• Title/Summary/Keyword: contact point(CP)

Search Result 6, Processing Time 0.017 seconds

Reducing the Non Grinding Time in Grinding Operations(1st Report) -Reducing the Air Grinding time using Sound Sensor- (연삭가공에 있어 비가공 시간 단축에 관한 연구(I) -음향센서를 이용한 공연삭 시간의 단축-)

  • KIM, Sun Ho;AHN, Jung-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.5
    • /
    • pp.85-91
    • /
    • 1997
  • Air grinding time in grinding process has a great effect on its efficiency due to low feedrate. This paper presents a reduction methos of air grinding time in cylindrical plunge grinding operation. Tje reduction of air grinding time is accomplished by finding the distance between contact point and rising point of ultra- sonic signal of the grinding wheel to workpiece. It uses a variation of sound signal generated by the flow of coolant when the grinding wheel approaches to workpiece. The ultrasonic sensor with 23 kHz center fre- quency and 8 kHz bandwidth is used to find the nearest approaching point(NAP). Monitoring and control system of the grinding conditions is implemented with CNC controller to control feedrate override and ultrasonic sensor to find NAP. The experimental result shows that the ultrasonic signal is a good measure- ment to find NAP. But it needs the considerations for the effect of the relationship between flowrate of coolant and diameter of workpiece.

  • PDF

Analysis of the embrasure dimensions between maxillary central incisors in relation to the topography of the interdental papilla

  • Kim, Sun-A;Choi, Seung-Suk;Byun, Soo-Jung;Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.6
    • /
    • pp.273-278
    • /
    • 2011
  • Purpose: To analyze the dimensions of the embrasure space between the maxillary central incisors as potential factors influencing interdental papilla fill and height. Methods: The embrasure dimensions between the maxillary central incisors of 100 subjects (40 females/60 males) were assessed with clinical, study model, and radiographic examinations. Variables of the complete and deficient papilla fill groups were compared. Multiple regression analyses were performed to investigate potential influence of the distance between the contact point and bone crest (CP_BC), horizontal interdental distance (HID), and facio-lingual thickness (FLT) at the papilla base on complete/deficient papilla fill and papilla height (PH). Results: CP_BC was the only variable that showed a significant difference between the complete and deficient papilla groups (P<0.05). When the CP_BC was less than 5 mm, the embrasure spaces between the maxillary central incisors were completely filled with interdental papilla. Multiple regression analyses revealed that a significant predictor for complete/deficient papilla fill was CP_BC, and significant predictors for PH were CP_BC and HID (P<0.05). Conclusions: The chances of complete papilla fill increased as CP_BC decreased, while PH increased as CP_BC and HID increased. However, the FLT of the papilla base did not appear to affect papilla fill or PH. From an esthetic perspective, CP_BC as well as HID should be considered as factors influencing the topography of interdental papilla.

The association between radiographic embrasure morphology and interdental papilla reconstruction using injectable hyaluronic acid gel

  • Lee, Won-Pyo;Seo, Yo-Seob;Kim, Hee-Jung;Yu, Sang-Joun;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.4
    • /
    • pp.277-287
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the clinical efficacy of enhancing deficient interdental papilla with hyaluronic acid gel injection by assessing the radiographic anatomical factors affecting the reconstruction of the interdental papilla. Methods: Fifty-seven treated sites from 13 patients (6 males and 7 females) were included. Patients had papillary deficiency in the upper anterior area. Prior to treatment, photographic and periapical radiographic standardization devices were designed for each patient. A 30-gauge needle was used with an injection-assistance device to inject a hyaluronic acid gel to the involved papilla. This treatment was repeated up to 5 times every 3 weeks. Patients were followed up for 6 months after the initial gel application. Clinical photographic measurements of the black triangle area (BTA), height (BTH), and width (BTW) and periapical radiographic measurements of the contact point and the bone crest (CP-BC) and the interproximal distance between roots (IDR) were undertaken using computer software. The interdental papilla reconstruction rate (IPRR) was calculated to determine the percentage change of BTA between the initial and final examination and the association between radiographic factors and the reconstruction of the interdental papilla by means of injectable hyaluronic acid gel were evaluated. Results: All sites showed improvement between treatment examinations. Thirty-six sites had complete interdental papilla reconstruction and 21 sites showed improvement ranging from 19% to 96%. The CP-BC correlated with the IPRR. More specifically, when the CP-BC reached 6 mm, virtually complete interdental papilla reconstruction via injectable hyaluronic acid gel was achieved. Conclusions: These results suggest that the CP-BC is closely related to the efficacy of hyaluronic acid gel injection for interdental papilla reconstruction.

Analysis of Factors Affecting Smart HACCP Utilization: Job Performance, Job Satisfaction, and Job Stress among School Food Service Employees in Gyeonggi-do and Incheon (경기ㆍ인천지역 학교급식 조리종사원의 스마트 HACCP 사용의 직무수행도, 직무만족도, 및 직무스트레스에 미치는 요인 분석)

  • So Yeon Park;Chan Yoon Park
    • Journal of the Korean Dietetic Association
    • /
    • v.30 no.2
    • /
    • pp.95-111
    • /
    • 2024
  • The Smart Hazard Analysis Critical Control Point (HACCP) management system, which integrates information technology (IT) to automate and analyze big data, has been introduced into school food services. This study investigated the job performance, job satisfaction, and job stress of employees in school food services using Smart HACCP. Data were collected via questionnaires from 350 employees in school food services who utilized Smart HACCP and worked in Gyeonggi-do or Incheon. The questionnaire included general information, workplace characteristics, HACCP education status, job performance, and job satisfaction according to the use of Smart HACCP, and general job stress. The responses showed that 92.3% of the participants had received HACCP education in the workplace, and 66.6% understood the content of the education. Among the HACCP process stages, CCP2 (Food Handling and Cooking) and CCP3 (Cooking Completion and Distribution) were the stages at which all participants were using Smart HACCP. CCP3 had the highest percentage (61.4%) of participants who experienced feeling the maximum reduction in their tasks by using Smart HACCP. The Smart HACCP job performance at CCP1 (Inspection) and Smart HACCP job satisfaction were higher in workplaces with 6~10 employees, compared to those with 10≤ employees (both P<0.05). The Smart HACCP job performances at of CP1 (Refrigeration and Freezer Temperature Management) and CP2 (Cleaning and Disinfection of Food Contact Surfaces) were significantly affected by the work area. General job stress was significantly higher in cooks than in cook practitioners, higher in employees with cook certification than in those without it, and higher in employees with work experience (<1 year), compared to those with 5~10 years or 10~15 years' experience. In conclusion, employees' job performance and satisfaction with Smart HACCP need to be enhanced to improve hygiene in school food service. This requires the effective management of their job stress.

A STUDY ON SURFACE ROUGHNESS OF COMPOSITE RESINS AFTER FINISHING AND POLISHING -an Atomic Force Microscope study (연마방법에 따른 복합레진의 활택도에 관한 연군 -Atomic Force Microscope를 이용한 연구)

  • Kim, Hyeong-Seob;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.719-741
    • /
    • 1997
  • This study was undertaken to compare by Atomic Force Microscope the effects of various finishing and polishing instruments on surface roughness of filling and veneering composite resins. Seven composite resins were studied : Silux Plus (3M Dental Products, U.S.A.), Charisma (Heraeus Kulzer, Germany), Prisma THP (L.D.Caulk, Dentsply, U.S.A.), Photoclearfil (Kuraray, Japan), Cesead (Kuraray, Japan), Thermoresin LC (GC, Japan), Artglass (Heraeus Kulzer, Germany). Samples were placed and polymerized in holes (2mm thick and 8.5mm in diameter) machined in Teflon mold under glass plate, ensuring excess of material and moulded to shape with polyester matrix strip. Except control group (Polyester matrix strip), all experimental groups were finished and polishied under manufacturer's instructions. The finishing and polishing procedure were : carbide bur (E.T carbide set 4159, Komet, Germany), diamond bur (composite resin polishing bur set, GC, Japan), aluminum-oxide disc (Sof-Lex Pop-On, 3M Dental Products, U.S.A.), diamond-particle disc (Dia-Finish, Renfert Germany), white stone bur & rubber point( composite finishing kit, EDENTA, Swiss), respectively. Each specimens were evaluated for the surface roughness with Atomic Force Microscope (AutoProbe CP, Park Scientific Instruments, U.S.A.) under contact mode and constant height mode. The results as follows : 1. Except Thermoresin LC, all experimental composite resin groups showed more rougher than control group after finishing and polishing(p<0.1). 2. A surface as smooth as control group was obtained by $Al_{2}O_{3}$ disc all filling composite resin groups except Charisma and all veneering composite resin groups except Thermoresin LC(p<0.05). 3. In case of Thermoresin LC, there were no statistically significant differences before and after finishing and polishing(p>0.1). 4. Carbide bur, diamond bur showed rough surfaces in all composite resin groups, so these were inappropriate for the final polishing instruments.

  • PDF

AN ELECTROCHEMICAL STUDY ON THE CORROSION RESISTANCE OF THE VARIOUS IMPLANT METALS (수종 임플랜트 금속의 내식성에 관한 전기화학적 연구)

  • Jeon Jin-Young;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.423-446
    • /
    • 1993
  • Titanium and its alloys are finding increasing use in medical devices and dental implants. The strong selling point of titanium is its resistance to the highly corrosive body fluids in which an implant must survive. This corrosion resistance is due to a tenacious passive oxide or film which exists on the metal's surface and renders it passive. Potentiodynamic polarization measurement is one of the most commonly used electro-chemical methods that have been applied to measure corrosion rates. And the potentiodynamic polarization test supplies detailed information such as open circuit, rupture, and passivation potential. Furthermore, it indicates the passive range and sensitivity to pitting corrosion. This study was designed to compare the corrosion resistance of the commonly used dental implant materials such as CP Ti, Ti-6A1-4V, Co-Cr-Mo alloy, and 316L stainless steel. And the effects of galvanic couples between titanium and the dental alloys were assessed for their useful-ness-as. materials for superstructure. The working electrode is the specimen , the reference electrode is a saturated calomel electrode (SCE), and the counter electrode is made of carbon. In $N_2-saturated$ 0.9% NaCl solutions, the potential scanning was performed starting from -800mV (SCE) and the scan rate was 1 mV/sec. At least three different polarization measurements were carried out for each material on separate specimen. The galvanic corrosion measurements were conducted in the zero-shunt ammeter with an implant supraconstruction surface ratio of 1:1. The contact current density was recorded over a 24-hour period. The results were as follows : 1. In potential-time curve, all specimens became increasingly more noble after immersion in the test solution and reached between -70mV and 50mV (SCE) respectively after 12 hours. 2. The Ti and Ti alloy in the saline solution were most resistant to corrosion. They showed the typical passive behavior which was exhibited over the entire experimental range. Therefore no breakdown potentials were observed. 3. Comparing the rupture potentials, Ti and Ti alloy had the high(:st value (because their break-down potentials were not observed in this study potential range ) followed by Co-Cr-Mo alloy and stainless steel (316L). So , the corrosion resistance of titanium was cecellent, Co-Cr-Mo alloy slightly inferior and stainless steel (316L) much less. 4. The contact current density sinks faster than any other galvanic couple in the case of Ti/gold alloy. 5. Ag-Pd alloy coupled with Ti yielded high current density in the early stage. Furthermore, Ti became anodic. 6. Ti/Ni-Cr alloy showed a relatively high galvanic current and a tendency to increase.

  • PDF