• Title/Summary/Keyword: contamination materials

Search Result 728, Processing Time 0.027 seconds

Comparison of the Mechanical Properties between Bulk-fill and Conventional Composites (Bulk-fill 복합레진과 전통적 복합레진의 물성비교)

  • Noh, Taehwan;Song, Eunju;Park, Soyoung;Pyo, Aeri;Kwon, Yonghoon;Kim, Jiyeon;Kim, Shin;Jeong, Taesung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.4
    • /
    • pp.365-373
    • /
    • 2016
  • Composites are the most useful restorative material. However, composites have some disadvantages such as polymerization shrinkage, long working time, and susceptibility to water and contamination, which are stood out more especially when treating children. To solve these problems, bulk-fill composites have been developed. The aim of this study is to compare mechanical properties of bulk-fill and conventional composites. Bulk-fill composites (SureFil SDR flow (SDR), Tetric N-Ceram bulk fill (TBF)) and conventional composites (Filtek Z-350 (Z-350), Unifil Flow (UF), Unifil Loflo Plus (UL)) were used. The Vickers hardness tester was used to measure the microhardness of materials, and Fourier transform infrared spectroscopy was used to measure the degree of conversion. Polymerization shrinkage was measured by using a linometer. Flexural and compressive properties were measured by using the universal testing machine. Data were statistically analyzed by ANOVA and Scheffe's post hoc test. The level of significance was set to p < 0.05. Most conventional composites showed higher microhardness than bulk-fill composites. However, bulk-fill composites showed a higher top/bottom microhardness ratio than conventional composites. Bulk-fill composites showed a higher top/bottom degree of conversion ratio than conventional composites. The polymerization shrinkage was highest in UL and lowest in Z-350. The polymerization shrinkage of flowable composites was higher than that of non flowable composites. The compressive properties were highest in Z-350 and lowest in SDR and UL. In terms of flexural properties, Z-350 was the highest. However, none of the bulk-fill composites exhibited mechanical properties as good as those of conventional composites. Nonetheless, the ratio of microhardness and degree of conversion, which are important properties of bulk filling, were higher in bulk-fill composites. Therefore, the bulk-fill composites might be considered suitable restorative materials in pediatric dentistry.

Study on the Intake Pattern of Health Intended Foods Depending on Inclusion of Proclaimed Health Functional Food Materials (건강기능식품에 의해 고시된 원료 포함여부에 따른 건강증진용 식품의 섭취양상 비교)

  • Park, You-Gyoung;Park, Mi-Young;Sung, Mi-Kyung;Kwon, Hoonjeong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.3
    • /
    • pp.374-379
    • /
    • 2005
  • The intake of health foods with physiological effects may cause adverse effects due to their intrinsic compounds, external contamination or consumers' eating patterns. To keep pace with the increasing interest on the safety assurance, Health Functional Food Act has been enacted and standards and specifications for 32 products have been proclaimed by Korea Food and Drug Administration in 2004. To reduce the safety problems related with the intake of non regulated health intended food, we classified the health intended foods materials into two groups, as proclaimed health functional food materials and others, and examined the difference of intake patterns on both categories. Among 16,474 health intended foods responded by 5,175 respondents and their household members, 49.2% were categorized as health functional food materials. The average number of total health intended foods intake and health functional foods intake per person were 3.19 and 1.58 respectively. The proportion of health functional foods in total health intended foods per person was higher in the group with less than 20 years old, therefore this age group needs relatively low concern. On the other hand, 40-59 years old females who have taken the highest number of health food items, 30-59 years old males who had the lowest proportion of health functional foods to total health intended food, and their consumed foods such as medicinal plant and animal protein based restoratives need relatively high concern about intake safety of health foods.

Assessment of Microbiological Quality for Raw Materials and Cooked Foods in Elementary School Food Establishment (초등학교에 공급되는 급식용 식재료 및 조리식품의 미생물학적 품질평가)

  • Shin, Weon-Sun;Hong, Wan-Soo;Lee, Kyung-Eun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.3
    • /
    • pp.379-389
    • /
    • 2008
  • This study was conducted to assess the microbiological quality of raw and cooked foods served in the elementary school food service. Raw and cooked food samples were collected from 11 selected elementary schools in both June to July and September to October of 2005. Petrifilm plates were used to determine (in duplicate) total aerobic colony counts (PAC), Enterobacteriaceae (PE), coliform counts (PCC), and E. coli counts (PEC). Heavy contamination of Enterobacteriaceae (from 0.08 to 7.40 log CFU/g) and total coliform (0.50 to 6.52 log CFU/g) were observed in raw materials and cooked foods. Escherichia coli (E. coli) were detected in the sample of currant tomato (3.70 log CFU/g), sesame leaf (3.59 log CFU/g), dropwort (0.20 log CFU/g), crown daisy (3.15 log CFU/g), parsley (3.00 log CFU/g), peeled green onion (1.74 log CFU/g), frozen pork (0.65 log CFU/g), frozen beef (0.20 or 1.50 log CFU/g), chicken (1.78 log CFU/g), and young radish leaf seasoned with soybean paste (1.24 log CFU/g). Multiplex PCR system was used to determine the food-borne pathogens: Salmonella spp., Bacillus cereus (B. cereus), E. coli O157:H7, Staphylococcus aureus, Listeria monocytogenes (L. monocytogenes), Vibrio parahaemolyticus, Campylobacter jejuni (C. jejuni), Shigella spp., B. cereus was detected in 19 samples of raw materials and 8 samples of cooked foods. With regard to quantitative analysis, B. cereus counts exceeded 5.46, 3.48 and 1.79 log CFU/g in sesame leaf, peeled green onion and seasoned mungbean jelly, respectively. E. coli O157:H7 was detected on 2 samples of frozen beefs, and its biochemical characteristics of one beef sample was confirmed with API 20E kit (93.7%). L. monocytogenes was detected in fried rice paper dumpling, but the presumptive colonies were not detected onto the conventional plate. C. jejuni was detected in peeled & washed onion.

Study on Radioactive Material Management Plan and Environmental Analysis of Water (II) Study of Management System in Water Environment of Japan (물 환경의 방사성 물질 관리 방안과 분석법에 관한 연구 (II) 일본의 물 환경 방사성물질 관리 체계에 대한 고찰)

  • Han, Seong-Gyu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.305-313
    • /
    • 2015
  • After Fukushima Daiichi nuclear disaster in 2011, study and maintenance of monitoring systems have been made at home and abroad. As concerns about radioactive contamination of water have increased in Korea, update of maintenance of managing radioactive materials in water is being made mainly by Ministry of Environment. In this study, we analysed current state of monitoring system modification in Japan, the country directly involved and neighboring country. According to the result, Japan modified the legislations first. Then Ministry of Education, Culture, Sports, Science and Technology (MEXT) provides theoretical background of radiological monitoring. And Ministry of the Environment actually watches state of water pollution in public waters and underground water. Finally related agencies like local government are monitoring current state of radioactive contamination in water environment. By region, local monitoring stations share the investigation of the whole country. Also, additional monitoring is running around nuclear facilities. After Fukushima disaster, monitoring for area near Fukushima is added. Among the reference levels, management target value of drinking water and tap water is 10 Bq/kg, and those of public water and underground water are 1 Bq/L. Measuring intervals varied from every hour to once a year, regularly or irregularly depending on the investigation. The main measuring items are air dose rate, gross ${\alpha}$, gross ${\beta}$, ${\gamma}$ radionuclide, Cs-134, Cs-137, Sr-89, Sr-90, I-131, and so on. In comparison, regulations about general public water in Korea need to be modified, while those about area near nuclear facility and drinking water are organized well. In future, therefore, domestic system would be expected to be modified with making reference to the guidelines like WHO's one. As good case of applying international guideline to domestic environment, Japanese system could be a reference when general standard of radioactivity in public water is made in Korea.

Importance and Performance Analysis of Sanitation Management in Workers at Small and Medium Foodservice Industries Using HACCP Prerequisites (HACCP 선행요건 기준을 활용한 중·소 외식업체 종사자의 위생관리 중요도·수행도 분석)

  • Lee, Hyun-Jun;Hong, Wan-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.10
    • /
    • pp.1497-1507
    • /
    • 2016
  • The purpose of this study was to conduct importance and performance analysis of sanitation management in workers at small and medium foodservice industries using HACCP prerequisites. Questionnaires were distributed to 500 small and medium foodservice industry workers in Seoul Gyeonggi province, and a total of 458 responses were used for analysis. Factors with relatively low comparison degree were as follows. 'Handwashing and clean uniform of employee in the workplace', 'regular checking and managing of trapped vermin and rodents', 'checking stocked raw materials', 'recording and filing the results of improved food safety factors', and 'regular cleaning and sterilizing of monitoring tools' factors must be improved along with their performance levels through sanitation education. According to the IPA results, among the 15 HACCP prerequisite factors with high importance but low performance were '2. Regular checking and managing of trapped vermin and rodents', '4. Handwashing and clean uniform of employee in the workplace', '14. Preventing food cross-contamination'. Furthermore, the small and medium foodservice industry IPA with high importance but low performance were 'Regular checking and managing of trapped vermin and rodents', 'Handwashing and clean uniform of employee in the workplace', and 'Preventing food cross-contamination' for the small foodservice industry, along with 'Vermin and rodents control' and 'Recording and filing the results of improved food safety factors' for the medium foodservice industry. Thus, there is a need for reinforced hygiene education through case studies on actual food service establishments to fulfill sanitation guidelines and set amended guides for much-needed items for small and mid-sized food service.

Quantitative Evaluation of Foodborne Pathogenic Bacteria in Commercial Sangshik (시판 생식에서 식중독균의 정량적 평가)

  • Kwak Hyo-Sun;Whang In-Kyun;Park Jong-Seok;Kim Mi-Gyeung;Lee Kyun-Young;Gho Young-Ho;Bae Yoon-Young;Moon Sung-Yang;Byun Ju-Sun;Kwon Ki-Sung;Woo Gun-Jo
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.1
    • /
    • pp.41-46
    • /
    • 2006
  • This study was carried out to survey the prevalence of foodborne pathogens in Sangshik products and their raw materials far the purpose of ensuring safety of those products in market, and establishing microbial regulatory standard. From 2002 to 2004, a total of 191 Sangshik products were purchased from market or mail-order sales, and major foodborne pathogens; E. coli, Salmonella, Staphylococcus aureus, Bacillus cereus, Clostridium perfringens, Listeria monocytogenes, Campylobacter jejuni, Yersinia enterocolitica, E. coli O157:H7, Vibrio parahaemolyticus were tested. B. cereus, C. perfringens and E. coli were detected from 29 samples (15.2%), 21 samples (11.0%) and 1 sample (0.5%), respectively. But other tested bacteria were not detected. For the identification of contamination source, 53 Sangshik ingredients were collected from 9 different manufacture factories. The results were similar with the Sangshik products. Aerobic plate counts were ranging from $1.0X10^3cfu/g\;to\;1.5X10^8cfu/g$. B. cereus was detected from 13 samples (24.5%), and counted as less than 100 cfu/g. C. perfringens were detected from 2 samples (3.8%), and counted as less than 100 cfu/g. Other foodborne pathogens were not detected except for B. cereus and C. perfringens. From the results, it was revealed that potential of microbial hazard by Sangshik was relatively low. However, it would be suggested that hygienic management and controling be needed for the prevention of growing contaminated pathogens and cross contamination during process and sale due to improper storage and management.

Evaluation of Reliability about Short TAT (Turn-Around Time) of Domestic Automation Equipment (Gamma Pro) (국산 자동화 장비(Gamma Pro)의 결과보고시간 단축에 대한 유용성 평가)

  • Oh, Yun-Jeong;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.197-202
    • /
    • 2010
  • Purpose: Recently, many hospitals have been tried to increase the satisfaction of the outpatients through blood-gathering, exam, result notice and process in a day. Each laboratory has been used the automatic equipment for the rapid requests of the result notice and the increase of the reliability and efficiency. Current automatic equipments that have been limited short TAT(Turn-Around Time)because of the restricted batch lists and 1 tip-5 detectors. The Gamma Pro which is made in Korea to improve the shortcomings of existing automation equipment, complemented with capacity to perform a wide range of domestic automation equipment. In this study, we evaluated the usefulness and reliability of short TAT by comparing Gamma Pro with current automatic equipment. Materials and Methods: We studied the correlation between Gamma Pro and RIA-mat 280 using the respective 100 specimens of low or high density to the patients who were requested the thyroid hormone test (Total T3, TSH and Free T4) in Samsung Medical Center Sep. 2009. To evaluate the split-level Gamma Pro, First, we measured accuracy and carry over on the tips. Second, the condition of optimal incubation was measured by the RPM (Revolution Per Minute) and revolution axis diameter on the incubator. For the analysis for the speed of the specimen-processing, TAT was investigated with the results in a certain time. Result: The correlation coefficients (R2) between the Gamma Pro and RIA-mat 280 showed a good correlation as T3 (0.98), TSH (0.99), FT4 (0.92). The coefficient of variation (C.V) and accuracy was 0.38 % and 98.3 % at tip 1 and 0.39 % and 98.6 % at tip 2. Carry over showed 0.80 % and 1.04% at tip 1 and tip 2, respectively. These results indicate that tips had no effect on carry over contamination. At the incubator condition, we found that the optimal condition was 1.0mm of diameter at 600RPM in 1.0mm and 1.5mm of at 500RPM or 1.0mm and 1.5 mm of diameter at 600 RPM. the Gamma Pro showed that the number of exam times were increased as maximum 20 times/day comparing to 6 times/day by current automatic equipment. These results also led to the short TAT from 4.20 hour to 2.19 hours in whole processing. Conclusion: The correlation of between the Gamma Pro and RIA-mat 280 was good and has not carry over contamination in tips. The domestic automation equipment (Gamma Pro) decreases the TAT in whole test comparing to RIA-280. These results demonstrate that Gamma Pro has a good efficiency, reliability and practical usefulness, which may contribute to the excellent skill to process the large scale specimens.

  • PDF

Health Assessment for Glass Fibre Landfill at Gozan-dong, Inchon (인천시 고잔동에서 제기된 유리섬유에 의한 건강피해 역학 조사)

  • Cho, Soo-Hun;Ju, Yeong-Su;Kim, Kyung-Ryul;Lee, Kang-Kun;Hong, Kug-Sun;Eun, Hee-Chul;Song, Dong-Bin;Hong, Jae-Woong;Kwon, Ho-Jang;Ha, Mi-Na;Han, Sang-Hwan;Seong, Joo-Heon;Kang, Jong-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.1 s.56
    • /
    • pp.77-101
    • /
    • 1997
  • In September 1994, residents of Gozan-dong, Incheon City, made a petition to the government about their health problems which might be caused by previous glass fibre landfill nearby 'H' company. In february 1995, at regular academic meeting of occupational and environmental medicine, a research team of 'D' University presented that they had found glass fibres in groundwater of the area through their survey. They were suspicious of probable association between ingestion of groundwater contaminated with glass fibres and skin tumors among residents. A joint research team was formed and carried out the survey of environment concerning groundwater and its glass fibre existence, and health assessment of residents in the area and industrial workers of 'H' company during May to November, 1995. Analysis of groundwater flow system indicates that the flow lines from the glass fibre landfill pass through or terminate at the 6 houses around the landfill. This means that the groundwater of the 6 houses around the glass fibre landfill could be affected by some possible contaminants from the landfill, but the groundwater quality of the other houses was irrelevant to the landfill. The qualitative and qualitative analyses for glass fibres in 54 groundwater samples including those from the nearby 6 houses, were carried out using SEM equipped with EDS, resulting in no evidence for the presence of glass fibres in the waters. Major precipitates, formed in waters while boiling, were identified as calcium carbonates, in particulary, aragonites in needle form. The results of health assessments of 889 residents in Gozan-dong, participated in this study, showed statistically significant differences in past medical histories of skin tumor and respiratory disease between the exposed group (31 persons who inhabited in 6 houses around the landfill) and the control group, but no significant differences in past medical histories of other diseases, such as cancer mortality, current gastroscopic findings, current skin diseases and respiratory diseases, etc. Also, we could not prove any glass fibres in excised specimens of 9 skin tumors in both groups and there were no health problems possibly associated with glass fibres in employees of the 'H' company. After all, we could not authenticate the association, raised by prior investigators, between groundwater streams, assumedly contaminated with glass fibres or not, and specific disease morbidities or common disease/symptom prevalences. That is, we could not find any glass fibres in groundwater as the only exposure factor of this study hypothesis, and there were not enough certain evidences such as increasing disease prevalences, for examples, skin, respiratory and gastrointestinal diseases etc, possibly related to glass fibre exposure, in exposed group. As a matter of course, the conditions for confirming causal association, for example, strength of the association, consistency of the association, specificity of the association, temporality of the association and dose-response relationship etc, have not been satisfied. In conclusion, we were not able to certify the hypothesis that contamination of groundwater with glass fibres might cause any hazardous health effects in residents who used it for drinking.

  • PDF

The Effect of Contamination of Ion Source on Ionic Current of Quadrupole Mass Spectrometer (사중극 질량 분석기의 이온소스 오염이 이온전류에 미치는 영향)

  • Lee, K.C.;Park, C.J.;Kim, J.T.;Oh, E.S.;Hong, K.S.;Hong, S.S.;Lim, I.T.;Yun, J.Y.;Kang, S.W.;Shin, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.197-202
    • /
    • 2009
  • The long term stability of ion current of QMS has been one of key parameters for monitoring gas process in vacuum. The time dependence of ionic current was monitored while the pressure of nitrogen gas was kept at a fixed pressure by introducing the gas into vacuum chamber. The chamber was evacuated to ${\sim}3{\times}10^{-9}\;Torr$ to reduce background signals before the measurement. Two ion sources were tested; one had brownish or black color due to gas contamination and the other one was new, i.e. cleaner. At a nitrogen pressure of $1{\times}10^{-5}\;Torr$, the ionic currents measured by the contaminated ion source decreased faster with time. The decrease rate was respectively ${\sim}46%$ for cleaner one and ${\sim}84%$ for contaminated one after ${\sim}5.5%$ hours. In order to test the effect of filament material on the ion current decrease, we fabricated a tungsten(W) filament which consisted of two parts; one half was made of W and the other was coated with yttria. The similar decrease of ionic currents were shown for the two types of filaments, indicating that slight change of temperature of filament due to material difference i.e. baking effect could not improve the origin of ionic current decrease. Overall the decreasing rate of ionic current is more closely associated with contaminated ion source of QMS rather than its filament materials.

Consideration about Ozone Generation in the Treatment Room While Treating a Patient (방사선 치료 시 치료실 내에서 발생하는 오존에 관한 고찰)

  • Kwak, Yong-Kuk;Yoon, Il-Kyu;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.75-82
    • /
    • 2009
  • Purpose: Measure the ozone level in the treatment room while treating a patient so want to know the degree of contamination caused by ozone occurrence. Materials and Methods: Use the linear accelerator (Clinac 21EX, Varian, USA) with the ozone meter (series-200, aeroQual, New Zealand) and water phantom (Wellhofer, IBA, Germany) is irradiated the radiation so that measured the ozone generation level according to MU, dose-rate, SSD, field size, energy, delay time and put the ozone meter in the treatment room actually while treating a patient so measured the daily ozone level variation. Results: While irradiating the radiation, degree of ozone contamination wasn't affected by the energy but mostly in case of electron beam, ozone level was higher than photon beam. The higher dose-rate (0.016~0.025 ppm/hr), the farther SSD (0.018~0.030 ppm/hr), the wider field sizes (0.016~0.025 ppm/hr), the more MU (0.018~0.046 ppm/hr), it occurred high ozone level. Ozone decrement according to delay time changed the background level (0.016 ppm/hr) after elapsed time of 10 minutes from irradiating radiation. And daily ozone occurrence level in the treatment room was below ozone standard level 0.1 ppm/hr (average:0.06 ppm/8 hr) but it could confirm that ozone generation level was included the level (max:0.038 ppm/hr) above 0.02 ppm/hr which patient could perceive. Conclusion: Through ozone level according to variation of certain conditions, actually in the treatment room ozone generation level didn't damaged to patients or workers. Commonly peoples think that ozone was harmful gas but it thought that small amount of ozone generation level while treating a patient was beneficial in the treatment room through air purge action of pathogenic germ or virus sterilization.

  • PDF