• Title/Summary/Keyword: contrast flow

Search Result 496, Processing Time 0.027 seconds

Coarsening Effects on the Formation of Microporous Membranes

  • Song, Seung-Won
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.04a
    • /
    • pp.1-4
    • /
    • 1995
  • The microstructure of polymer membranes produced via thermally induced phase separation (TIPS) of polymer solutions is a strong function of both the early-stage (by spinodal decomposition or nucleation & growth) and the late-stage phase separation (referred to in general as coarsening). In the case of early stage effects, the membrane morphology resulting from a nucleation & growth mechanism is either a poorly interconnecsed, stringy, beady structure which is mechanically fragile or a well interconnected structure with highly nonuniform pore sizes. In contrast, spinodal decomposition results in a well interconnected, mechanically strong membrane with highly uniform pore sizes. Here I describe recent quantitative studies of the coarsening effects on the microstructure of membranes produced via TIPS process. The dependence of microstructure on coarsening time, quench depth, solution viscosity, and polymer molecular weight was investigated in order to distinguish among three possible coarsening mechanisms, Ostwald ripening, coalescence, and hydrodynamic flow, which may be responsible for structural evolution after the early-stage phase Separation (spinodal decomposition or nucleation & growth).

  • PDF

In Vivo Visualization of Flow in Xylem Vessels of a Bamboo Using X-ray Micro-imaging Technique (X-ray 미세영상기법을 이용한 식물 목질부 내부 수액 유동의 계측)

  • Kim, Yang-Min;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1693-1696
    • /
    • 2004
  • Synchrotron X-ray micro-imaging technique was employed to monitor non-invasively the refilling process of water inside the xylem vessels in bamboo leaves. The consecutive phase-contrast X-ray images clearly show both plant anatomy and the transport of water inside the xylem vessels. Traces of water-rise, vapor bubbles and variations of contact angle between the water front and the xylem wall were measured in real time. During the refilling process, air bubbles are removed when the rising water front halts at a vessel end for a while. Subsequently, it starts rising again at a higher velocity than the normal refilling speed. Repeated cavitation seems to deteriorate the refilling ability in xylem vessels. In dark environment, the water refilling process in xylem vessels is facilitated more effectively than in bright illuminated conditions. Finally, X-ray micro-imaging was famed to be a powerful, high resolution, real time imaging tool to investigate the water refilling process in xylem vessels.

  • PDF

Assessment of the influence of coal combustion model and turbulent mixing rate in CFD of a 500 MWe tangential-firing boiler (500 MWe급 접선 연소 보일러 해석시 난류 혼합 속도 및 석탄 연소 모델의 영향 평가)

  • Yang, Joo-Hyang;Kang, Kie-Seop;Ryu, Changkook
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.69-72
    • /
    • 2015
  • Computational fluid dynamics (CFD) modeling of large-scale coal-fired boilers requires a complicated set of flow, heat transfer and combustion process models based on different degrees of simplification. This study investigates the influence of coal devolatilization, char conversion and turbulent gas reaction models in CFD for a tangential-firing boiler at 500MWe capacity. Devolatilization model is found out not significant on the overall results, when the kinetic rates and the composition of volatiles were varied. In contrast, the turbulence mixing rate influenced significantly on the gas reaction rates, temperature, and heat transfer rate on the wall. The influence of char conversion by the unreacted core shrinking model (UCSM) and the 1st-order global rate model was not significant, but the unburned carbon concentration was predicted in details by the UCSM. Overall, the effects of the selected models were found similar with previous study for a wall-firing boiler.

  • PDF

A Study on the Service Integration of Traditional Chatbot and ChatGPT (전통적인 챗봇과 ChatGPT 연계 서비스 방안 연구)

  • Cheonsu Jeong
    • Journal of Information Technology Applications and Management
    • /
    • v.30 no.4
    • /
    • pp.11-28
    • /
    • 2023
  • This paper proposes a method of integrating ChatGPT with traditional chatbot systems to enhance conversational artificial intelligence(AI) and create more efficient conversational systems. Traditional chatbot systems are primarily based on classification models and are limited to intent classification and simple response generation. In contrast, ChatGPT is a state-of-the-art AI technology for natural language generation, which can generate more natural and fluent conversations. In this paper, we analyze the business service areas that can be integrated with ChatGPT and traditional chatbots, and present methods for conducting conversational scenarios through case studies of service types. Additionally, we suggest ways to integrate ChatGPT with traditional chatbot systems for intent recognition, conversation flow control, and response generation. We provide a practical implementation example of how to integrate ChatGPT with traditional chatbots, making it easier to understand and build integration methods and actively utilize ChatGPT with existing chatbots.

Vascular anatomy and their variations in Situs inversus totalis using postmortem computed tomographic angiography

  • Dawa Zangpo;Hironobu Nakane;Morio Iino
    • Anatomy and Cell Biology
    • /
    • v.56 no.1
    • /
    • pp.155-159
    • /
    • 2023
  • Studies describing the vascular systems and their variations in Situs inversus totalis (SIT) from a whole-body computed tomographic (CT) angiography perspective are lacking. We report a case of SIT in which postmortem CT angiography (PMCTA) was performed as a part of the forensic death investigation and incidentally detected several vascular variations in it. The PMCTA procedure was performed using the multiphase PMCTA protocol. Almost all major vessels were visualized, indeed in a completely reversed pattern. Contrast mixture flow interruptions were noted in the right coronary arterial branches suggesting possible blockage, upon which autopsy revealed >90% vessel occlusions at several locations. As such the cause of death was due to ischemic heart disease. Anomalous origins of the right internal mammary artery; abnormal left thyrocervical trunk and variations in the drainage of testicular veins were noted. Our findings might be helpful to clinicians and add to the body of literature on SIT.

Passive autocatalytic recombiner guide structure considering ambient flow (분위기 유동을 고려한 PAR 가이드 구조에 관한 연구)

  • Ryu, Myeong-Rok;Park, Kweon-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.302-309
    • /
    • 2017
  • If a hydrogen explosion occurs in a containment building, its multiplex defense wall may be destroyed and a large amount of radioactive material may be released. The hydrogen occurred interacting with melting fuel rods must be effectively controlled and removed. however, the countermeasures for reducing explosion risk are difficult to carry out, due owing to the various variety of accident scenarios causes and the irregularity of hydrogen distribution and behavior. In this study, We examine the guide structures while considering the ambient flows, in order to improve the efficiency of PAR the widely used Passive Autocatalytic Recombiner(PAR). We simulate the fluid behavior and the hydrogen reduction rate were simulated when a guide is attached to the two-step catalyst PAR. For an upward flow, the consisting of a height of 150mm, a gap of 0mm, and a performs $60^{\circ}$ showed the best. In contrast, for a sideways flow, a consisting of the height of 150mm, a gap of 100mm, and a performs $60^{\circ}$ showed the best in the case of side ward flow. for a downward flow, a consisting of the height of 50mm and a directly attached guide produce the best in the case of down ward flow results.

Contribution of Bulk Flow to Transport Mechanisms of the Membranes Surrounding Amniotic Fluid in the Rabbit

  • Lim, Young-Cheol;Lee, Sang-Jin;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.28 no.1
    • /
    • pp.79-90
    • /
    • 1994
  • The objective of the present study is to assess the contribution of bulk flow to the regulatory mechanism of amniotic fluid volume and its ionic concentration in the membranes surrounding the amniotic fluid. For quantitative assessment, we prepared 4 kinds of artificial amniotic fIuids (isotonic isovolumetric, hypotonic isovolumetric, isotonic hypervolumetric and hypotonic hypervolumetric ones) by replacing 70% of amniotic fluid of pregnant rabbits with water or normal Tyrode solutions. Isoosmotic saline of 0.5 ml volume containing 0.05% Censored and 15 mM/l LiCl was administered initially into amniotic sacs of all subject animals. Samples of amniotic fluid were collected in after 30 and 90 minute intervals; the concentrations of Censored, $Na^+\;and\;Li^+$ were determined and compared. Followings are the results obtained. 1. from isovolumetric and increased Congcord group, we couldn't find significant change in $Li^+\;and\;Na^+$ concentration in isotonic amniotic fluid. However, $Na^+$ concentration increased significantly as well as a striking increase in Censored concentration in hypotonic amniotic fluid. 2. In isovoIumetric and decreased Censored group, the rate of $[Li^+]$ decrement and the rate of $[Na^+]$ increment were much higher in hypotonic amniotic fluid than in isotonic. 3. In hypervolumetric and increased Censored group, the rate of $Na^+$ efflux increased proportionately with the increment of Censored concentration up to 0.98, which was higher than the rate of $Li^+$ efflux in isotonic amniotic fluid. However, the increment of $Na^+$ concentration was rather related with the initial $Na^+$ concentration in hypotonic amniotic fluid, showing inverse relationship. $Li^+$ concentration increased only when there was a marked increase in Censored concentration and approached near a maximum value or 1. 4. For hypervolumetric and decreased Censored group, the observations were identical to isovolumetric and decreased Censored group. From these results the following conclusions could be made: 1) There is no net movement of water or monovalent cations across the membranes surrounding amniotic fIuid in isotonic isovolumetric condition. In contrast, there is a net efflux of amniotic fluid by osmotic bulk flow, resulting in elevation of $Na^+$ concentration in hypotonic isovolumetric condition. 2) In hypervolumetric conditions, there is a massive efflux of amniotic fluid or solvent drag through the surrounding membranes by fiItrative bulk flow, where the rate of $Na^+$ efflux has a linear relationship with that of water efflux. This is assumed to be carried out through enlarged and newly opened intercellular spaces resulting from increased intraamniotic pressure. 3) Once increasing intraamniotic pressure reaches a point allowing $Li^+$ to pass through during osmotic bulk flow in hypotonic amniotic fIuid, $Na^+$ influx seems to occur by diffusion simultaneously or immediately thereafter, too.

  • PDF

CT Fractional Flow Reserve for the Diagnosis of Myocardial Bridging-Related Ischemia: A Study Using Dynamic CT Myocardial Perfusion Imaging as a Reference Standard

  • Yarong Yu;Lihua Yu;Xu Dai;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.22 no.12
    • /
    • pp.1964-1973
    • /
    • 2021
  • Objective: To investigate the diagnostic performance of CT fractional flow reserve (CT-FFR) for myocardial bridging-related ischemia using dynamic CT myocardial perfusion imaging (CT-MPI) as a reference standard. Materials and Methods: Dynamic CT-MPI and coronary CT angiography (CCTA) data obtained from 498 symptomatic patients were retrospectively reviewed. Seventy-five patients (mean age ± standard deviation, 62.7 ± 13.2 years; 48 males) who showed myocardial bridging in the left anterior descending artery without concomitant obstructive stenosis on the imaging were included. The change in CT-FFR across myocardial bridging (ΔCT-FFR, defined as the difference in CT-FFR values between the proximal and distal ends of the myocardial bridging) in different cardiac phases, as well as other anatomical parameters, were measured to evaluate their performance for diagnosing myocardial bridging-related myocardial ischemia using dynamic CT-MPI as the reference standard (myocardial blood flow < 100 mL/100 mL/min or myocardial blood flow ratio ≤ 0.8). Results: ΔCT-FFRsystolic (ΔCT-FFR calculated in the best systolic phase) was higher in patients with vs. without myocardial bridging-related myocardial ischemia (median [interquartile range], 0.12 [0.08-0.17] vs. 0.04 [0.01-0.07], p < 0.001), while CT-FFRsystolic (CT-FFR distal to the myocardial bridging calculated in the best systolic phase) was lower (0.85 [0.81-0.89] vs. 0.91 [0.88-0.96], p = 0.043). In contrast, ΔCT-FFRdiastolic (ΔCT-FFR calculated in the best diastolic phase) and CT-FFRdiastolic (CT-FFR distal to the myocardial bridging calculated in the best diastolic phase) did not differ significantly. Receiver operating characteristic curve analysis showed that ΔCT-FFRsystolic had largest area under the curve (0.822; 95% confidence interval, 0.717-0.901) for identifying myocardial bridging-related ischemia. ΔCT-FFRsystolic had the highest sensitivity (91.7%) and negative predictive value (NPV) (97.8%). ΔCT-FFRdiastolic had the highest specificity (85.7%) for diagnosing myocardial bridging-related ischemia. The positive predictive values of all CT-related parameters were low. Conclusion: ΔCT-FFRsystolic reliably excluded myocardial bridging-related ischemia with high sensitivity and NPV. Myocardial bridging showing positive CT-FFR results requires further evaluation.

Contrast-Enhanced MR Angiography of Supra-Aortic Arteries: Review of Current Techniques, Diagnostic Accuracy and Common Pitfalls in Steno-Occlusive Diseases

  • Lee, Jeong-Hyun;Kim, Jin-Hyoung;Kim, Hyun-Jeong;Park, Choong-Gon;Lee, Deok-Hee;Lee, Ho-Kyu;Kim, ang-Joon;Suh, Dae-Chul
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.97-97
    • /
    • 2003
  • Contrast-enhanced MR angiography (CE-MRA) gradually occupies its position as a primary evaluation tool forsteno-occlusive disease of supra-aortic cervical arteries. It has several advantages over time-of-flight (TOF) technique such as shorter imaging time, less saturation effect, and less flow- and motion-related artifacts. Diverse methods of k-space sampling, imaging sequences, and strategies for image acquisitiontiming have been introduced since its early clinical application. Especially, methods of k-space sampling and image acquisition timing are very important to achieve maximal arterial enhancement and suppress venous signal while maintaining large scan coverage and high spatial resolution. In addition, regardless of several advantages over TOF technique, it still has a tendency to overestimate the degree of stenosis in patients with carotid or vertebralartery disease. In this exhibit, we will overview the current techniques of CE-MRA with special attention to methods of k-space sampling and image acquisition timing. We will also discuss diagnostic accuracy of CE-MRA in patients with supra-aortic cervical artery stenosis and artifacts frequently misinterpreted as steno-occlusive lesion on CE-MRA.

  • PDF

Analysis of Meridian Response by Sound Stimulus in Body (음향 자극에 의한 인체 경락의 반응분석)

  • Kim, Yong-Chin;Jeong, Dong-Myong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.3
    • /
    • pp.47-54
    • /
    • 2001
  • This study is to analyze the impedance response in human body by acoustic stimulation on acupoints and contrast parte; for objectification of the meridian substance. It is to verify meridian pathway and channel theory or bio-energy in body. This paper proposes to make an hypothesis about the underground water theory. The meridian has not tube or pipe line type channel but bio-energy flow along the channel similar to flowing pattern of underground water in body. It was analyzed the current characteristic or impedance response after acoustic stimulation by sound wave of 5 specific tones. The response characteristics of current stimulation are measured by the average current magnitude and variation ratio or meridian. The current variation ratio or Live Meridian(gung) 33.2%, Heart Meridian(sang) 30.7% Kidney Meridian (gak) 33.1%, Spleen Meridian(chi) 33.9%, Lung Meridian (wo) 30.7% are to be compared to contrast parts (non-acupoint and meridian). In experimental results, meridian is discrimination to non-meridian, and 5 vital meridians have a reciprocal relationship with sound wave of 5 specific tones.

  • PDF