• 제목/요약/키워드: contrast

검색결과 13,372건 처리시간 0.044초

초음파 영상의 콘트라스트 향상을 위한 전역적, 적응적 방법의 융합 (Fusion of Global and Adaptive Methods for Contrast Enhancement of Ultrasound Images)

  • 윤재호;박래홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.357-358
    • /
    • 2007
  • Contrast enhancement in the field of ultrasound imaging contributes to improve the accuracy of medical diagnosis by enhancing the visibility of ultrasound images. This paper proposes a contrast enhancement method that improves the contrast of ultrasound images both globally and locally by fusing global and adaptive contrast enhancement methods. Experimental results show that our approach yields more competitive results than the existing global and adaptive contrast enhancement methods in enhancing the visibility of ultrasound images.

  • PDF

Improved Human Factors of Electroluminescent Displays using Optical Interference Effect

  • Krasnov, Alexey N.;Kim, Woo-Young
    • Journal of Information Display
    • /
    • 제4권2호
    • /
    • pp.7-12
    • /
    • 2003
  • We discuss main techniques to improve legibility of electroluminescent displays. Emphasis is placed on use of destructive optical interference to cancel ambient light reflected from the back electrode of the device. Basic optical principles and material composition of the optical interference contrast-enhancing stack (CES) are presented. We also describe the improved human factors of electroluminescent devices assisted with a CES. Achromatic contrast is the most important contributor to display's legibility. In some conditions color contrast may also be important. Contributing to both luminance and color contrast enhancement, the contrast-enhancing stack may play an important role in various display applications.

원자력현미경의 위상차영상을 이용한 나노표면의 미소기계적 특성 평가 (Estimation of Nanomechanical Properties of Nanosurfaces Using Phase Contrast Imaging in Atomic Force Microscopy)

  • 안효석
    • 한국공작기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.115-121
    • /
    • 2007
  • Phase contrast imaging in atomic force microscopy showed a promise as an effective tool for better understanding of micromechanical properties of surfaces at nano scale. A qualitative estimation model for phase contrast images obtained with a tapping mode AFM was developed. This investigation demonstrated the high efficiency of combined analysis of topography and phase contrast images for characterizing nanosurfaces. Phase contrast images allowed estimation of relative stiffness(elastic modulus) of the sample surface. The phase contrast images revealed a significant inhomogeneity of the nano scale worn surfaces. Phase contrast images are also capable of revealing the formation of tribofilms.

MR조영제와 분자영상 (MR Contrast Agents and Molecular Imaging)

  • 문우경
    • 대한핵의학회지
    • /
    • 제38권2호
    • /
    • pp.205-208
    • /
    • 2004
  • The two major classes of magnetic resonance (MR) contrast agents are paramagnetic contrast agents, usually based on chelates of gadolinium generating T1 positive signal enhancement, and super-paramagnetic contrast agents that use mono- or polycrystalline iron oxide to generate strong T2 negative contrast in MR images. These paramagnetic or super-paramagnetic complexes are used to develop new contrast agents that can target the specific molecular marker of the cells or tan be activated to report on the physiological status or metabolic activity of biological systems. In molecular imaging science, MR imaging has emerged as a leading technique because it provides high-resolution three-dimension maps of the living subject. The future of molecular MR imaging is promising as advancements in hardware, contrast agents, and image acquisition methods coalesce to bring high resolution in vivo imaging to the biochemical sciences and to patient care.

Enteral MRI contrast media를 이용한 여성골반 자기공명영상의 유용성 (A Study on Utility of Magnetic Resonance Imaging for Female Pelvic Cavity using Enteral MRI Contrast Media)

  • 김함겸
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권1호
    • /
    • pp.29-34
    • /
    • 1997
  • For radiological test in soft tissue or neighboring part with same signal intensity, proper test method and equipment shall be selected as needed. In case of female pelvic cavity, ultrasonography or computed tomography alternatively used, but MRI can be more usefully applied to design treatment method or operation plan by improving the diagnostic accuracy and careful observation of lesion characteristics. Magnetic Resonance Imaging using recently developed Enteral MRI contrast media can acquire more diagnostic information than using only intravenous contrast media. Thus this study attempted to examine the utility of anatomic structure and diagnostic acquisition by imaging the female pelvic cavity using Enteral MRI contrast media. As a result of analyzing magnetic resonance Imaging after administering Enteral MRI contrast media to pelvic cavity suspect patients, more diagnostic information media could be acquired than only using Intravenous contrast. Expecially, in the diagnosis of lesion position, shape, distinction from neighboring tissues it is thought that external Enteral MRI contrast media should be used.

  • PDF

고해상도 FPD를 위한 실시간 Contrast Enhancer System의 설계 및 구현 (The Design and Implementation of Real Time Contrast Enhancer System for High Resolution FPD)

  • 서범석;최철호;권병헌
    • 디지털콘텐츠학회 논문지
    • /
    • 제5권1호
    • /
    • pp.79-86
    • /
    • 2004
  • 본 논문에서는 고해상도 FPD(Flat Panel Display)에서 동영상의 화질 향상을 위한 실시간 Contrast Enhancer 알고리즘을 제안하고 이를 구현하였다. 또한 입력되는 영상신호의 밝기 분포에서 영상의 평균과 분산을 이용하여 적응적으로 처리하는 적응형 콘트라스트 제어 기법을 제안하였다. 설계된 Contrast Enhancer는 기존화면과 비교하여 정량적으로 측정하였으며, 실제 유용성을 검증하기 위해 LG의 30인치 TFT-LCD TV에 인터페이스하여 구현하였다.

  • PDF

실시간 열영상 대조비 개선을 위한 대역추출 및 플래토 평활화 알고리즘 적용 (Application of Local Histogram and Plateau Equalization Algorithm for Contrast Enhancement of Real Time Thermal Image)

  • 조흥기;김수곤;전희종
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권2호
    • /
    • pp.76-85
    • /
    • 2004
  • In this paper, the contrast enhancement method of thermal image is proposed and it is the plateau equalization algorithm using local histogram for the real time display of infrared imagery. Through hardware implementing, its practicality and adequacy are proved. Examinations are executed to verify the effect of contrast enhancement by bright control and contrast control automatic to the plateau value in the manual mode, and that verified the effect of contrast enhancement in the automatic mode and the practicality in the real system. According to the experiment results, the proposed "the application of local histogram and plateau equalization algorithm for contrast enhancement of real time thermal image"in this dissertation is the verified method for the thermal imaging contrast enhancement.

웨이브렛과 기저 계수를 이용한 X-ray 영상의 대조도 향상기법 (Contrast Enhancement for X-ray Images Based on Combined Enhancement of Scaling and Wavelet Coefficients)

  • 박천주;김도일;장도윤;윤한빈;최보영;김호경;이형구
    • 한국의학물리학회지:의학물리
    • /
    • 제19권3호
    • /
    • pp.150-156
    • /
    • 2008
  • 본 연구에서는 이산 웨이브렛 도메인에서 기저계수와 웨이브렛 계수의 변환을 이용하여 X-ray 이미지의 대조도를 향상시키는 방법을 제안하였다. 기저 함수의 변환은 기존에 나와있는 contrast limited adaptive histogram equalization (CLAHE)와 multi-scale image contrast amplification (MUSICA)와 같은 보편적인 영상의 대조도 향상 기법을 적용하였으며 대조도가 향상된 저해상도 기저 계수의 역변환으로 인한 Blurring 현상을 방지하고 또한 이미지의 선명도를 향상시키기 위하여 웨이브렛 계수에 sigmoid function을 적용하였다. 본 알고리즘에 대한 성능 평가를 위하여 contrast detail mammography(CDMAM) 팬텀의 영상을 획득하여 기존에 사용한 대조도 향상 기법들과 contrast to noise ratio (CNR) 및 line profile에 대한 비교평가를 실시 하였고 그 결과 기존의 대조도 향상기법을 웨이브렛 도메인에서 적용하는 것이 뛰어나다는 것을 알 수 있었다. 본 영상 대조도 향상기법은 영상의 대조도를 증가시키는 동시에 잡음의 증폭을 효율적으로 억제할 수 있다. 따라서 본 연구는 의료 영상뿐 만이 아닌 대조도와 선명도가 중요시되는 여려 분야에 적용될 수 있으리라 기대된다.

  • PDF

방사선 검사에 사용되는 조영제 Iopamidol의 안전성 평가 (Safety Evaluation of Iopamidol Contrast Medium Used for Radiological Examination of a Local Clinic in Korea)

  • 박창묵;이보름;송태범;장제관;이유정;이명구;임성실
    • 약학회지
    • /
    • 제53권6호
    • /
    • pp.328-333
    • /
    • 2009
  • Contrast media are substances that are used to enhance the contrast of structures or fluids within the body in medical imaging. Those are commonly used to enhance the visibility of blood vessels and the gastrointestinal tract. The aim of this study is to evaluate patients who got injected iopamidol, developed as one of contrast medium regarding changes in cardiovascular system and especially, adverse drug reactions. This study were performed on randomly selected a total of 51 patients (range of 15~85 years old) who got injected contrast medium, Iopamidol at a P hospital in Gyeonggi province from September 22nd, 2008 to January 24th, 2009. Data were collected by questionnaire though person to person. We analyzed the data by SPSS (Version 12. for windows). Methods of analysis were frequency and cross analysis. In results, 19.6% (n=10) were founded for adverse drug reactions of contrast medium. 25.0% (n=4) of 10 patients who had adverse drug reactions of contrast medium had took abdomen contrast test. 2 patients of those took contrast test for chest. Also, 3.9% (n=2) patients felt vomiting and nausea after injection of contrast medium. In conclusion, 19.6% patients experienced adverse drug reaction of contrast medium. Therefore, when taking radiation test, we should make efforts to minimize adverse drug reactions to achieve suitable and effective treatment.

Oral Administration of Nonionic Water-Soluble Contrast Media to Treat Meconium Obstruction in Premature Infants: A Preliminary Study

  • Hong, Hyun Sook;Kim, Sung Shin;Park, Ga Young
    • Neonatal Medicine
    • /
    • 제28권1호
    • /
    • pp.22-28
    • /
    • 2021
  • Purpose: Meconium obstruction of prematurity (MOP) predisposes premature infants to intestinal perforation and prolonged hospitalization if not diagnosed and treated promptly. A standard contrast enema is less effective to treat infants with distal ileal obstructions because the contrast may not reach the obstructed areas. In an effort to avoid risky surgery, we administered oral contrast media to seven clinically diagnosed patients with MOP whose obstructions were not relieved via conventional sonography-guided contrast enema. We retrospectively evaluated whether oral nonionic water-soluble contrast media relieves MOP. Methods: Seven of 67 premature infants with MOP were administered oral contrast media from June 2015 to January 2019. Patients were followed-up radiographically for bowel distention and evacuation of contrast media after oral administration. We recorded radiographic improvements, meconium evacuation, time to first feeding after oral contrast media administration, maternal history, and neonatal clinical factors. Results: We evaluated five male and two female infants. The median gestational ages and body weights at birth were 27+5 weeks and 890 g, respectively. Radiography in five infants revealed multiple distended intestinal loops without air-fluid interfaces. Two infants had gasless abdomens, in which only stomach gas was visible. Oral contrast media (median, 2.5 mL) were administered at a median age of 7 days; five infants (5/7, 71.4%) responded to this treatment. The remaining two infants, who had ileal stenosis and hypoganglionosis, were surgically managed. Five infants (5/7, 71.4%) had maternal risk factors, and two (28.6%) were small for gestational age. Conclusion: Nonionic oral water-soluble contrast medium can serve as a valuable adjunct treatment in premature infants with meconium obstruction.