• Title/Summary/Keyword: contamination materials

Search Result 725, Processing Time 0.025 seconds

Recommendable Methods for Effective Improvement of Management System on Organic Materials based on the Analysis of Unintentional Contamination Investigation and Recognition Survey collected from Organic Farmer and so on (유기농업자재중 비의도적 오염원 조사분석 및 친환경농업인 등 인식조사에 근거한 유기농업자재 관리제도의 효율적 개선방안)

  • Ahn, In;Lee, In-Ae;Sim, Mi-Jin
    • Korean Journal of Organic Agriculture
    • /
    • v.23 no.4
    • /
    • pp.659-682
    • /
    • 2015
  • This study was conducted to suggest ideal management system for organic materials. As the performing method of the study, surveyed results on understanding of related persons (organic farmer 846, organic materials manufacture 70 and Organic materials Auditors 7) with eco-friendly farming were used. And the opinion on unintentional pollution source contained in organic materials was surveyed additionally. The issues pointed out by organic farmers on product of organic materials were high price (60% to total), poor efficacy (16%), disorder on distribution system (13%) and containing chemicals as a pesticide (10%). And notification system for organic materials was accepted in general (positive and so so 76%) while most interviewees preferred (89%) unification of certification system dominantly. As unintentional contamination source, pollution on imported row material was indicated as major reason, and other causes were confirmed as insertion during manufacturing process, agricultural by-products using as product additive et al. Based on these surveyed results, authors suggest bellows as considerable methods for effective improvement of management system on organic material. First, establish new integrated certification system which contains standard of quality certification and notification system on organic material. Second, for evaluation of efficacy, apply relative evaluation system of significance such as Duncan's multiple test instead of existing absolute evaluation system. Third, constitute and operate selection of standard comparison subcommittee in organic Agro-materials committee in RDA.

Evaluation of the effect of blood contamination on the compressive strength of MTA modified with hydration accelerators

  • Oloomi, Kaveh;Saberi, Eshaghali;Mokhtari, Hadi;Mokhtari Zonouzi, Hamid Reza;Nosrat, Ali;Nekoofar, Mohammad Hossein;Dummer, Paul Michael Howell
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.3
    • /
    • pp.128-133
    • /
    • 2013
  • Objectives: This study was performed to evaluate the effect of blood contamination on the compressive strength (CS) of Root MTA (RMTA) modified with Calcium chloride ($CaCl_2$) and Disodium hydrogen phosphate ($Na_2HPO_4$) as setting accelerators over time. Materials and Methods: A total of 110 cylindrical specimens of RMTA were divided into 6 experimental groups as follows: Group1, RMTA; Group 2, RMTA modified with $CaCl_2$ (RMTA-C); Group 3, RMTA modified with $Na_2HPO_4$ (RMTA-N); Group 4, RMTA contaminated with blood; Group 5, RMTA-C contaminated with blood; Group 6, RMTA-N contaminated with blood. The CS of specimens in all groups was evaluated after 3 hr, 24 hr, and 1 wk. In the modified groups (groups 2, 3, 5, and 6) the CS of five specimens per group was also evaluated after 1 hr. Results: Blood contamination significantly reduced the CS of all materials at all time intervals (p < 0.05). After 3 hr, the CS of specimens in the RMTA groups (with and without blood contamination) was significantly lower than those in the RMTA-C and RMTA-N groups (p < 0.05). The CS values were not significantly different at the other time intervals. In all groups, the CS of specimens significantly increased over time (p < 0.05). Conclusions: Blood contamination decreased the CS of both original and accelerated RMTA.

Heavy Metal Contamination and Process for Its Removal in the Vicinity of the Dalsung Cu-W Mine (달성광산(達成鑛山) 주변지역(周邊地域)에서의 중금속오염(重金屬汚染)과 이의 제거방안(除去方案))

  • Kim, Kyoung-Woong;Hong, Young-Kook;Kim, Taik-Nam
    • Economic and Environmental Geology
    • /
    • v.29 no.1
    • /
    • pp.57-63
    • /
    • 1996
  • The Dalsung copper-tungsten mine in the Taegu area, Korea was closed in 1975 and may be the sources of the heavy metal contamination in the tributary system and soil-plant system due to the mine drainage derived from the mine wastes and tailings. To examine the degree and extent of heavy metal contamination in the vicinity of Dalsung mine area, stream water and soil samples were taken and analyzed for heavy metals by ICP-AES and AAS. Highly contaminated soils are found near the Lower Tunnel No.0 ranging up to $1760{\mu}g/g$ As, $2060{\mu}g/g$ Cu, $1120{\mu}g/g$ Pb and 346 ${\mu}g/g$ Zn. From the results of the sequential extraction methods for the metal speciation, the heavy metals in soils may be derived from soil parent materials and acid mine drainage. With the processes for the heavy metal removal, most of the heavy metal ions in the acid mine drainage are removed by being exchanged with Ca ions held by the bentonite, hydroxyapatite and calcium hydoxide.

  • PDF

Properties of Surface Electrical Conduction in Materials for Outdoor Insulator (옥외 애자용 재료의 표면 전기전도특성)

  • 박영국;강성화;정수현;이운석;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.207-210
    • /
    • 1998
  • Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition. The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

Effect of Cleaning Pad on Particle Contamination in Removable Media Disk Drive (이동식 디스크 드라이브의 입자 오염에 대한 클리닝 패드의 효과)

  • 유신성;이정규;김대은
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.4
    • /
    • pp.183-188
    • /
    • 2003
  • Particulate contamination is known to be a significant cause of failures of removable storage media. In this work, the effect of particles on the surface damage of removable hard disk media was investigated. The particles of different materials and size were introduced to the Head Disk Interface (HDI) using a particle injection system. It was round that the particles of particulate size and property serious damaged the media. This study showed that cleaning pad is effective for reducing particle contamination, except fer the particles of specific size and property. As a means to remove the particles of specific sire. the concept of using a stepped taper at the leading edge of the slider is proposed.

A study on the decrease of particle contamination in removable media disk drive (이동식 디스크 드라이브의 입자 오염 저감 방안)

  • 유신성;이정규;김대은
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.946-949
    • /
    • 2002
  • Particulate contamination is known to be a significant cause of failures of removable storage media. In this work, The effect of particles on the surface damage of removable hard disk media was investigated. The particles of different materials and size were introduced to the head-disk interface using a particle injection system. It was found that the particles of particulate size and property serious damaged the media. This study showed that cleaning pad is effective for reducing particle contamination, except for the particles of specific size and property. As a means to removed the particles of specific size, the concept of using a stepped taper at the leading edge of the slider is proposed.

  • PDF

Investigation to Radioactive Contamination of Pool Water in IMEF (조사재시험시설 풀물의 방사성오염에 대한 고찰)

  • 송웅섭;이종헌;이홍기;홍권표
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.162-167
    • /
    • 2003
  • The pool $(3m{\times}6m{\times}10m)$ in Irradiated Materials Examination Facility is usually used for the purpose of taking the specimen out of cask loaded into the pool, and carrying in/out the specimen to/from the hot cell. Always, it must be cared for the water into the pool to be fine condition because all operation are worked with the naked eye during taking an irradiated materials out of the cask and plunging them in the bucket-elevator. In the aspects of the radioactive contamination control, remained substances in the water must be controlled so that the amount of substances are to be lower than the standard amount prescribed by RCA Korea Activity in a part of radioactive contamination control. This paper describes a behavior of the quality of water and the radioactive contamination of pool water for working of pool water purging system and contamination diffusion distribution bahavior of each specimens carried in/out.

  • PDF

Effect of Impurities on Stress Induced Void Formation in Al-1% Si Conductors

  • Lee, Seong-Min
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.3
    • /
    • pp.12-17
    • /
    • 2001
  • It is shown in the present study that during the HTS (hot temperature storage) test, the metal contamination by impure elements can be highly susceptible to the void formation, leading to the open failure of the power line in the memory device. Such a functional failure associated with the metal contamination was investigated to be dominant in the early stages of the HTS test while the formation of a stress-driven void is mainly observed in the later stages. In particular, it was found that the void formed in the contaminated metal takes on a slit-like shape which has been known to be characteristic of the stress-related voiding. The impure elements leading to the metal degradation were identified to be carbon and oxygen introduced during the metal sputtering process. The experimental works show that the device reliability was significantly improved by reducing the level of such impure elements within metal. It is shown in the present study that during the HTS (hot temperature storage) test, the metal contamination by impure elements can be highly susceptible to the void formation, leading to the open failure of the power line in the memory device. Such a functional failure associated with the metal contamination was investigated to be dominant in the early stages of the HTS test while the formation of a stress-driven void is mainly observed in the later stages. In particular, it was found that the void formed in the contaminated metal takes on a slit-like shape which has been known to be characteristic of the stress-related voiding. The impure elements leading to the metal degradation were identified to be carbon and oxygen introduced during the metal sputtering process. The experimental works show that the device reliability was significantly improved by reducing the level of such impure elements within metal.

  • PDF

EFFECT OF SALIVARY CONTAMINATION OF TEETH ON MICROTENSILE BOND STRENGTH OF VAR10US DENTIN BONDING SYSTEMS. (타액에 의한 오염이 상아질 접착제의 미세전단결합강도에 미치는 영향)

  • Choi, Kyoung-Kyu;Ryu, Gil-Joo
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.3
    • /
    • pp.203-208
    • /
    • 2003
  • The purpose of this study was to evaluate the effect of salivary contamination of teeth on bonding efficacy of self-priming and self-etching DBSs. The materials used were Single Bond(SB, self-priming system, 3M), Unifil Bond(UB, self-etching system, GC), and Scotchbond Multi-Purpose Plus(SM, 3M) as control. Forty five human molars randomly allocated to three groups as dentin bonding systems tested and embedded in epoxy resin. Then the specimens were wet-ground to expose flat buccal enamel surface or flat occlusal dentin surface and cut bucco-lingually to form two halves with slow speed diamond saw. One of them was used under non-contamination, other under contamination with saliva. The bonding procedure was according to the manufacturer's directions and resin composite(Z-100, 3M Dental Products, St. Paul, MN) was built-up on the bonded surface 5mm high. The specimens were ground carefully at the enamel-composite interface with fine finishing round diamond bur to create an hour-glass shape yielding bonded surface areas of $1.5{\pm}0.1\textrm{mm}^2$. The specimens were bonded to the modified microtensile testing apparatus with cyanoacrylate, attached to the universal testing machine and stressed in tension at a CHS of 1mm/min. The tensile force at failure was recorded and converted to a tensile stress(MPa). Mean values and standard deviations of the bond strength are listed in table. One-way ANOVA was used to determine significant difference at the 95% level. The bond strength of SBMP and SB were not affected by salivary contamination, but that of UB was significantly affected by salivary contamination. These results indicate that DBSs with total etch technique seems less likely affected by salivary contamination in bonding procedure.

Characterization of Surface Damage and Contamination of Si Using Cylindrial Magnetron Reactive Ion Etching

  • Young, Yeom-Geun
    • Korean Journal of Materials Research
    • /
    • v.3 no.5
    • /
    • pp.482-496
    • /
    • 1993
  • Radiation damage and contamination of silicons etched in the $CF_4+H_2$ and $CHF_3$ magnetron discharges have been characterized using Schottky diode characteristics, TEM, AES, and SIMS as a function of applied magnetic field strength. It turned out that, as the magnetic field strength increased, the radiation damage measured by cross sectional TEM and by leakage current of Schottky diodes decreased colse to that of wet dtched samples especially for $CF_4$ plasma etched samples, For $CF_4+H_2$and $CHF_3$ etched samples, hydrogen from the plasmas introduced extended defects to the silicon and this caused increased leakage current to the samples etched at low magnetic field strength conditions by hydrogen passivation. The thickness of polymer with the increasing magnetic field strength and showed the minimum polymer residue thickness near the 100Gauss where the silicon etch rate was maximum. Also, other contaminants such as target material were found to be minimum on the etched silicon surface near the highest etch rate condition.

  • PDF