The Piezoelectric and Dielectric Properties of PZT-PMN Ceramics (PZT-PMN 압전 세라믹의 압전 및 유전 특성)

  • Lee, J.S.;Lee, Y.H.;Hong, J.K.;Jeong, S.H.;Chai, H.I.;Lim, K.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.131-134
    • /
    • 2001
  • In this paper, the piezoelectric and dielectric properties as a function of x and a in $aPbZr_xTi_{1-x}O_3-(1-a)Pb(Mn_{1/3}Nb_{2/3})O_3$ + ywt%MgO is investigated. As a results, when a is 0.95 and x is 0.505, electromechanical coupling factor$(k_p)$, permittivity${\varepsilon}_33^T/{\varepsilon}_0$, piezoelectric strain constant$(d_{33})$ and mechanical quality factor$(Q_m)$ are 58 %, 1520, 272 pC/N and 1550, respectively. From XRD analysis, when x is 0.505, it is MPB which present rhombohedral and tetragonal phase in same quantity. Also, From SEM observation, when sintering temperature is $1150^{\circ}C$, grain size is about $2\;{\mu}m$. As a results added MgO dopant in the ternary piezoelectric ceramic, when MgO content is 0.1 wt%, $k_p$ increases to 63[%].

  • PDF

Dehydration of Alcohol Solutions Through Crosslinked Chitosan Composite Membranes II. Dehydration of Ethanol Solution Through Modified Chitosan Composite Membranes (가교키토산 복합막을 통한 알콜수용액의 탈수 II. 변성 키토산 복합막을 통한 에탄올의 탈수)

  • 이영무;남상용;유제강;류경옥
    • Membrane Journal
    • /
    • v.6 no.4
    • /
    • pp.242-249
    • /
    • 1996
  • To improve pervaporation performance of water/ethanol mixtures, chitosan/poly(vinyl alcohol) blended and phosphorylated chitosan composite membranes were prepared. Chitosan/poly(vinyl alcohol) blends were prepared with various blend ratios and then crosslinked with glutaraldehyde by two methods. With increasing crosslinking agent content and crosslinking times separation factor increased and permeate flux decreased. Separation factor of the membrane which contains glutaraldehyde as a crosslinking agent was higher than that of the membrane surface crosslinked. Phosphorylated chitosan was prepared with various reaction times and composite membrane was prepared. As reaction times increased, the separation factor increased with high affinity for water.

  • PDF

Development of the Transition Shock Scale for Newly Graduated Nurses (신규간호사의 전환충격 측정도구 개발)

  • Kim, Eun-Young;Yeo, Jung Hee;Yi, Kyeong Im
    • Journal of Korean Academy of Nursing
    • /
    • v.47 no.5
    • /
    • pp.589-599
    • /
    • 2017
  • Purpose: The purpose of this study was to develop a scale to assess the transition shock experienced by newly graduated nurses, and test the validity and reliability of the scale. Methods: The initial items were identified through a review of literature and in-depth interviews with nine newly graduated nurses. Content validation of the items was evaluated by five nurse professors and three nurses. Participants were 269 newly graduated nurses who worked at six acute care hospitals in Busan, Ulsan, and Yangsan, South Korea. Data were analyzed using item analysis, exploratory and confirmatory factor analysis, criterion related validity, and internal consistency. Results: The final scale consisted of 18 items and six factors (conflict between theory and practice, overwhelming workload, loss of social support, shrinking relationship with co-workers, confusion in professional nursing values, and incongruity in work and personal life), which explained 71.3% of the total variance. The six subscale model was validated by confirmatory factor analysis. Cronbach's alpha for the total items was. 89. Convergent validity was evaluated by analyzing total correlation with burnout (r=.71, p<.001) and turnover intention (t=5.84, p<.001). Conclusion: This scale can be used in the development of nursing interventions to reduce the transition shock experienced by newly graduated nurses.

Development and Validation of the New Version of Spirituality Assessment Scale (영성 측정도구 개발과 평가)

  • Ko, Il-Sun;Choi, Soyoung;Kim, Jin Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.50 no.1
    • /
    • pp.132-146
    • /
    • 2020
  • Purpose: The purpose of this study was to develop a new version of Spirituality Assessment Scale (N-SAS) and verify its reliability and validity. Methods: The total of 59 preliminary items for the N-SAS were selected through a literature review, two rounds of experts' content validation, cognitive interviews, and pre-tests. Verification of its reliability and validity was divided into two phases. In Phase I, questionnaires were collected from 219 adults. Reliability was tested using Cronbach's alpha, validity with item analysis, and exploratory factor analysis. In Phase II, questionnaires developed based on the results of Phase I were collected from 225 adults. Reliability was tested using Cronbach's alpha, validity with confirmatory factor analysis, and criterion validity. Results: The final version of the N-SAS comprised two dimensions (vertical and horizontal), four domains (relationship with God; meaning of life and self-integration; self-transcendence; and relationship with others, neighborhoods, and nature), and 44 items were identified. Total Cronbach's α was .97; those of each subscale ranged from .79 to .98. N-SAS scores were positively correlated with the scores of Howden's Spiritual Assessment Scale (r=.81, p<.001). Conclusion: Findings suggest that the N-SAS can be used to measure spirituality in adults. The use of N-SAS is expected to facilitate perceiving patient's spiritual needs and providing spiritual care.

Dielectric and Piezoelectric Characteristics of the (Na,K)(Nb,Sb)O3 Ceramics as a Function of Na Excess Addition (Na 과잉 첨가에 따른 (Na, K)(Nb, Sb)O3 세라믹스의 유전 및 압전 특성)

  • Seo, Bueong-Ho;Lee, Kab-Soo;Yoo, Ju-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.4
    • /
    • pp.285-289
    • /
    • 2011
  • In this study, lead-free $(K_{0.5}Na_{0.5+X})(Nb_{0.96}Sb_{0.04})O_3+0.2mol%La_2O_3+1.2mol%$ $K_4CuNb_8O_{23}$ (X= 0~0.025) ceramics were fabricated by normal sintering method at $1060^{\circ}C$ for 5 h. Microstructures, piezoelectric and dielectric properties of specimens were investigated with special emphasis in the influence of Na excess addition. The grain size of specimen was slightly decreased with increasing Na content. In the 2 [mol%] Na excess addition of NKNS ceramics, density, electromechanical coupling factor, piezoelectric constant and electromechancal quality factor of specimen were found to reach the optimum values of 4.25 [$g/cm^3$], 0.4357, 154.43 [pC/N] and 580, respectively.

The Analysis of Risk Factor Management Programs for Patients with Coronary Artery Disease (관상동맥질환자를 위한 위험요인관리 프로그램 분석)

  • Bang, So-Youn;Park, Mi-Young
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.16 no.1
    • /
    • pp.27-36
    • /
    • 2013
  • Purpose: This study was performed to analyse the trends of risk factor management programs for patients with coronary artery disease. Methods: Using PubMed, 35 intervention studies related to risk factor management programs among randomized controlled trials searched with the key words of coronary artery disease and coronary heart disease. Collected studies were analysed according to the characteristics of studies and participants, method and content of intervention, and outcome indicator and its effects. Results: The mean period of intervention was $28.7{\pm}26.8$ weeks, the mean frequency was $3.0{\pm}2.0$ times per week, and the duration of one session was below 60 minuets in 65.8% of the reviewed studies. The interventions were counselling, exercise, education, and cognitive behavior therapy. Counselling was applied most frequently in previous studies. The outcomes of intervention had been measured with anthropometric, physical, physiological, psychological, behavioral, and cognitive aspects, but the effect of the intervention was inconsistent among the studies. Conclusion: Based on the results of this study, systematic and comprehensive cardiac rehabilitation program consisted of counselling, exercise, and education should be developed and performed for health management and relapse prevention of patients with coronary artery disease.

On the effect of temperature on the threshold stress intensity factor of delayed hydride cracking in light water reactor fuel cladding

  • Alvarez Holston, Anna-Maria;Stjarnsater, Johan
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.663-667
    • /
    • 2017
  • Delayed hydride cracking (DHC) was first observed in pressure tubes in Canadian CANDU reactors. In light water reactors, DHC was not observed until the late 1990s in high-burnup boiling water reactor (BWR) fuel cladding. In recent years, the focus on DHC has resurfaced in light of the increased interest in the cladding integrity during interim conditions. In principle, all spent fuel in the wet pools has sufficient hydrogen content for DHC to operate below $300^{\circ}C$. It is therefore of importance to establish the critical parameters for DHC to operate. This work studies the threshold stress intensity factor ($K_{IH}$) to initiate DHC as a function of temperature in Zry-4 for temperatures between $227^{\circ}C$ and $315^{\circ}C$. The experimental technique used in this study was the pin-loading testing technique. To determine the $K_{IH}$, an unloading method was used where the load was successively reduced in a stepwise manner until no cracking was observed during 24 hours. The results showed that there was moderate temperature behavior at lower temperatures. Around $300^{\circ}C$, there was a sharp increase in $K_{IH}$ indicating the upper temperature limit for DHC. The value for $K_{IH}$ at $227^{\circ}C$ was determined to be $2.6{\pm}0.3MPa$ ${\surd}$m.

A Field Application Case of Direct Ice Slurry Transporting System for District Cooling (지역냉방용 직접순환식 아이스슬러리 시스템의 현장적용 사례)

  • Yoo, Ho-Seon;Lee, Sang-Hoon;Lee, Yoon-Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.9
    • /
    • pp.496-504
    • /
    • 2009
  • In order to investigate the feasibility of a direct ice slurry transporting system for the purpose of district cooling, a case study of field application is performed. The research aims include the field measurement of ice packing factor, the performance of coldness delivery, and the branching characteristics of ice slurry. Two representative types of pipe branch are dealt with in this work. For the slurry flow with ice volume fraction of 0.16 or less, the pipe blocking due to aggregation is not observed. Based on the time-wise variation of temperature in the storage tank, a calculating method of ice packing factor is newly developed, which seems to be useful when the brine concentration is unknown. It is confirmed that the mass flow rate of ice slurry per unit cooling load is markedly reduced with increasing the ice content. The pumping power also decreases, but remains unchanged for high ice fractions. The distribution of ice particle before and after branching shows a good uniformity within the range of 5% difference, but yields a unique trend depending on the flow rate.

Numerical and random simulation procedure for preliminary local site characterization and site factor assessing

  • Beneldjouzi, Mohamed;Laouami, Nasser;Slimani, Abdennasser
    • Earthquakes and Structures
    • /
    • v.13 no.1
    • /
    • pp.79-87
    • /
    • 2017
  • Seismic analysis of local site conditions is fundamental for a reliable site seismic hazard assessment. It plays a major role in mitigation of seismic damage potential through the prediction of surface ground motion in terms of amplitude, frequency content and duration. Such analysis requires the determination of the transfer function, which is a simple tool for characterizing a soil profile by estimating its vibration frequencies and its amplification potential. In this study, numerical simulations are carried out and are then combined with a statistical study to allow the characterization of design sites classified by the Algerian Building Seismic Code (RPA99, ver 2003), by average transfer functions. The mean transfer functions are thereafter used to compute RPA99 average site factors. In this regard, coming up seismic fields are simulated based on Power Spectral Density Functions (PSDF) defined at the rock basement. Results are also used to compute average site factor where, actual and synthetic time histories are introduced. In absence of measurement data, it is found that the proposed approach can be used for a better soil characterization.

Magnetic Field Calculation and Multi-objective Optimization of Axial Flux Permanent Magnet Generator with Coreless Stator Windings

  • Zhu, Jun;Li, Shaolong;Song, Dandan;Han, Qiaoli;Li, guanghua
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1586-1595
    • /
    • 2018
  • For the problem that the complexity of 3-D modeling and multi parameter optimization, as well as the uncertainty of the winding factor of axial flux permanent magnet generator with coreless windings. The complex 3-D model was simplified into 2-D analytic model, and an analytical formula for the winding factor that adapting different coreless stator winding is proposed in this paper. The analytical solution for air-gap magnetic fields, no-load back EMF, electromagnetic torque, and efficiency are calculated by using this method. The multiple objective and multivariable optimization of the maximum fundamental and the minimum harmonic content of back EMF are performed by using response surface methodology. The proposed optimum design method was applied to make a generator. The generator was tested and the calculated results are compared with the proposed method, which show good agreements.