• Title/Summary/Keyword: cool down time

Search Result 68, Processing Time 0.026 seconds

Establishment of the Optimum Culture Conditions for Mozzarella Cheese manufacturing by Streptococcus macedonicus LC743 with Immunomodulating Activity (면역 활성능을 가진 Streptococcus macedonicus LC743을 이용한 모짜렐라 치즈 제조의 최적 배양조건 확립)

  • Park, Sun-Young;Han, Noori;Lim, Sang-Dong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.33 no.3
    • /
    • pp.215-221
    • /
    • 2015
  • This study aimed to establish the optimum culture conditions for Mozzarella cheese by using Streptococcus macedonicus LC743, a strain selected for its immunomodulatory activity. For process optimization, 1.0% and 2.0% strain was inoculated and incubated at $32^{\circ}C$ and $35^{\circ}C$, respectively. The general components, bacterial count, total solids, yields, and immunomodulatory activity of the Mozzarella cheese were investigated. When the strain was inoculated at 2.0% and incubated at $32^{\circ}C$, the product quality and immunomodulatory activity was optimal and required minimal processing time. Therefore, 2.0% of S. macedonicus LC743 starter culture was added to milk at $32^{\circ}C$, after pasteurization at $63^{\circ}C$ for 30 min, and agitated for 4~5 min after addition of $230{\mu}L/kg$ of rennet. Curd was made by setting the milk 25~35 min after addition of 0.01~0.02% calcium chloride. The curd was cut at 0.1~0.12% acidity (81 min later) and after heating the cheese to up to $43^{\circ}C$. Whey was removed at an acidity of 0.17~0.18% by agitation for 53 min. Next, cheddaring for 210 min up to an acidity of 0.6~0.65%, stretching at $72{\sim}75^{\circ}C$, and molding at $65{\sim}70^{\circ}C$ were performed, and the product was allowed to cool down to $5^{\circ}C$. Salting was done with a solution of $18{\sim}20^{\circ}B{\acute{e}}$ at $12^{\circ}C$ for 20 min and drying occurred at 80~90% relative humidity at $10^{\circ}C$ for 2~3 days.

  • PDF

Detection of Thermal Ratcheting Deformation for Cylindrical Shells by Ultrasonic Guided Wave (유도초음파를 이용한 원통형 쉘의 열 라체팅 변형 탐지)

  • Joo, Young-Sang;Lee, Hyeong-Yeon;Kim, Jong-Bum;Park, Chang-Gyu;Lee, Jae-Han
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.297-305
    • /
    • 2006
  • The thermal ratcheting deformation at the reactor baffle and upper internal structure of the liquid metal reactor (LMR) can occur due to movement of the hot sodium free surface. In in-service inspection of reactor internals of LMR, a new inspection technique should be developed for the detection of the thermal ratcheting damage. In this study, an inspection technique using ultrasonic guided wave is proposed for the detection of the thermal ratcheting damage of cylindrical vessels. A 316L stainless steel cylindrical shell specimen has been prepared. The thermal ratchet structural tests were cyclically performed by heat-up up to $550^{\circ}C$ with steep temperature gradients along the axial direction after cool-down by cooling water. Ultrasonic guided wave propagation has been characterized by analysis of dispersion curve of the stainless steel plate. The zero-order antisymmetric $A_0$ guided wave has been selected as the optimal mode for detection of the ratcheting deformation. It is confirmed that the thermal ratcheting deformation can be detected by the measurement of transit time difference of circumferentially propagated $A_0$ guided waves.

Three-dimensional Numerical Prediction on the Evolution of Nocturnal Thermal High (Tropical Night) in a Basin

  • Choi, Hyo;Kim, Jeong-Woo
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • v.25 no.1
    • /
    • pp.57-81
    • /
    • 1997
  • Numerical prediction of nocturnal thermal high in summer of the 1995 near Taegu city located in a basin has been carried out by a non-hydrostatic numerical model over complex terrain through one-way double nesting technique in the Z following coordinate system. Under the prevailing westerly winds, vertical turbulent fluxes of momentum and heat over mountains for daytime hours are quite strong with a large magnitude of more than $120W/\textrm{m}^2$, but a small one of $5W/\textrm{m}^2$ at the surface of the basin. Convective boundary layer (CBL) is developed with a thickness of about 600m over the ground in the lee side of Mt. Hyungje, and extends to the edge of inland at the interface of land sea in the east. Sensible heat flux near the surface of the top of the mountain is $50W/\textrm{m}^2$, but its flux in the basin is almost zero. Convergence of sensible heat flux occurs from the ground surface toward the atmosphere in the lower layer, causing the layer over the mountain to be warmed up, but no convergance of the flux over the basin results from the significant mixing of air within the CBL. As horizontal transport of sensible heat flux from the top of the mountain toward over the basin results in the continuous accumulation of heat with time, enhancing air temperature at the surface of the basin, especially Taegu city to be higher than $39.3^{\circ}C$. Since latent heat fluxes are $270W/\textrm{m}^2$ near the top of the mountain and $300W/\textrm{m}^2$ along the slope of the mountain and the basin, evaporation of water vapor from the surface of the basin is much higher than one from the mountain and then, horizontal transport of latent heat flux is from the basin toward the mountain, showing relative humidity of 65 to 75% over the mountain to be much greater than 50% to 55% in the basin. At night, sensible heat fluxes have negative values of $-120W/\textrm{m}^2$ along the slope near the top of the mountain and $-50W/\textrm{m}^2$ at the surface of the basin, which indicate gain of heat from the lower atmosphere. Nighttime radiative cooling produces a shallow nocturnal surface inversion layer with a thickness of about 100m, which is much lower than common surface inversion layer, and lifts extremely heated air masses for daytime hours, namely, a warm pool of $34^{\circ}C$ to be isolated over the ground surface in the basin. As heat transfer from the warm pool in the lower atmosphere toward the ground of the basin occurs, the air near the surface of the basin does not much cool down, resulting in the persistence of high temperature at night, called nocturnal thermal high or tropical night. High relative humidity of 75% is found at the surface of the basin under the moderate wind, while slightly low relative humidity of 60% is along the eastern slope of the high mountain, due to adiabatic heating by the srong downslope wind. Air temperature near the surface of the basin with high moisture in the evening does not get lower than that during the day and the high temperature produces nocturnal warming situation.

  • PDF

The Effects of High-Intensity Aerobic Interval Training In The Elderly With Myocardial Infarction (노인 심근경색 환자에서 고강도 간헐적 유산소운동의 효과)

  • Kim, Ji Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.267-274
    • /
    • 2019
  • To investigate the effect of high-intensity interval training (HIIT) on the outcomes of cardiac rehabilitation(CR) in elderly and younger patients with myocardial infarction(MI). Of the MI patients who received hospital-based CR from 2015 to 2017, we retrospectively reviewed the medical records of the patients who continued follow-up through the outpatient clinic. A total of 39 patients (20 elderly patients (${\geq}60year$($64.1{\pm}3.6$)) and 19 younger patients (< 60 year($55.6{\pm}2.3$)) was included in this study. The HIIT program was composed of 10 minutes of warm-up, 30 minutes of interval aerobic exercise, and 10 minutes of cool down. The aerobic exercise based on their initial exercise tolerance test outcome consisted of 3-minute usual intensity phase (60-70% of heart rate/VO2 reserve) and 4-minute of high-intensity phase (70-90% of heart rate/VO2 reserve). Exercise capacity was measured by exercise tests before and after hospital- based CR. Before CR, elderly group had a significantly lower exercise capacity in Exercise time, peak VO2, METs, Anaerobic threshold, VEmax, 02pulse than younger group. Both group showed similar improvement of cardiopulmonary exercise capacity after CR. And HIIT is safe and effective in elderly patients. It is considered necessary to further expansion for the participation of high intensity interval training in elderly patients.

Optimization of Plain Jacked Vessel Design in Adhesive Production Process Using Computational Fluid Dynamics (Computational Fluid Dynamics를 활용한 점/접착 생산 공정 내 Jacketed Vessel 설계 최적화)

  • Joo, Chonghyo;Park, Hyundo;Cho, Hyungtae;Kim, Junghwan
    • Applied Chemistry for Engineering
    • /
    • v.31 no.6
    • /
    • pp.596-602
    • /
    • 2020
  • Blending process of adhesive production has a cooling process to cool down the temperature of the solution which was heated up to 76 ℃ with a mineral insulated (MI) cable by 30 ℃ at room temperature. Using a MI cable in the adhesive production process makes the production inefficient because it takes about 10 h for the cooling process. If a jacketed vessel is used instead of the MI cable, it would shorten the cooling downtime without any additional cooling system by using cold water. However, there are various types of jacketed vessels, and thus the most suitable type should be found before set up. In this study, we designed the optimized jacketed vessel for the adhesive production process by calculating the cooling downtime, which impacts production efficiency, as a function of the jacket types using computational fluid dynamics. As a result, the cooling performance of the plain jacket was 32.7% superior to that of the half-pipe coil jacket with the same height. In addition, the plain jacket with 60% spiral baffle reduced the cooling downtime and operating time by 80.4% and 25.1%, respectively.

A Preliminary Study of the Effect of 4 Week Backward Walking Exercise on Cervical Angle and Gait Parameters in College Students with Moderate Forward Head Posture (중등도 앞쪽 머리 자세 대학생을 대상으로 4주간 뒤로 걷기 운동이 목뼈 각도와 걸음 변수에 미치는 예비 연구)

  • Park, Han-Kyu;Kim, Gun-Ho;Lee, Min-Hyeok;Hwang, Su-Yeon;Park, Mi-Dam;Kim, Beom-Su;Kim, Mi-Ju
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.4
    • /
    • pp.241-250
    • /
    • 2022
  • Purpose : The purpose of this study was to investigate the effect of backward walking exercise on changes in the cervical angle and gait parameters in subjects with moderate forward head posture. Methods : Four subjects were selected for this study. In particular, subjects with an average of 43 subjects with moderate craniovertebral angles were selected as the criteria for subject selection. The exercise program consisted of a 5 minutes warm-up exercise, 20 minutes main exercise, and 5 minutes cool-down exercise. In the main exercise, the treadmill speed was 2.5 km/h for men, 2.0 km/h for women in the first week, from the 2nd week to the 4th week, it was increased by 0.5 km/h every week. Results : Craniovertebral angle increased by 2.06±2.46 ° before and after the backward walking exercise, and craniorotational angle decreased by -1.69±3.33 ° before and after exercise. As for the gait parameters, in the amount of change before and after the backward walking exercise, the left foot pressure was 4.58±5.70 % from front to back and the right foot pressure was 5.08±3.06 % from front to back. The left step length and right step length showed a change of -.33±4.43 cm and -2.08±7.26 cm, respectively. stride length showed a change of -2.59±11.18 cm. The left and right stance phase showed a change of -1.02±2.03 % and -1.23±1.54 %, respectively. The left and right swing phase showed changes of 1.02±2.03 % and 1.22±1.53 %, respectively. The left and right step times were -.01±.06 sec and -.02±.12 sec, respectively. The stride time showed a change of -.03±.18 sec. Conclusion : Changes in cervical angle and gait parameters were confirmed by performing backward walking exercise for subjects with moderate forward head posture for 4 weeks. Therefore, additional research should be conducted based on this case study.

A Study on Smoking and Relevant Factors among High School Students in Seoul Province (서울시내 일부 고등학생의 흡연 관련요인 분석)

  • Ahn, Byoung Ho;Park, Keeho;Kye, Su Yeon
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.13 no.3
    • /
    • pp.57-71
    • /
    • 2012
  • Objectives: This study examines the situation regarding smoking among high school students in Seoul Province and identifies smoking-related factors. Methods: The study sample consisted of 1,000 high school second-grade students from 6 high schools in Seoul. The PRECEDE model was used to assess the students' needs. We carried out an educational diagnosis on attitudes, outcome expectations and social norms. Date were collected from June. 7 to 21, 2011, and were analyzed using SPSS-15.0 according to the study objectives. Results: Of 906 respondents, 9.4% had experiences to smoking: 12.7% were male and 5.7% were female. Smoking-related factors from among general characteristics were statistically significant depending on the degree of gender($x^2$=14.515, p=.001), school performance($x^2$=40.289, p=.001) and friends 'smoking status($x^2$=88.615, p=.001). Factors concerning attitudes toward smoking were statistically significant depending on the students' perceptions as follows: 'Smoking is fun(t=-14.801, p=.000)', 'Smoking looks cool(t=-10.349, p=.000)', 'People who smoke have more friends(t=-11.295, p=.000)', 'Smoking helps me manage stress(t=-15.059, p=.000)' and 'Smoking is not harmful to the body if you exercise(t=-6.388, p=.000)'. Factors concerning outcome expectations were statistically significant depending on their perceptions as follows: 'Tobacco smells good(t=-8.939, p=.000)' and 'Smoking helps in weight management (t=-7.304, p=.000)'. Factors concerning social norms were statistically significant depending on the following perception: 'My friends will not like it if I smoke(t=4.605, p=.000)'. The following influence high school students attitudes toward smoking: School performance (OR=11.66, 95%CI=1.67~81.37; OR=18.27, 95%CI=2.58~129.24; OR=26.74, 95%CI=3.06~233.79), Friends smoking status(OR=80.05, 95%CI=6.94~922.77), 'Smoking is fun(OR=12.90, 95%CI=3.87~43.04; OR=63.41, 95%CI=10.66~377.09)', 'Smoking looks cool(OR=0.15, 95%CI=0.03~0.64)', 'Smoking is not harmful to the body if you exercise(OR=1.44, 95%CI=0.03~0.62)', 'When there is no work to do, smoking is a good way to pass the time(OR=21.68, 95%CI=4.27~109.90)', 'When you are angry, smoking calms you down.(OR=13.39, 95%CI=3.92~45.65; OR=8.69, 95%CI=1.67~45.13)' and 'My parents consider it important that I do not smoke(OR=10.05, 95%CI=1.00~100.43)'. Conclusions: The study suggests that effective ways to discourage of high school students from smoking are changing their attitudes toward smoking, reducing the motivation to smoke, and controlling the number of cigarettes. Therefore, aiming at preventive education. Schools must provide accurate information about the effects of smoking. Thus, health education should actively involve preventive education not only in schools but also at home, the societal and national levels. Cooperation between various sectors of society is required for this.

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF