• 제목/요약/키워드: controlled temperature-humidity system

Search Result 109, Processing Time 0.021 seconds

유비쿼터스 센서 네트워크 기반의 생활환경 자동제어 시스템 설계 및 구현 (The Design and Implementation of Automatic Control System of Living Environment Based on Ubiquitous Sensor Network)

  • 윤지훈;문승진
    • 제어로봇시스템학회논문지
    • /
    • 제14권1호
    • /
    • pp.1-6
    • /
    • 2008
  • The ubiquitous sensor network technique is widely applied to variety of information fields such as home automations, logistics, traffic controls, public administrations, health and environment monitoring and etc. It is particularly useful in the areas where energy consumption is minimal and where continuous monitoring of the surrounding environments, which generates streams of data, are required. In this study, we have designed and implemented a living environment automatic control system which collects the streams of temperature, humidity, light and noise data of a simulated house setting in real-time fashion, then controls the home environment based on the collected data according to the users favorites. In order to differentiate the proposed system from the currently existing similar system, we have demonstrated not only the feasibility of collecting data using sensor network in the controlled environment but also the ability to control the various household equipments through wireless communications.

Study on the Performances of Air Flow Fate Effect on a Structured Packed Tower at Adiabatic Condition in a Liquid Lithium Chloride Cooling System

  • Bakhtiar, Agung;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.404-408
    • /
    • 2009
  • The liquid desiccant air-conditioning system has been proposed as an alternative to the conventional vapor compression cooling systems to control air humidity. The complete system of liquid desiccant air-conditioning system is consisted two main components those are humidifier (regeneration) and dehumidifier. Humidifier part is connected to the load when summer season which is the air condition is hot and humid have to be turned into comfort condition on human. This paper purpose is performances study of air flow rate effect on a structured packed tower on cooling and dehumidifier system using liquid lithium chloride as the desiccant. Experimental apparatus used in this present study is consisted of three components those are load chamber, packed tower and chiller. Load chamber’s volume is $40m^3$, and packed tower dimension is cubic with length 0.4m occupied with packed column. Totally, 15 experimental has done using 5 times repeat on each variable of air velocity that varying on 2m/s, 3m/s and 4m/s with other conditions are controlled. Air inlet initial temperature and relative humidity are set respectively on $30^{\circ}C$ and 52%, desiccant flow rate is 0.63 kg/s, desiccant temperature is $10^{\circ}C$ and desiccant concentration is 0.4. The result of this study shows that averagely, the moisture removal rate and the heat transfer rate are influenced by the air velocity. Higher air velocity will increase the heat transfer and decreasing the moisture removal rate. At adiabatic condition the air velocity of 2 m/s respectively is having the higher moisture removal rate acceleration then the air velocity of 3m/s and 4 m/s until the steady state condition.

  • PDF

에너지 절감용 조명 및 공조기기 최적제어 시스템 개발 (Development of Optimal Control System for Lighting and HVAC(Heating, Ventilation, Air Conditioning) Using Energy Saving)

  • 장우성;송영석;조병록;조석환
    • 한국전자통신학회논문지
    • /
    • 제13권5호
    • /
    • pp.1029-1036
    • /
    • 2018
  • 본 논문은 캠퍼스환경에서 에너지 절약을 위해 조명 및 공조기기의 최적제어 시스템 개발에 대한 연구이다. 본 연구를 통해 개발 된 제어 시스템의 경우 모션센서와 영상처리를 통해 출입 인원수 파악과 온/습도에 대한 정보로 조명과 에어컨을 제어한다. 또한 데이터 통합 모니터링과 제어 신호에 따른 명령 수행 기능을 통해 제어한 결과들로 에너지 절약을 가능하도록 하였다.

다중 채널 데이터 수집장치 구성에 관한 연구 (A Study on the Design of Multi Channel Data Acquisition System)

  • 권용무;김홍석;김형곤;오명환
    • 대한전기학회논문지
    • /
    • 제35권6호
    • /
    • pp.209-216
    • /
    • 1986
  • This paper describes the design of multi channel data acquisiton system for industrial process automation. The prototype hardware assembly consists of Z-80A microprocessor, 10-bit A/D converter with 16-channel analog multiplexor and related interface circuitry. The first order lag filter, which can be implemented without any particular computational problem has implemented in software, and the simulation results are shown. The protype system can communicate with a central processor through RS-232C, and can be used either as an intelligent stand-alone controller or as a satellite controller which can be monitored and controlled by a central processor. The singal conditioners for various temperature and humidity sensors are designed and experimental results are shown.

  • PDF

도서관자료(圖書館資料) 보존(保存)에 관한 연구(硏究) (A Study on the Conservation of Library Materials)

  • 권기원
    • 한국비블리아학회지
    • /
    • 제6권1호
    • /
    • pp.179-213
    • /
    • 1984
  • The history of recording and conserving for maintenance the human's memory from ancient times to modern's has brought about a lot of changing process of the recorded information media with developing in culture, and each society has made important recorded materials in his library as essentially the social apparatus. But most of them that were damaged by factors of the natural disaster, humidity, temperature, light, fungi and insects in the library, and were resulted in deterioration and losing the numerous materials. For removing the inevitable phases repeated, there are studying for counterplan of the fundamental environment factors about preservation, restoration and chemical research of materials in advanced countries, but I get a few researches about protecting the cultural properties. Therefore I research the survey of the actual conditions on 72 university libraries centering around them, and then I have researched the collection rate 81 percent, 58 university libraries. (local : 35, in seoul : 23) As the result of this research, I propose the model of the environment factors of conserving the library materials. 1) To apply the equipment of processing the radiant energy to the new construction and buildings. 2) To remove factors that occur fungi and insects by facilities being controlled relative humility, temperature, and to equip the ventilation arrangement in the library. 3) To shelve all acquired and bound materials after proceeding the vacuum fumigator. 4) Those who want to enter into the library stack were surely taken in sterilzing their hands and shoes, and must put on the gown. 5) To use the vacuum dusting thing (machine) for removing the dust without spreading out the floor of the library at any time. 6) To set up the gas automatic fire extinguisher worked by smoke sensor. 7) To assist the research into the preservation, natures and environment of recorded materials, and to supply financial funds for librarian. 8) To hold regularly the workshop be able to educate the methods of preservation materials by the constant system. (Library Association) 9) To add to responsibilities on certification of preservation materials for librarian. 10) To hold the constant committee system in each library. 11) To keep up with the ideal environment (humidity, temperature, light, ventilation, etc.) of preservation materials in the arrangement room, and to put on the gown.

  • PDF

태양열 이용 냉난방 공조시스템 중 전열교환기의 최적운전조건에 관한 연구 (Research on the Optimal Operating Condition of a Total Heat Exchanger in Solar Air-Conditioning System)

  • 김광호;최광환;금종수;김보철;김동규
    • 태양에너지
    • /
    • 제19권4호
    • /
    • pp.55-62
    • /
    • 1999
  • This study was performed to find out the influence of experimental factors on dehumidification performance and furthermore to suggest an optimal combination of factors of a total heat exchanger in a solar air conditioning system. The experimental apparatus was set up in a climate-controlled chamber where the temperature and humidity was maintained constant. In order to find out the contribution ratio of factors on dehumidification performance, the table of orthogonal arrays $L_8(2^7)$ was used. According to the results, the most influential factor on dehumidification performance was the concentration of LiCl(Lithium Chloride) solution. The next influential factors were the temperature of LiCl solution and the air flow rate. The packed layer height, packed material, and flow rate of LiCl solution had no influence on the dehumidification performance under these experimental conditions. Through the three level experiments of $L_{27}(3^{13})$, it was found that the optimal combination was $A_2B_0G_2$(concentration of solution 30 wt%, temperature of solution $15^{\circ}C$, air flow rate $253m^3/h$).

  • PDF

Implementation of a Sightseeing Multi-function Controller Using Neural Networks

  • Jae-Kyung, Lee;Jae-Hong, Yim
    • Journal of information and communication convergence engineering
    • /
    • 제21권1호
    • /
    • pp.45-53
    • /
    • 2023
  • This study constructs various scenarios required for landscape lighting; furthermore, a large-capacity general-purpose multifunctional controller is designed and implemented to validate the operation of the various scenarios. The multi-functional controller is a large-capacity general-purpose controller composed of a drive and control unit that controls the scenarios and colors of LED modules and an LED display unit. In addition, we conduct a computer simulation by designing a control system to represent the most appropriate color according to the input values of the temperature, illuminance, and humidity, using the neuro-control system. Consequently, when examining the result and output color according to neuro-control, unlike existing crisp logic, neuro-control does not require the storage of many data inputs because of the characteristics of artificial intelligence; the desired value can be controlled by learning with learning data.

태양열 이용 냉난방 공조시스템의 재생성능에 영향을 미치는 인자의 기여율에 관한 연구 (Study on the Contribution Ratio of Factors to Affect Regeneration Performance of a Solar Air Conditioning System)

  • 김보철;최광환;금종수
    • 태양에너지
    • /
    • 제20권1호
    • /
    • pp.91-96
    • /
    • 2000
  • This study was performed to find out how much experimental factors influence on regeneration performance in a solar air conditioning system. The experimental apparatus was set up in a climate-controlled chamber where temperature and humidity could be kept constant. In order. to investigate factors' influence on the regeneration performance of the solar air conditioning system, the model experiment was done using the 600mm $\times$ 600mm black painted aluminum regenerator. The design and analysis of experiment were done by the design of experiments, especially the table of orthogonal arrays. In order to find out how much experimental factors influence on regeneration performance, the table of orthogonal arrays $L_8(2^7)$ was used. According to the results, it was found that the most influential factor to affect regeneration performance was the concentration of LiCl solution. The next influential factors were a solar radiation, an air velocity, and the temperature of LiCl solution in order.

  • PDF

인터넷을 이용한 저온저장고 환경감시 및 경보 시스템 개발 (Development of an Environmental Monitoring and Warning System for Cold Storage Rouse Using Internet)

  • 정훈;윤홍선;이원옥;조광환;조영길;박원규;신재훈
    • 한국식품저장유통학회지
    • /
    • 제10권1호
    • /
    • pp.28-31
    • /
    • 2003
  • 농산물의 고품질 유지 저온저장 및 저장물 관리의 편리화를 위해서 원거리에서 저장고 환경을 감시할 수 있는 인터넷을 이용한 저온저장고 환경감시 및 경보 시스템을 개발하였으며, 그 내용을 요약하면 다음과 같다. 실용화를 촉진하기 위하여 환경감시 및 경보 시스템의 저온저장고측 컴퓨터를 산업용 제어반인 PLC(Programmable Logic Controller)로 하여 원거리 환경감시 및 경보시스템을 제작하였다. 농가에서 사용하기 쉽게 윈도우용 환경하에서 작동하는 원거리 환경감시 프로그램을 개발하였으며, 전화선을 통해 수시로 저장환경을 감시할 수 있고, 기기 이상시 전화 및 호출기로 경보하게 하였다. 농업기계화연구소 저장유통기계연구실 홈페이지에 저온저장고 실시간 감시 사이트를 시험용으로 제작하여 인터넷이 가능한 컴퓨터에서 어디서나 저장상황을 감시할 수 있게 하였다. 시스템의 성능시험 결과 저장고내의 온도편차는 기존의 $\pm$1∼2$^{\circ}C$에 비해 $\pm$0.5$^{\circ}C$로 나타났으며, 습도편차는 $\pm$2% 이내로 나타나 정밀한 결과를 보였다. 본 시스템의 작업정밀성, 취급성, 보급필요성 등에 대한 설문조사 결과, 작업정밀성, 취급성 및 보급필요성에 있어서 긍정적인 반응이 많았으며, 농가에서 실용적으로 사용 가능할 것으로 판단된다.

저온저장고의 뉴로-퍼지 제어시스템 개발 (Development of Neuro-Fuzzy System for Cold Storage Facility)

  • 양길모;고학균;홍지향
    • Journal of Biosystems Engineering
    • /
    • 제28권2호
    • /
    • pp.117-126
    • /
    • 2003
  • This study was conducted to develop precision control system fur cold storage facility that could offer safe storage environment for green grocery. For that reason of neuro-fuzzy control system with learning ability algorithm and single chip neuro-fuzzy micro controller was developed for cold storage facility. Dynamic characteristics and hunting of neuro-fuzzy control system were far superior to on-off and fuzzy control system. Dynamic characteristics of temperature were faster than on-off control system by 1,555 seconds(123% faster) and fuzzy control system by 460 seconds(36.4% faster). When system was arrived at steady state. hunting was ${\pm}$0.5$^{\circ}C$ in on-off control system, ${\pm}$0.4$^{\circ}C$ in fuzzy control system, and ${\pm}$0.3$^{\circ}C$ in neuro-fuzzy control system. Hunting of humidity and wind velocity was also controlled precisely by 70 to 72.5% and 1m/s For storage experiment with onion, characteristics of neuro-fuzzy control system were tested. Dynamic characteristics of neuro-fuzzy control system made cold storage facility conducted precooling ability and minimized hunting.