• Title/Summary/Keyword: contact ratio

Search Result 1,195, Processing Time 0.03 seconds

Study on Shift characteristic of Small reducer using Eccentric arm (편심캠을 이용한 소형감속기의 변속특성에 관한 연구)

  • Youm, Kwang-Wook;Ham, Seong-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.609-614
    • /
    • 2017
  • In this study, a new type of eccentric cam was used for the development of a small size reducer with a two-shift reduction ratio while maintaining the same volume as the existing one-shift speed reducer. Therefore, a two-shift speed reducer was designed using the concept of a continuously variable transmission applied to automobiles. The cam was designed to have an eccentric shape with a $180^{\circ}$ phase difference to act as a tensioner to minimize slip by squeezing the V-belt connected to the deceleration pulley and the acceleration pulley, respectively. The cam was designed to have a diameter of 35mm and an outer diameter of 18mm so that the outer portion of the v-belt could contact the cam perfectly. A pulley with a diameter of 50.8mm was installed on the low speed pulley input shaft for deceleration and a pulley with a diameter of 76.2mm was provided on the output shaft. In the high-speed pulley for acceleration, a pulley with a diameter of 76.2mm is provided on the input shaft, and a pulley with a diameter of 50.8mm is provided on the output shaft. Based on the design details, the power transmission efficiency test and the heating characteristics of the transmission were tested to verify the feasibility. In addition, through validation, the suitability of the reducer was demonstrated.

A Study of the Chewing Patterns in Patients with Temporomandibular Disorders by Electrognathography (Electrognathography를 이용한 측두하악장애환자의 저작양태에 관한 연구)

  • Moon-Gyu Kim;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.291-306
    • /
    • 1995
  • Mandibular movement is composed of border movement and functional movement. Border movement such as maximal mouth opening, hinge opening ad lateral eccentric movement has good reproducibility, but functional movement such as chewing, swallowing and speech has also reproducibility. Especially for chewing movement, individual reproducibility has been confirmed by many studies. Study of chewing pattern is still in controversy. In new approach for raising the diagnostic value, numeric parameters and morphologic characteristics could be used for evaluation of chewing pattern. This study was performed to investigate the differences between chewing pattern in controls and in patients with temporomandibular disorders. Sixty-three patients with temporomandibular disorders participated in this study, and they were divided into unilaterally affected subjects or bilaterally affected subjects. Then unilaterally affected subjects were classified into closed lock group, disk displacement with reduction group, and degenerative joint disease group. For recording of chewing pattern, subjects were asked to chew one piece of presoftened chewing gum on both sides, and the chewing movement was recorded with the Electrognatho- Graphy(Bio-Research Associates Inc., U.S.A.). Tooth contact pattern for occlusal stability (Total left-right statistics )was also recorded with T-Scan(Tekscan Co., U.S.A.). The dta related to chewing pattern and total left-right statistics were statistically analyzed by SAS/stat program. The obtained results were as follows : 1. In patient group, mean value of A-P distance and the ratio of A-P distance to vertical distance were larger than control group, but the value of lateral distance in affected side and the closing velocity in unaffected side were smaller than that of control group, respectively. 2. In case of unilateral affected patients, chewing pattern of other side had tendency to restricted movement and slow velocity in closed lock group or degenerative joint disease group than control group or disk displacement with reduction group. 3. In bilateral degenerative joint disease patients, contralateral side had tendency to large range of motion and slow chewing velocity than preferred chewing side. 4. The patients with restricted mouth opening below than 35mm had higher value of total left-right statistics than patient group mouth opening above 35mm. Also closed lock group had higher total left-right statistics than disk displacement with reduction group, degenerative joint disease group and control group. 5. There was some difference in morphologic characteristics of chewing pattern between in control group and in affected side of unilateral patient group, but no difference between control group and unaffected side of unilateral patient group. 6. There were positive correlations between vertical distance and A-P distance, between vertical distance and chewing velocity, between A-P distance and chewing velocity, and between opening velocity and closing velocity in unilateral affected patients.

  • PDF

Development of Epoxy Based Stretchable Conductive Adhesive (신축 가능한 에폭시 베이스 전도성 접착제 개발)

  • Nam, Hyun Jin;Lim, Ji Yeon;Lee, Chang Hoon;Park, Se-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.3
    • /
    • pp.49-54
    • /
    • 2020
  • To attach a stretchable/flexible electrode to something or something to on electrode, conductive adhesives must be stretchable/flexible to suit the properties of the electrode. In particular, conductive adhesive require durability and heat resistance, and unlike conventional adhesives, they should also have conductivity. To this end, Epoxy, which has good strength and adhesion, was selected as an adhesive, and a plasticizer and a reinforcement were mixed instead of a two-liquid material consisting of a conventional theme and a hardener, and a four-liquid material was used to give stretchability/flexibility to high molecules. The conductive filler was selected as silver, a material with low resistance, and for high conductivity, three shapes of Ag particles were used to increase packing density. Conductivity was compared with these developed conductive adhesives and two epoxy-based conductive adhesives being sold in practice, and about 10 times better conductivity results were obtained than products being actually sold. In addition, conductivity, mechanical properties, adhesion and strength were evaluated according to the presence of plasticizers and reinforcement agent. There was also no problem with 60% tensile after 5 minutes of curing at 120℃, and pencil hardness was excellently measured at 6H. As a result of checking the adhesion of electrodes through 3M tape test, all of them showed excellent results regardless of the mixing ratio of binders. After attaching the Cu sheet on top of the electrode through conductive adhesive, the contact resistance was checked and showed excellent performance with 0.3 Ω.

Robust 1D inversion of large towed geo-electric array datasets used for hydrogeological studies (수리지질학 연구에 이용되는 대규모 끄는 방식 전기비저항 배열 자료의 1 차원 강력한 역산)

  • Allen, David;Merrick, Noel
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.1
    • /
    • pp.50-59
    • /
    • 2007
  • The advent of towed geo-electrical array surveying on water and land has resulted in datasets of magnitude approaching that of airborne electromagnetic surveying and most suited to 1D inversion. Robustness and complete automation is essential if processing and reliable interpretation of such data is to be viable. Sharp boundaries such as river beds and the top of saline aquifers must be resolved so use of smoothness constraints must be minimised. Suitable inversion algorithms must intelligently handle low signal-to-noise ratio data if conductive basement, that attenuates signal, is not to be misrepresented. A noise-level aware inversion algorithm that operates with one elastic thickness layer per electrode configuration has been coded. The noise-level aware inversion identifies if conductive basement has attenuated signal levels so that they are below noise level, and models conductive basement where appropriate. Layers in the initial models are distributed to span the effective depths of each of the geo-electric array quadrupoles. The algorithm works optimally on data collected using geo-electric arrays with an approximately exponential distribution of quadrupole effective depths. Inversion of data from arrays with linear electrodes, used to reduce contact resistance, and capacitive-line antennae is plausible. This paper demonstrates the effectiveness of the algorithm using theoretical examples and an example from a salt interception scheme on the Murray River, Australia.

Postoperative irradiation after implant placement: A pilot study for prosthetic reconstruction

  • Doh, Re-Mee;Kim, Sungtae;Keum, Ki Chang;Kim, Jun Won;Shim, June-Sung;Jung, Han-Sung;Park, Kyeong-Mee;Chung, Moon-Kyu
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.363-371
    • /
    • 2016
  • PURPOSE. On maxillofacial tumor patients, oral implant placement prior to postoperative radiotherapy can shorten the period of prosthetic reconstruction. There is still lack of research on effects of post-implant radiotherapy such as healing process or loading time, which is important for prosthodontic treatment planning. Therefore, this study evaluated the effects of post-implant local irradiation on the osseointegration of implants during different healing stages. MATERIALS AND METHODS. Custom-made implants were placed bilaterally on maxillary posterior edentulous area 4 weeks after extraction of the maxillary first molars in Forty-eight Sprague-Dawley rats. Experimental group (exp.) received radiation after implant surgery and the other group (control) didn't. Each group was divided into three sub-groups according to the healing time (2, 4, and 8 week) from implant placement. The exp. group 1, 2 received 15-Gy radiation 1 day after implant placement (immediate irradiation). The exp. group 3 received 15-Gy radiation 4 weeks after implant placement (delayed irradiation). RESULTS. The bone mineral density (BMD) was significantly lower in the immediate irradiation groups. BMD was similar in the delayed irradiation group and the control group. The irradiated groups exhibited a lower bone-to-implant contact ratio, although the difference was not statistically significant. The irradiated groups also exhibited a significantly lower bone volume and higher empty lacuna count than the control groups. No implant failure due to local irradiation was found in this study. CONCLUSION. Within the limits of this study, the timing of local irradiation critically influences the bone healing mechanism, which is related to loading time of prostheses.

Integration of the 4.5

  • Lee, Sang-Yun;Koo, Bon-Won;Jeong, Eun-Jeong;Lee, Eun-Kyung;Kim, Sang-Yeol;Kim, Jung-Woo;Lee, Ho-Nyeon;Ko, Ick-Hwan;Lee, Young-Gu;Chun, Young-Tea;Park, Jun-Yong;Lee, Sung-Hoon;Song, In-Sung;Seo, O-Gweon;Hwang, Eok-Chae;Kang, Sung-Kee;Pu, Lyoung-Son;Kim, Jong-Min
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.537-539
    • /
    • 2006
  • We developed an 4.5" $192{\times}64$ active matrix organic light-emitting diode display on a glass using organic thin-film transistor (OTFT) switching-arrays with two transistors and a capacitor in each sub-pixel. The OTFTs has bottom contact structure with a unique gate insulator and pentacene for the active layer. The width and length of the switching OTFT is $800{\mu}m$ and $10{\mu}m$ respectively and the driving OTFT has $1200{\mu}m$ channel width with the same channel length. On/off ratio, mobility, on-current of switching OTFT and on-current of driving OTFT were $10^6,0.3{\sim}0.5\;cm^2/V{\cdot}sec$, order of 10 ${\mu}A$ and over 100 ${\mu}A$, respectively. AMOLEDs composed of the OTFT switching arrays and OLEDs made using vacuum deposition method were fabricated and driven to make moving images, successfully.

  • PDF

CdS-Titania-Nanotube Composite Films for Photocatalytic Hydrogen Production (CdS/Titania-나노튜브 복합 막을 이용한 광촉매적 수소제조)

  • Lee, Hyun-Mi;So, Won-Wook;Baeg, Jin-Ook;Kong, Ki-Jeong;Moon, Sang-Jin
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.3
    • /
    • pp.230-237
    • /
    • 2007
  • Titania nanotube(TiNT) and CdS sol were synthesized by hydrothermal reaction under strongly basic condition and by precipitation reaction of $Cd(N0_3)_2$ and $Na_2S$ aqueous solutions, respectively. After preparing a series of CdS-TiNT composite films on $F:SnO_2$ conducting glass with variation of the mole ratio (r) of TiNT/(CdS+TiNT), their visible light absorption, photocatalytic activities for hydrogen production, and the photocurrent generation were examined. In general, this CdS-TiNT series showed lower photocatalytic activities and photocurrent generation under Xe light irradiation compared to their counterparts, i.e., CdS-$TiO_2$ particulate series. It appeared that TiNTs are not so effective photocatalyic material in spite of their larger specific surface areas compared to $TiO_2$ nanoparticles, because they indicate a poor crystallinity and less intimate interaction or contact with CdS particles owing to the tubular morphology and an easy agglomeration among themselves.

The Post Annealing Effect of Organic Thin Film Solar Cells with P3HT:PCBM Active Layer (P3HT:PCBM 활성층을 갖는 유기 박막태양전지의 후속 열처리 효과)

  • Jang, Seong-Kyu;Gong, Su-Cheol;Chang, Ho-Jung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.2
    • /
    • pp.63-67
    • /
    • 2010
  • The organic solar cells with Glass/ITO/PEDOT:PSS/P3HT:PCBM/Al structure were fabricated using regioregular poly (3-hexylthiophene) (P3HT) polymer:(6,6)- phenyl $C_{61}$-butyric acid methyl ester (PCBM) fullerene polymer as the bulk hetero-junction layer. The P3HT and PCBM as the electron donor and acceptor materials were spin casted on the indium tin oxide (ITO) coated glass substrates. The optimum mixing concentration ratio of photovoltaic layer was found to be P3HT:PCBM = 4:4 in wt%, indicating that the short circuit current density ($J_{SC}$), open circuit voltage ($V_{OC}$), fill factor (FF) and power conversion efficiency (PCE) values were about 4.7 $mA/cm^2$, 0.48 V, 43.1% and 0.97%, respectively. To investigate the effects of the post annealing treatment, as prepared organic solar cells were post annealed at the treatment time range from 5min to 20min at $150^{\circ}C$. $J_{SC}$ and $V_{OC}$ increased with increasing the post annealing time from 5min to 15min, which may be originated from the improvement of the light absorption coefficient of P3HT and improved ohmic contact between photo voltaic layer and Al electrode. The maximum $J_{SC},\;V_{OC}$, FF and PCE values of organic solar cell, which was post annealed for 15min at $150^{\circ}C$, were found to be about 7.8 $mA/cm^2$, 0.55 V, 47% and 2.0%, respectively.

Evaluation of Fatigue Degradation in SUS316L Using Nonlinear Ultrasonics (초음파의 비선형 특성을 이용한 SUS316L 재료의 피로 열화 평가에 관한 연구)

  • Choi, Ik-Hwang;Baek, Seung-Hyun;Lee, Tae-Hun;Jhang, Kyung-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • This study evaluated the fatigue degradation in a SUS316L specimen using the nonlinear ultrasonic method. The nonlinearity of the ultrasonic wave was estimated by a relative nonlinear parameter defined as the ratio of the amplitudes for the fundamental wave to the second harmonic wave. In the experiment, a measurement system with contact transducers was constructed; reliable measurements were assured by keeping measurement conditions consistent and reducing extra harmonics generated in the measurement system. Two types of SUS316L specimen were used in experiments; a rotating bar fatigue specimen and a tensile fatigue specimen. The fatigue condition used was high cycle fatigue. The former specimen had a cylindrical shape and was used to observe the change in the nonlinear parameter after fatigue accumulation in a specimen. The latter was a plate-shaped specimen and was used to confirm the change in the nonlinear parameter at the position where the fatigue stress was concentrated. The measured nonlinear parameter showed a strong correlation to the damage level in both fatigue tests.

Socio-economic Status Plays Important Roles in Childhood Cancer Treatment Outcome in Indonesia

  • Mostert, Saskia;Gunawan, Stefanus;Wolters, Emma;van de Ven, Peter;Sitaresmi, Mei;van Dongen, Josephine;Veerman, Anjo;Mantik, Max;Kaspers, Gertjan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6491-6496
    • /
    • 2012
  • Background: The influence of parental socio-economic status on childhood cancer treatment outcome in low-income countries has not been sufficiently investigated. Our study examined this influence and explored parental experiences during cancer treatment of their children in an Indonesian academic hospital. Materials and Methods: Medical charts of 145 children diagnosed with cancer between 1999 and 2009 were reviewed retrospectively. From October 2011 until January 2012, 40 caretakers were interviewed using semi-structured questionnaires. Results: Of all patients, 48% abandoned treatment, 34% experienced death, 9% had progressive/relapsed disease, and 9% overall event-free survival. Prosperous patients had better treatment outcome than poor patients (P<0.0001). Odds-ratio for treatment abandonment was 3.3 (95%CI: 1.4-8.1, p=0.006) for poor versus prosperous patients. Parents often believed that their child's health was beyond doctor control and determined by luck, fate or God (55%). Causes of cancer were thought to be destiny (35%) or God's punishment (23%). Alternative treatment could (18%) or might (50%) cure cancer. Most parents (95%) would like more information about cancer and treatment. More contact with doctors was desired (98%). Income decreased during treatment (55%). Parents lost employment (48% fathers, 10% mothers), most of whom stated this loss was caused by their child's cancer (84% fathers, 100% mothers). Loss of income led to financial difficulties (63%) and debts (55%). Conclusions: Treatment abandonment was most important reason for treatment failure. Treatment outcome was determined by parental socio-economic status. Childhood cancer survival could improve if financial constraints and provision of information and guidance are better addressed.