• 제목/요약/키워드: continuous dialyzer

검색결과 4건 처리시간 0.02초

Modeling of continuous diffusion dialysis of aqueous solutions of sulphuric acid and nickel sulphate

  • Bendova, Helena;Palaty, Zdenek
    • Membrane and Water Treatment
    • /
    • 제2권4호
    • /
    • pp.267-279
    • /
    • 2011
  • At steady state, the simultaneous transport of sulphuric acid and nickel sulphate through an anion-exchange membrane Neosepta-AFN (Astom Corporation, Tokyo, Japan) was investigated in a two-compartment counter-current dialyzer with single passes. The transport was quantified by the recovery yield of acid, rejection of salt and four phenomenological coefficients, which were correlated with the acid and salt concentrations in the feed. The phenomenological coefficients were determined by the numerical integration of the basic differential equations describing the concentration profiles of the components in the dialyzer. This integration was combined with an optimizing procedure. The experiments proved that the acid recovery yield is in the limits from 63 to 91 %, while salt rejection is in the limits from 79 to 97 % in the dependence on the volumetric liquid flow rate and composition of the feed.

Continuous dialysis of selected salts of sulphuric acid

  • Bendova, Helena;Snejdrla, Pavel;Palaty, Zdenek
    • Membrane and Water Treatment
    • /
    • 제1권3호
    • /
    • pp.171-179
    • /
    • 2010
  • The transport of selected salts of sulphuric acid (cobalt, copper, iron(II), manganese, nickel and zinc sulphate) through an anion-exchange membrane Neosepta-AFN was investigated in a counter-current continuous dialyzer at various salt concentrations and volumetric liquid flow rates. The basic transport characteristics - the rejection coefficient of salt and the permeability of the membrane - were calculated from measurements at steady state. The salt concentration in model mixtures was changed in the limits from 0.1 to 1.0 kmol $m^{-3}$ and the volumetric liquid flow rate of the inlet streams was in the limits from $8{\times}10^{-9}$ to $24{\times}10^{-9}m^3\;s^{-1}$. Under the experimental conditions given, the rejection coefficient of salts tested was in the range from 65% to 94%. The lowest values were obtained for iron(II) sulphate, while the highest for copper sulphate. The maximum rejection of salt was reached at the highest volumetric liquid flow rate and the highest salt concentration in the feed. The permeability ($P_A$) of the Neosepta-AFN membrane for the individual salts was in the range from $0.49{\times}10^{-7}m\;s^{-1}$ to $1.8{\times}10^{-7}m\;s^{-1}$ and it can be described by the following series: $P_{FeSO_4}$ < $P_{NiSO_4}$ < $P_{ZnSO_4}$ < $P_{CoSO_4}$ < $P_{MnSO_4}$ < $P_{CuSO_4}$. The permeability of the membrane was strongly affected by the salt concentration in the feed - it decreased with an increasing salt concentration.

용해기체 분석용 기체감응막 이온선택성 전극 (제 4 보) 관형 PVC막 pH전극을 이용한 황화이온의 연속 · 자동화 정량 (Gas-Sensing Membrane Electrodes for the Determination of Dissolved Gases (Ⅳ). Continuous-Automated Determination of Sulfide Ion Using Tubular PVC Membrane Type pH Electrode)

  • 이흥락;배준웅;오상협
    • 대한화학회지
    • /
    • 제36권5호
    • /
    • pp.638-643
    • /
    • 1992
  • 황화이온검출기로서 2가지 형태의 연속 flow-through 전극계의 분석적 감응성질을 조사하고, 최적조건에서 그들의 감응특성을 직접 비교하였다. 두 검출계에 있어서 측정한 봉우리전위를 황화이온농도의 대수값과 관련지웠으며, 적어도 시간당 20개의 시료를 정량할 수 있었다. pH전극법에서는 투석기를 지나 흘러가는 recipient stream의 pH를 측정하였다. 장치는 연속흐름형의 기체투석기가 관형 polymer 막전극과 연결되도록 설계되어 있다. 이 방법의 최적실험조건은 recipient $5.0 {\times} 10^{-5} M NaOH + 5.0 {\times} 10^{-3} M$ NaCl과 diluent 0.10M $H_2SO_4$이며, recipient stream, diluent stream 및 시료의 유속은 모두 1.0ml/min이다. 황화이온 전극법에서는 시판하는 황화이온선택성 전극을 flow-through cell 속의 황화이온을 검출하는 데에 썼다. 이 방법의 최적실험조건인 황화이온 산화방지 완충제(1.0M NaOH 용액에 3.5g 아스코르브산과 7.6g $Na_2EDTA$를 용해)와 시료의 유속은 각각 1.4 ml/min와 1.0 ml/min이다.

  • PDF

새로운 효소반응기를 이용한 요소의 연속·자동화 정량 (Continuous Automated Determination of Urea Using a New Enzyme Reactor)

  • 이흥락;양승태
    • 대한화학회지
    • /
    • 제36권3호
    • /
    • pp.393-404
    • /
    • 1992
  • 새로운 효소반응기를 쓰는 요소 정량용 연속${\cdot}$자동화 장치의 감응성질을 조사하였다. 효소반응기는 지지체인 nylon-6입자(42∼48 mesh)를 teflon관(안지름 2mm, 길이 20cm)에 충전시키고, 이 지지체의 표면에 공유결합제인 glutaraldehyde로 urease를 고정화시켜서 제작하였다. 연속${\cdot}$자동화장치는 효소반응기, 기체투석기 및 지시전극인 관형 PVC-nonactin막 암모늄 이온 선택성 전극을 차례로 연결하여 만들었다. 이 장치를 써서 요소를 정량할 때 감응특성은 다음과 같다. 곧 직선감응 농도범위는 $5.5{\times}10^{-6}$~$2.4{\times}10^{-3}M$, 감응기울기는 57.8 mV/decade, 검출한계는 $1.5{\times}10^{-6}M$, 효소반응기의 전환백분율은 80.8%이었다. 효소반응기의 최적 완충용액은 0.01M Tris-HCl 완충용액(pH 7.0∼7.8)과 0.01M 인산염 완충용액(pH 6.9∼7.5)이었고, 수명은 150일 정도였다. 또한 다른 생리활성물질의 방해는 없었다.