• Title/Summary/Keyword: continuous band

Search Result 283, Processing Time 0.023 seconds

Analysis on Topographic Normalization Methods for 2019 Gangneung-East Sea Wildfire Area Using PlanetScope Imagery (2019 강릉-동해 산불 피해 지역에 대한 PlanetScope 영상을 이용한 지형 정규화 기법 분석)

  • Chung, Minkyung;Kim, Yongil
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_1
    • /
    • pp.179-197
    • /
    • 2020
  • Topographic normalization reduces the terrain effects on reflectance by adjusting the brightness values of the image pixels to be equal if the pixels cover the same land-cover. Topographic effects are induced by the imaging conditions and tend to be large in high mountainousregions. Therefore, image analysis on mountainous terrain such as estimation of wildfire damage assessment requires appropriate topographic normalization techniques to yield accurate image processing results. However, most of the previous studies focused on the evaluation of topographic normalization on satellite images with moderate-low spatial resolution. Thus, the alleviation of topographic effects on multi-temporal high-resolution images was not dealt enough. In this study, the evaluation of terrain normalization was performed for each band to select the optimal technical combinations for rapid and accurate wildfire damage assessment using PlanetScope images. PlanetScope has considerable potential in the disaster management field as it satisfies the rapid image acquisition by providing the 3 m resolution daily image with global coverage. For comparison of topographic normalization techniques, seven widely used methods were employed on both pre-fire and post-fire images. The analysis on bi-temporal images suggests the optimal combination of techniques which can be applied on images with different land-cover composition. Then, the vegetation index was calculated from the images after the topographic normalization with the proposed method. The wildfire damage detection results were obtained by thresholding the index and showed improvementsin detection accuracy for both object-based and pixel-based image analysis. In addition, the burn severity map was constructed to verify the effects oftopographic correction on a continuous distribution of brightness values.

Effects an Acoustical Equipment on the Luring of Fish School (음향집어기의 집어 효과)

  • 장선덕
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.22 no.4
    • /
    • pp.75-82
    • /
    • 1986
  • A field experiment was carried out to clarify the effect of underwater sound on the luring of fish school. The effects of. the acoustic emission on the luring of fish school were checked actually at a set net fishing site in Namhae using a commercial acoustic equipment, Dairyo-8. An emitting system of sound was designed by the authors, and the ambient noise, the sound pressure level and the reaction of fish school were measured in the set net. 1. The predominent frequency band of ambient noise was 150Hz-400Hz,.and the sound emitted was 400Hz-100Hz. The sound pressure level of ambient noise in set net was higher at the landing part, and lower at the playgrond, the gate of court and "the enterance of inclined "passage. The ambient noise was increased with the time elapse-d at the stage of hauling net, but :it was decreased suddenly at the final stage due probably to the decrease of the swimming speed of the fish school. 2. The results of the observation and the recording paper of echo sounder indicate that the effect of emitting sound in the bag net of set net was remarkable for the luring of fish school in the early stage, but decreased after 30 minutes. The reaction of fish school is more sensitiv2 to the sound pressure level than the time intervals between the emission and the pause. For the purpos~ of practical use, it is nesessary to confirm what kind of sound pressure level is the best for the luring of fish school. 3. In response to the acoustic equipment(Dairyo-8), fish school started to swarm 20 minutes after the sound emission and scattered when the sound paused. As the emitting pattern of the acoustic equiment, the three seconds of emission after one second of pause was more effective than the continuous emission at the set net fishing ground. Catch of the fish(s during th~ sound ernissio:l at the gate of court was three to five times more than that of no emission.

  • PDF

5GHz Wi-Fi Design and Analysis for Vehicle Network Utilization (차량용 네트워크 활용을 위한 5GHz WiFi 설계 및 분석)

  • Yu, Hwan-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.18-25
    • /
    • 2020
  • With the development of water internet technology, data communication between objects is expanding. Research related to data communication technology between vehicles that incorporates related technologies into vehicles has been actively conducted. For data communication between mobile terminals, data stability, reliability, and real-time performance must be guaranteed. The 5 GHz Wi-Fi band, which is advantageous in bandwidth, communications speed, and wireless saturation of the wireless network, was selected as the data communications network between vehicles. This study analyzes how to design and implement a 5 GHz Wi-Fi network in a vehicle network. Considering the characteristics of the mobile communication terminal device, a continuous variable communications structure is proposed to enable high-speed data switching. We simplify the access point access procedure to reduce the latency between wireless terminals. By limiting the Transmission Control Protocol Internet Protocol (TCP/IP)-based Dynamic Host Configuration Protocol (DHCP) server function and implementing it in a broadcast transmission protocol method, communication delay between terminal devices is improved. Compared to the general commercial Wi-Fi communication method, the connection operation and response speed have been improved by five seconds or more. Utilizing this method can be applied to various types of event data communication between vehicles. It can also be extended to wireless data-based intelligent road networks and systems for autonomous driving.

In Vitro and In Vivo Agreement of Microwave Radio-Thermometer and Needle Probe Thermometer During Therapeutic Ultrasound (초음파 가열 시 In Vitro 및 In Vivo에서 Microwave Radio-Thermometer와 탐침온도계의 일치도)

  • Lee, Su-Young;Cho, Sang-Hyun;Yi, Chung-Hwi;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.15-27
    • /
    • 2003
  • Therapeutic ultrasound is commonly applied for deep heating in physical therapy setting. However, it is difficult to determine the exact application dosage and to confirm the immediate heating effect. Microwave Radio-Thermometer (MRT) can measure the temperature by the electromagnetic energy in the microwave region of the object that emits above absolute zero temperature. MRT was used for early diagnosis of breast cancer since it was not harmful, non-invasive, and non-ionizing to the human body. The purposes of this study were to investigate how accurately 1.1 GHz RTM (RES Ltd. Russia) measures the change of average temperature in the tissue, and to determine the depth of temperature change measurement. Therapeutic ultrasound was applied (continuous wave for 5 minutes, 1 MHz, intensity of 1.5 $W/cm^2$ [in vitro] and 1.0 $W/cm^2$ [in vivo]) in four different conditions: (1) 30 cases of in vitro specimen of pork, (2) 30 cases of in vitro specimen of pork ankle joint, (3) 10 cases of in vivo canine thigh, and (4) 30 cases of in vivo human body. Intraclass Correlation Coeffients (ICC[3,1]) between average needle probe thermometer below surface and MRT temperature was revealed as followed: (1) Before ultrasound application ICCs ranges above .8 in specimen of pork (15 mm underneath the skin) and above .82 in specimen of pork ankle joint (10~30 mm underneath the skin). (2) After ultrasound application ICCs ranges above .7 in both specimens of pork and pork ankle joint. (3) Before ultrasound application ICCs ranges above .8 in canine thigh (20 mm underneath the skin). (4) After ultrasound application ICCs ranges above .82 in canine thigh. The temperature of the human body increased significantly with the mean of $15^{\circ}C$ in muscle tissue and with the mean of $3.5^{\circ}C$ in joint (p<.00). It was revealed that the average depth of temperature measurement of the tissue by MRT was in between 10 and 35 mm, and determined that the proper temperature measurement band was $36.5{\sim}37.0^{\circ}C$.

  • PDF

Ship Detection Based on KOMPSAT-5 SLC Image and AIS Data (KOMPSAT-5 SLC 영상과 AIS 데이터에 기반한 선박탐지)

  • Kim, Donghan;Lee, Yoon-Kyung;Kim, Sang-Wan
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_2
    • /
    • pp.365-377
    • /
    • 2020
  • Continuous monitoring and immediate response is essential to protect the national maritime territory and maritime resources from the activities of illegal ships. Synthetic Aperture Radar (SAR) images with a wide range of images are effective for maritime surveillance asthe weather and day-night conditions rarely affect to image acquisition. However, an effective ship detection is not easy due to the huge data size of SAR images and various characteristics such as the speckle noise. In this study, the Human Visual Attention System (HVAS) algorithm was applied to KOMPSAT-5 to extract the initial targets, and the SAR-Split algorithm depending on the imaging modes was used to remove false alarms. The detected targets were finally selected by the Constant False Alarm Rate (CFAR) algorithm and matched with the ship's Automatic Identification System (AIS) information. Overall, the detected targets were well matched with AIS data, but some false alarms by ship wakes were observed. The detection rate was about 80% in ES mode and about 64% in ST mode. It is expected that the developed ship detection algorithm will contribute to the construction of a wide area maritime surveillance network.

Optical Properties of Photoferroelectic Semiconductors IV.(Optical Properties of SbSI:V, SbSeI:V, BiSI:V, BiSeI:V, SbSI:Cr, SbSeI:Cr, BiSI:Cr, BiSeI:Cr, SbSI:Ni, SbSeI:Ni, BiSI:Ni and BiSeI:Ni Single Crystals) (Photoferroelectric 반도체의 광학적 특성 연구 IV. (SbSI:V, SbSeI:V, BiSI:V, BiSeI:V, SbSI:Cr, SbSeI:Cr, BiSI:Cr, BiSeI:Cr, SbSI:Ni, SbSeI:Ni, BiSI:Ni 및 BiSeI:Ni 단결정의 광학적 특성에 관한 연구))

  • Oh, Seok-Kyun;Hyun, Seung-Cheol;Yun, Sang-Hyun;Kim, Wha-Tek;Kim, Hyung-Gon;Choe, Sung-Hyu;Yoon, Chang-Sun;Kwun, Sook-Il
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.2
    • /
    • pp.236-245
    • /
    • 1993
  • Single crystals, SbSI : V, SbSeI : V, BiSI : V, BiSeI : V, SbSI : Cr, SbSeI : Cr, BiSI : Cr, BiSeI : Cr, SbSI : Ni, SbSeI : Ni, BiSI : Ni, and BiSeI : Ni were grown by the vertical Bridgman method. It is found that the grown single crystals have an orthorhombic structure and the indirect optical transitions. The temperature dependence of energy gap shows the two reflection point related with the phase transitions and is well fitted with Varshni equation in the continuous region. The optical absorption peaks due to the doped impurities (V, Cr and Ni) are respectively attributed to the electron transitions between the split energy levels of $V^{+2}$, $Cr^{+2}$ and $Ni^{+2}$ ions sited at $T_d$ symmetry of the host lattice.

  • PDF

Clonal Dissemination of Multidrug Resistant Acinetobacter baumannii Isolates Harboring blaOXA-23 at One University Hospital in Daejeon, Korea (대전지역 소재 대학병원에 blaOXA-23 유전자를 가지고 있는 다제내성 Acinetobacter baumannii의 확산)

  • Sung, Ji Youn
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.94-101
    • /
    • 2016
  • Acinetobacter species isolates are important opportunistic pathogens and commonly implicated in nosocomial infections. The therapeutic options for treatment of the bacterial infections are limited because the bacteria isolates are usually multidrug resistant (MDR). In the current study, we investigated various carbapenemase genes in 68 Acinetobacter species isolates. Antimicrobial susceptibilities were tested using the disk diffusion method. Screening of carbapenemase genes was performed via multiplex PCR. In addition, PCR and DNA sequencing were used to identify the carbapenemase genes. Repetitive extragenic palindromic-PCR (REP-PCR) was also performed to assess the clonality of isolates. In our study, A. baumannii isolates were highly resistant to all agents tested while all non-A. baumannii isolates were susceptible to all agents tested, with the exception of aztreonam and cefotaxime. All 51 A. baumannii isolates contained the $bla_{OXA-51}$ gene and 37 (72.5%) isolates also harbored the $bla_{OXA-23}$ gene. In addition, 39 MDR A. baumannii isolates were identified in our study and 37 isolates contained the $bla_{OXA-23}$ gene. The 37 MDR strains harboring $bla_{OXA-23}$ showed type I (n=22) or type II (n=15) banding patterns on their REP-PCR profiles. Our results suggest clonal relation and horizontal spreading of MDR A. baumannii isolates containing the $bla_{OXA-23}$ gene at the hospital located in Daejeon. Continuous investigation of antimicrobial resistant determinants and monitoring emergence and dissemination of MDR isolates is required to prevent and control infection and colonization of MDR A. baumannii isolates.

The Radiological Findings of the Catheters Inserted 10cm Cephaladly in Epidural Space (경막외강내 두측으로 10cm 삽입한 카테터의 X-선상 소견)

  • Chung, So-Young;Lee, Hyo-Keun;Chae, Jin-Ho;Lee, Chul-Seung;Lee, Chul;Kim, Chan;Kim, Soon-Yul
    • The Korean Journal of Pain
    • /
    • v.8 no.2
    • /
    • pp.298-303
    • /
    • 1995
  • We have inserted epidural catheter for single or continuous injection of a drug for epidural analgesia. It is important to localize the tip of epidural catheter in appropriate site to acquire the most effective analgesia. In epidural block, we observed course and location of the tip of epidural catheter. Subject: 70 patients were divided into group I(non-injection of saline group during catheter insertion) and group II(injection group during catheter insertion). Group I included cervical(n=20), thoracic(n=10), and lumbar(n=20) epidural group. Group II, cervical(n=10), and lumbar(n=10) epidural group. Method: 19G FlexTip $Plus^{TM}$ Epidural Catheter ($Arrow^{(R)}$) was inserted 10cm cephaladly in epidural space with(group II) or without(group I) saline flushing. We observed course and location of the tip of epidural catheter by C-arm image intensifier during injection of contrast media ($Omnipaque^{(R)}$). Result: In group I, the number of tips of epidural catheters located within 2 cm from inserted site were: cervical 14/20(70%), thoracic 2/10(20%). lumbar 16/20(80%). In thoracic epidural blocks, tips of epidural catheters were more cephaladly located than with cervical and lumbar epidural blocks. With cervical epidural blocks, the number of tips of epidural catheters located within 2 cm from insertion site were less in group II than group I (20% vs. 70%). But no significant differences were noted between group I and group II with lumbar epidural block(90% vs. 80%). The number of tips of epidural catheters located around a predicted site were: cervical 2/20(10%), thoracic 4/10(40%), lumbar 0/20(0%) in group I, and cervical 2/10(20%), lumbar 1/10(10%) in group II. Conclusion: It was impossible to predict the exact location of tips of epidural catheters by measuring the inserted length without epidurogram. With many cases, tips of epidural catheters were located around the insertion site in lumbar epidural blocks, and in some cases around the predicted site in thoracic epidural blocks. The results suggests that epidural block should be done at a point near the required band of analgesia.

  • PDF

A Study on Geoid Model Development Method in Philipphines (필리핀 지오이드모델의 개발방안 연구)

  • Lee, Suk-Bae;Pena, Bonifasio Dela
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.6
    • /
    • pp.699-710
    • /
    • 2009
  • If a country has her geoid model, it could be determine accurate orthometric height because the geoid model could provide continuous equi-gravity potential surface. And it is possible to improve the coordinates accuracy of national control points through geodetic network adjustment considering geoidal heights. This study aims to find the best way to develop geoid model in Philippines which have similar topographic conditions as like Malaysia and Indonesia in Eastsouth asia. So, in this study, it is surveyed the general theories of geoid determination and development cases of geoid model in Asia and it is computed that the geoidal heights and gravity anomalies by spherical harmonic analysis using EGM2008, the latest earth geopotential model. The results show that first, the development of gravimetric geoid model based on airborne gravimetry is needed and second, about 200 GPS surveying data at national benchmark is needed. It is concluded that it is the most reasonable way to develop the hybrid geoid model through fitting geometric geoid by GPS/leveling data to gravimetric geoid. Also, it is proposed that four band spherical Fast fourier transformation(FFT) method for evaluation of Stokes integration and remove and restore technique using EGM2008 and SRTM for calculation of gravimetric geoid model and least square collocation algorithm for calculation of hybrid geoid model.

User Experience Analysis of Smart bands (스마트 밴드에 대한 사용자경험 분석)

  • Kim, Gun-A;Kim, Suk-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.99-105
    • /
    • 2017
  • With the advancement of Information and Communication Technology (ICT), the wearable-device industry is growing at a rapid pace in line with the hyper-connected society of people-to-things and things-to-things network connections. International Data Corporation (IDC), a market research institute, estimates that the wearable-device industry will grow rapidly by 2020, despite not yet attracting a popular response. This study investigates the trend of the wearable-device industry and draws implications for product and service development through user experience analysis. The subject of analysis was smart bands and the data generated from product review were collected and analyzed. As a result, user experience could extract utility, usability, aesthetics, value, and reliability, and polarity was analysed and visualized in the extracted data. The study results reveal that current wearable-devices are expensive, that users cannot receive useful information from the long-term viewpoint since the analysis of accumulated data remains focused on functional development, and that they are recognized as a fashion item or an accessory. These factors hinder the continuous usage, motivation and market spread of the product. In a future follow-up study, we will conduct a comparative study on bands and watches by analyzing the second smart watch.