape of toric corea in the elliptical function for the determination of curvature distribution and lacrimal thickness between cornea and contact lens when the lens is fitted. Methods: Topography measurements of corneal curvature and curvature equation derived from the assumed elliptical function were evaluated using the Excel program which included the necessary equation derived. Results: Mathematical expressions for the cornea whose ribbon shaped-topography image, in which the center does not coincide with the corneal apex, can be determined. Conclusions: For the application where the higher accuracy on the cornea is not required, such as higher order aberration, the cornea cal be expressed in the simple elliptical function.

Effect of combined sodium hyaluronate and carboxymethyl cellulose on ocular surface in rat dry eye model

  • Moon, Jong-Gab;Ku, Sae-Kwang;Kwon, Young-Sam
    • Korean Journal of Veterinary Research
    • /
    • v.56 no.3
    • /
    • pp.155-160
    • /
    • 2016
  • This study was conducted to evaluate three different mixed formulations of sodium hyaluronate (SH) and carboxymethyl cellulose (CMC) using a low-humidity air flow-induced rat dry eye model and determine the most suitable mixture. The total thickness of the cornea, corneal epithelial thickness, corneal stroma thickness, damaged corneal epithelium percentage region, thickness of the bulbar conjunctiva epithelium, number of goblet cells, goblet cell occupation percentage region, and damaged bulbar conjunctiva epithelium percentage region were measured by histomorphological evaluation. After 5 h exposure to drying airflow, the thickness of the cornea and conjunctiva was decreased with desquamation of the corneal and conjunctiva epithelium. However, these dry eye symptoms were markedly inhibited by treatment with the reference and test formulations. More favorable effects on decreased thickness were detected in response to the CMC than the SH. However, SH had a greater protective effect against corneal and conjunctiva epithelial damage. The application of a mixture of 0.1% SH and 0.2% CMC showed more favorable effects on the corneal and conjunctival damage and the stabilization of the ocular surface than SH or CMC alone.

"Letter-Box" Conjunctival Flap in a Dog with Severe Corneal Edema after Phacoemulsification

  • Sunhyo Kim;Dohyoung Kwon;Kangmoon Seo;Seonmi Kang
    • Journal of Veterinary Clinics
    • /
    • v.40 no.2
    • /
    • pp.152-157
    • /
    • 2023
  • A two-year-old, spayed female, Bichon Frise, was referred for severe corneal edema and corneal ulcer in the left eye (OS). The cornea had gradually swelled over one week after phacoemulsification performed a month prior, and that was refractory to 5% sodium chloride eye drop instillation or temporary partial tarsorrhaphy. A complete ophthalmic examination was performed. Severe corneal edema with intrastromal bullae and moderate anterior chamber flare was found on slit-lamp biomicroscopy in the OS, which obstructed the fundus examination. Corneal thickness was measured using high-resolution ultrasound biomicroscopy. The thickness of the OS cornea was 2.74 mm. The "letter-box" conjunctival flap was planned. Dorsal and ventral superficial keratectomy followed by a hood conjunctival flap was performed. Topical and systemic antibiotics and 5% sodium chloride eye drops were prescribed. Decreased corneal thickness was observed at one week, two weeks, and two months postoperatively (1.53 mm, 1.32 mm, and 0.92 mm, respectively). There were no postoperative complications, such as ocular discomfort or recurrent corneal ulcers. The "letter-box" conjunctival flap, a type of superficial keratectomy and conjunctival advancement hood flap, effectively relieved the severe irreversible corneal edema. This could be a simple but effective surgical intervention for patients with endothelial cell damage especially after phacoemulsification.

Survey of Corneal Thickness, Endothelial Cell and Intraocular Pressure in New Zealand White Rabbits (뉴질랜드 흰 토끼의 각막 두께, 내피세포 및 안압에 관한 조사)

  • Chang, Hwa-Seok;Lee, Dae-Yeoup;Kang, Eun-Hee;Lee, Jae-Hoon;Cho, Yang-Kyeung;Kim, Man-Soo;Kim, Hwi-Yool
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.411-414
    • /
    • 2010
  • Rabbit's cornea is the most common thing that used for researches in ophthalmology, so many experimentations have done. The purpose of this study was to survey the corneal pachymetry, tonometry and specular microscopy in New Zealand white rabbits. Three months old male rabbits ($2.9{\pm}0.2\;kg$) were examined with contact the specular microscope to evaluate the endothelial cell density, coefficiency of variation and the percentage of hexagonal cells in the central cornea. For the pachymetry, ultrasonic pachymeter was used for central cornea in each twenty rabbits, and tonometry was performed forty rabbit's eyes to evaluate the intraocular pressure. Corneal endothelial cell density in New Zealand white rabbit was $3304{\pm}354\;cell/mm^2$. Coefficiency of variation was $45.8{\pm}2$ and the percentage of hexagonal cells in the central cornea was $44.4{\pm}11%$. The pachymetry of cornea was $346.1{\pm}21\;{\mu}m$ and tonometry of eye was $14.3{\pm}2\;mmHg$. It is considered that normal New Zealand white rabbit's pachymetry, specular microscopy and tonometry were useful basic data of rabbit's cornea for research and clinic in veterinary ophthalmology.

A Frequency Domain Analysis of Corneal Deformation by Air Puff (Air puff에 의한 각막 변형의 주파수 영역 분석)

  • Hwang, Ho-Sik;Lee, Byeong Ha;Lee, Chang Su
    • Journal of IKEEE
    • /
    • v.18 no.2
    • /
    • pp.240-247
    • /
    • 2014
  • Intraocular pressure is measured after a cornea air puff by observing biomechanical properties such as thickness or displacement of the cornea. In this paper, we deal with a frequency domain analysis of corneal deformation in the air puff tonometry that is used to diagnose glaucoma or lasik. We distinguish the patient from the normal by measuring the oscillation frequency in the neighborhood of the central cornea section. A binary image was obtained from the video images, and cornea vertical oscillation profile was extracted from the difference between the vertical displacement data and the curve fitting. In terms of Fourier transform, a vibration frequency of 479.2Hz for the patient was obtained as well as more higher 702.8Hz for the normal due to stiffness. Hilbert-Huang transform's empirical mode decomposition generally describes local, nonlinear, and nonstationary data. After the data were decomposed into intrinsic mode functions, a spectrum and power were analysed. Finally, we confirm that the patient has 6 times more higher power ratio for the specific intrinsic mode function between the patient and the normal.

Analysis on the Depressing Force to the Cornea by Fitted Spherical Contact Lens (구면 콘택트렌즈의 피팅에 따른 각막 부착력 해석)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.97-106
    • /
    • 2011
  • Purpose: This review article was written to theoretically compare the depressing force (pressure, adhesion) to the cornea between when the spherical lenses were being tightly and flat fitted. Methods: Mathematical equations and their numerical solution programs (model) were formulated to calculate the depressing (adhesion) force to the cornea by both the tightly and flat fitted contact lenses. Based on this proposed model the effects of parameters characterizing a contact lens such as BCs, diameters, edge shape and corneal shape (ratio of long and short corneal axis, p) on the depressing force to the cornea were predicted/analyzed in both tightly and flat fitting regimes. Results: Corneal adhesion increased as the corneal p-value increased. Adhesion increase caused by the increased p-value was much larger in flat fitted case than in tight fitted one. Corneal adhesion reduced abruptly as the BC increased in flat fitting regimes while the adhesion rise was insignificant in tight fitting ones. Reduction in corneal adhesion due to lens-size increase was predicted to be insignificant in both tight and flat fitting regimes. Both the lens edge shape (edge angle) and thickness were relevant only in tight fitting regime. Corneal adhesion increased as the increased with tight-fitted lenses. As the thickness of tight fitted lenses increased, corneal adhesion inversely decreased. Conclusions: The two most significantly affecting the depressing force to cornea were found to be the degree of corneal bending toward the periphery and the BCs of lenses.

Effect of Intense Regulated Pulse Light on Thickness of Tear Film Lipid Layer and Dry Eye Syndrome (조절펄스광선조사가 눈물막 지질층 두께 및 안구건조증에 미치는 효과)

  • Gil, Tae Young;Bae, Gi Hyun;Kwag, Joo Young;Hyun, Joo;Choi, Jin Seok;Pak, Kyu Hong;Chung, Sung Kun
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1103-1107
    • /
    • 2018
  • Purpose: To evaluate the clinical effect of intense regulated pulse light (IRPL) and changes in tear film thickness in dry eye patients. Methods: A retrospective study was conducted on 25 patients with Meibomian gland dysfunction who had subjective dry eye discomfort and whose tear film break-up time (TBUT) was < 10 seconds. All patients were treated with IRPL three times on days 1, 15, and 45. TBUT, Schirmer 1 test results, cornea staining score with fluorescein, ocular surface disease index (OSDI), and lipid layer thickness were measured and compared before and after the procedure. Results: TBUT was significantly increased from $3.7{\pm}1.2s$ to $4.4{\pm}2.1s$ after IRPL (p = 0.03). Schirmer 1 test and cornea staining scores changed significantly (p < 0.01 and p = 0.01, respectively). OSDI also showed a statistically significant improvement from $39.5{\pm}17.5points$ to $30.4{\pm}18.7points$ (p = 0.01). However, no significant difference in lipid layer thickness was observed (p = 0.49). Conclusions: IRPL is an effective treatment modality to improve TBUT, Schirmer 1 test scores, cornea staining scores, and subjective dry eye symptoms.

Model on the Capillary Action-Induced Dynamics of Contact Lens (모세관 작용에 의한 콘택트 렌즈의 운동 모델)

  • Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.85-97
    • /
    • 2001
  • A mathematical model was proposed to analyze the damped motion of contact lens which is initially displaced from the equilibrium position. The model incorporates the differential equations and their numerical solution program, based on the formulations of restoring force arising from the capillary action in the tear-film layer between the lens and cornea. The model predicts the capillary action induced surface tension, time dependence of displacement of lens when it is released from the equilibrium position. It seems that the motion of lens is similar to the typical over-damped oscillation caused by the large viscous friction in the liquid layer between the cornea and lens. The effect of variables such as base curves, lens diameters and thickness of tear film layer were illustrated by the computer simulation of the derived program. The time required for the lens to return to the original position increases as the liquid layer thickness increases and it decreases as the diameter of lens increases. With the certain value of base curve the time interval is found to be minimum. The free vibrations of lenses were also simulated varying the parameters such as base curve, diameter, layer thickness. The resonant frequencies are inversely proportional to the liquid layer thickness and it increases as the lens diameter increases. The resonant frequency of lens has a maximum when the diameter is of certain value. If the external impulse or force of the same frequency as the natural frequency of contact lens acted on the cornea in vivo it may cause an excessive movement and thus it might cause the distortion 10 the lens or be pulled off the eye.

  • PDF

Study of the cornea characteristics using Oculus Pentacam (Oculus Pentacam을 사용한 각막 특성 분석)

  • Lee, Jeung-Young;Park, Eun-Kyoo
    • Journal of the Korea society of information convergence
    • /
    • v.6 no.1
    • /
    • pp.37-41
    • /
    • 2013
  • In this study, by using the Oculus Pentacam, we analyzed the relationship of corneal front astigmatism corneal and the radius of curvature of the rear face of the 20's to 40's. The vertical radius of curvature were man 7.94mm (${\pm}0.22$), women 7.87mm (${\pm}0.21$), the horizontal radius of the anterior corneal appeared man 7.69mm (${\pm}0.27$), women 7.63mm(${\pm}0.23$). And rear vertical radius of curvature were man 6.52mm(${\pm}0.23$), woman 6.55mm (${\pm}0.22$), the horizontal radius of the anterior corneal appeared man 6.06mm (${\pm}0.24$), woman 6.08mm(${\pm}0.24$). The results of correlation analysis between the radius of corneal posterior surface and the anterior corneal surface, it was found out that there is a significant correlation. In this study, similar results were obtained anterior surface of the cornea, the radius of curvature of the rear surface, the refractive power, and astigmatism, as other papers that have been reported. But in this paper, the cornea thickness was thicker than other previously reported paper.

  • PDF