• Title/Summary/Keyword: cooling flows

Search Result 191, Processing Time 0.028 seconds

The Effect of the Collision Process Between Molecules on the Rates of Thermal Relaxation of the Translational-Rotational-Vibrational Energy Exchange (분자간 충돌과정에 따른 병진-회전-진동에너지의 이완율)

  • Heo, Joong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1494-1500
    • /
    • 2004
  • A zero-dimensional direct simulation Monte Carlo(DSMC) model is developed for simulating diatomic gas including vibrational kinetics. The method is applied to the simulation of two systems: vibrational relaxation of a simple harmonic oscillator and translational-rotational-vibrational energy exchange process under heating and cooling. In the present DSMC method, the variable hard sphere molecular model and no time counter technique are used to simulate the molecular collision kinetics. For simulation of diatomic gas flows, the Borgnakke-Larsen phenomenological model is adopted to redistribute the translational and internal energies.

Measurements of Turbulent Flows in the $180^{\circ}$ Curved Duct by Hot-wire Anemometer (열선유속계를 이용한 $180^{\circ}$ 곡덕트 내 난류유동의 측정)

  • Han, Seong-Ho;Kim, Won-Kap;Choi, Young-Don
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.729-734
    • /
    • 2003
  • This paper reports the characteristics of the three dimensional turbulent flow in the rectangular-sectioned 180 degree bends by Hot-wire anemometer. Grande and Kool proposed a cooling law for the measurements of the flow through the narrow passage. The authors noticed that the calibration coefficients of original method are not constant and fairly sensitive to the flow approaching angle. Measured voltages are converted to three velocity and six Reynolds stress components using the modified method in which the coefficients are treated as a function of approaching angle.

  • PDF

Flow Noise in the Outdoor Unit of an Air-conditioner (에어컨 실외기에서의 유동소음)

  • 이승배;이재환;김휘중;최진규;진성훈;박윤서
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.594-601
    • /
    • 1997
  • Propeller fans are commonly equipped in outdoor units of air-conditioners to provide effective cooling in a dried heat exchanger. A new design technique was developed to satisfy requirements of aerodynamic and aeroacoustic performance, which employs the intersection method of two cylinders for mean camber line. Three proto-types of propeller fan including Palm-Shaped, Highly-Swept(PSHS) fan (proto 3)were not only to provide low lift forces for dipole sound, but also to reduce the organized tip vortices interacting with the fan guide causing narrow-banded rotating instabilities. Cross-correlation technique was applied to study flow noise source characteristics for three proto-type fans designed. The cross-correlations between a microphone at far field and a hot-wire sensor at near field show that flows near hub region of proto 3 fan are less organized and the flow structures especially at high flow rate coefficients for proto 3 fan are less correlated with noise generated than other proto-types fans.

  • PDF

A study on the development of the high efficiency condensing heat exchanger (고효율 응축형 열교환기 개발에 관한 연구)

  • Lee, Geum-Bae;Park, Sang-Il;Park, Jun-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.589-601
    • /
    • 1997
  • A computer simulation program of a high efficiency condensing heat exchanger is developed. The flue gas flows outside bare tube bundles both in strong cross flow and in weak counter flow and the cooling water inside the tubes. Condensing heat exchangers achieve high efficiency by reducing flue-gas temperatures to a level at which most of the water vapor in the flue gas is condensed and the latent heat associated with phase change of the water is recovered. The computer model has been verified by comparison with measured data. To verify the model, heat transfer coefficient was adjusted, along with the mass transfer diffusion coefficient and pressure drop coefficient, to achieve agreement between predicted and measured data. The efficiencies of heat exchanger increase 2.3 ~ 8.1% by condensations of 6.3 ~ 62.6% of the water vapor in the flue gas.

Quench characteristics of stainless steel laminated DyBCO coated conductor (스테인레스강 라미네이션된 DyBCO 초전도 선재의 퀜치 특성)

  • Dixit Manglesh;Kim Tae Hyung;Oh Sang Soo;Song Kyu Jeong;Kim Ho Min;Park Kwon Bae
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.1-4
    • /
    • 2005
  • As high temperature superconductor applications became a reality due to increase in coated conductor performance, it is important to understand their stability behavior to design safe electrical power systems. Coated conductors can be stabilized with different metals and alloys for different types of application, to yield excellent electrical, thermal and mechanical performance. We have experimentally studied the dependence of quench and recovery characteristics of stainless steel stabilized coated conductors on the amplitude of current and duration time. Stability test of 3cm long sample were performed in a liquid nitrogen bath cooling condition by applying a short period over current pulses for 50 and 100ms, with amplitude up to ~6 times the critical current. The transport current that flows before and after the current pulse was fixed at about ~80-85% critical current. We analyzed the quench and recovery phenomena of the test sample using the current voltage characteristic.

Local TIGRESS Simulations of Star Formation in Spiral Galaxies

  • Kim, Woong-Tae;Kim, Chang-Goo;Ostriker, Eve C.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.51.1-51.1
    • /
    • 2021
  • Spiral arms greatly affect gas flows and star formation in disk galaxies. We use local 3D simulations of vertically-stratified, self-gravitating, gaseous disks under a stellar spiral potential to study the effects of spiral arms on galactic star formation as well as formation of gaseous spurs/feathers. We adopt the TIGRESS framework to handle radiative heating and cooling, star formation, and ensuing supernova (SN) feedback. We find that more than 90% of star formation takes place inside spiral arms. The global star formation rate (SFR) in models with spiral arms is enhanced by less than a factor of 2 compared to the no-arm counterpart. This supports the picture that spiral arms do not trigger star formation but rather redistribute star-forming regions. Correlated SN feedback produces interarm feathers in both magnetized and unmagnetized models. These feathers live short, have parallel magnetic fields along their length, and are bounded by SN feedback in the lateral direction, in contrast to instability-induced feathers formed in our previous isothermal simulations.

  • PDF

Petrological Characteristics of the Daejeonsa Basalt in the Mt. Juwang area, Cheongsong-gun, Gyeongsang but-do, Korea (경북 청송군 주왕산지역의 대전사 현무암의 암석학적 특성)

  • Koh, Jeong-Seon;Ahn, Ji-Young;Yun, Sung-Hyo
    • Journal of the Korean earth science society
    • /
    • v.21 no.5
    • /
    • pp.553-562
    • /
    • 2000
  • Daejeonsa basalt in the Mt. Juwang area is composed of 12 lava flows alternate with 9 peperites, and each lava and peperite has variable thickness. Globular peperites yielded in Daejeonsa basalt are mixed basalt clasts with reddish shale. Based on field description, when lava flows over unconsolidated wet shale or injectes into unconsolidated wet shale, peperites were formed at the contacts between lava and shale. Daejeonsa basalt are massive lava flows with rare vesicules: some vesicules are found in upper part of a flow unit. The basalt has mainly pseudomorphs of olivine as phenocryst, and also plagioclase and clinopyroxene phenocrysts in rocks with higher Mg-number. Matrix is mainly subophitic texture, sometimes showing ophitic and intergranular textures due to different cooling rate. Clinopyroxene is augite(Wo$_{41.6}$En$_{45.1}$Fs$_{13.3}$), and plagioclase is mostly labradorite(An$_{55.0}{\sim}_{67.7}$), but some is andesine(An$_{44.3}$) and bytownite(An$_{74.5}$). Oxide minerals are composed of titanomagnetite and ilmenite.

  • PDF

Experimental Study on Coefficient of Flow Convection (유수대류계수에 관한 실험적 연구)

  • Jeon, Sang-Eun;Kim, Kook-Han;Kim, Jin-Keun;Yang, Joo-Kyoung
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.314-322
    • /
    • 2003
  • Pipe cooling method is widely used for reduction of hydration heat and control of cracking in mass concrete structures. However, in order to effectively apply pipe cooling systems to concrete structures, the coefficient of flow convection relating the thermal transfer between inner stream of pipe and concrete must be estimated. In this study, a device measuring the coefficient of flow convection was developed. Since a variation of thermal distribution caused by pipe cooling has a direct effect on internal forced flows, the developed testing device is based on the internal forced flow concept. Influencing factors on the coefficient of flow convection are mainly flow velocity, pipe diameter and thickness, and pipe material. Using experimental results from the developed device, the coefficient of flow convection was calculated. Finally, a general prediction model was proposed by theoretical procedures. The proposed prediction model is able to estimate the coefficient of flow convection with flow velocity and material properties of pipe. From comparison with experimental results, the coefficient of flow convection by this model was well agreed with those by experimental results.

Solubility Consideration in Performance Analysis of a $CO_2$ Twin Rotary Compressor (오일 용해도를 고려한 $CO_2$ 트윈 로타리 압축기 성능해석)

  • Kim, Woo-Young;Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.12
    • /
    • pp.842-849
    • /
    • 2007
  • For a $CO_2$ two-stage twin rotary compressor used for heat pump water heater system, changes of $CO_2$ solubility in PAG oil were investigated along the gas passages from the first stage suction to final discharge. Only slight changes in solubility took place in suction chambers for both of the first and second stages, but for compression chambers, solubility variation ranged from 0.115 to 0.136, and from 0.133 to 0.182, respectively for the first and second stages. Calculation of gas flashing in parts of leakage oil flows and of oil contained in control volumes due to solubility changes was conducted and included in gas pressure calculation. For the second stage, gas flashing amounts to around $5%\sim6%$ for most leakage flows. Cooling capacity, compressor input, and COP obtained by calculation were well compared to the experimental results. Effects of operation speed on the compressor performance was also studied: as the shaft speed increased, adiabatic efficiency decreased rapidly due to increased over-compression loss.

Influences of Urban Trees on the Control of the Temperature (도시의 수목이 기온의 조절에 미치는 영향)

  • 김수봉;김해동
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.30 no.3
    • /
    • pp.25-34
    • /
    • 2002
  • The purpose of this paper is to discuss the function of microclimate amelioration of urban trees regarding the environmental benefits of street trees in summer, focusing on the heat pollution-urban heat island, tropical climate day's phenomenon and air pollution. We measured the diurnal variation of air/ground temperatures and humidity within the vegetation canopy with the meteorological tower observation system. Summertime air temperatures within the vegetation canopy layer were 1-2$^{\circ}C$ cooler than in places with no vegetation. Due to lack of evaporation, the ground surface temperatures of footpaths were, at a midafternoon maximum, 8$^{\circ}C$ hotter than those under trees. This means that heat flows from a place with no vegetation to a vegetation canopy layer during the daytime. The heat is consumed as a evaporation latent heat. These results suggest that the extension of vegetation canopy bring about a more pleasant urban climate. Diurnal variation of air/ground temperatures and humidity within the vegetation canopy were measured with the meteorological tower observation system. According to the findings, summertime air temperatures under a vegetation canopy layer were 1-2$^{\circ}C$ cooler than places with no vegetation. Due mainly to lack of evaporation the ground surface temperature of footpaths were up to 8$^{\circ}C$ hotter than under trees during mid-afternoon. This means that heat flows from a place where there is no vegetation to another place where there is a vegetation canopy layer during the daytime. Through the energy redistribution analysis, we ascertain that the major part of solar radiation reaching the vegetation cover is consumed as a evaporation latent heat. This result suggests that the expansion of vegetation cover creates a more pleasant urban climate through the cooling effect in summer. Vegetation plays an important role because of its special properties with energy balance. Depended on their evapotranspiration, vegetation cover and water surfaces diminish the peaks of temperature during the day. The skill to make the best use of the vegetation effect in urban areas is a very important planning device to optimize urban climate. Numerical simulation study to examine the vegetation effects on urban climate will be published in our next research paper.