Optimization of Antimicrobial Activity Against Food-borne Pathogens in Grapefruit Seed Extract and a Lactic Acid Mixture (식품위해미생물에 대한 자몽종자 추출물과 젖산 혼합물의 항균효과 최적화)

  • Kim, Hae-Seop;Park, Jeong-Wook;Park, In-Bae;Lee, Young-Jae;Kim, Jeong-Mok;Jo, Yeong-Cheol
    • Food Science and Preservation
    • /
    • v.16 no.4
    • /
    • pp.472-481
    • /
    • 2009
  • Response surface methodology (RSM) is frequently used for optimization studies. In the present work, RSM was used to determine the antimicrobial activitiesof grapefruit seed extract (GFSE) and a lactic acid mixture (LA) against Staphylococcus aureus, Bacillus cereus, Escherichia coli, Salmonella typhimurium, Pseudomonas fluorescens, and Vibrio parahaemolyticus. A central composite design was used to investigate the effects of independent variables on dependent parameters. One set of antimicrobial preparations included mixtures of 1% (w/w) GFSE and 10% (w/w) LA, in which the relative proportions of component antimicrobials varied between 0 and 100%. In further experiments, the relative proportions were between 20% and 100%. Antimicrobial effects against various microorganisms were mathematically encoded for analysis. The codes are given in parentheses after the bacterial names, and were S. aureus ($Y_1$), B. cereus ($Y_2$), E. coli ($Y_3$), S. typhimurium ($Y_4$), P. fluorescens ($Y_5$), and V. parahaemolyticus ($Y_6$). The optimum antimicrobial activity of the 1% (w/w) GFSE:10% (w/w) LA mixture against each microorganism was obtained by superimposing contour plots ofantimicrobial activities on measures of response obtained under various conditions. The optimum rangesfor maximum antimicrobial activity of a mixture with a ratio of 1:10 (by weight) GFSE and LA were 35.73:64.27 and 56.58:43.42 (v/v), and the optimum mixture ratio was 51.70-100%. Under the tested conditions (a ratio of 1% [w/w] GFSE to 10% [w/w] LA of 40:60, and a concentration of 1% [w/w] GFSE and 10% [w/w] LA, 70% of the highest value tested), and within optimum antimicrobial activity ranges, the antimicrobial activities of the 1% (w/w) GFSE:10% (w/w) LA mixture against S. aureus ($Y_1$), B. cereus ($Y_2$), E. coli ($Y_3$), S. typhimurium ($Y_4$), P. fluorescens ($Y_5$), and V. parahaemolyticus ($Y_6$) were 24.55, 25.22, 20.20, 22.49, 23.89, and 28.04 mm, respectively. The predicted values at optimum conditions were similar to experimental values.

A Study on the Paleotopographic and Structural Analyses of Cherwon Castle in Taebong (태봉 철원도성의 고지형과 구조 분석 연구)

  • HEO, Uihaeng;YANG, Jeongseok
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.2
    • /
    • pp.38-55
    • /
    • 2021
  • Cherwon Castle is located in Pungcheonwon, Cherwon, in the center of the Korean Peninsula. Currently, it is split across the Demilitarized Zone (DMZ) between the two Koreas. It attracts attention as a symbol of inter-Korean reconciliation and as cultural heritage that serves as data in making important policy decisions on the DMZ. Despite its importance, however, there has not been sufficient investigation and research done on Cherwon Castle. This is due to the difficulty involved in investigation and research and is caused by the site's inaccessibility. As a solution, the current investigative methods in satellite and aerial archeology can be applied to interpret and analyze the structure of Cherwon Castle and the features of its inner space zoning. Cherwon Castle was built on the five flat hills that begin in the northern mountainous hills and stretch to the southwest. The inner and outer walls were built mainly on the hilly ridges, and the palace wall was built surrounding a flat site that was created on the middle hill. For each wall, the sites of the old gates, which were erected in various directions , have been identified. They seem to have been built to fit the direction of buildings in the castle and the features of the terrain. The castle was built in a diamond shape. The old sites of the palace and related buildings and landforms related to water drainage were identified. It was verified that the roads and the gates were built to run from east to west in the palace. In the spaces of the palace and the inner castle, flat sites were created to fit different landforms, and building sites were arranged there. Moreover, the contour of a reservoir that is believed to be the old site of a pond has been found; it lies on the vertical extension of the center line that connects the palace and the inner castle. Between the inner castle and the outer castle, few vestiges of old buildings were found, although many flat sites were discovered. Structurally, Cherwon Castle is rotated about nine degrees to the northeast, forming a planar rectangle. The planar structure derives from the castle design that mimics the hilly landform, and the bending of the southwestern wall also attests to the intention of the architects to avoid the wetland. For now, it is impossible to clearly describe the functions and characters of the building sites inside the castle. However, it is believed that the inner castle was marked out for space for the palace and government offices, while the space between the outer and inner castle was reserved as the living space for ordinary people. The presence of the hilly landform diminishes the possibility that a bangri (grid) zoning system existed. For some of the landforms, orderly zoning cannot be ruled out, as flat areas are commonly seen. As surveys have yet to be conducted on the different castles, the time when the walls were built and how they were constructed cannot be known. Still, the claim to that the castle construction and the structuring of inner spaces were inspired by the surrounding landforms is quite compelling.

Evaluation of the usefulness of the method according to changes in patient breathing during chest 4D CT imaging (흉부 4D CT에서 호흡 변화에 대한 일시 중지 및 재개 방법의 유용성 평가)

  • Heo, Sol;Shin, Chung Hun;Jeong, Hyun Sook;Yoo, Soon Mi;Kim, Jeong Mi;Yun, In Ha;Hong, Seung Mo;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.47-54
    • /
    • 2021
  • Purpose : In order to evaluate the usefulness of clinical application of the Pause & Resume methods by comparing and analyzing the data stability and dose reduction effect when repeat scan assuming irregular breathing and using the Pause & Resume method during chest 4D CT using QuasarTM Phantom. Materials and Methods : Using the QuasarTM Phantom, set the breathing rate per minute to 15 BPM and 7.5 BPM, and set the S15 point as an irregular breathing section, and then placed OSLD to this point and use the Pause & Resume method to measure the dose of S15. CTDIvol, DLP, and ALARA-CT were used for comparative analysis of radiation dose between Pause & Resume method and Repeat-scan. In order to evaluate the stability and usability of the data applying the Pause & Resume method, the captured images were sorted by Advanced Workstation Volume Share7 and then sent to EclipseTM, the diameter and volume were analyzed by forming a contour on the iron ball in the QuasarTM Phantom Results : When using Pause & Resume, the dose of OSLD measurement increased by 1.97 times in the section of S15. As a result of image evaluation, the average value of all volumes measured with and without the Pause & Resume method at 15 BPM and 7.5 BPM was 15.2 cm3±0.5%.Allthemeasuredvaluesfor the radius of iron ball were 3.1 cm regardless of whether Pause & Resume method was used or not. In the case of using Pause & Resume, 33% decreased from the lowest DLP value and 38% decreased from the highest DLP value of repeat scan, and the effective dose also decreased 32.1% from the minimum value and 37.6% from the maximum value. Conclusion: Irradiation dose was increased by Pause & Resume method because of the repeat scan on the S15 site where assuming irregular breathing occurred, However Pause & Resume method led to a significant reduction in dose on overall scan range. It also proved the usefulness of clinical application of the Pause & Resume method as a result of similar diameters and volumes of iron ball measurement.

Monitoring of Bathymetry Changes in the Coastal Area of Dokdo, East Sea (동해 독도 연안 해저지형 변동 모니터링 연구)

  • Chang Hwan Kim;Soon Young Choi;Won Hyuck Kim;Hyun Ok Choi;Chan Hong Park;Yun Bae Kim;Jong Dae Do
    • Economic and Environmental Geology
    • /
    • v.56 no.5
    • /
    • pp.589-601
    • /
    • 2023
  • We compare high-resolution seabed bathymetry data and seafloor backscattering data acquired, using multi-beam, between 2018 and 2021 to understand topographic changes in the coastal area of Dokdo. The study area, conducted within a 500 m × 500 m in the southern coast between the islands where Dongdo Port is located, has been greatly affected by human activities, waves and ocean currents. The depth variations exhibit between 5 - 70 m. Irregular underwater rocks are distributed in areas with a depth of 20 m or less and 30 - 40 m. As a whole, water depth ranges similar in the east-west direction and become flatter and deeper. The bathymetry contour in 2020 tends to move south as a whole compared to 2018 and 2019. The south moving of the contours in the survey area indicates that the water depth is shallower than before. Since the area where the change in the depth occurred is mainly formed of sedimentary layers, the change in the coast of Dokdo were mainly caused by the inflow of sediments, due to the influence of wind and waves caused by these typhoons (Maysak and Haishen) in 2020. In the Talus area, which developed on the shallow coast between Dongdo and Seodo, the bathymetry changed in 2020 due to erosion or sedimentation, compared to the bathymetry in 2019 and 2018. It is inferred that the changes in the seabed environment occur as the coastal area is directly affected by the typhoons. Due to the influence of the typhoons with strong southerly winds, there was a large amount of sediment inflow, and the overall tendency of the changes was to be deposited. The contours in 2021 appears to have shifted mainly northward, compared to 2020, meaning the area has eroded more than 2020. In 2020, sediments were mainly moved northward and deposited on the coast of Dokdo by the successive typhoons. On the contrary, the coast of Dokdo was eroded as these sediments moved south again in 2021. Dokdo has been largely affected by the north wind in winter, so sediments mainly move southward. But it is understood that sediments move northward when affected by strong typhoons. Such continuous coastal change monitoring and analysis results will be used as important data for longterm conservation policies in relation to topographical changes in Dokdo.

The Research on Recommender for New Customers Using Collaborative Filtering and Social Network Analysis (협력필터링과 사회연결망을 이용한 신규고객 추천방법에 대한 연구)

  • Shin, Chang-Hoon;Lee, Ji-Won;Yang, Han-Na;Choi, Il Young
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.4
    • /
    • pp.19-42
    • /
    • 2012
  • Consumer consumption patterns are shifting rapidly as buyers migrate from offline markets to e-commerce routes, such as shopping channels on TV and internet shopping malls. In the offline markets consumers go shopping, see the shopping items, and choose from them. Recently consumers tend towards buying at shopping sites free from time and place. However, as e-commerce markets continue to expand, customers are complaining that it is becoming a bigger hassle to shop online. In the online shopping, shoppers have very limited information on the products. The delivered products can be different from what they have wanted. This case results to purchase cancellation. Because these things happen frequently, they are likely to refer to the consumer reviews and companies should be concerned about consumer's voice. E-commerce is a very important marketing tool for suppliers. It can recommend products to customers and connect them directly with suppliers with just a click of a button. The recommender system is being studied in various ways. Some of the more prominent ones include recommendation based on best-seller and demographics, contents filtering, and collaborative filtering. However, these systems all share two weaknesses : they cannot recommend products to consumers on a personal level, and they cannot recommend products to new consumers with no buying history. To fix these problems, we can use the information which has been collected from the questionnaires about their demographics and preference ratings. But, consumers feel these questionnaires are a burden and are unlikely to provide correct information. This study investigates combining collaborative filtering with the centrality of social network analysis. This centrality measure provides the information to infer the preference of new consumers from the shopping history of existing and previous ones. While the past researches had focused on the existing consumers with similar shopping patterns, this study tried to improve the accuracy of recommendation with all shopping information, which included not only similar shopping patterns but also dissimilar ones. Data used in this study, Movie Lens' data, was made by Group Lens research Project Team at University of Minnesota to recommend movies with a collaborative filtering technique. This data was built from the questionnaires of 943 respondents which gave the information on the preference ratings on 1,684 movies. Total data of 100,000 was organized by time, with initial data of 50,000 being existing customers and the latter 50,000 being new customers. The proposed recommender system consists of three systems : [+] group recommender system, [-] group recommender system, and integrated recommender system. [+] group recommender system looks at customers with similar buying patterns as 'neighbors', whereas [-] group recommender system looks at customers with opposite buying patterns as 'contraries'. Integrated recommender system uses both of the aforementioned recommender systems to recommend movies that both recommender systems pick. The study of three systems allows us to find the most suitable recommender system that will optimize accuracy and customer satisfaction. Our analysis showed that integrated recommender system is the best solution among the three systems studied, followed by [-] group recommended system and [+] group recommender system. This result conforms to the intuition that the accuracy of recommendation can be improved using all the relevant information. We provided contour maps and graphs to easily compare the accuracy of each recommender system. Although we saw improvement on accuracy with the integrated recommender system, we must remember that this research is based on static data with no live customers. In other words, consumers did not see the movies actually recommended from the system. Also, this recommendation system may not work well with products other than movies. Thus, it is important to note that recommendation systems need particular calibration for specific product/customer types.

Evaluating efficiency of Split VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes (골반 림프선을 포함한 전립선암 치료 시 Split VMAT plan의 유용성 평가)

  • Mun, Jun Ki;Son, Sang Jun;Kim, Dae Ho;Seo, Seok Jin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.145-156
    • /
    • 2015
  • Purpose : The purpose of this study is to evaluate the efficiency of Split VMAT planning(Contouring rectum divided into an upper and a lower for reduce rectum dose) compare to Conventional VMAT planning(Contouring whole rectum) for prostate cancer radiotherapy involving pelvic lymph nodes. Materials and Methods : A total of 9 cases were enrolled. Each case received radiotherapy with Split VMAT planning to the prostate involving pelvic lymph nodes. Treatment was delivered using TrueBeam STX(Varian Medical Systems, USA) and planned on Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28), AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). Lower rectum contour was defined as starting 1cm superior and ending 1cm inferior to the prostate PTV, upper rectum is a part, except lower rectum from the whole rectum. Split VMAT plan parameters consisted of 10MV coplanar $360^{\circ}$ arcs. Each arc had $30^{\circ}$ and $30^{\circ}$ collimator angle, respectively. An SIB(Simultaneous Integrated Boost) treatment prescription was employed delivering 50.4Gy to pelvic lymph nodes and 63~70Gy to the prostate in 28 fractions. $D_{mean}$ of whole rectum on Split VMAT plan was applied for DVC(Dose Volume Constraint) of the whole rectum for Conventional VMAT plan. In addition, all parameters were set to be the same of existing treatment plans. To minimize the dose difference that shows up randomly on optimizing, all plans were optimized and calculated twice respectively using a 0.2cm grid. All plans were normalized to the prostate $PTV_{100%}$ = 90% or 95%. A comparison of $D_{mean}$ of whole rectum, upperr ectum, lower rectum, and bladder, $V_{50%}$ of upper rectum, total MU and H.I.(Homogeneity Index) and C.I.(Conformity Index) of the PTV was used for technique evaluation. All Split VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : Using DVH analysis, a difference between the Conventional and the Split VMAT plans was demonstrated. The Split VMAT plan demonstrated better in the $D_{mean}$ of whole rectum, Up to 134.4 cGy, at least 43.5 cGy, the average difference was 75.6 cGy and in the $D_{mean}$ of upper rectum, Up to 1113.5 cGy, at least 87.2 cGy, the average difference was 550.5 cGy and in the $D_{mean}$ of lower rectum, Up to 100.5 cGy, at least -34.6 cGy, the average difference was 34.3 cGy and in the $D_{mean}$ of bladder, Up to 271 cGy, at least -55.5 cGy, the average difference was 117.8 cGy and in $V_{50%}$ of upper rectum, Up to 63.4%, at least 3.2%, the average difference was 23.2%. There was no significant difference on H.I., and C.I. of the PTV among two plans. The Split VMAT plan is average 77 MU more than another. All IMRT verification gamma test results for the Split VMAT plan passed over 90.0% at 2 mm / 2%. Conclusion : As a result, the Split VMAT plan appeared to be more favorable in most cases than the Conventional VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes. By using the split VMAT planning technique it was possible to reduce the upper rectum dose, thus reducing whole rectal dose when compared to conventional VMAT planning. Also using the split VMAT planning technique increase the treatment efficiency.

  • PDF