• 제목/요약/키워드: conventional water treatment

검색결과 567건 처리시간 0.028초

기후변화 대응을 위한 수처리 여과시스템 선정 방안 연구 (Study on Selection of Water Treatment Filtration System to Cope with Climate Change)

  • 황윤빈;박기학
    • 한국기후변화학회지
    • /
    • 제9권1호
    • /
    • pp.75-80
    • /
    • 2018
  • The problem of water shortages and water related disasters caused by climate change has increased the seriousness of water problems and the importance of water treatment technology capable of securing clean water is expanding. In this study, we analyzed not only the water pollutant generated by the filtration system technology of various water treatment technologies but also the indirect greenhouse gas emissions generation, and analyzed the influence on the environment. The subjects of study are Fabric Filter, Reverse Osmosis System and Pressurized Microfiltration Device which are widely used for water treatment and we analyzed the impact on the environment using the Life Cycle Assessment (LCA) method using the electricity amount necessary for use, the water purification efficiency, the throughput per ton and the cost. The amount of greenhouse gas generated when the Pressurized Microfiltration Device operates for 1 year is $2.15E+04kg\;CO_2-eq$., Fabric Filter is $3.29E+04kg\;CO_2-eq$., and Reverse Osmosis System is $1.68E+05kg\;CO_2-eq$. As a result of analyzing the amount of greenhouse gas generated at the time of purifying 1 ton of the Pressurized Microfiltration Device and the conventional filtration system, the Pressurized Microfiltration Device was $20.5g\;CO_2-eq$., Fabric Filter was $34.7g\;CO_2-eq$., and Reverse Osmosis System was $191.7g\;CO_2-eq$. The amount of greenhouse gas generated was calculated to be 41.0% less than that of the Fabric Filter by the Pressurized Microfiltration Device and 89.3% less than the Reverse Osmosis System. From the viewpoint of climate change, it is necessary to select a filtration system that takes climate change into account, not from the viewpoint of water quality removal efficiency and economic efficiency according to future water treatment applications, and it is necessary to select a water treatment filtration system more researches and improvements will be made for.

가죽, 모피 가공 및 제조업 폐수처리시설의 경제성 평가 (Economical Assessment of Wastewater Treatment Facilities in Leather Tanning and Finishing Industry)

  • 김재훈;양형재;권오상;이성종
    • 한국물환경학회지
    • /
    • 제23권1호
    • /
    • pp.131-137
    • /
    • 2007
  • Industrial wastewater management guideline and evaluation model of Best Available Technologies for the leather tanning and finishing industry was developed as an economical evaluation model using evaluation of BAT including economical evaluation combined with cost analysis model and cost annualization model in considering of economical factors and non-water environmental factors. It was verified that approximately 10% will be increased annually to modify conventional treatment process ($3,700m^3/d$) of J leather wastewater treatment plant to advanced process of K leather wastewater treatment plant.

갈대(Phragmites australls)수초를 적용한 바이오필터에서의 하수처리시설 악취저감기술 (Odor Reduction Technology in Sewage Treatment Facility Using Biofilter with Reed Grass(Phragmites australls))

  • 정진도;김규열
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.373-382
    • /
    • 2013
  • In this study, a biological odor treatment system was proposed to remove odor(foul smell) materials causing several problems in the closed sewage treatment plant. This odor treatment system was composed of a two-step biofilter system in one reactor. The two-step biofilter reactor was constructed with natural purification layer in upper part and artificial purification layer in lower part. The reed grasses of water purification plants were planted in the surface area and mixed porous ceramic media were filled with the lower part of biofilter reactor. By using the above experimental apparatus, the ammonia gas removal efficiency was attained to 98.3 % and the hydrogen sulfide gas removal efficiency was appeared more than 97.7 % which shows more effective than the conventional odor removal process.

정수처리에서의 다이옥신 제거 및 2, 3, 7, 8-TeCDF 생성 (The Removal of Dioxins and the Formation of 2, 3, 7, 8-TeCDF in Drinking Water Treatment in Japan)

  • 김현구
    • 한국물환경학회지
    • /
    • 제24권6호
    • /
    • pp.758-766
    • /
    • 2008
  • 먹는물 처리 전후 다이옥신류의 동족체 패턴 및 제거율을 평가하기 위해서 42개의 일본 정수처리장에서 2년간 122개의 시료를 채취해 dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) 및 coplanar polychlorinated biphenyls (Co-PCBs)를 분석하였다. 다이옥신류의 평균 농도와 독성등가값 (toxic equivalent, TEQ)은 원수와 처리수에서 각각 60.24 pg/L (0.14 pg-WHO-TEQ/L), 4.15 pg/L (0.016 pg-WHO-TEQ/L)였다. 먹는물의 다이옥신류 기여 농도는 일일섭취량 (tolerable daily intake (TDI), 4 pg-TEQ/kg/day)의 0.016%이었다. 정수처리에 의한 다이옥신류의 평균 TEQ 제거율은 88% 이상이었다. 그러나 112개의 샘플에서 2, 3, 7, 8-TeCDF (tetrachlorodibenzofuran)의 농도는 17% 증가하였다. 따라서, 2, 3, 7, 8-TeCDF의 농도에 영향을 미치는 공정을 파악하기 위하여 고도정수처리 및 일반정수처리에서의 제거율을 조사하였다. 다이옥신 동족체(congener)인 TeCDF와 non-ortho-PCB는 고도처리 및 표준정수처리에서 염소소독처리 후 TEQ 농도가 증가함을 보여, 먹는물 중 2, 3, 7, 8-TeCDF 농도는 염소소독처리에 의해 상승한 것으로 밝혀졌다.

이상 혐기성 막공정에 의한 침출수 처리 모니터링 (Monitoring of the Treatment of Leachate by Two Phase Anaerobic Membrane Process (TPAMP))

  • 황문현;현승훈;장남정;조재원;김인수
    • 한국물환경학회지
    • /
    • 제18권2호
    • /
    • pp.151-157
    • /
    • 2002
  • Landfill leachate is one of highly contaminated and heterogeneous wastewater. The leachate from initial landfill can be treated by anaerobic process because it contains biodegradable matters, particularly, volatile fatty acids (VFAs). However, the anaerobic treatment of leachate is generally required longer hydraulic retention time (HRT) than aerobic process and another treatment process to satisfy effluent concentration. Therefore the modification of conventional anaerobic treatment is needed. Two phase anaerobic membrane process (TPAMP) is an integrated membrane process to be able to separate anaerobic metabolism into two phase which are acidogenesis and methanogenesis for improvement of anaerobic treatment efficiency. In this study, the efficiency of TPAMP and conventional anaerobic treatment were compared in terms of HRT, effluent SCOD, VFAs Membrane used in TPAMP was the UF of capillary type with the surface area of $0.048m^2$. The average effluent SCOD of conventional anaerobic treatment was 1352 mg/L and the removal was 96 % at HRT 60 days, while in TPAMP, 927 mg/L and 98% at HRT 30 days.

Membrane Technology for Waste Water Recovery

  • Okazaki, Minoru
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1996년도 추계 총회 및 학술발표회
    • /
    • pp.22-33
    • /
    • 1996
  • With the experience of the 1994 drought, and the shortage of water resources in Japan, it has been re-informed upon us ensure and maintain the stability of water resources. Accordingly, with each plant, a serious appraisal has begun looking at the re-use of waste water. Membrane technology is an important process for waste water recovery. Effluent kom waste water facilities changes the quality of water significantly. The conventional pre-treatment of RO is hard to supply good quality feed water to RO in the waste water recovery system. The microfiltration system as a pre-treatment of RO in the paper overcomes the fouling with the air backwash and is operated in direct flow mode at a low pressure producing a high flux. The paper will focus the waste water recovery using membrane technology and many examples will be given.

  • PDF

보관조건과 열처리에 따른 복합레진의 표면경도에 관한 연구 (A STUDY ON SURFACE HARDNESS OF COMPOSITE RESINS ACCORDING TO STORAGE CONDITON AND HEAT TREATMENT)

  • 강승훈;민병순
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.194-204
    • /
    • 1994
  • The purpose of this study was to evaluate the surface hardness of composite resins according to heat treatment. storage condition and storage time. In this study. two kinds of composite resin inlays and one kind of conventional posterior composite resin were used as experimental materials. One hundred eighty composite resin specimens were constructed from composite resin inlays and conventional posterior composite resin. The conditions of this study were heat treatment. storage condition and storage time. Hardness readings were taken from the top surface of each samples using the Vickers microhardness tester(MHT-l. Matsuzawa. Japan}. The following results from this study were obtained: 1. Regardless of storage condition. both composite resin inlay and conventional posterior composite resin have a higher surface hardness under heat treatment than not. 2. Composite resins with heat treatment have a higher surface hardness under dry storage than under water immersion. 3. In case of Clearfil Photo Posterior and Brilliant Enamel with heat treatment. there was no significant difference with time. but Clearfil CR Inlay with heat treatment. there was statistical difference after 24 hours. 4. Surface hardness of composite resins with coarse hybrid type was higher than that of composite resin with fine hybrid type.

  • PDF

고도정수처리를 위한 HCPAC-MBR 공정에서의 소독부산물 저감에 관한 연구 (A Study on Removal of Disinfection By-products in High Concentration Powdered Activated Carbon Membrane Bio-reactor Process for Advanced Water Treatment)

  • 이송희;장성우;서규태
    • 상하수도학회지
    • /
    • 제20권1호
    • /
    • pp.27-34
    • /
    • 2006
  • This study was conducted to evaluate the performance of a membrane bioreactor filled with high concentration of powdered activated carbon (HCPAC-MBR) to reduce DBPs at the drinking water treatment. The pilot system was installed after the rapid sand filtration process whose plant was the conventional treatment process. The removal efficiencies of DBPs were measured during pilot operation period of 2 years. HAA and THM removal rates could be maintained around 80~90% without any troubles and then tremendous reduction of HAA and THM reactivity were observed more than 52%. The average removal rate of HAA formation potential (FP) and THM formation potential (FP) were 70.5% and 67.6% respectively. It is clear that the PAC membrane bioreactor is highly applicable for advanced water treatment to control DBPs.

하수처리장 유입수의 특성평가를 위한 실시간 수질예측 (Real-time Water Quality Prediction for Evaluation of Influent Characteristics in a Full-scale Sewerage Treatment Plant)

  • 김연권;채수권;한인선;김주환
    • 환경영향평가
    • /
    • 제19권6호
    • /
    • pp.617-623
    • /
    • 2010
  • It is the most important subject to figure out characteristics of the wastewater inflows of sewerage treatment plant(STP) when situation models are applied to operation of the biological processes and in the automatic control based on ICA(Instrument, Control and Automation). For the purposes, real-time influent monitoring method has been applied by using on-line monitoring equipments for the process optimization in conventional STP. Since, the influent of STP is consist of complex components such as, COD, BOD, TN, $NH_4$-N, $NO_3$-N, TP and $PO_4$-P. MRA2(Microbial Respiration Analyzer 2), which is capable of real-time analyzing of wastewater characteristics is used to overcome the limitations and defects of conventional online monitoring equipments in this study. Rapidity, accuracy and stability of developed MRA2 are evaluated and compared with the results from on-line monitoring equipments for seven months after installation in Full-scale STP.

Development of Water Treatment Device By Fluidization Electrolysis Using Granular Ceramics

  • Ishikawa, Katsumi;Tamura, Rokurou;Shuto, Rika;Miyawaki, Jinuchi;Tanabe, Kimiko
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.737-745
    • /
    • 1996
  • In recent years, with the increase in the consumption of natural resources and energy, global environmental problems have appeared. This is a very serious environmental load on worldwide food production. For this reason, innovative techniques for production of low entropy by using effectively the energy for the ecosystemic agriculture have been expected. In this study, granular ceramics of 2 to 3mm in diameter having electrical charges at the surface were produced, using the natural raw materials of silicate minerals haing excellent moldabilities and sintering properties . Production of water having functions was attempted by effective use of the electrochemical energy of the ceramics with an efficient water treatment apparatus in which the ceramics were fluidized in water, differently from conventional systems. In the experimental results, the EC of water treated with the ceramics was not changed, but the ORP and also the pH and the DO were changed. The speed of oxidation -re uction reaction was high, and the ceramics -treated water enhanced the vigor of seeds. It can be expected that this treatment system, by which the ORP of water can be moderately controlled, is advantageous in controlling the growth of plants.

  • PDF