• Title/Summary/Keyword: contaminant plume

Search Result 28, Processing Time 0.019 seconds

Evaluation of Biodegradation in an Aquifer Contaminated with Petroleum Hydrocarbon

  • 이지훈;이진용;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.120-123
    • /
    • 2001
  • To evaluate the biodegradability of contaminants in an aquifer, computer modeling with RT3D model (Clement, 1997) was used. The RT3D model simulates the biodegradation of organic contaminants using a number of aerobic and anaerobic electron acceptors. The RT3D model was applied to a well-studied petroleum hydrocarbon plume in a shallow unconfined aquifer in Uiwang, Korea. The results of this study demonstrate tile importance of biodegradation processes in the monitored natural attenuation and in reducing contaminant concentrations in a shallow aquifer. The modeling results tell that the amount of electron acceptors is the key factor affecting biodegradation of TEX, the petroleum hydrocarbon contaminant in shallow groundwater

  • PDF

The Contamination Characteristics of the Nanji Uncontrolled Landfill and its Surrounding Hydrogeologic Environment (난지도 매립지 주변 지하수환경의 오염 특성에 관한 연구)

  • 이철효;한정상
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.3 no.1
    • /
    • pp.27-36
    • /
    • 1996
  • The Nanji landfill is one of the biggest uncontrolled landfill in terms of its size and scale in the world. Because the landfill was constructed on the very vulnerable alluvial deposit installing no pollution control systems such as bottom liner and leachate collection systems, it has caused a serious adverse effect to near-by groundwater and surface water systems. A through remedial investigation comprising plume detection and site-characterization was performed to design the remedial measure. As a part the investigation, comprehensive water quality study was conducted, using ten existing observation wells and one bundle type monitoring well, to determine the contaminant indicators for the plume delineation and to define the vertical and horizontal variation of specific contaminants via distances from the landfill. The results clearly shows that EC and temperature are a good pollution indicators and the vertical concentrations of specific contaminants measured in the fully screened wells are 20 to 90% more than those measured at the same depth in bundle type well which is located just 2 m apart. This paper presents a cost effective monitoring and sampling method to define the contaminant plume and obtain a basic data for leachate control measures.

  • PDF

Variations of Longitudinal Moments for a Contaminant Transport in Physically and Chemically Heterogeneous Media (물리.화학적 불균질 특성을 지닌 매질 내 오염운 이동시 보이는 종적률 변화)

  • Seo, Byong-Min;Jung, Joon-Oh;Kim, Young-Woo;Hwang, Seung-Min
    • The Journal of Engineering Geology
    • /
    • v.19 no.1
    • /
    • pp.81-88
    • /
    • 2009
  • Two dimensional Monte-Carlo simulations of a non-reactive solute plume in isotropic porous media which are physically and chemically heterogeneous are conducted to determine the variations of moment. Retardation factors of 1, 2 and 5 are given to ascertain how the second moments are changed as adsorption increased. Retarded longitudinal second spatial moment, ${Z_{11}}^{'R}(t',l')$, increased during the transport process and as the dimensionless lengths of line plume source, $l_2'$, increased. ${Z_{11}}^{'R}(t',l')$ decreased as the retardation factors increased, and the simulated moments fit well to the first-order analytical results. Retarded longitudinal plume centroid variance, ${Z_{11}}^{'R}(t',l')$, decreased as the dimensionless lengths of line plume source, $l_2'$, increased and as the retardation factor increased. The result indicates that the uncertainty about the plume center decreased, and the ergodic condition for the second spatial moments is far from reaching. Simulated longitudinal one particle displacement covariance, ${Z_{11}}^{'R}(t')$, well consistent with the first-order analytical results for the three degrees of retardation factors of 1, 2 and 5 respectively. It is, consequently, concluded that the retarded longitudinal second moments could be produced by stochastic simulation, and that the first-order analytical results definitely provides very close values of the longitudinal retarded moments.

Determination of Location and Depth for Groundwater Monitoring Wells Around Nuclear Facility (원자력이용시설 주변의 지하수 감시공의 위치와 심도 선정)

  • Park, Kyung-Woo;Kwon, Jang-Soon;Ji, Sung-Hoon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.2
    • /
    • pp.245-261
    • /
    • 2019
  • Radioactive contaminant from a nuclear facility moves to the ecosystem by run-off or groundwater flow. Among the two mechanisms, contaminant plume through a river can be easily detected through a surface water monitoring system, but radioactive contaminant transport in groundwater is difficult to monitor because of lack of information on flow path. To understand the contaminant flow in groundwater, understanding of the geo-environment is needed. We suggest a method to decide on monitoring location and points around an imaginary nuclear facility by using the results of site characterization in the study area. To decide the location of a monitoring well, groundwater flow modeling around the study area was conducted. The results show that, taking account of groundwater flow direction, the monitoring well should be located at the downstream area. Also, monitoring sections in the monitoring well were selected, points at which groundwater moves fast through the flow path. The method suggested in the study will be widely used to detect potential groundwater contamination in the field of oil storage caverns, pollution by agricultural use, as well as nuclear use facilities including nuclear power plants.

Clean-up of Contaminated Groundwater by Permeable Reactive Barrier (투수성 반응벽에 의한 오염지하수 복원효과 분석)

  • 정하익;김상근
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.542-547
    • /
    • 2000
  • It has become interested in the concept of permeable barriers for the containment and/or destruction of contaminated groundwater. The purpose of these trench-like barriers is to provide in situ capture and possibly destruction of the contaminant while preserving groundwater flow to uncontaminated zones. For instance, a trichloreethylene(TCE) plume may be contained by a permeable in which reactive iron reduces TCE to ethylene and ethane, compounds which can be easily biodegraded. The objective of this research is to examine the feasibility of using zero-valent iron as a clean-up media in permeable reactive barrier system. A series of laboratory column tests are performed. The concentration of influent and effluent water and the rate of clean up are analysed from these test results. The experimental result shows that the majority of the contamination in groundwater is removed in the reactor. And it shows the corresponding increase in the concentration of chloride ions through the reactor. Results from this study indicate that permeable reactive barrier containing admixtures of zero-valent iron and other materials can effectively clean up groundwater contaminated with organic compounds.

  • PDF

지하수 모니터링을 통한 오염물질(TEX)의 자연저감능 평가

  • Lee, Min-Hyo;Yoon, Jeong-Gi;Kim, Hyeok;Kim, Mun-Su;Lee, Gil-Cheol;Lee, Seok-Yeong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.179-182
    • /
    • 2002
  • The objective of this study was to evaluate petroleum hydrocarbon degradation processes governing natural attenuation at tile contaminated site and accomplished through conducting on investigation of degradation rate, capacity, and mechanism of the monitored natural attenuation. The monitoring results of the three years indicated that the concentrations of DO, nitrate, and sulfate in the contaminated area were significantly lower than these in the none-contaminated area. The results also showed a higher ferrous iron concentration, a lower redox potential and a neutral pH in the contaminated groundwater, suggesting that biodegradation of TEX is the major on-going process in the contaminated area. However, reduction of TEX in the groundwater was not only biodegradation but also dilution and reaeration during infiltration of uncotaminated surface and groudwater.

  • PDF

Effect of Degradation Processes on Optimal Remediation Design Sorption and First-Order Decay Rate

  • Park, Dong-Kyu;Ko, Nak-Youl;Lee, Kang-Kun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.503-508
    • /
    • 2004
  • Optimal remediation design using the pump and treat(P&T) method and natural attenuation was accomplished in consideration for degradation processes, such as sorption and first-order decay rate. Variation of both sorption and first-order decay rate has influence on design of optimal remediation application. When sorption effect increases, the more pumping rate and pumping wells are required. The location of operated wells is on the centerline of contaminant plume and wells near hot spot are mainly operated when sorption effect increases. The higher of first-order decay rate, the less pumping rate is required. These results show that the degradation processes have to be considered as one of the essential factors for optimal remediation design.

  • PDF

Simultaneous Removal of Cd and Cr(VI) in the Subsurface Using Permeable Reactive Barrier Filled with Fe-loaded Zeolite: Soil Box Experiment (Fe-loaded zeolite로 충진된 투수성 반응벽체를 이용한 지반 내 Cd과 Cr(VI)의 동시제거: 모형 토조 실험)

  • Rhee, Sung-Su;Lee, Seung-Hak;Park, Jun-Boum
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.10
    • /
    • pp.61-68
    • /
    • 2010
  • A pilot-scale model test was performed to estimate the availability of new material, Fe-loaded zeolite, as the filling material in permeable reactive barrier (PRB) against the contaminated groundwater with both Cd and Cr(VI). Aquifer was simulated by filling up a large scale soil tank with sands, and mobilizing the water flow by the head difference of water level in both ends of the tank. Then, the mixture of concentrated Cd and Cr(VI) solution was injected into the aquifer to form a contaminant plume, and its behavior through Fe-loaded zeolite barrier was monitored. The test results showed that Fe-loaded zeolite barrier successfully treated the contaminant plume containing both Cd and Cr(VI) and that the immobilized contaminants in the barrier were not desorbed or released. The results indicated that the Fe-loaded zeolite could be a promising material in PRBs against the multiple contaminants with different ionic forms like Cr(VI) and Cd.

Preliminary Experiments for the Remediation of Trichloroethene-Contaminated Groundwater Using Direct-Current and Zero-Valent Iron (0가 철과 직류전원을 이용한 TCE 오염 지하수의 정화기법 예비조사)

  • Moon, Ji-Won;Moon, Hi-Soo;Roh, Yul;Lee, Suk-Young;Song, Yun-Goo
    • Economic and Environmental Geology
    • /
    • v.34 no.3
    • /
    • pp.307-313
    • /
    • 2001
  • Reactive medium including zero-valent metals such as zero-valent iron ($Fe^0$) degrades chlorinated solvents as a contaminant plume flows through the treatment medium. Although the Feo based reactive barrier has been demonstnlted to be a cost effective for trichloroethenc (TCE)-contaminaled plume remediation, current approach is limited by low process eftlciency and uncertain, effective life of the medium. The objective of this study is to develop an enhanced treatment method of TeE-contaminated groundwater using Feo and direct current. The bench-scale test using flow-through $Fe^0$ reactor column confirmed that the application of direct current with $Fe^0$ is highly effective in enhancing the rate of TeE dechlorination. The dechlorination mechanism appears to be reductive, with the electrons supplied by the iron oxidation and external power supply serving as the additional source of electrons.

  • PDF

A Study on Hydrogeologic, Hydrodispersive Characterization and Groundwater Contamination Assessment of an H-site (H 연구지역의 수리지질-수리분산특성과 지하수 오염가능성 평가연구)

  • Hahn, Jeongsang
    • Economic and Environmental Geology
    • /
    • v.27 no.3
    • /
    • pp.295-311
    • /
    • 1994
  • A comprehensive in-situ tests are performed to define the hydrogeologic and hydrodispersive characteristics such as hydraulic conductivities, longitudinal dispersivity, and average linear velocities as well as conducting flow-net analysis at the study area. The results show that the study area is very heterogeneous so that hydraulic conductivities range from $6.45{\times}10^{-7}$ to $1.15{\times}10^{-5}m/s$ with average linear velocities of 0.34~0.62m/day. Whole groundwater in upper-most aquifer is discharging into the sea with specific discharge rate of $7.2{\times}10^{-3}$ to $1.3{\times}10^{-2}m/day$. The longitudinal dispersivity of the aquifer is estimated about 4.8m through In-situ injection phase test. The area is highly vulnerable to potential contaminant sources due to it's high value of DRASTIC index ranging from 139 to 155 and also under water table condition with very shallow groundwater level. To delineate contaminant plumes of toxic NaOH and carcinogenic benzene when these substances are assumed to be leaked through existing TSDF at the study area by unexpected accidents or spill, Aquifer Simulation Model (ASM) including Flow and Transport Model is used. Te simulated results reveal that the size of NaOH plume after 5 years continuous leak is about $250{\times}100m$ and benzene after 10 years, $490{\times}100m$. When the groundwater is abstracted about 50 days, which is maximum continuously sustained no-precipitation period during 30 years, with pumping rate of $100m^3/day$, THWELL program shows that the groundwater is adversly affected by sea water intrusion.

  • PDF