• Title/Summary/Keyword: contouring

Search Result 237, Processing Time 0.032 seconds

Error criteria in stateline concept based contouring system (Stateline 개념을 이용한 이송장치에서 오차평가기준)

  • Jung, Byung-Kyu;Choi, Woo-Chun
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1621-1625
    • /
    • 2007
  • This paper examines the interpolation algorithms and error criteria using stateline based control architectures that is proposed in the University of British Columbia. The main purpose of this paper is checking the influences of jerk in error criteria and judging several interpolation algorithms that are used for positioning. The performance of the extended error criteria and interpolation algorithm are demonstrated by simulation. It is found that a slight improvement was achieved by applying jerk in the error checking criteria and that spline interpolation yields stable result.

  • PDF

Development of Computer Aided System for Error Assessoment for Multi-axis Machine Tools using the Double Ball Bar (기구볼바를 이용한 공작기계의 오차평가 시스템 개발)

  • 문준희;박희재;주종남
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.336-342
    • /
    • 1994
  • This paper presents an useful technique for assessing the volumetric error in multi_axis machine tools using the kinematic double ball bar and 3 dimensional spherical contouring. The developed system proposes the 3 dimensional spherical contour for the error analysis. The developed system input the measured radial data, analysing the volumetric errors such as positional, strightness, angle, and squareness errors, etc. The developed system has been tested in a practical machine tool, and showed high

  • PDF

리니어모터 탑재 HMC의 운동특성 평가

  • 허남환;강은구;홍원표;최헌종;최우천
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.328-328
    • /
    • 2004
  • 최근의 생산시스템은 수요자의 요구에 맞추어 다종소량화 경향이 뚜렷해지고 부품 또는 제품의 다기능화 및 소형화가 급속하게 진전되고 있으며, 여기에 보조를 맞추어 제품의 고정밀화가 그 어느 때보다 강하게 요구되고 있다. 이에 따라 공작기계를 이용한 정밀 가공기술의 필요성이 증가하게 되었고 공작기계가 공작물의 가공정도에 미치는 영향에 대한 평가가 많은 관심을 모으고 있다. 이는 가공된 공작물의 정밀도는 그것을 가공한 공작기계의 정밀도에 의해 좌우되기 때문이다.(중략)

  • PDF

Computer-Assisted Virtual Simulation and Surgical Treatment for Facial Asymmetry Induced by Fibrous Dysplasia

  • Lee, Jung-woo
    • Journal of International Society for Simulation Surgery
    • /
    • v.3 no.1
    • /
    • pp.33-35
    • /
    • 2016
  • Fibrous dysplasia(FD) is a disorder in which normal bone is replaced with pathologic tissue. When occurring in craniofacial regions, the zygomaticomaxillary complex is most commonly affected and this pathologic lesion results in facial asymmetry. and By using computer-assisted virtual simulation, precise maxillofacial contouring was achieved for harmonious facial morphology and the surgical procedure was simplified and the surgery brought satisfactory results in terms of both esthetics and functionality.

Virtual lymph node analysis to evaluate axillary lymph node coverage provided by tangential breast irradiation

  • Park, Shin-Hyung;Kim, Jae-Chul;Lee, Jeong Eun;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.33 no.1
    • /
    • pp.50-56
    • /
    • 2015
  • Purpose: To investigate the coverage of axillary lymph node with tangential breast irradiation fields by using virtual lymph node (LN) analysis. Materials and Methods: Forty-eight women who were treated with whole breast irradiation after breast-conserving surgery were analyzed. The axillary and breast volumes were delineated according to the Radiation Therapy Oncology Group (RTOG) contouring atlas. To generate virtual LN contours, preoperative fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) scans with identifiable LN were fused with the CT scans, and the virtual LN contour were delineated on the CT. Results: The median level I and II axillary volume coverage percentages at the $V_{D95%}$ line were 33.5% (range, 5.3% to 90.4%) and 0.6% (range, 0.0% to 14.6%), respectively. Thirty-one LNs in 18 patients were delineated (26 in level I and 5 in level II). In the level I axilla, 84.6% of virtual LNs were encompassed by the 95% isodose line. In the level II axilla, by contrast, none of the virtual LNs were encompassed by the 95% isodose volumes. There was a substantial discrepancy between the RTOG contouring atlas-based axillary volume analysis and the virtual LN analysis, especially for the level I axillary coverage. The axillary volume coverage was associated with the body mass index (BMI) and breast volume. Conclusion: The tangential breast irradiation did not deliver adequate therapeutic doses to the axillary region, particularly those in the level II axilla. Patients with small breast volumes or lower BMI showed reduced axillary coverage from the tangential breast fields. For axillary LN irradiation, individualized anatomy-based radiation fields for patients would be necessary.

Informed Consent as a Litigation Strategy in the Field of Aesthetic Surgery: An Analysis Based on Court Precedents

  • Park, Bo Young;Kwon, Jungwoo;Kang, So Ra;Hong, Seung Eun
    • Archives of Plastic Surgery
    • /
    • v.43 no.5
    • /
    • pp.402-410
    • /
    • 2016
  • Background In an increasing number of lawsuits doctors lose, despite providing preoperative patient education, because of failure to prove informed consent. We analyzed judicial precedents associated with insufficient informed consent to identify judicial factors and trends related to aesthetic surgery medical litigation. Methods We collected data from civil trials between 1995 and 2015 that were related to aesthetic surgery and resulted in findings of insufficient informed consent. Based on these data, we analyzed the lawsuits, including the distribution of surgeries, dissatisfactions, litigation expenses, and relationship to informed consent. Results Cases were found involving the following types of surgery: facial rejuvenation (38 cases), facial contouring surgery (27 cases), mammoplasty (16 cases), blepharoplasty (29 cases), rhinoplasty (21 cases), body-contouring surgery (15 cases), and breast reconstruction (2 cases). Common reasons for postoperative dissatisfaction were deformities (22%), scars (17%), asymmetry (14%), and infections (6%). Most of the malpractice lawsuits occurred in Seoul (population 10 million people; 54% of total plastic surgeons) and in primary-level local clinics (113 cases, 82.5%). In cases in which only invalid informed consent was recognized, the average amount of consolation money was KRW 9,107,143 (USD 8438). In cases in which both violation of non-malfeasance and invalid informed consent were recognized, the average amount of consolation money was KRW 12,741,857 (USD 11,806), corresponding to 38.6% of the amount of the judgment. Conclusions Surgeons should pay special attention to obtaining informed consent, because it is a double-edged sword; it has clinical purposes for doctors and patients but may also be a litigation strategy for lawyers.

The new classification for fatty-type gynecomastia (lipomastia) and 1000 cases review (지방형 여성형유방증에 대한 새로운 분류와 1000증례)

  • Yoon, Sang Yub;Kang, Min Gu
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.773-778
    • /
    • 2009
  • Purpose: The authors propose the new classification of fatty - type gynecomastia(lipomastia) which can serve as a guide for modifying the periareolar technique. Methods: A retrospective analysis was made of 1000 cases of lipomastia operated on in the last 17 months. The extent of the clinical result, the technique employed, and the complications were observed. On the basis of this review the authors observed that at grade I(fat component < 50 ml, fibroglandular component < 3 g each breast), flattening of the thorax can be achieved by means of stab incision, ultrasound - assisted lipectomy(UAL), scavenging suction - assisted lipectomy(SAL) and tissue shaving. At grade II(50 < < 150 ml, 3 < < 5 g), stab incision, UAL, SAL and pull - out method(POM) using small curved scissors. At grade III(150 < < 300 ml, 5 < < 15 g and prominent inframammary fold(IMF)), minimal incision (5 - 6 mm), UAL, SAL and POM using small angulated scissors, and blunting IMF. At grade IV (300 < < 500 ml, 15 < < 30 g, and glandular ptosis), minimal incision (5 - 6 mm), UAL, SAL, fibroglandular excision using small angulated scissors, cutting IMF and fixation of nipple - areola complex(NAC) becomes necessary. At grade V (> 500 ml, > 30 g and ptosis), small incision (7 - 8 mm), UAL, SAL, fibroglandular excision using large angulated scissors, cutting IMF, upper repositioning of NAC and delayed circumareolar skin reduction or chest lifting becomes necessary. Results: The complications were minimal but there were hematoma (n = 7), infection (n = 3) and hypertrophic scar (n =13). Almost patients were satisfied with the outcome. Conclusion: This simple classification may help in choosing the most suitable treatment, thus avoiding insufficient or invasive treatments and undesirable scars.