• 제목/요약/키워드: conventional procedure

검색결과 1,560건 처리시간 0.042초

Primary peritoneal drainage as a treatment for perforated necrotizing enterocolitis with bacterial peritonitis in an extremely low birth weight infant:a case report (세균성 복막염이 동반된 천공성 괴사성 장염을 일차적 복강 배액술로 완치한 초극소 저출생 체중아 1례)

  • Choi, Wook Sun;Moon, Il Hong;Lee, Jang Hoon;Lee, Seung Hwa;Choi, Byung Min;Eun, Baik-Lin;Hong, Young Sook;Lee, Joo Won
    • Clinical and Experimental Pediatrics
    • /
    • 제49권7호
    • /
    • pp.800-804
    • /
    • 2006
  • Necrotizing enterocolitis(NEC) is the most common life-threatening surgical emergency in neonates, and remains a major cause of morbidity and mortality. In addition to conventional laparotomy, intraperitoneal drains have been used for the treatment of perforated NEC, especially in extremely low birth weight(ELBW) infants. We report a case of perforated NEC with bacterial peritonitis in an ELBW infant managed with primary peritoneal drainage(PD) without further need for surgery. To our knowledge, this is the first documented Korean case of an ELBW infant where PD was used as primary treatment for perforated NEC. Primary PD is effective and safe in ELBW infants with perforated NEC; although it is not considered a definitive procedure, it should be considered in all cases where infants are too unstable to tolerate anesthesia and surgery.

Design and Configuration of 200kW Organic Rankine Cycle Turbine (200kW ORC 터빈 개발 및 구성)

  • Han, Sangjo;Seo, JongBeom
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제38권12호
    • /
    • pp.1057-1064
    • /
    • 2014
  • Recently, there has been a growing interest in sustainable energy. One method that has been used is an organic Rankine cycle using conventional turbine technology with a low-temperature waste heat source. A 200-kW organic Rankine cycle (ORC) system was designed for a waste heat recovery application using R245fa as the working fluid. A radial turbine running at 15,000 rpm was employed to generate more than 200 kW with an expansion ratio of nine. Because an ORC turbine uses a refrigerant as the working fluid, the ideal gas law was not employed to design the turbine. In addition, the complexity of the molecular structure of R245fa made it difficult to design the turbine. Because R245fa has an Ma value of one at a low velocity for the working fluid (about 1/3 of the speed of sound in air) at about $100^{\circ}C$, it easily reaches a supersonic flow condition with a small pressure expansion. To increase the efficiency of the turbine, a dual stage radial-type turbine with a subsonic speed was suggested. This paper will describe the design procedure and performance evaluation of the ORC turbine using R245fa.

LiDAR Chip for Automated Geo-referencing of High-Resolution Satellite Imagery (라이다 칩을 이용한 고해상도 위성영상의 자동좌표등록)

  • Lee, Chang No;Oh, Jae Hong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • 제32권4_1호
    • /
    • pp.319-326
    • /
    • 2014
  • The accurate geo-referencing processes that apply ground control points is prerequisite for effective end use of HRSI (High-resolution satellite imagery). Since the conventional control point acquisition by human operator takes long time, demands for the automated matching to existing reference data has been increasing its popularity. Among many options of reference data, the airborne LiDAR (Light Detection And Ranging) data shows high potential due to its high spatial resolution and vertical accuracy. Additionally, it is in the form of 3-dimensional point cloud free from the relief displacement. Recently, a new matching method between LiDAR data and HRSI was proposed that is based on the image projection of whole LiDAR data into HRSI domain, however, importing and processing the large amount of LiDAR data considered as time-consuming. Therefore, we wmotivated to ere propose a local LiDAR chip generation for the HRSI geo-referencing. In the procedure, a LiDAR point cloud was rasterized into an ortho image with the digital elevation model. After then, we selected local areas, which of containing meaningful amount of edge information to create LiDAR chips of small data size. We tested the LiDAR chips for fully-automated geo-referencing with Kompsat-2 and Kompsat-3 data. Finally, the experimental results showed one-pixel level of mean accuracy.

Clinical and Radiological Outcomes of Foraminal Decompression Using Unilateral Biportal Endoscopic Spine Surgery for Lumbar Foraminal Stenosis

  • Kim, Ju-Eun;Choi, Dae-Jung;Park, Eugene J.
    • Clinics in Orthopedic Surgery
    • /
    • 제10권4호
    • /
    • pp.439-447
    • /
    • 2018
  • Background: Since open Wiltse approach allows limited visualization for foraminal stenosis leading to an incomplete decompression, we report the short-term clinical and radiological results of unilateral biportal endoscopic foraminal decompression using $0^{\circ}$ or $30^{\circ}$ endoscopy with better visualization. Methods: We examined 31 patients that underwent surgery for neurological symptoms due to lumbar foraminal stenosis which was refractory to 6 weeks of conservative treatment. All 31 patients underwent unilateral biportal endoscopic far-lateral decompression (UBEFLD). One portal was used for viewing purpose, and the other was for surgical instruments. Unilateral foraminotomy was performed under guidance of $0^{\circ}$ or $30^{\circ}$ endoscopy. Clinical outcomes were analyzed using the modified Macnab criteria, Oswestry disability index, and visual analogue scale. Plain radiographs obtained preoperatively and 1 year postoperatively were compared to analyze the intervertebral angle (IVA), dynamic IVA, percentage of slip, dynamic percentage of slip (gap between the percentage of slip on flexion and extension views), slip angle, disc height index (DHI), and foraminal height index (FHI). Results: The IVA significantly increased from $6.24^{\circ}{\pm}4.27^{\circ}$ to $6.96^{\circ}{\pm}3.58^{\circ}$ at 1 year postoperatively (p = 0.306). The dynamic IVA slightly decreased from $6.27^{\circ}{\pm}3.12^{\circ}$ to $6.04^{\circ}{\pm}2.41^{\circ}$, but the difference was not statistically significant (p = 0.375). The percentage of slip was $3.41%{\pm}5.24%$ preoperatively and $6.01%{\pm}1.43%$ at 1-year follow-up (p = 0.227), showing no significant difference. The preoperative dynamic percentage of slip was $2.90%{\pm}3.37%$; at 1 year postoperatively, it was $3.13%{\pm}4.11%$ (p = 0.720), showing no significant difference. The DHI changed from $34.78%{\pm}9.54%$ preoperatively to $35.05%{\pm}8.83%$ postoperatively, which was not statistically significant (p = 0.837). In addition, the FHI slightly decreased from $55.15%{\pm}9.45%$ preoperatively to $54.56%{\pm}9.86%$ postoperatively, but the results were not statistically significant (p = 0.705). Conclusions: UBEFLD using endoscopy showed a satisfactory clinical outcome after 1-year follow-up and did not induce postoperative segmental spinal instability. It could be a feasible alternative to conventional open decompression or fusion surgery for lumbar foraminal stenosis.

Clinical Practice Guideline for acupuncture in Post-stroke urinary incontinence (뇌졸중 후 요실금에 대한 침치료 임상진료지침)

  • Lee, Ji-Won;Shin, Byung-Cheul;Lee, Myeong-Soo;Lim, Sung-Min;Yoo, Jung-Hee;Cho, Chung-Sik;Moon, Sang-Kwan;Yook, Tae-Han;Joo, Jong-Cheon;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • 제29권4호
    • /
    • pp.317-325
    • /
    • 2017
  • Objectives This study is aimed to develop a Clinical Practice Guideline (CPG) on acupuncture treatment for the stroke patients with Post-stroke Urinary Incontinence(PSUI). Methods Experts committee, consisting of stroke or methodology specialists, searched Medline, EMBASE, Cochrane Library, China National Knowledge Infrastructure, and 19 Korean medicine journals. The search terms were selected to screen the randomized controlled trials (RCTs) or systematic reviews for the effectiveness of acupuncture on PSUI, compared with placebo or conventional group. Levels of evidence and grades of recommendations were appraised based on Recommendations for Development of Clinical Practice Guideline in Korean Medicine. Results & Conclusions 8 RCT were included to build the CPG. There was a strong evidence to support the effectiveness of acupuncture treatment for PSUI. The moderate evidence was presented that over 3 times a week of the acupuncture should be performed over 4 weeks on the acupoints, such as BL23, CV3, SP6, CV4, CV6, ST28, BL28, BL32, GV20, BL22, GV4 or ST36, for 15-30 minutes. 1-150 Hz frequency is suggested if electro-acupuncture treatments is performed with. It was also suggested that the procedure should begin at the acute stage just after the vital signs of the patients are stabilized. There was a moderate evidence to support safety of acupuncture treatment for PSUI. We recommend acu-points of constitutional acupuncture for Sasangin on the healthy side.

Using 3-dimensional digital smile design in esthetic restoration of anterior teeth: A case report (3차원 Digital Smile Design을 활용한 전치부 심미수복 증례)

  • Hong, Sungman;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제59권4호
    • /
    • pp.451-458
    • /
    • 2021
  • Currently, digital technology is being used in various fields of dental treatment. In particular, in the case of anterior esthetic restoration, the traditional restoration method cannot contain facial information and it is difficult for the patient to predict the treatment result. However, in the case of esthetic restoration through digital design, the visualization of the prosthesis design and the ease of reflecting patient feedback, and expecting the treatment result is available. In this case, the patient confirmed the results of restoration treatment using a digital method before treatment and obtained consent for treatment in an anterior tooth trauma patient. In addition, since the conventional digital smile design method uses only the patient's facial and smile information, the design was made on a two-dimensional plane, and its application was somewhat limited. However, in this case, a three-dimensional virtual patient was created and thus the designed restoration was viewed from various angles. Through this case, it was possible to obtain a high degree of satisfaction with the ease of communication with the patient and the technician during the esthetic restoration using the digital method, the simplicity of the procedure, and the treatment result.

Analysis of interest in implant using a big data: A web-based study (빅 데이터를 이용한 임플란트에 대한 관심도 분석: 웹 기반 연구)

  • Kong, Hyun-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제59권2호
    • /
    • pp.164-172
    • /
    • 2021
  • Purpose: The purpose of this study was to analyze the level of interest that common Internet users have in dental implant using a Google Trends, and to compare the level of interest with big data from National Health Insurance Service. Materials and methods: Google Trends provides a relative search volume for search keywords, which is the average data that visualizes the frequency of searches for those keywords over a specific period of time. Implant was selected as the search keyword to evaluate changes in time flows of general Internet users' interest from 2015 to 2019 with trend line and 6 month moving average. Relative search volume for implant was analyzed with the number of patients who received National Health Insurance coverage for implant. Interest in implant and conventional denture was compared and popular related search keywords were analyzed. Results: Relative search volume for implant has increased gradually and showed a significant positive correlation with the total number of patients (P<.01). Interest in implant was higher than denture for most of the time. Keywords related to implant cost were most frequently observed in all years and related search on implant procedure was increasing. Conclusion: Within the limitations of this study, the public interest in dental implant was gradually increasing and specific areas of interest were changing. Web-based Google Trends data was also compared with traditional data and significant correlation was confirmed.

No-Touch Radiofrequency Ablation of VX2 Hepatic Tumors In Vivo in Rabbits: A Proof of Concept Study

  • Kim, Tae-Hyung;Choi, Hyoung In;Kim, Bo Ram;Kang, Ji Hee;Nam, Ju Gang;Park, Sae Jin;Lee, Seunghyun;Yoon, Jeong Hee;Lee, Dong Ho;Joo, Ijin;Lee, Jeong Min
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1099-1109
    • /
    • 2018
  • Objective: In a proof of concept study, we compared no-touch radiofrequency ablation (NtRFA) in bipolar mode with conventional direct tumor puncture (DTP) in terms of local tumor control (LTC), peritoneal seeding, and tumorigenic factors, in the rabbit VX2 subcapsular hepatic tumor model. Materials and Methods: Sixty-two rabbits with VX2 subcapsular hepatic tumors were divided into three groups according to the procedure: DTP-RFA (n = 25); NtRFA (n = 25); and control (n = 12). Each of the three groups was subdivided into two sets for pathologic analysis (n = 24) or computed tomography (CT) follow-up for 6 weeks after RFA (n = 38). Ultrasonography-guided DTP-RFA and NtRFA were performed nine days after tumor implantation. LTC was defined by either achievement of complete tumor necrosis on histopathology or absence of local tumor progression on follow-up CT and autopsy. Development of peritoneal seeding was also compared among the groups. Serum hepatocyte growth factor (HGF), vascular endothelial growth factor (VEGF) and interleukin-6 (IL-6) were measured via ELISA (Elabscience Biotechnology Co.) after RFA for tumorigenic factor evaluation. Results: Regarding LTC, there was a trend in NtRFA (80%, 20/25) toward better ablation than in DTP-RFA (56%, 14/25) (p = 0.069). Complete tumor necrosis was achieved in 54.5% of DTP-RFA (6/11) and 90.9% of NtRFA (10/11). Peritoneal seeding was significantly more common in DTP-RFA (71.4%, 10/14) than in NtRFA (21.4%, 3/14) (p = 0.021) or control (0%). Elevations of HGF, VEGF or IL-6 were not detected in any group. Conclusion: No-touch radiofrequency ablation led to lower rates of peritoneal seeding and showed a tendency toward better LTC than DTP-RFA.

Computer-Assisted Navigation in Total Knee Arthroplasty (내비게이션 장치를 이용한 슬관절 전치환술)

  • Jeong, Hwa-Jae;Park, Yong-Beom;Lee, Han-Jun
    • Journal of the Korean Orthopaedic Association
    • /
    • 제53권6호
    • /
    • pp.478-489
    • /
    • 2018
  • Total knee arthroplasty has become a standard procedure for advanced knee arthritis to relieve pain and improve function. Computer-assisted navigation systems have been used in total knee arthroplasty to improve the mechanical axis of the limb as well as the alignment and position of the components. A computer-assisted navigation system has the advantage of real-time feedback during surgery, such as mediolateral balance in extension and flexion gap, alignment of the lower limb, and components. On the other hand, the computer-assisted navigation system requires an additional stab wound for tracker fixation, which can increase the likelihood of superficial wound infection and stress fractures and increase the operation time and cost of surgery. The clinical efficacy of computer-assisted navigation in total knee arthroplasty is also controversial. Compared to the conventional technique, computer navigation improves the accuracy of the postoperative mechanical axis within outliers of $3^{\circ}$ varus or $3^{\circ}$ valgus. This paper reviews the surgical technique, pitfalls, clinical and radiological outcomes, useful clinical cases, and future perspectives in computer-assisted navigation total knee arthroplasty.

Full mouth rehabilitation of patient with severe dental caries with implant fixed prosthesis fabricated with milling and 3D printing method: A case report (밀링 및 3D 프린팅 방법으로 제작된 임플란트 보철물을 이용한 심한 우식 환자의 완전 구강 회복 증례)

  • Kim, Taeyoon;Lee, Jun-Suk;Hong, Seoung-Jin;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제57권3호
    • /
    • pp.288-295
    • /
    • 2019
  • Passive fit of prosthesis is an essential property of implant supported prosthesis for long term success and minimization of complications. And the property is determined mostly by fabrication procedure. There were limitations of extensive implant prosthesis because conventional casting method generate contraction error of long span prosthesis. However, Computer-aided design/Computer-aided manufacturing (CAD/CAM) technology of 3D printing and milling metal framework can overcome those limitations. This case is a full mouth rehabilitation using extensive implant fixed prosthesis. Removable interim prosthesis was made for esthetic, functional evaluation and a guide for implant insertion. After the insertion, implant fixed interim prosthesis was delivered. After additional evaluation and adjustment, final prosthesis was designed with CAD, the fabricated with CAM. Milling technique was used for anterior screw type implant superstructure and 3D printing technique was used for the anterior and posterior implant copings. Fit of the final restoration was favorable. The practitioner and patient were both esthetically and functionally satisfied with the final result.