• Title/Summary/Keyword: contained use

Search Result 922, Processing Time 0.034 seconds

Compressive Strength of CLSM Containing Bottom ash (Bottom ash를 사용한 저강도 고유동 충전재의 강도특성)

  • Won, Jong-Pil;Lee, Yong-Su
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.142-146
    • /
    • 2001
  • This research was undertaken on the use of bottom ash as a fine aggregate in Controlled. Low-strength Material(CLSM). The mixtures contained constant fly ash. And four different level of bottom ash with fly ash contents, 25%, 50%, 75%, 100% are investigated. Mixture proportions were developed for producing CLSM at three 28-day strength levels: removal with tools (less than $7kgf/cm^{2}$), removal by mechanical means (less than $200kgf/cm^{2}$), and removal with power equipment (less than $83kgf/cm^{2}$). To obtain these strengths, cement contents of 30, 60, and $120kg/cm^{3}$ were utilized. The compressive strength properties support the concept that by-product bottom ash can be successfully used in CLSM.

  • PDF

Energy Harvesting from Bio-Organic Substance Using Microbial Fuel Cell and Power Conditioning System (미생물 연료 전지와 전력 조절 시스템을 이용한 생체 유기 물질로부터의 전력 생산)

  • Yeo, Jeongjin;Yang, Yoonseok
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.242-247
    • /
    • 2017
  • This study presents a bio-chemical energy harvesting system which can generate electric power from bioorganic substance contained in vermicompost. It produced electricity by inoculating microbial fuel cell(MFC) with earthworm-composted food waste. The generated electricity was converted into usable voltage level for mobile electronics through power conditioning circuits. The implemented prototype showed $200{\mu}W$ of maximum output electric power, which successfully supplied a beacon device which continuously transmitted data to nearby smartphone without a battery. The proposed system can help develop portable or bio-mimetic energy supply for sustainable use with further improvement.

Inspection of General Use Electric Installation Using Leakage Current Measuring (누설전류측정을 이용한 일반용전기설비의 점검)

  • Lim, Young-Bae;Jung, Jong-Wook;Jung, Jin-Soo;Bae, Seok-Myung;Cho, Seong-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.63-65
    • /
    • 2006
  • A electrical fault is defined as any abnormal condition caused by a reduction in the insulation strength. To define the potential risk of the electric installation, measurement of leakage current has been getting considered, but because the measured leakage current value also contained leakage current by capacitance, the measured value could not be adapted to absolute reference to the installation. Therefore, in this paper, the correlation between the condition of electric installation and leakage current were analyzed. The result focuses on to detect them in a cost efficient way.

  • PDF

Th-determination in Rate Earth Part II Th-determination by the Sebacic Acid Method (稀土類中 토리움의 分離定量에 關하여 (第二報) 세바신酸에 依한 토리움의 分離定量)

  • Choi, Han-Suk;Park, Sun-Ja
    • Journal of the Korean Chemical Society
    • /
    • v.4 no.1
    • /
    • pp.13-14
    • /
    • 1957
  • Th-determination by the sebacic acid method was compared with the hydrogen peroxide method. The former is a little more complicated than the latter in the operation and at the same time it requires careful pH adjustment, but the time needed for determination could be decreased greatly by the former. As a result of the comparison between both methods we confirmed that, within ${\pm}$0.08 ${\%}$ of error, when $ThO_2$ was contained $5{\%}$ in the sample, we could use the sebacic acid method with an half time of that required for the hydrogen peroxide method. Thorium in Monazite sand was also determined by both methods and compared. In the case we found, too, that if we permitted the maximum error of ${\pm}$0.08 ${\%}$, we could prefer the sebacic acid method.

Uncertainty Evaluation of a Multi-axis Force/Moment Sensor and Its Application (다축 힘/모멘트센서의 불확도평가 및 응용에 관한 연구)

  • 김갑순
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.177-180
    • /
    • 2001
  • This paper describes the calibration method and the evaluation method of relative expanded uncertainty for a multi-axis force/moment sensor. This sensor should be calibrated to be use in the industry. Now, the confidence of the calibration result is expressed with interference error. But it is no inaccurate, because an interference error, besides, a reproducibility error of the sensor, a error of this six-axis force/moment sensor calibrator, and so on. Thus, in order to accurately evaluate the relative expanded uncertainty of it, the concept of the uncertainty should be induced, and these errors must be contained in the relative expanded uncertainty. In this paper, the calibration method is exhibited and the evaluation method of the relative expanded uncertainty is also exhibited. And, a six-axis force/moment sensor was calibrated and the relative expanded uncertainty was evaluated.

  • PDF

Chloride ion and Carbonation Resistance of the Cement Mortar admixed with Waste Phosphogypsum (폐석고를 혼입한 모르타르의 염화물 이온 및 중성화에 대한 저항성)

  • An, Yang-Jin;Mun, Kyoung-Ju;Soh, Yang-Seob
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.727-730
    • /
    • 2005
  • The purpose of this study evaluates possibilities of waste phosphogypsum into concerts by steam curing admixture. The waste phosphogypsum is made use of 4 forms(Dehydrate, $\beta$-Hemihydrate, III-Anhydrite and II-Anhydrite) which were changed to in low temperature of calcination. The penetration depth and compressive strength of cement mortar are investigated to evaluate the chloride ion and carbonation resistance. As a result, chloride ion and carbonation resistance of cement mortar admixed with waste phosphogypsum are more excellent than cement mortar contained OPC alone. The internal pores of cement mortar are decreased by using waste phosphogypsum, because the hydrates of ettringite which is denesified in structure is much formed in early ages at steam curing. These densified effect is concluded with improving the resistance to attack of cement mortar including waste phospogypsum.

  • PDF

The Analysis of Chloride Ion Penetration into a Concrete Structure in Marine Environment (해안환경하에 있는 콘크리트의 염분침투해석)

  • Cho, Sun-Kyu;Jeon, Gui;Shin, Chee-Burm
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.3 s.29
    • /
    • pp.68-74
    • /
    • 1998
  • An increase of concrete construction in marine environments as well as an increasing use of marine aggregate at the mixing stage of concrete has provoked an important problem. A high concentration of chloride ion in the vicinity of steel bars in concrete is the principal cause of premature reinforcement corrosion in concrete structures. In this study, the behavior of chloride ions introduced into concrete from concrete surface by marine evironment was analysed. A mathematical model including the diffusion of chloride ion in aqueous phase of pores, the adsorption and desorption of chloride ions to and from the surface of solid phase of concrete and the chemical reactions of chloride ions with solid phase was presented. Finite element method was employed to carry out numerical analysis. The results of this study may be used to predict the onset of reinforcement corrosion and to identify the maximum limit of chloride ions contained in concrete admixtures.

  • PDF

A Study on the Sterilizer Using the Microwave (마이크로파를 이용한 살균장치에 관한 연구)

  • 김행길;이화용
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.2
    • /
    • pp.479-485
    • /
    • 2000
  • In this study, the chamber size was designed and manufactured so as to make a resonance with microwaves in sterilizing moisture-contained food by making good use of microwaves. When the green-pea jelly which was made and sterilized for experimental usage with no addition of an antiseptic was left in the room temperature for 1 minute, 2 minutes or 3 minutes respectively, resulted in delaying more greatly the procession of change in quality of food for almost 7 to 15 days than in unsterilized food. As a result of experiment conducted above, it is considered to produce good results of decreasing the resource waste and environmental pollution, by lengthening the period of preservation and circulation of food.

  • PDF

Experimetnal Verification on the Utilization of Dredged Material for Concrete Mixture (콘크리트 재료로서의 항만준설토의 활용성에 대한 실험적 평가)

  • Oh, Hong-Seob;Lee, Ju-Won;Kim, Su-Ji
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.237-238
    • /
    • 2010
  • The purpose of this research is to develop the method for the beneficial use of dredged material. In this research, authors investigate the material properties of dredged material contained with dredge material of various contents. The compressive strength of cement mortar with 10% dredged material from the Busan harbor is slightly higher than it of conventional mortar, but, it is to need to further research for developing the application technique on the dredged material as the substitutional material of a sand.

  • PDF

Development of Insulation Degradation Diagnosis System for Electrical Plant

  • Kim, Yi-Gon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.2 no.1
    • /
    • pp.33-37
    • /
    • 2002
  • Insulation aging diagnosis system provides early warning regarding electrical equipment defects. Early warning is very important in that it can avoid great losses resulting from unexpected shutdown of the production line. Since relations of insulation aging and partial discharge dynamics are non-linear. it is very difficult to provide early warning in an electrical equipment. In this paper, we propose the design method of insulation aging diagnosis system that use a electromagnetic wave and acoustic signal to diagnose an electrical equipment. Proposed system measures the partial discharge on-line from DAS(Data Acquisition System and acquires 2D patterns from analyzing it. For filtering the noise contained in sensor signals we used ICA algorithms. Using this data, we design of the neuro-fuzzy model that diagnoses an electrical equipment and is investigated in this paper. Validity of the new method is asserted by numerical simulation.