• Title/Summary/Keyword: contrast control

Search Result 1,833, Processing Time 0.034 seconds

Simultaneous Measurement of Size and Velocity of Microbubbles inside Opaque Tube Using X-ray PTV Technique (X-ray PTV 기법을 이용한 불투명 튜브 내부의 미세기포의 크기 및 속도 동시 측정)

  • Kim, Seok;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.2
    • /
    • pp.69-75
    • /
    • 2006
  • The microbubbles were used in various fields, such as turbulent control, drag reduction, material science and life science. The X-ray PTV using X-ray micro-imaging technique was employed to mea-sure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Micro-bubbles of $10{\sim}60{\mu}m$ diameter moving upward in an opaque tube (${\phi}$=2.7mm) were tested. Due to the different refractive indices of water and air, phase contrast X-ray images clearly show the exact size and shape of over-lapped microbubbles. In all of the working fluids tested (deionized water, tap water, 0.01 and 0.10M NaCl solutions), the measured terminal velocity of the microbubbles rising through the solution was proportional to the square of the bubble diameter. The rising velocity was increased with increasing mole concentration. The microbubble can be useful as contrast agent or tracer in life science and biology. The X-ray PTV technique should be able to extract useful information on the behavior of various bio/microscale fluid flows that are not amenable to analysis using conventional methods.

  • PDF

ULTRASTRUCTURAL STUDY ON THE EFFECTS OF RETROGRADE INFUSION OF WATER-SOLUBLE CONTRAST MEDIA ON THE RABBIT SUBMANDIBULAR GLAND (수용성조영제의 주입이 가토악하선조직에 미치는 영향에 관한 전자현미경적 연구)

  • Kim Eun-Kyung;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.17 no.1
    • /
    • pp.123-135
    • /
    • 1987
  • The author observed the effects of retrograde infusion of water soluble contrast media (Tele- brix 30) on the rabbit submandibular glands and compared the effects of different degrees of filling. 26 rabbits were divided into 2 groups of 12 each as experimentals and I group of 2 as normal controls. One experimental group was filled with 0.2㎖ and the other with 0.4㎖. Right submandibular gland of each rabbit was infused with contrast media and left one with physiologic saline as a experimental control, at a constant rate of 0.12㎖/min. using an infusion pump via the main excretory duct. Immediately after the infusion of contrast media, oblique lateral radiographs of the glands were made with occlusal film in order to confirm the glandular filling. The rabbits were sacrificed after varying periods (1, 8, 24 hours and 3, 6, 10 days) and the tissues were prepared for light and electron microscopic examination. The results were as follows: 1. In glands filled with 0.2㎖ contrast media, the initial changes were a few vacuole formation in the acini and slight dilation of the intralobular duct. The moderately severe changes such as vacuole formation in the acini, the abnormal substructure within the secretory granule, dilation of acinar and intercalated duct lumen, scalloping of striated duct lumen and inflammatory cell infiltrate were observed at 3 days. The general appearance was successively recovered, so the tissue had a normal appearance at 10 days. 2. In glands filled with 0.4㎖ contrast media, the most prominent alterations such as severe acinar atrophy, decreased number of secretory granules, proliferation of connective tissue stroma and pronounced inflammatory cell infiltrates appeared at 6 days. Although the general appearance returned to be almost normal at 10 days, acinar cells showed some atrophy and decreased secretory granules. 3. In glands subjected to 0.4㎖ infusion, the alterations were more severe and the recovery was slower than those seen in the glands to 0.2㎖ infusion.

  • PDF

The Effects of Linguistic Contrast and Conceptual Hierarchy on Children's Word Learning (언어대비(言語對比)와 개념(槪念)의 위계성(位階性)이 아동의 단어학습에 미치는 효과)

  • Kim, Eun Heui;Lee, Kwee Ok
    • Korean Journal of Child Studies
    • /
    • v.14 no.2
    • /
    • pp.79-94
    • /
    • 1993
  • The purpose of this study was (1) to investigate whether linguistic contrast helps children map a new word into a specific semantic domain when a new word is introduced, (2) to examine the existence of a hierarchy of domains into which children will place a new word, (3) to examine whether children's existing lexicons affect how children map a new word. A total of 320 children from 3 to 6 years of age were drawn from Pusan, Korea. The children were divided into one of four age groups. There were 80 children in each age group. In each group, children were randomly assigned to one of four groups; the linguistic contrast group exposed to color, the linguistic contrast group exposed to shape, a label group and control group. All of the children were tested for production and comprehension of the new word. The results of this study were as follows; (1) The linguistic contrast helped children learn the meanings of a new word. Especially, children age 4 or more showed a significant effect for linguistic contrast; however, it was not sufficient to teach 3-year-old the correct, referent of a term. (2) There was a hierarchy of domains into which children mapped a new word. There was no significant effect for domains into which 3-year-old children mapped the new word, but from 4 years of age children showed a preference for assuming a new word refered to an object's shape rather than its color. (3) Children's existing lexicon had no effect, on how children comprehend a new word.

  • PDF

Studies of the side effects on using the contrast media: It's characteristic and management (조영제를 사용하는 환자의 부작용: 특성과 관리에 관한 연구)

  • Seon, Jong-Ryoul;Yoo, Se-Jong
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.427-431
    • /
    • 2014
  • The purpose of this study is to monitor the current adverse reactions in administering CT contrast agents at general hospitals and also to suggest the practical guidelines to minimize the risk and to show the successful patient management. At four Dajeon city general hospitals, the contrast agents were administered in 646,828 cases and the overall prevalence of adverse reactions was 4,110 cases from January 2010 to December 2013. However, we excluded the two hospitals' 3,658 cases because the patients' data was inadequate. Consequently, the case surveys on the rest of 452 cases have been studied and submitted. After comparing the patients with a control group, we evaluated that the key factors of the adverse reactions were the gender and age difference of the patients, the examination period, the examination method, the quantity and administrating speed of the contrast agents. Even though the four general hospitals have their own management systems on adverse reactions, but their systems were not satisfying. To improve the quality of the management systems and to investigate further cases, some hospital administration procedures on the subject should be systemized and general hospitals should follow the recommended procedures. Moreover, the existing three-year-term evaluation should not only judge the adverse reaction management but also conclude some details on the sub criteria of the evaluation. The details on the sub criteria include the contrast agent characters, the quantity and administrating speed of the drug, the incidents' occurred time, an anamnesis; a case history, the medical history of the patients and the reaction occurring body parts, and the examination title. The details of the medical examiners are also added to the sub criteria.

Investigation of the Characteristics of New, Uniform, Extremely Small Iron-Based Nanoparticles as T1 Contrast Agents for MRI

  • Young Ho So;Whal Lee;Eun-Ah Park;Pan Ki Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.10
    • /
    • pp.1708-1718
    • /
    • 2021
  • Objective: The purpose of this study was to evaluate the magnetic resonance (MR) characteristics and applicability of new, uniform, extremely small iron-based nanoparticles (ESIONs) with 3-4-nm iron cores using contrast-enhanced magnetic resonance angiography (MRA). Materials and Methods: Seven types of ESIONs were used in phantom and animal experiments with 1.5T, 3T, and 4.7T scanners. The MR characteristics of the ESIONs were evaluated via phantom experiments. With the ESIONs selected by the phantom experiments, animal experiments were performed on eight rabbits. In the animal experiments, the in vivo kinetics and enhancement effect of the ESIONs were evaluated using half-diluted and non-diluted ESIONs. The between-group differences were assessed using a linear mixed model. A commercially available gadolinium-based contrast agent (GBCA) was used as a control. Results: All ESIONs showed a good T1 shortening effect and were applicable for MRA at 1.5T and 3T. The relaxivity ratio of the ESIONs increased with increasing magnetic field strength. In the animal experiments, the ESIONs showed peak signal intensity on the first-pass images and persistent vascular enhancement until 90 minutes. On the 1-week follow-up images, the ESIONs were nearly washed out from the vascular structures and organs. The peak signal intensity on the first-pass images showed no significant difference between the non-diluted ESIONs with 3-mm iron cores and GBCA (p = 1.000). On the 10-minutes post-contrast images, the non-diluted ESIONs showed a significantly higher signal intensity than did the GBCA (p < 0.001). Conclusion: In the phantom experiments, the ESIONs with 3-4-nm iron oxide cores showed a good T1 shortening effect at 1.5T and 3T. In the animal experiments, the ESIONs with 3-nm iron cores showed comparable enhancement on the first-pass images and superior enhancement effect on the delayed images compared to the commercially available GBCA at 3T.

Sound manipulation: Theory and Applications (음장 제어의 이론과 그 적용)

  • Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.468-471
    • /
    • 2008
  • Sound manipulation is to control sound field using multiple sound sources for appropriate purposes. In linear acoustics, a sound can be constructed by superimposing several fundamental sound fields such as a planewave and sphere shape sound field. That is how we manipulate sound field. In this paper, we introduce the theory of sound manipulation and its applications from the examples of the generation of fundamental sound field: a circle, a ring shape sound field and a planewave field.

  • PDF

A Study of MPPT algorithm for Low-insolation (저일사강도에서 MPPT를 동작시키기 위한 알고리즘 연구)

  • Kim, Ki-Hyun;Yu, Gwon-Jong;Jung, Young-Seok;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.473-475
    • /
    • 2001
  • This paper proposed a MPPT ( Maximum Power Point Tracking) control algorithm for PV(Photovoltaic) array based on a modified constant voltage control MPPT algorithm at low-insolation. This method which combines a IncCond(Incremental Conductance) and a constant voltage control algorithm. In contrast to the typical conventional MPPT algorithm, the proposed method have been obtained high efficiency and good performance. The proposed algorithm is verified through simulation result. In order to confirm the availability of the scheme, a simulation used PSIM and ACSL software tool.

  • PDF

Methylene blue-catalyzed photodecomposition of guanine (Methylene Blue에 의한 guanine의 광분해 현상)

  • 홍순우;변우현
    • Korean Journal of Microbiology
    • /
    • v.10 no.1
    • /
    • pp.35-40
    • /
    • 1972
  • 1) The photodecomposition rate of guanine being catalized by methylene blue ws 53.7% in contrast with 9.3% that of dark control for 180 min. 2) In guanine control, the decomposition rate was very low. For 180 min., the rate was 8.1% in illuminated sample and 3.9% in non-illuminated sample. 3) The decomposition rate of methylene blue was obviously interfered by the existence of guanine. In guanine and methylene blue mixture solution, the net decomposition rate, excluding that of dark control ws 39.2% and in dye only solution, it was 48.5%.

  • PDF

A Real-Time Histogram Equalization System with Automatic Gain Control Using FPGA

  • Cho, Jung-Uk;Jin, Seung-Hun;Kwon, Key-Ho;Jeon, Jae-Wook
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.4
    • /
    • pp.633-654
    • /
    • 2010
  • High quality camera images, with good contrast and intensity, are needed to obtain the desired information. Images need to be enhanced when they are dark or bright. The histogram equalization technique, which flattens the density distribution of an image, has been widely used to enhance image contrast due to its effectiveness and simplicity. This technique, however, cannot be used to enhance images that are either too dark or too bright. In addition, it is difficult to perform histogram equalization in real-time using a general-purpose computer. This paper proposes a histogram equalization technique with AGC (Automatic Gain Control) to extend the image enhancement range. It is designed using VHDL (VHSIC Hardware Description Language) to enhance images in real-time. The system is implemented with an FPGA (Field Programmable Gate Array). An image processing system with this FPGA is implemented. The performance of this image processing system is measured.