• Title/Summary/Keyword: contamination process

Search Result 736, Processing Time 0.026 seconds

A study on establishment of bio-hazard analysis and critical control point for pork slaughter house (돼지도축장의 생물학적 위해요소에 대한 중요관리점 설정)

  • 옥천석;정지영;송은아;이성식
    • Korean Journal of Veterinary Service
    • /
    • v.24 no.2
    • /
    • pp.117-126
    • /
    • 2001
  • To ensure the safety of domestic livestock products, the government made it obligatory to enforce the hazard analysis critical control point(HACCP) in all domestic slaughterhouses. Under the HACCP, most of the hazards generated in slaughterhouses are bio-hazards, especially pathogenic bacteria. In order to reduce to the pathogenic bacteria, critical control point (CCP) is established and controled in the process of slaughter. A study was carried out to measure the level of bacterial contamination of swine carcass in 6 slaughterhouses selected. As a result, the aerobic plate counts(cfu/$\textrm{cm}^2$) of all samples was $10^2$-10 in average, except slaughterhouse C. The level of the aerobic plate counts on the surface of lower loin in slaughterhouse C was $10^4$ and it was considered that slaughterhouse C should set the process of manual transport of carcass as the CCP. Escherichia coli level was the highest in middle line cut surface. Especially, E coli level of slaughterhouses C and D were about 6.5- and 3.0-fold higher than that of other 4 slaughterhouses. Thus, it was considered that the slaughterhouses C and D should set the process of the entrails treatment as the CCP. The air contamination was measured at two point in a slaughterhouse. The air contamination level was 4-13 times higher than that of the standard Japanese slaughterhouses.

  • PDF

Signal analysis of surface discharge and electromagnetic wave for insulator by kaolin contamination (카올린으로 오손된 애자의 표면방전 및 방사전자파의 신호 분석)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.7 no.3
    • /
    • pp.113-118
    • /
    • 2004
  • Recently, diagnosis techniques have been investigated to detect a partial discharge associated with a dielectric material defect in a high voltage electrical apparatus. However, the properties of detection technique of PD aren't completely understood because the physical process of PD. Therefore, this paper analyzes the process on Surface Discharge of Polymer Insulator using Wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time frequency domain. As it is important to develop a non-contact method for detecting the Contamination Degree, this research analyzes the electromagnetic waves emitted from PD using Wavelet transform. This result experimentally shows the process of PD as a two-dimensional distribution in the time-frequency domain. The method is shown to be useful for detecting prediction of contamination degree.

  • PDF

Contamination structure and process on SUS 316 under UHV, HV and air (초고진공, 고진공, 대기압에서 SUS 316의 오염 구조와 오염 과정 연구)

  • 서지근;이규장;신용현;홍승수;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.1
    • /
    • pp.1-8
    • /
    • 1997
  • The contamination structure and process on SUS 316 under various exposure conditions were investigated using x-ray photoelectron spectroscopy. The metal-oxide, metal-H-oxides, CO, COH, and $C_xH_y$ are the main components of contaminants on the SUS surface. The compositional profiles of the contaminants are shown to be $C_xH_y$/CO(COH)/metal-oxide on SUS. The contamination proceeds in two steps. The oxidation of the metallic constituents followed by adsorption of hydrocarbons. Under UHV conditions the contamination is mainly due to the oxidation, and, as the exposure time increases, the oxidation continues. In HV or higher pressure, most of the oxides are formed almost immediately after exposure and as the exposure time increases the contamination of hydrocarbons continues to grow. For the SUS sample exposed to atmosphere, the metal oxide is distributed deep inside the surface with an exponentially decreasing concentration, and its thickness is nearly in the order of photoelectron mean free path. It is also seen that the Fe oxide is segregated over Cr oxide in the highly oxidized samples.

  • PDF

UNG-based direct polymerase chain reaction (udPCR) for the detection of porcine circovirus 2 (PCV2) (UNG 기반 direct polymerase chain reaction (udPCR)을 이용한 돼지 써코바이러스 2형 진단법)

  • Kim, Eun-Mi;Park, Choi-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.37 no.4
    • /
    • pp.253-261
    • /
    • 2014
  • Porcine circovirus disease (PCVD) is a major problem of swine industry worldwide, and diagnosis of PCV2, causal agent of PCVD, has been doing in clinical laboratories of pig disease by polymerase chain reaction (PCR) methods. But the PCR analyses have a serious problem of misdiagnosis by contamination of DNA, in particular, from carryover contamination with previously amplified DNA or extracted DNA from field samples. In this study, an uracil DNA glycosylase (UNG)-based direct PCR (udPCR) without DNA extraction process and DNA carryover contamination was developed and evaluated on PCV2 culture and field pig samples. The sensitivity of the udPCR combined with dPCR and uPCR was same or better than that of the commercial PCR (cPCR) kit (Median diagnostics, Korea) on PCV2-positive serum, lymph node and lung samples of the pigs. In addition, the udPCR method confirmed to have a preventing ability of mis-amplification by contamination of pre-amplified PCV2 DNA from previous udPCR. In clinical application, 170 pig samples (86 tissues and 84 serum) were analysed by cPCR kit and resulted in 37% (63/170) of positive reaction, while the udPCR was able to detect the PCV2 DNA in 45.3% (77/170) with higher sensitivity than cPCR. In conclusion, the udPCR developed in the study is a time, labor and cost saving method for the detection of PCV2 and providing a preventing effect for DNA carryover contamination that can occurred in PCR process. Therefore, the udPCR assay could be an useful alternative method for the diagnosis of PCV2 in the swine disease diagnostic laboratories.

Influence of Radioactive Contamination to Agricultural Products Due to Dry and Wet Deposition Processes During a Nuclear Emergency (원자력 사고 중 핵종의 건. 습침적에 따른 농작물 오염 영향)

  • Hwang, Won-Tae;Kim, Eun-Han;Suh, Kyung-Suk;Han, Moon-Hee;Choi, Pong-Ho;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.165-170
    • /
    • 2002
  • Combined with deposition model onto the ground of radionuclides, the influence of radioactive contamination to agricultural products was analyzed due to wet deposition as well as dry deposition from radioactive air concentration during a nuclear emergency. The previous dynamic food chain model, in which initial input parameter is only radionuclide concentrations on the ground, was improved for the evaluating of radioactive contamination to agricultural products from either radionuclide concentrations in air or radionuclide concentrations on the ground. As the results, in case of deposition onto the ground, wet deposition was more dominant process than thy deposition. While the contamination levels of agricultural products were dependent on the a variety of factors such as radionuclides and rainfall rate. It means that the contamination levels of agricultural products are determined from which is more dominant process between deposition on the ground and interception onto agricultural plants.

Effect of Impurities on Stress Induced Void Formation in Al-1% Si Conductors

  • Lee, Seong-Min
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.3
    • /
    • pp.12-17
    • /
    • 2001
  • It is shown in the present study that during the HTS (hot temperature storage) test, the metal contamination by impure elements can be highly susceptible to the void formation, leading to the open failure of the power line in the memory device. Such a functional failure associated with the metal contamination was investigated to be dominant in the early stages of the HTS test while the formation of a stress-driven void is mainly observed in the later stages. In particular, it was found that the void formed in the contaminated metal takes on a slit-like shape which has been known to be characteristic of the stress-related voiding. The impure elements leading to the metal degradation were identified to be carbon and oxygen introduced during the metal sputtering process. The experimental works show that the device reliability was significantly improved by reducing the level of such impure elements within metal. It is shown in the present study that during the HTS (hot temperature storage) test, the metal contamination by impure elements can be highly susceptible to the void formation, leading to the open failure of the power line in the memory device. Such a functional failure associated with the metal contamination was investigated to be dominant in the early stages of the HTS test while the formation of a stress-driven void is mainly observed in the later stages. In particular, it was found that the void formed in the contaminated metal takes on a slit-like shape which has been known to be characteristic of the stress-related voiding. The impure elements leading to the metal degradation were identified to be carbon and oxygen introduced during the metal sputtering process. The experimental works show that the device reliability was significantly improved by reducing the level of such impure elements within metal.

  • PDF

Method to Evaluate Fabric Contamination Due to Fine Dust (섬유소재의 미세먼지 오염도 평가 방법 개발에 관한 연구)

  • Hwang, So-Young;Kwon, Jin-Kyung;Kim, Young-Sil;Choi, Eun-Jin;Kim, Da-Jin;Kim, Min;Yook, Se-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.11
    • /
    • pp.86-91
    • /
    • 2021
  • Recently, functional clothes that can reduce deposition and/or penetration of fine dust have been developed. However, there are no methods to quantitatively evaluate the performance of these clothes. In this study, we developed a method to contaminate a fabric using fine dust and established an approach to quantitatively assess the degree of particle contamination on the fabric surface. Silicate powder was chosen as the particle to simulate fine dust because silicate particles are fluorescent under UV light; therefore, they can be distinguished from any color of non-fluorescent fabric surface. A camera with a high-resolution lens system was used to scan the surface of the contaminated fabric surface, and the degree of particle contamination of the fabric surface was analyzed in terms of the pixels corresponding to the area of the fabric surface contaminated by silicate particles. Finished or unfinished nylon fabrics as well as cotton fabrics were contaminated with silicate particles, and their surfaces were scanned using the established camera. The proposed assessment method was found to be useful for quantitatively comparing the degree of particle contamination of the fabrics.

Combined TPH and BTEX Analytic Method to Identify Domestic Petroleum Products in Contaminated Soil (오염토양 내 석유제품 판별을 위한 TPH 및 BTEX 분석)

  • Lim, Young-Kwan;Na, Yong-Gyu;Kim, Jeong-Min;Kim, Jong-Ryeol;Ha, Jong-Han
    • Tribology and Lubricants
    • /
    • v.33 no.6
    • /
    • pp.263-268
    • /
    • 2017
  • The significance of maintaining the soil environment is gradually increasing owing to soil and underground water contamination by petroleum leak accidents. However, the purification of soil is an expensive and more time-consuming process than the purification of contaminated water and air. Moreover, determining the source and people responsible for soil pollution gets often embroiled in legal conflicts, further delaying the cleanup process of the contaminate site. Generally, TPH (total petroleum hydrocarbon) pattern analysis is used to determine the petroleum species and polluter responsible for soil contamination. However, this process has limited application for petroleum products with a similar TPH pattern. In this study, we analyze the TPH pattern and specific sectional ratio (${\sim}C_{10}$, $C_{10}-C_{12}$, $C_{12}-C_{36}$, and $C_{36}{\sim}$) of various domestic petroleum products to identify the petroleum product responsible for soil contamination. Also, we perform BTEX (benzene, toluene, ethyl benzene, xylene) quantitative analysis and determine B:T:E:X ratio using GC-MS. The results show that gasoline grade 1 and 2 have a similar TPH pattern but different BTEX values and ratios. This means that BTEX analysis can be used as a new method to purify soil pollution. This complementary TPH and BTEX method proposed in this study can be used to identify the petroleum species and polluters present in the contaminated soil.

Regional-Scale Evaluation of Groundwater Susceptibility to Nitrate Contamination Based on Soil Survey Information (토양정보를 이용한 광역 지하수의 질산태 질소 오염 민감도 분포 분석)

  • Han, Gwang-Hyun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.1
    • /
    • pp.37-45
    • /
    • 2009
  • Susceptibility assessment of groundwater contamination is a useful tool for many aspects of regional and local groundwater resources planning and management. It can be used to direct regulatory, monitoring, educational, and policy-making efforts to highly vulnerable areas. In this study, a semi process-based was proposed to evaluate relative susceptibilities to groundwater contamination by nitrate on a regional scale. Numerical simulation based on data from each soil series was done to model water flow within soil profiles that were related to groundwater contamination by nitrate. Relative vulnerability indices for each soil series were produced by manipulation of amount of leaching flux, amount of average water storage in a soil profile, and amount of average water storage change. These indices were designed to convey the trend of leaching flux and to maximize spatial resolution. The resulting vulnerability distribution map was used to locate highly vulnerable sites easily with an appropriate grouping the indices, and was then compared with those from groundwater nitrate concentrations monitored. An excellent agreement was obtained across nitrate concentrations from the highly vulnerable regions and those from the low to stable regions.

An Estimation of Contamination Degree using the Statistical Analysis between Contamination and Climatic Data (오손도와 기상 데이터의 통계적 분석을 이용한 오손도 예측)

  • 심규일;김호수;김주한;박흥석;한상옥
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.73-77
    • /
    • 2004
  • The accumulation of salt contamination could be the source of electrical accident. The degree of contamination on outdoor insulator is represented by ESDD(equivalent salt deposit density). The salt is transported by the wind to the outdoor insulator and cleaned by the rain. So, we can estimate the relation between climatic data and ESDD by using the multiple regression method. The results of pre-study presented the high relation coefficient(0.874). But these results couldn't apply to another period So, this paper improves above problem by mathematical process of climatic data The main method is accumulation of passed climatic data and conversion of the rainfall by the wind. Then, we confirmed the increasement of relation coefficient(0.898).