• 제목/요약/키워드: convection tube

검색결과 169건 처리시간 0.022초

Temperature Dependent Self-Diffusion Coefficients of Valinomycin and the Potassium-Valinomycin Complex

  • Kim, Su-Deuk;Lee, Yun-Jung;Joo, Hyun-Hye;Ahn, Sang-Doo
    • 한국자기공명학회논문지
    • /
    • 제12권1호
    • /
    • pp.51-59
    • /
    • 2008
  • Convection effect in liquids has been one of the main targets to be overcome in pulsed-field-gradient NMR measurements of self-diffusion coefficients since the temperature gradient along the sample tube generated by the heating and/or cooling process causes the effect, resulting in additional diffusion. It is known that the capillary is the most appropriate tube type for diffusion experiments at variable temperatures since the narrower tube suppresses convection effectively. For evaluating the properties of hydrogen bonding, diffusion coefficients of the $K^+$-complexed and free valinomycin in a micro tube have been determined at various temperatures. From the analysis of the obtained diffusion coefficient values, we could conclude that the intramolecular hydrogen bonding in both of the $K^+$ complexed and free valinomycin in a non-polar solvent is preserved over the observed temperature range, and the temperature dependence of hydrogen bonding is more pronounced in free valinomycin. It is also thought that there is no big change in the radius of the $K^+$-complexed as temperature is varied, and the ratio of overall radius, $r_{complex}/r_{free}$ is slightly decreased as temperature rises.

격판을 가진 수평환상공간에서의 자연대류 열전달 (Natural Convection Heat Transfer from a Horizontal Annulus with Spacers)

  • 이범철;정한식;권순석
    • 대한기계학회논문집
    • /
    • 제13권1호
    • /
    • pp.153-160
    • /
    • 1989
  • 본 연구는 수평전도관과 수평원통 사이의 환상공간에 수직격판이 부착된 경우와 수평직판이 부착된 경우에 Rayleigh수와 무차원 관열전도율을 변수로하여 수직해석과 Mach-Mehnder 간섭계를 이용한 실험으로 자연대류 열전달특성을 연구 하였다.

휜이 부착된 수직(垂直) 냉각관(冷却管)에서의 열전달(熱傳達)에 관(關)한 실험적(實驗的)인 연구(硏究) (An experimental study on heat transfer of finned vertical cooling tube)

  • 송하진;이채문;임장순
    • 태양에너지
    • /
    • 제4권2호
    • /
    • pp.43-49
    • /
    • 1984
  • Experiments were performed to study freezing on a finned vertical tube when either conduction in the solid or natural convection in a liquid controls the heat transfer. Conduction is the controlling mode when the liquid is at its fusion temperature, whereas natural convection controls when the liquid temperature is above the fusion value. The liquid was housed in a cylinderical containment vessel whose surface was maintained at a uniform, time-invariment temperature during a data run, and the freezing occurred on a finned vertical tube positioned along the axis of the vessel. The phase change medium was n-octacosan, a paraffin which freezes at about $61^{\circ}C$. For conduction-controlled freezing, the enhancement of the frozen mass due to finning is greatest when the frozen layer is thin and decrease as the layer grows thicker. The degree of enhancement is generally less than the surface area ratio of the finned and unfinned tube.

  • PDF

단일수직(單一垂直)한 축방향(軸方向)의 핀을 가진 수평전도관(水平傳導管)으로 부터의 자연대류(自然對流) (Natural Convection from a Horisontal Conducting Tube with One Vertical Axial Fin.)

  • 정한식;권순석
    • 태양에너지
    • /
    • 제6권1호
    • /
    • pp.60-69
    • /
    • 1986
  • Two-dimensional finite difference numerical analysis is used to study conjugate natural convection heat transfer from a horizontal conducting tube with one vertical axial fin. By increasing dimensionless fin length ($L_F$), the mean total Nusselt number of the upward fin is slightly less than that of the downward fin at $L_F\;{\le}\;0.18$ and is higher than that of the downward fin at $L_F\;>\;0.18$. However comparing the upward fin and the downward fin with the no fin, the mean total Nusselt numbers of downward fin and upward fin at $L_F=0.30$ are increased approximately 4.01% and 5.51%, respectively. As Rayleigh number, Prandtl number and Biot number increase, the mean total and the mean tube Nusselt numbers are increased, but as wall thickness increases, the mean total and the mean tube Nusselt numbers are decreased. As the fin conduction parameter increases, the mean total Nusselt number is slightly increased because of increasing the mean fin Nusselt number.

  • PDF

수평 원관의 비등 열전달에서 강제대류의 영향 (The effect of forced convection on boiling heat transfer from a horizontal tube)

  • 이승홍;이억수;정은행
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.558-568
    • /
    • 1998
  • This paper presents the results of experiments involving external forced convection on boiling heat transfer from electrically heated horizontal tube to water in cross flow. In these experiments, all of the following primary variables were varied: heat flux, cross flow velocity, pressure and degree of subcooling. Local surface temperatures were measured at nine peripheral positions. Surface temperature distributions are classified into four groups as a function of heat flux. The characteristics of the boiling curve at different velocity, degree of subcooling and pressure are examined.

  • PDF

단일 원형관-원형휜 열교환기의 자연대류 열전달 실험관계식 (Free Convection Correlation for the Single Circular Finned Tube Heat Exchanger)

  • 강희찬;장현순
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.596-600
    • /
    • 2008
  • An experimental study has been conducted on the free convection heat transfer for the 7 kinds of circular finned tube heat exchangers. Empirical correlation was suggested at the range of 3,500$D_o$/$D_i$<3.0, 0.19<$P_f$/$D_i$<0.34. The 92% of experimental data agreed with the correlation within 10%.

  • PDF

Heat Transfer Performance of Various Tubes for an Air-cooled Absorber with Surfactant

  • Yoon, Jung-In;Kim, Eun-Pil;Moon, Choon-Geun;Kwon, Oh-Kyong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.1-10
    • /
    • 2000
  • This research is concerned with the enhancement of heat transfer by surfactant added to the aqueous solution of LiBr. Different vertical tubes were tested with and without an additive of normal octyl alcohol. The test tubes are a bare tube, a groove tube, a corrugated tube and a spring-inserted tube. The additive concentration is about 0.08 mass%. The heat transfer coefficient is measured as a function of the film Reynolds number in the range of 20~200. Experiments are carried out at higher cooling water temperature of $35^{\circ}C$to simulate an air cooling condition for several kinds of absorber testing tubes. The experimental results with and without surfactant are compared. The enhancement of heat transfer by Marangoni convection effect which is generated by addition of the surfactant is observed in each test tube. Especially, it is clarified that the tube with an spring-inserted has the enhancement effect.

  • PDF

보온터널 난방을 위한 온수난방용 코일튜브 열교환기의 열전달 특성 (Heat Transfer Characteristics of Coil Tube Heat Exchanger for Hot Water Heating of Greenhouse Thermal Tunnel)

  • 유영선;강금춘;김영중;백이;강연구;이형모
    • Journal of Biosystems Engineering
    • /
    • 제31권5호
    • /
    • pp.430-435
    • /
    • 2006
  • Greenhouse horticulture in South Korea covered about 52,000 ha in 2005. Greenhouse area of about 12,000 ha has been heated during winter season with heating cost of $20{\sim}40%$ of total Production cost. Farmers engaged in greenhouse horticulture were changed into aged people. Therefore the laborsaving of working process and the saving of greenhouse heating cost should be accomplished simultaneously to increase income of greenhouse horticulture. The best method for saving of greenhouse heating cost is to install thermal tunnels into greenhouse. Then hot air heaters using fossil fuel should be changed into hot water heaters. In other words air heating using forced convection should be changed into natural convection system. In this research coil tube made of flexible PE pipe was designed as hot water heat exchanger and its heat exchanging characteristics were analyzed. This new heat exchanger has been adopted as a natural convection system for hot water heating of greenhouse horticulture.

보일러용 裸管 및 리브붙이管 의 熱傳達 特性 에 관한 硏究 (A Study on Heat Trasfer Characteristics of Smooth and Ribbed Tubes for Boiler)

  • 김종보;한승탁
    • 대한기계학회논문집
    • /
    • 제9권6호
    • /
    • pp.699-705
    • /
    • 1985
  • 본 논문에서는 자연 및 강제순환 모두를 실험 했으며 사용한 리브붙이 관은 관의 두께와 직경, 리브수, 리브 피치(Pitch), 높이 및 폭등을 사용 하려는 열교환기 나 보일러에 합당하도록 설계, 선정하면, 그 적용 범위는 매우 넓다고 생각돼 연구 검 토 하고자 한다.

An Investigation of the Sample Rotation Effects on Suppression of Convective Flows in PGSE Diffusion NMR Experiments

  • Kim, Minkyoung;Chung, Kee-Choo
    • 한국자기공명학회논문지
    • /
    • 제20권2호
    • /
    • pp.61-65
    • /
    • 2016
  • Undesirable convective flow in an NMR tube inhibits the accurate measurement of diffusion coefficients by NMR spectroscopy. To minimize the convection effects, various methods have been suggested, and it has been known that the use of sample rotation can be useful. However, it has not been clearly examined that the convection suppressing effect of the sample rotation under the different spinning speeds. In this study, the relation between convective flow and the sample rotation was investigated using PGSE NMR diffusion experiments to reveal the feasibility for controlling the convective flow in an NMR tube by sample rotation itself. The viscosity effect was also examined using solvents with four different viscosities, acetone-$d_6$ chloroform-d, pyridine-$d_5$, and $D_2O$. The sample rotation showed apparent convection suppressing effects at all temperature range for the low viscosity solvents, acetone-$d_6$ and chloroform-d, even at the faster than 5 Hz spinning rate. The similar patterns were also observed for pyridine-$d_5$ and $D_2O$, which have higher viscosity. This effect was observed even at high temperatures where convective flow arises conspicuously.