• Title/Summary/Keyword: contaminants

Search Result 1,740, Processing Time 0.036 seconds

Effect of Dissolved and Colloidal Contaminants of Newsprint Machine White Water on Water Surface Tension and Paper Physical Properties

  • Consultant, Seika-Tay
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 1999.11b
    • /
    • pp.61-69
    • /
    • 1999
  • Contaminants such as fatty acids, triglycerides, resin acids and foam collected from a high yield sulfite weak liquor storage tank lowered the water surface tension and reduced inter-fibre bonding but also tended to benefit sheet opacity. Some common wet end additives such as defoamers and dispersants gave similar results. Lignosulfonate and naphthalene sulfonate showed little if any negative effect on both surface tension and sheet strength properties. Among the natural wood extractives. fatty acids were identified to be most detrimental followed by triglycerides and then resin acids. In order to alleviate the detrimental impact of these contaminants, membrane separation, air floatation and ozone treatment were carried out on paper machine white water samples. The effect of these treatments on removal of fatty and resin acids was quantified by a GC-Mass analysis. Reverse osmosis with a 1000 molecular weight cut off membrane failed to totally reject fatty and resin acids, but markedly reduced losses of sheet properties due to contaminants. Ozone treatment resulted in a significant increase of the surface tension and air floatation was considered to be a practical and useful method for removing fatty and resin acids from the machine white water.

A Study on Indoor Air Pollutants Reduction Effect by Plants per Season (식물에 의한 계절별 실내공기오염물질 저감효과에 관한 연구)

  • Song, Jeong Eun;Kim, Yong Shik;Sohn, Jang Yeul
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.25-30
    • /
    • 2008
  • This study aims at examining the reduction of indoor air contaminants by plants placed in an indoor space. The effect of reducing the concentration of air contaminants by three species of plants was studied in a full-scale mock-up model. Field measurements were performed using Aglaonema brevispathum, Pachira aquatica and Ficus benjamiana which were verified as air-purifying plants by NASA. Their positions and amount were controlled. Two conditions for the amount of plants(10%, 5%) and positions(sun-shine, scatter) were used in two separate rooms whose dimensions are identical. The concentration of Volatile Organic Compounds(VOCs) was monitored three hours after the plants were placed and three days after the plants were placed. The variations of concentration of Benzene, Toluene, Etylbenzene, Xylene, Stylene and Formaldehyde, which are all known as the major elements of Volatile Organic Compounds were monitored. The more plants were used, the more a reduction of indoor air contaminants occurred. The effect of reducing the concentration of air contaminants increased when the amount of plants increased.

The Study on the experimental of a development of the filtering system for particle/gas phase contaminants (입자/가스상 오염물질 필터링 장치 개발에 관한 실험적 연구)

  • Kim, Tae-Hyung;Nam, Seung-Baeg;Ha, Jong-Pil;Moon, In-Ho;Cho, In-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.387-392
    • /
    • 2007
  • In this study performance evaluation of filtering system were made on the clean air supply system to show it's ability to eliminate the air contaminants. The evaluation was conducted inside the 3,200CMH scale wind tunnel and under the same environment that is effected by yellow dust and similar particle and gas phase contaminants in semi-conductor and FPDs industries. (1) The result of experimental for particle contaminants, the particle removing efficiency was 40% on condition that the air velocity is 2.5m/s, L/G ratio : 0.05, electrified voltage : (+)5.8kV with electric charger and (-)3.5kV with eliminator. (2) The gas phase removing efficiency for $NH_3$ : 80%, $SO_X$ : 70% and $NO_X$ : 40% on condition that the air velocity is 2.5m/s, L/G ratio : 0.05.

  • PDF

Mechanism of TCE Removal with Foundry Sands and Design of Permeable ]Reactive Barriers (주물사의 TCE 제거 메커니즘과 반응벽체에의 적용가능성)

  • ;Benson, Craig H
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.5
    • /
    • pp.143-157
    • /
    • 2002
  • Batch and column tests were conducted with common groundwater contaminants (i.e., trichloroethylene) to determine transport parameters and reactivity of the foundry sands. The reactivities of foundry sands for common groundwater contaminants are comparable to or slightly higher than those for Peerless iron a common medium used in permeable reactive barriers. In addition, the TOC and clay in foundry sands can significantly retard the movement of target contaminants, which may result in lower effluent concentrations of contaminants due to biodegradation. In general, permeable reactive barriers with the thickness of 1m can be constructed with many foundry sands to treat typical groundwater comtaminants provided the zero-valent iron content in the foundry sand is higher than 1%.

Properties of Electrostatic Electrification Degradation due to Contaminant Difference of Silicone Rubbers (오손액 변화에 따른 실리콘 고무의 정전기 대전열화 특성)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.9
    • /
    • pp.587-592
    • /
    • 2015
  • In this study, the electrification voltage of electrostatics for silicone rubber sample($4cm{\times}4cm{\times}0.103cm$) following immersion with contaminants of 2 ml, 5 ml, 10 ml for six hours has been measured in through the applied voltage of 10 kV DC at temperature of $80^{\circ}C{\sim}110^{\circ}C$, humidity of 50%~90%. The results of this study are as follows. In case the contaminants is constant, it found that the electrification voltage of electrostatic decreased with increasing temperature and humidity to $35^{\circ}C$, 90%. In case of 2 ml of contaminants concentration, it found that the electrification voltage of electrostatic decreased with increasing temperature and humidity to $35^{\circ}C$, 50%. In case of the sample at temperature of $15^{\circ}C$ and humidity of 50%, it found that the electrification voltage of electrostatic decreased with increasing contaminants to 10 ml.

Treatability Evaluation of N-Hexadecane and 1-Methylnaphthalene during Fenton Reaction

  • Chae, Myung-Soo;Woo, Sung-Geun;Yang, Jae-Kyu;Bae, Sei-Dal;Choi, Sang-Il
    • Environmental Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.217-225
    • /
    • 2012
  • In this study, the treatability of two target contaminants during the Fenton reaction, n-hexadecane and 1-methylnaphthalene, was evaluated as a function of the amounts of $FeCl_2$ and $H_2O_2$ injected into open and closed reaction systems. In the Fenton reaction of n-hexadecane and 1-methylnaphthalene, the mass recovery of the target contaminants was above 95% in the closed system. However, when the Fenton reaction was performed with high amounts of $H_2O_2$ and $FeCl_2$ injected in the open system, a reduction of approximately 40% of the initial mass of 1-methylnaphthalene was observed. This trend may be explained by the unique physical properties of 1-methylnaphthalene, which has higher volatility than n-hexadecane. Further, this trend was well correlated with the rise in high temperature at the initial reaction stage. Considering the mass recovery of the two target contaminants, the reaction temperature, and the residual concentration of $H_2O_2$ at different amounts of $FeCl_2$ and $H_2O_2$ injected, it can be suggested that the Fenton reaction should be performed with controlled conditions that can provide a suitable reaction environment between oxidant and contaminants.

A Study on the Characteristics of Fenton Oxidation of Bisphenol A and Nitrobenzene (비스페놀A와 니트로벤젠의 펜톤 산화분해 특성)

  • Bae, Su-Jin;Kwon, Hee-won;Kim, Ji-young;Hwang, In-Seong;Kim, Young-Hun
    • Journal of Environmental Science International
    • /
    • v.30 no.12
    • /
    • pp.1005-1014
    • /
    • 2021
  • Organic contaminants can be released into water environments due to chemical accidents and exist as dissolved and non-aqueous phase liquids (NAPL). Fenton oxidation was tested for bisphenol A and nitrobenzene as model organic contaminants in dissolved and NAPL states. Fenton oxidation was successfully applied for both of the dissolved and NAPL states of the two pollutants and the results indicated that a quick treatment was needed to reduce the risk from a chemical accidents instead of carrying out oxidation after the contaminants dissolve in water. A set of Fenton reactions were tested under seawater conditions because chemical accidents often occurs in the ocean. Chloride ions act as radical scavengers and inhibit Fenton oxidation. The reaction rate is inversely proportional to salt contents and the reduced reaction rate can be compensated by increasing the quantity of the oxidizing agents. The current study showes that Fenton oxidation could be applied as a quick treatments for organic contaminant in dissolved and NAPL state organic contaminants released as a result of leaks or chemical accidents.

Design of Integrated Reduction Platform for Food Contaminants Derived from the Environment through Interagency Collaboration in Korea (환경유래 식품오염물질의 범부처 통합 저감화 플랫폼 설계)

  • Ko, Ahra;Heo, Ji-Young;Kang, Young-Woon;Kang, Kil Jin;Chung, Myung-Sub;Lee, Hunjoo
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.4
    • /
    • pp.307-313
    • /
    • 2017
  • Objectives: Chemicals derived from various environment media contaminates food across the food supply chain. In Korea, levels of contaminants in food have been sporadically measured by monitoring programs of different government agencies. There is difficulty with data compilation and integrated analysis across media. Therefore, the aim of this study was to propose an overall integrated database and analytical platform design for the 'ECO-FOOD NET (Environmental COntaminant reduction platform for FOOD through an interagency collaboration NETwork)', a tool to support the reduction of environmental contaminants in food. Methods: We developed a new data structure and standardized protocols for the compilation of integrated data. In addition, we conducted subject-oriented logical and physical relational database modeling and created the architecture design of the platform. Results: We established a standardized code system related to exposure media and route, analysis method and food matrix. In addition, we designed the seven software modules of 'About the System', 'Introduction to Interagency Work', 'Media-Chemicals Profiles', 'Method Bank', 'Monitoring Data Base', 'Integrated Media Analysis', and 'Risk-Benefit Analysis'. Conclusions: This study will contribute to decision-making as a tool for executing risk management, such as sustainable reduction policies of contaminants in food.

Investigations of bacterial contamination level and prevalence of major viral disease for fresh-extended porcine semen (인공수정용 돼지 액상정액 세균오염도 조사 및 정액유래 주요 바이러스성 질병 감염률 조사)

  • Son, Byeong-Guk;Park, Ho-Jung;Kim, Eun-Gyeong;Lee, Jong-Min;Hwang, Bo-Won;Heo, Jung-Ho
    • Korean Journal of Veterinary Service
    • /
    • v.33 no.4
    • /
    • pp.319-326
    • /
    • 2010
  • Bacteroiospermia is a frequently finding in fresh raw and extended porcine semen and can results in detrimental effects on semen quality and longevity. This study aims to evaluate the type of bacterial contaminants in raw and extended porcine semen and the reducing effect of antibiotic test. To investigate bacterial contaminants, out of 387 sample (raw semen 201, extended semen 186) were collected from 6 artifical insemination centers in Gyeongsangnam-do, were inoculated onto blood agar and MacKonkey agar, respectively. Bacterial colonies were selected after culturing for 48 hours, at $37^{\circ}C$, followed by Gram staining, KOH test, oxidase test, catalase test and eventually identified using VITEK System. Total 15 genus and 24 species of bacteria were isolated from these semen samlpes. In raw semen, the most prevalent contaminants were Pseudomonas aeruginosa, Escherichia coli, Proteus mirabilis, Staphylococcus auricularis, Delftia acidovorans, Acinetobacter lowffii, S. aureus and others. And in extended porcine semen, A. lowffii, S. aureus, S. auricularis and other bacteria were identified. Most of them was G(-), which is nonpathogenic bacteria. It seems that bacterial contaminants in fresh raw and extended porcine semen originated from multiple sources at the farms/stud, and were from animal origin and non-animal origins. Whereas, the 7 virus which is known to be detected in porcine semen in 75 cases was not detected. This results showed that removal of bacterial contamination in raw and extended porcine semen is essential and farms were kept for biosecurity and individual hygienes.

Development of the Two-Zone Model to Estimate the Air Quality in Indoor Environments (실내 공기질 평가를 위한 2구획 모델의 개발)

  • 조석호;양성환;이봉헌;정성욱;이병호
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.745-751
    • /
    • 1998
  • The well-mixed room model has been traditionally used to predict the concentrations of contaminants in indoor environments. However, this is inappropriate because the flow fields in many indoor environments distribute contaminants non-uniformly, due to imperfect air mixing. Thus, some means used to describe an imperfectly mixed room are needed. The simplest model that accounts for imperfect air mixing is a two-zone model. Therefore, this study on development of computer program far the two-zone model is carried out to propose techniques of estimating the concentration of contaminants in the room. To do this, an important consideration is to divide a room into two-zone, i.e. the lower and upper zone assuming that the air and contaminants are well mixed within each zone. And between the zones the air recirculation is characterized through the air exchange parameter. By this basic assumption, the equations for the conservation of mass are derived for each zone. These equations are solved by using the computational technique. The language used to develope the program is a VISUAL BASIC. The value of air exchange coefficient($f_12$) is the most difficult to forecast when the concentrations of contaminants in an imperfectly mixed room are estimated by the two-zone model. But, as the value of $f_12$ increases, the air exchange between each zone increases. When the value of $f_12$ is approximately 15, the concentrations in both zone approach each other, and the entire room may be approximately treated as a single well-mixed room. Therefore, this study is available for designing of the ventilation to improve the air quality of indoor environments. Also, the two-zone model produces the theoretical base which may be extended to the theory for the multi-zone model, that will be contributed to estimate the air pollution in large enclosures, such as shopping malls, atria buildings, atria terminals, and covered sports stadia.

  • PDF