• 제목/요약/키워드: contamination sensitivity

검색결과 134건 처리시간 0.023초

해석적 Bode 방법에 의한 직접구동형서보밸브의 고전적 제어기 설계 (Classical Controller Design of Direct Drive Servo Valve Using Analytical Bode Method)

  • 이성래;최현영;문의준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.507-514
    • /
    • 2001
  • Direct drive servovalve(DDV) is a kind of one-stage valve since the rotary motion of DC motor is directly transferred to the linear motion of valve spool through the link. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the classical controller is designed using the analytical Bode method.

  • PDF

0가 철분을 이용한 유기염소화합물의 환원적 탈염소화 (Reductive Dechlorination of Chlorinated Oraganic Compounds Using Zero-Valent Iron)

  • 이창수;배우근
    • 한국산업융합학회 논문집
    • /
    • 제4권4호
    • /
    • pp.427-432
    • /
    • 2001
  • The purpose of study is to examine the sensitivity of the rate of degradation to initial TCE concentration and iron concentration in the solution. The batch tests were executed to assess the degradation rate at varying initial conditions. First order rate constants($k_a$) were more rapid with the lower initial TCE concentration, Howere the correleation was not always linear between $k_a$ and initial TCE concentration. $k_a$ was proportionally increased as the increasing surface area. It implied that the effective reactive surface area acted as the limiting factor on the reductive dechlorination of TCE by iron.

  • PDF

컴플렉스법에 의한 직접구동형서보밸브의 진상-지상 제어기 설계 (Lead-Lag Controller Design of Direct Drive Servo Valve Using Complex Method)

  • 이성래
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1590-1595
    • /
    • 2003
  • Direct drive servovalve(DDV) is a kind of one-stage valve since the rotary motion of DC motor is directly transferred to the linear motion of valve spool through the link. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the lead-lag controller is designed using the complex method that is one kind of constrained direct search method.

  • PDF

컴플렉스법에 의한 직접구동형서보밸브의 진상-지상 제어기 설계 (Lead-Lag Controller Design of Direct Drive Servo Valve Using Complex Method)

  • 이성래
    • 대한기계학회논문집A
    • /
    • 제28권11호
    • /
    • pp.1719-1726
    • /
    • 2004
  • Direct drive servovalve(DDV) is a kind of one-stage valve because the main spool valve is directly driven by the DC motor. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the lead-lag controller is designed using the complex method that is one kind of constrained direct search method.

해석적 Bode 방법에 의한 직접구동형서보밸브의 고전적 제어기 설계 (Classical Controller Design of Direct Drive Servo Valve Using Analytical Bode Method)

  • 이성래;최현영;문의준
    • 대한기계학회논문집A
    • /
    • 제26권4호
    • /
    • pp.754-763
    • /
    • 2002
  • Direct drive servovalve(DDV) is a kind of one-stage valve since the rotary motion of DC motor is directly transferred to the linear motion of valve spool through the link. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the classical controller is designed using the analytical Bode method.

내장형 정전용량 근접 센서를 이용한 다중 팁 기반 패턴 인쇄 (Arrayed Tip based Pattern Lithography with Built-in Capacitive Proximal Leveling Sensor)

  • 한윤수
    • 한국표면공학회지
    • /
    • 제52권5호
    • /
    • pp.239-245
    • /
    • 2019
  • To increase the throughput of tip-based nanolithography (TBN), one approach is to use a large array of such tips working in parallel. It is important to maintain co-planarity between the tip array and the writing surface. A slight misalignment can cause large discrepancies of contact force and feature sizes. We report a capacitive proximity sensor built-in with the TBN array for leveling an arrayed polymer pen array. The device allows alignment between an array of writing tips and the writing substrate without contact and contamination. The angular sensitivity of the sensor is $0.05^{\circ}$ for an array with maximum tip-to-tip separation of 100 mm.

Presence of Cryptosporidium spp. and Giardia duodenalis in Drinking Water Samples in the North of Portugal

  • Almeida, Andre;Moreira, Maria Joao;Soares, Sonia;Delgado, Maria de Lurdes;Figueiredo, Joao;Silva, Elisabete;Castro, Antonio;Da Cosa, Jose Manuel Correida
    • Parasites, Hosts and Diseases
    • /
    • 제48권1호
    • /
    • pp.43-48
    • /
    • 2010
  • Cryptosporidium and Giardia are 2 protozoan parasites responsible for waterborne diseases outbreaks worldwide. In order to assess the prevalence of these protozoans in drinking water samples in the northern part of Portugal and the risk of human infection, we have established a long term program aiming at pinpointing the sources of surface water, drinking water, and environmental contamination, working with the water-supply industry. Total 43 sources of drinking water samples were selected, and a total of 167 samples were analyzed using the Method 1623. Sensitivity assays regarding the genetic characterization by PCR and sequencing of the genes, 18S SSU rRNA, for Cryptosporidium spp. and $\beta$, -giardin for G. duodenalis were set in the laboratory. According to the defined criteria, molecular analysis was performed over 4 samples. Environmental stages of the protozoa were detected in 25.7% (43 out of 167) of the water samples, 8.4% (14 out of 167) with cysts of Giardia, 10.2% (17 out of 167) with oocysts of Cryptosporidium and 7.2% (12 out of 167) for both species. The mean concentrations were 0.1-12.7 oocysts of Cryptosporidium spp. per 10 L and 0.1-108.3 cysts of Giardia duodenalis per 10 L. Our results suggest that the efficiency in drinking water plants must be ameliorated in their efficiency in reducing the levels of contamination. We suggest the implementation of systematic monitoring programs for both protozoa. To authors' knowledge, this is the first report evaluating the concentration of environmental stages of Cryptosporidium and Giardia in drinking water samples in the northern part of Portugal.

돼지 희석정액의 세균오염도 및 유효 항생제 선발 (Bacterial contaminants in extended boar semen and selection of effective antimicrobials)

  • 김하영;변재원;신동호;김형순;윤하정;박최규;이오수;정병열
    • 대한수의학회지
    • /
    • 제50권2호
    • /
    • pp.125-131
    • /
    • 2010
  • Bacterial contamination is an unavoidable finding of the semen collection process in boar and can lead in deleterious effects on semen quality and longevity if left uncontrolled. The purpose of this study is to identify the bacteria in extended boar semen and to select the effective antimicrobials to control of the contaminants. Of 116 extended boar semen samples submitted from eight AI centers in Korea, 39 (33.6%) samples were positive for bacterial contamination. Among 39 contaminated semen, most of them (84.6%) were contaminated with one or two bacterial species and there was no significant difference between two age groups $(\leq\;24\;and\;>\;24\;month\;old).$ Stenotrophomonas maltophilia (n = 18) was the most predominant bacterium followed by Elizabethkingia meningoseptica (n = 12), Sphingomonas paucimobilis (n = 12), Myroides spp. (n = 5), Ochrobactrum anthropi (n = 3), and so on. Enrofloxacin (72.9%), florfenicol (72.9%), bacitracin (49.2%) and tylosin (49.2%) showed higher sensitivity compared with penicillin (13.6%) or aminoglycosides (6.8%-18.6%). Brucella spp., Leptospira spp., Mycoplasma hyopneumoniae, Mycoplasma hyorhinis, Mycobacterium tuberculosis complex were not detected in semen by PCR.

Simple and rapid colorimetric detection of African swine fever virus by loop-mediated isothermal amplification assay using a hydroxynaphthol blue metal indicator

  • Park, Ji-Hoon;Kim, Hye-Ryung;Chae, Ha-Kyung;Park, Jonghyun;Jeon, Bo-Young;Lyoo, Young S.;Park, Choi-Kyu
    • 한국동물위생학회지
    • /
    • 제45권1호
    • /
    • pp.19-30
    • /
    • 2022
  • In this study, a simple loop-mediated isothermal amplification (LAMP) combined with visual detection method (vLAMP) assay was developed for the rapid and specific detection of African swine fever virus (ASFV), overcoming the shortcomings of previously described LAMP assays that require additional detection steps or pose a cross-contamination risk. The assay results can be directly detected by the naked eye using hydroxynaphthol blue after incubation for 40 min at 62℃. The assay specifically amplified ASFV DNA and no other viral nucleic acids. The limit of detection of the assay was <50 DNA copies/reaction, which was ten times more sensitive than conventional polymerase chain reaction (cPCR) and comparable to real-time PCR (qPCR). For clinical evaluation, the ASFV detection rate of vLAMP was higher than cPCR and comparable to OIE-recommended qPCR, showing 100% concordance, with a κ value (95% confidence interval) of 1 (1.00~1.00). Considering the advantages of high sensitivity and specificity, no possibility for cross-contamination, and being able to be used as low-cost equipment, the developed vLAMP assay will be a valuable tool for detecting ASFV from clinical samples, even in resource-limited laboratories.

화장품에 함유된 미량의 프탈레이트 함량을 정확히 분석하기 위한 가스크로마토그래피-질량분석 시험법 및 그 시험법의 유효성 (Accurate Analysis of Trace Phthalates and Method Validation in Cosmetics using Gas Chromatography with Mass Spectrometric Detection)

  • 김민기;정혜진;조준철
    • 대한화장품학회지
    • /
    • 제38권1호
    • /
    • pp.33-41
    • /
    • 2012
  • 네일락카와 헤어스프레이 같은 화장품에 존재하는 미량의 프탈레이트를 정량분석하기 위하여, 가스크로마토그래피와 질량분석기를 사용한 효과적이면서 환경친화적인 분석방법을 개발하였다. 이들 화장품들은 다량의 유기용매를 함유되어 프탈레이트를 분석하기 위하여 널리 사용되는 시료의 클린업 방법이 적합하지 않았다. 더군다나 미량의 프탈레이트 분석시에는 실험과정 중에서의 오염으로 인해 실제보다 높은 분석값을 산출하게 되는 경우가 매우 많다. 이에 정확한 함량분석 및 이차오염을 방지하기 위해 유기용매를 사용하여 시료를 직접 희석하는 시료 전처리를 적용하였다. 이 분석방법은 높은 정확성, 분석감도, 그리고 시료전처리를 간략히 할 수 있는 이점을 가진다. 화장품에서의 검출되는 빈도가 높고, 사람과 동물에 영향을 미치는 환경호르몬으로 보고되는 dibutyl phthalate (DBP)와 di (2-ethylhexyl) phthalate (DEHP) 두 종의 프탈레이트를 분석대상으로 선정하였다. 정량시 그 정확도 향상을 위해서 내부표준물질로 두 물질의 중수소치환체인 DBP-$d_4$,와 DEHP-$d_4$를 사용하였다. 시험법의 유효화를 시행한 결과 본 시험법이 ppm 농도의 프탈레이트 정량분석에 적합함을 확인하였으며, 네일락카와 헤어스프레이 제품에 약 $25{\mu}g/g$의 농도로 표준물질을 첨가하여 분석한 회수율은 95 - 106.1 % 범위였고, % 상대표준편차 값은 3.9 % 이하였다.