• Title/Summary/Keyword: cooling condition

Search Result 1,241, Processing Time 0.038 seconds

A Study on the Automatic Sensing Device for Gas Leakage of Cooling Plate Using the Microprocessor System

  • Wang, Jee-Seok;Yoon, Hee-Jong;Kang, Ki-Seong;Kim, Jong-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.329-334
    • /
    • 2011
  • The cooling water circulation plates had been used to drop the temperature of refractory outside shell of common cooling system by using cooling plate or stave type. When they are attacked by surrounding gas, they are corroded and the water flows in the refractory due to leakage of water. So, the life of refractory material is shortened and changed due to the worse conditions of cooling system. The automatic sensing device for water leakage of cooling plate is developed to check the position of trouble by using the microprocessor system when cooling water leak and gas are flowed into the cooling plate through the leakage position. The flowed gas is detected in the micro-process system which delivers the detected position of cooling plate or stave to main control room through the wireless-radio relay station. This system can be possible to detect the position of cooling plate or stave against the water leakage part immediately and then deliver the signal to main control room by using the microprocessor system and wireless-radio relay station. This system will be developed in changing the working condition from manual system to unmanned auto alarm system.

A Study on the Performance Characteristics of an Absorption Chiller for Variable Cooling Water Flow Rate at Partial Load Conditions (흡수식 냉온수기의 부분부하에 따른 냉각수 변유량시 성능특성에 관한 연구)

  • 박찬우;조현철;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.26-33
    • /
    • 2004
  • In general, an absorption chiller or heat pump is operated under the constant cooling water flow rate condition even though the system works with a partial load. The objective of this paper is to study the effect of the cooling water flow rates and the temperature of cooling water on the system performance to find the energy saving methode for the partial load operation of the double effect $H_2O$/LiBr absorption chiller. It is found that the performance of the system is sensitive to the temperature of cooling water than the cooling water flow rate, so the decrease of the performance due to reducing the cooling water flow rate can be overcome with the reduction of the cooling water temperature by 1$^{\circ}C$. The flow rate of the cooling water flow rate ranges from 50% to 100% of the flow rate at normal conditions with a partial load. It is also found that the operation cost of the cooling water pump and the cooling tower can be reduced by 23%.

A study on an improvement of indoor cooling tower efficiency (지하역사 실내형 냉각탑 성능개선 연구)

  • Bae, Sung-Joon;Hwang, Sun-Ho;Shin, Chang-Hun;Pyo, Soo-Chul
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1726-1735
    • /
    • 2008
  • Seoulmetro has operated the air cooling equipment for 57 stations to improve services focused on our customers who use Seoulmetro during the summer season and has established every year. However, a new set of problems has arisen with the cooling tower to support a heat exchange of cooling water. The most important matter is loss of efficiency in the cooling tower. The leading cause of this problem is that we use an indoor type. As the cooling tower room is located in the underground of the city because of the residents near the station. Therefore It is difficult to establish the cooling tower on the ground. But it is unsuitable for the location requirements of the underground type because it has a limited space to set up the air cooling equipment, for example, the cooling tower and a ventilating opening. As a result of such an unfavorable condition, the cooling tower doesn't work efficiently and the warmth of cooling water because of insufficiency of a heat exchange and a refrigerator's technical obstacle such as a high-temperature and a high-pressure has arisen. To prevent this situation, the operator tend to reduce refrigerant. Accordingly, the efficiency of the air conditioning is getting lower and lower. Study wishes to analyze the matter to improve indoor cooling tower efficiency and recommend a best practice for a person who manage the establishment.

  • PDF

Effect of Welding Heat Input and PWHT Cooling Rate on Mechanical Properties of Welded Region at SAW of 1.25Cr-0.5Mo Steel for Pressure Vessel (압력용기용 1.25Cr-0.5Mo 강의 Submerged Arc Welding시 입열 및 PWHT 냉각속도가 용접부 기계적 성질에 미치는 영향)

  • Lee Dong-Hwan;Park Jong-Jin
    • Journal of Welding and Joining
    • /
    • v.22 no.5
    • /
    • pp.26-31
    • /
    • 2004
  • In order to propose the optimum welding condition for field application, the effects of welding heat input and cooling rate at PWHT on the mechanical properties were investigated. Submerged arc welding of 1.25Cr-0.5Mo steel for pressure vessel was conducted at welding heat inputs of 15.2kJ/cm, 30.9kJ/cm, and 44.8kJ/cm, and cooling rates of 184$^{\circ}C$/hr, 55$^{\circ}C$/hr, and 2$0^{\circ}C$/hr at PWHT. From the test results, as the welding heat input increase up to 30.9kJ/cm, the changes of microstructure and impact toughness were small. At the heat input of 44.8kJ/cm, however, toughness decreased obviously due to the coarsening of coarse-grained HAZ and formation of ferrite at bainite grainboundary of weld metal. On the other hand, cooling rates at PWHT did not effect on the changes in microstructure and mechanical properties. Even though tensile strength and impact toughness at all welding conditions of this study were above the minimum specification requirement, it was confirmed that heat input of 30.9kJ/cm was the optimum welding condition to improve welding performance by higher heat input.

Analysis of Urban Warming Phenomenon using Degree days in Major Korean Cities (냉난방도일을 이용한 우리나라 주요도시의 도시승온화현상 특성분석)

  • Kim, Hae Dong;Park, Myeong Hui;Song, Gyeong Suk
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.189-196
    • /
    • 2004
  • Characteristics of urban wanning phenomenon were studied using degree days for three big cities(Seoul, Busan, Daegu) adjacent to airport. Time variation of the cooling and heating degree days was analyzed using the daily mean air temperature data measured at the six meteorological observatory for long-term periods(25~43years). The results for the big cities are as followings: 1) It was found that the heating degree days trended to decrease from year to year. 2) The cooling degree days were nearly unchanged during the same analysis periods. 3) The number of days calling for air-heating also tended to decrease as time passes. 4) Those of air-cooling were nearly unchanged during the same time. It suggests that the change of air-heating condition owing to urbanization came in evidence in the winter season, but that of air-cooling condition was slight in the summer season. On the other hand, the long-term trends of degree days were very small in airport areas except for Kimhae airport. Hence, the gaps of degree days between big cities and rural airport areas are increasing.

The Effect of Cooling method on the Surface Reaction Zone of CP Titanium Casting Body (티타늄 주조체 냉각방법이 표면반응층에 미치는 영향)

  • Moom, Soo;Choi, Seog-Soon;Moon, Il
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.203-210
    • /
    • 2002
  • This test is to conduct applied research the reaction area of the Ti-cast metal body which is made use of Dental Phosphate-silica alumina bonded investment material selling at a market, and the cooling method is how to effect on the acicular. The experimentation is as followings, 1. Experimental specimens After invest with Dental Phosphate-silica alumina bonded investment material, the $10{\times}10{\times}1.0mm^3$ wax pattern was casted by Dental high vacuum argon centrifugal casting machine. 2. Test We can analyze SEM/EDS, XRD utilize the fractography(an optical microscope). 3. Conclusion The pure cast metal body constituted of reaction products layer, stability layer and contamination layer. This pure cast have no connection with the cooling condition. The pure Titanium shows difference in a component distribution according to the cooling condition. Through this experimentation we can establish that acicular in the pure Ti-cast metal is consist of Hexagonal structure a=2.9505$\AA$, c=4.6826$\AA$.

  • PDF

Chemical Cleaning of Copper Corrosion Product Using EDTA.2Na Salt and Effect of Surface Treatment by NALCO-39L (EDTA.2Na를 이용한 구리 부식생성물의 화학세정 및 NALCO-39L에 의한 표면처리효과)

  • 이한철;이창우;현성호
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.86-92
    • /
    • 1999
  • This study was carried out to investigate the effect of chemical cleaning of corrosion product on cooling system made of copper as a basic material and using cooling water as pure water. We studied chemical cleaning condition that minimizes the influence on basic material by means of EDTA solution so as to eliminate the slurry in cooling system. In addition, the proper amount of NALCO-39L (Nitrite-Borate-BZT mixture) as a inhibitor was determined in order to protect the copper in cooling system against corrosion after chemical cleaning and the effect of corrosion resistance on the copper surface treated was excelent in comparison with surface untreated. As a result, we found that the main components of sludge in cooling system produced by corrosion of copper were $Cu_2O$, CuO, Cu, and Fe. The optimum condition of chemical cleaning was 400ppm EDTA solution at $60^{\circ}C$. Inhibitor concentration needed to treat the surface of pure copper was 15~20ppm per unit area and corrosion rate of copper treated with 500ppm inhibitor solution for 72 hrs at $60^{\circ}C$ was remarkably decreased as compared with that of pure copper.

  • PDF

Thermal Characteristics of the High Frequency Motor Spindle according to the Bearing Preloads and Cooling Conditions (예압과 냉각조건에 따른 고주파 모터 내장형 주축계의 열특성)

  • Choi, Dae-Bong;Kim, Soo-Tae;Jung, Sung-Hun;Kim, Jin-Han;Kim, Yong-Kee
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.6
    • /
    • pp.31-36
    • /
    • 2005
  • Use of the high frequency motor spindles are increasing for the high speed machine tools recently. The important problem in the high speed spindles is to reduce and minimize the thermal effect by the motor and ball hearings. Thermal characteristics according to the bearing preload and spindle cooling are studied for the spindle with the oil mist lubrication and high frequency motor. Temperature distribution and thermal displacement according to the spindle speed, preload and flow rate are measured. Temperature distribution and thermal displacement of the high speed spindle system can be estimated reasonably by using the three dimensional model through the finite element method. The results of analysis are compared with the measured data. This study supports thermal optimization and find out more effective cooling condition. This paper show that the suitable preload and spindle cooling are very effective to minimize the thermal effect by the motor and ball bearings.

On Cutting Characteristics Change of Low Temperature Cooling Tool -Cutting Characteristics of Cage Motor Rotor- (저온냉각공구의 절삭특성 변화 -모타 회전자의절삭특성-)

  • 김순채
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.37-43
    • /
    • 1995
  • The cutting process of cage motor rotor require high precision and good roughness, the surface roughness fo cutting face is very important factor with effect on the magnetic flux density of cage motor rotor. The paper describes a cause of decrease in the cutting force and roughness on low temperature cooling tool by means of analysis on the mechanism of force system at cutting condition and experimental findings. The main results as compared with the room temperature cutting are as follow : 1) The cutting resistance decreased due to low temperature cooling tool. 2) The surface roughness decreased due to low temperature cooling tool. 3) The low temperature cooling tool effected machinability of the cutting direction in machined surface. 4) The low temperature cooling decreased burr of corner in feed direction.

  • PDF

A Study on the Solidified Structures of Al-Pb Alloy Solidified by Rapid Cooling (급냉응고 시킨 Al-Pb 합금의 응고조직에 관한 연구)

  • Kim, Yong-Kil;Kim, Tong-Hoon
    • Journal of Korea Foundry Society
    • /
    • v.2 no.1
    • /
    • pp.12-18
    • /
    • 1982
  • The present investigation was made to abtain a fine distribution of Pb Particles in AL - Pb binary alloys , which have a broad miscibility gap and large specific difference, by means of rapid Cooling of the molten alloys. Al-2.4% Pb, Al-5.5wt% Pb and Al-8.0wt % Pb alloy were used. The rapid cooling operation was performed by free falling of homogeneous liquid Al-Ph alloys into the water-cooled copper mold, and thermal analysis was made. Microstructures were observed, and variations of size and number of Pb particles were analysicle analyzer. By the result of examination with the varing cooling rates 100 to $210^{\circ}C/sec$ fine distributions of Pb particles were obtained with high cooling rate. Under same cooling condition, the best rapid cooling effect was recognized in Al-5.5wt% Pb alloy.

  • PDF