• Title/Summary/Keyword: core injection

Search Result 345, Processing Time 0.026 seconds

Vortex Cavitation Inception Delay by Attaching a Twisted Thread (Twisted thread에 의한 보텍스 캐비테이션 초생지연)

  • Park, Sang-Il;Lee, Seung-Jae;You, Guek-Sang;Suh, Jung-Chun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.3
    • /
    • pp.259-264
    • /
    • 2014
  • Tip vortex cavitation (TVC) is important for naval ships and research vessels that require raising the cavitation inception speed to maximum possible values. The concepts for alleviating the tip vortex are summarized by Platzer and Souders (1979), who carried out a thorough literature survey. Active control of TVC involves the injection of a polymer or water from the blade tip. The main effect of such mass injection (both water and polymer solutions) into the vortex core is an increase in the core radius, consequently delaying TVC inception. However, the location of the injection port needs to be selected with great care in order to ensure that the mass injection is effective in delaying TVC inception. In the present study, we propose a semi-active control scheme that is achieved by attaching a thread at the propeller tip. The main idea of a semi-active control is that because of its flexibility, the attached thread can be sucked into the low-pressure region closer to the vortex core center. An experimental study using a scale model was carried out in the cavitation tunnel at the Seoul National University. It was found that a flexible thread can effectively suppress the occurrence of TVC under the design condition for a model propeller.

A study on light weighted injection molding technology and warpage reduction for lightweight automotive head lamp parts (자동차 헤드램프 부품의 경량화 사출 성형기술 및 변형 저감에 관한 연구)

  • Jeong, Eui-Chul;Son, Jung-Eon;Min, Sung-Ki;Kim, Jong-Heon;Lee, Sung-Hee
    • Design & Manufacturing
    • /
    • v.13 no.2
    • /
    • pp.1-5
    • /
    • 2019
  • In this study, micro cellular injection molding of automobile head lamp housing with uneven thickness structure was performed to obtain improvement on deformation and light-weight of the part. The thickness of the presented model was uniformly modified to control the deformation of the molded part. In order to maximize the lightweight ratio, the model having an average thickness of 2.0 mm were thinly molded to an average thickness of 1.6 mm. GFM(Gas Free Molding) and CBM(Core Back Molding) technology were applied to improve the problems of the conventional foam molding method. Equal Heat & Cool system was also applied by 3D cooling core and individual flow control system. Warpage of the molded parts with even cooling was minimized. To improve the mechanical properties of foamed products, complex resin containing nano-filler was used and variation of mechanical properties was evaluated. It was shown that the weight reduction ratio of products with light-weighted injection molding was 8.9 % and the deformation of the products was improved from the maximum of 3.6 mm to 2.0 mm by applying Equal Heat & Cool mold cooling system. Also the mechanical strength reduction of foamed product was less than 12% at maximum.

Effects on the process factors of blow molding affects to the PET bottle (블로우 성형공정변수가 PET 용기에 미치는 영향에 관한 연구)

  • Kim, Jong-Dug;Go, Young-Bae;Kim, Ok-Rae;Park, Hyung-Pil;Kim, Hong-Ryul;Kwon, Chang-Oh
    • Design & Manufacturing
    • /
    • v.2 no.6
    • /
    • pp.7-10
    • /
    • 2008
  • Injection-stretch blowing system for preform has been developed in this study. The preforms for injection blow molding and injection stretch blow molding are being manufactured by injection molding. However it contains gate mark that affects the bottom crack in the PET bottle. The compression molded preform does not contain gate mark, thus the appearance quality of bottle has been increased and the residual stress near gate(bottom of the bottle) has been reduced. The thickness distributions, haze, and transmittance are well accepted for the preform. Also, flow characteristics of the resin between a core and cavity could be analyzed through computer simulation.

  • PDF

Fabrication of Cores for the Injection Mould with a High Cooling Rate and Injection Molding Using the Fabricated Core (고속 냉각 특성을 가진 사출성형 금형 코어 제작 및 사출 성형)

  • Ahn, D.G,
    • Transactions of Materials Processing
    • /
    • v.16 no.7
    • /
    • pp.549-554
    • /
    • 2007
  • The objective of this paper is to investigate into the fabrication technology of cores for the injection mould with three-dimensional conformal cooling channels to reduce the cooling time. The location of the conformal cooling channels has been determined through the injection molding analysis. The mould has been manufactured from a hybrid rapid tooling technology, which is combined a direct metal rapid tooling with a machining process. Several injection molding experiments have been performed to examine the productivity and the validity of the designed mould. From the results of the experiments, it has been shown that the proposed mould can mold a final product within a cooling time of 3 seconds and a cycle time of 21 seconds, respectively.

Evaluation of Injection Property of Crack Repair Method by Right Angle Drill Method with Packer (직각천공방식으로 패커를 설치한 균열보수공법의 보수재 주입특성)

  • 고진수;이성복;서치호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.581-586
    • /
    • 2003
  • The objective of this study is to evaluate the injection performance of crack repair method in concrete structure. To improve the quality of the concrete structure caulking material was injected into the crack of building that were planned to be demolished and injection properties of various repair method were compared and assessed according to type of crack. Results from the test showed that when cracks and injection port were integrated and the injection port wasn't blocked repair material was able to be injected even below around 40㎏/㎠ pressure. Moreover, effective pressure each type of packer showed wide range varying from 200-400㎏/㎠. As for drill method for injection port, core drill method has shown to be more effective compared to the air pump method

  • PDF

A Study on the Molding Technology for the Preform of Blow Molding Through Compression Molding (압축성형을 통한 블로우 성형품용 프리폼 성형기술 연구)

  • Choi, S.H.;Min, H.K.;Lyu, M.Y.
    • Transactions of Materials Processing
    • /
    • v.16 no.1 s.91
    • /
    • pp.3-8
    • /
    • 2007
  • Novel compression molding system for preform has been developed in this study. The preforms for injection blow molding and injection stretch blow molding are being manufactured by injection molding. However it contains gate mark that affects the bottom crack in the PET bottle. The compression molded preform does not contain gate mark, thus the appearance quality of bottle has been increased and the residual stress near gate(bottom of the bottle) has been reduced. The thickness distributions, haze, and transmittance are well accepted for the preform. Also, flow characteristics of the resin between a core and cavity could be analyzed through computer simulation.

The Effects of Convergence-Based Reeducation on Core Basic Nursing Skills on Nursing Students' Competence and Confidence (융복합기반 핵심기본간호술 재교육이 간호학생의 수행능력 및 자신감에 미치는 효과)

  • Jung, Myung-Sook;Kwon, Young-Sook
    • Journal of Digital Convergence
    • /
    • v.13 no.4
    • /
    • pp.295-302
    • /
    • 2015
  • The purpose of this study was to evaluate the effects of convergence-based reeducation of core basic nursing skills (subcutaneous injection, indwelling catheterization) on competence, knowledge, attitude and confidence for nursing students. Subjects were 34 nursing students and 3rd grade. Experimental treatment and data collection was conducted from December 14 to 29, 2013. Skills for subcutaneous injection including simple blood glucose test and indwelling catheterization were evaluated before and after intervention. Knowledge, attitude and confidence were measured using structured questionnaires. Data were analyzed by the frequency, descriptive statistics and paired t-test using SPSS version 21. As a result, after reeducation, significant improvement was found in competence (p<.001), knowledge (p<.001) and confidence (p<.001) in subcutaneous injection and indwelling catheterization. Convergence-Based reeducation program was found effective to enhance the competence of core basic nursing skills before graduating nursing students. Therefore, it is necessary to continue to develop program and to evaluate the effects with further research.

ADVANCED DVI+

  • Kwon, Tae-Soon;Lee, S.T.;Euh, D.J.;Chu, I.C.;Youn, Y.J.
    • Nuclear Engineering and Technology
    • /
    • v.44 no.7
    • /
    • pp.727-734
    • /
    • 2012
  • A new advanced safety feature of DVI+ (Direct Vessel Injection Plus) for the APR+ (Advanced Power Reactor Plus), to mitigate the ECC (Emergency Core Cooling) bypass fraction and to prevent switching an ECC outlet to a break flow inlet during a DVI line break, is presented for an advanced DVI system. In the current DVI system, the ECC water injected into the downcomer is easily shifted to the broken cold leg by a high steam cross flow which comes from the intact cold legs during the late reflood phase of a LBLOCA (Large Break Loss Of Coolant Accident)For the new DVI+ system, an ECBD (Emergency Core Barrel Duct) is installed on the outside of a core barrel cylinder. The ECBD has a gap (From the core barrel wall to the ECBD inner wall to the radial direction) of 3/25~7/25 of the downcomer annulus gap. The DVI nozzle and the ECBD are only connected by the ECC water jet, which is called a hydrodynamic water bridge, during the ECC injection period. Otherwise these two components are disconnected from each other without any pipes inside the downcomer. The ECBD is an ECC downward isolation flow sub-channel which protects the ECC water from the high speed steam crossflow in the downcomer annulus during a LOCA event. The injected ECC water flows downward into the lower downcomer through the ECBD without a strong entrainment to a steam cross flow. The outer downcomer annulus of the ECBD is the major steam flow zone coming from the intact cold leg during a LBLOCA. During a DVI line break, the separated DVI nozzle and ECBD have the effect of preventing the level of the cooling water from being lowered in the downcomer due to an inlet-outlet reverse phenomenon at the lowest position of the outlet of the ECBD.

Performance analysis of automatic depressurization system in advanced PWR during a typical SBLOCA transient using MIDAC

  • Sun, Hongping;Zhang, Yapei;Tian, Wenxi;Qiu, Suizheng;Su, Guanghui
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.937-946
    • /
    • 2020
  • The aim in the present work is to simulate accident scenarios of AP1000 during the small-break loss-of-coolant accident (SBLOCA) and investigate the performance and behavior of automatic depressurization system (ADS) during accidents by using MIDAC (The Module In-vessel Degradation severe accident Analysis Code). Four types of accidents with different hypothetical conditions were analyzed in this study. The impact on the thermal-hydraulic of the reactor coolant system (RCS), the passive core cooling system and core degradation was researched by comparing these types. The results show that the RCS depressurization becomes faster, the core makeup tanks (CMT) and accumulators (ACC) are activated earlier and the effect of gravity water injection is more obvious along with more ADS valves open. The open of the only ADS1-3 can't stop the core degradation on the basis of the first type of the accident. The open of ADS1-3 has a great impact on the injection time of ACC and CMT. The core can remain intact for a long time and the core degradation can be prevent by the open of ADS-4. The all results are significant and meaningful to understand the performance and behavior of the ADS during the typical SBLOCA.

Groutability enhancement by oscillatory grout injection: Verification by field tests

  • Kim, Byung-Kyu;Lee, In-Mo;Kim, Tae-Hwan;Jung, Jee-Hee
    • Geomechanics and Engineering
    • /
    • v.18 no.1
    • /
    • pp.59-69
    • /
    • 2019
  • Grout injection is mainly used for permeability reduction and/or improvement of the ground by injecting grout material into pores, cracks, and joints in the ground. The oscillatory grout injection method was developed to enhance the grout penetration. In order to verify the level of enhancement of the grout, field grout injection tests, both static and oscillatory tests, were performed at three job sites. The enhancement in the permeability reduction and ground improvement effect was verified by performing a core boring, borehole image processing analysis, phenolphthalein test, scanning electron microscopy analysis, variable heat test, Lugeon test, standard penetration test, and an elastic wave test. The oscillatory grout injection increased the joint filling rate by 80% more and decreased the permeability coefficient by 33-68%, more compared to the static grout injection method. The constrained modulus of the jointed rock mass was increased by 50% more with oscillatory grout injection compared to the static grout injection, indicating that the oscillatory injection was more effective in enhancing the stiffness of the rock mass.