• Title/Summary/Keyword: contact center

Search Result 1,824, Processing Time 0.028 seconds

Surface Dose Evaluation According to the Environment Around the Patient after Nuclear Medicine Examination (핵의학 검사 후 환자의 주위 환경에 따른 표면 선량 평가)

  • Lee, Young-Hee;Park, Jae-Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.943-948
    • /
    • 2021
  • The purpose of this study was to investigate changes in surface dose due to increased scattering of gamma rays from patients injected with 99mTc and 18F, which are radioactive isotopes, in close contact with materials with high atomic number such as the walls of the stable room. Prepare 99mTc and 18F by injecting 20 and 10 mCi respectively into the NEMA phantom, and then measuring the surface dose for 60 minutes by positioning the phantom at a height of 1 m above the surface, at a distance of 0, 5 and 10 cm from the wall, and at the same location as the phantom facing the wall. Each experiment was repeated five times for reproducibility of the experiment and one way analysis of variability (ANOVA) was performed for significance testing and Tukey was used as a post-test. The study found that surface doses of 220.268, 287.121, 243.957, and 226.272 mGy were measured at 99mTc, respectively, in the case of empty space and in the case of 0, 5 and 10 cm, while those of 18F were measured at 637.111, 724.469, 657.107, and 640.365 mGy, respectively. In order to reduce changes in surface dose depending on the patient's location while waiting, it is necessary to keep the distance from the ground or the wall where the patient is closely adhered to, or install an air mattress, etc., to prevent the scattered lines as much as possible, considering the scattered lines due to the wall etc. in future setup of the patient waiting room and safety room, and in addition to the examination, the external skin width may be reduced.

Effect of Wet Milling on Scum Generation and Solubilization in Batch Ozone Reaction Using Digested Sludge (소화슬러지를 이용한 회분식 오존반응 시 습식분쇄가 스컴 생성과 가용화에 미치는 영향)

  • Hong, Seong-Min;Lee, Dong-Hoon;Kim, Choong-Gon;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.2
    • /
    • pp.13-18
    • /
    • 2019
  • Sewage sludge treatment is increasing every year due to improvement of living and urbanization. However, interest in anaerobic digestion which is one of the recycling technology. There is anaerobic digestion of increasing due to limitations of ocean dumping and final disposal. But, the limit of anaerobic digestion efficiency due to the advanced treatment of sewage has been limited, and studies for solubilization technology have been actively conducted. Therefore, in this study, we aimed to investigate the variation of generation of scum and the solubilization efficiency in the application of pre-treatment of ozone reaction and the change of properties of digested sludge with wet milling. There are results of VS/TS increased by 4.4% and $SCOD_{cr}/TCOD_{cr}$ increased by 9.4% by wet milling alone. In addition, the increase of the specific surface area due to which the reduction of the particle size of the solid content of the sludge in the ozone reaction caused by wet milling decreased the generation rate of scum at 14.3% and increased VS/TS at 2.1%, compared with the ozone reaction alone. From these results, it is expected that the application of wet milling can be increased the contact efficiency with solids in the sludge during ozone reaction with suppress scum and increase the efficiency of the subsequent process in anaerobic digestion.

A Study on Stability according to the Conservation Environment for Fixative of Korean Mural Painting Layers (한국 흙벽화 채색층 고착제의 보존환경에 따른 안정성 연구)

  • Jin, Byung-hyuk;Wi, Koang-chul
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.3
    • /
    • pp.150-171
    • /
    • 2013
  • The most important part of conservation treatment of murals is to preserve them against the risk of a damage by injecting fixative into them when the painting loses its cohesion or powderization of pigments occurred due to occurrence of cracks inside the painting layer. However, studies on the stability of fixative used for painting layers of murals are still insufficient. This study manufactured a mural as a specimen and colored it with four kinds of pigments including oyster shell white, cinnabar, malachite and red clay and applied four kinds of fixative, including, Paraloid $B-72^{(R)}$, Caparol-$binder^{(R)}$, glue and Hydoxypropyl $cellulose^{(R)}$. artificially generated environmental changes in temperature, humidity and ultraviolet rays which may occur after the completion of conservation treatment. Then the changes in physical properties were observed in multifaceted ways such as color stability, contact angle, brilliance, adhesive strength and surface. As a result, this study found that ultraviolet rays and hot?humid environment have a large impact on color stability causing changes in brightness and chroma of all painting layers where the fixative were applied, except for oyster shell white and are considered the main factors of decomposition by accelerating the aging process of fixatives applied. In comparison to the synthetic resins that were also tested in this study, the traditional glue showed satisfactory results in terms of color stability and influence preservation and the hydrophile property. As it showed exceptionally outstanding adhesive strength in all painting layers in the aspect of adhesive strength, it is considered to be highly stabile for the fixation treatment of painting layers of mural.

Analyzing Characteristic of Deterioration Status for Stone Properties in the Tae-Jo Geonwolleung of the Royal Tombs of the Joseon Dynasty (조선왕릉 태조 건원릉 내 석물의 훼손 특성 분석)

  • Lee, Mi Hye;Lee, Myeong Seong;Chun, Yu Gun;Lee, Tae Jong
    • Korean Journal of Heritage: History & Science
    • /
    • v.48 no.4
    • /
    • pp.62-73
    • /
    • 2015
  • The Tae-Jo Geonwolleung is the tomb of the first king Tae-Jo of the Joseon Dynasty in the complex of the Royal Tombs of the Joseon Dynasty which is listed in World Heritage, and it contains various types of stone properties. The material of the stone properties consist of a single type of medium-grained biotite granite, however, each properties have different intensity and types in deterioration phenomena according to their locations and purposes. The major deterioration types of the stones are analyzed as physical decomposition and biodeterioration. The exfoliation, breaking-out and granular decomposition are widespread types of the deterioration throughout the entire burial mound stone properties and surrounding stone properties. On the other hands, the colonization of mosses and plants, and contamination by foreign materials are found more frequent in the burial mound stone properties as these stones are in contact with the soil of the tomb mound and moisture in the soil helped biodeterioration. It is suggested that anti-biology treatment and physical reinforcement are applied to the deteriorated stones to prevent further damage on the stone components of the tomb.

Preparation of Polysulfone Composite Ultrafiltration Hollow Fiber Membranes Incorporating Nano-size Fumed Silica with Enhanced Antifouling Properties (나노 크기의 Fumed Silica가 함유된 Polysulfone 한외여과 중공사막 제조 및 내오염성 분석)

  • Kang, Yesol;Lim, Joohwan;Kim, In S.
    • Membrane Journal
    • /
    • v.28 no.6
    • /
    • pp.379-387
    • /
    • 2018
  • This study was conducted to improve the membrane characteristics and performance by increasing hydrophilicity by adding additives to the ultrafiltration polysulfone (PSf) hollow fiber membrane. The mixed matrix membranes (MMMs) were prepared by dispersing 15 nm of fumed silica (FS) in the spinning solution at 0.1, 0.3 and 0.5 wt%. SEM analysis was carried out to confirm the cross-section and surface condition. It was confirmed that mean pore radius of the hollow fiber increased by 4 nm as FS was added. In addition, contact angle measurement was carried out for the hydrophilicity analysis of hollow fiber membranes, and it was confirmed that the hydrophilicity of MMMs were increased by adding of FS. In the case of water permeability, the membrane including FS showed 91~96 LMH and showed 5~11% more increase than PSf membrane. In the antifouling performance test, relative flux reduction ratios of FS mixed hollow fiber membranes were lower than that of PSf membranes, and it was confirmed that increase of hydrophilicity hinders adsorption of hydrophobic BSA on the membrane surface.

Epidemiologic Studies of Reproductive Health in Male Workers (남성 근로자의 생식보건 역학연구)

  • Choi, Byeong Ju;Lee, Sanggil;Kim, Seonggyu;Sung, Jungmin;Ye, Shinhee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.3
    • /
    • pp.202-212
    • /
    • 2021
  • Objectives: The reproductive health of female workers has been extensively investigated in South Korea and other countries worldwide. However, few studies have discussed the reproductive health of male workers. In this study, we reviewed the recent literature that reports on the effects of occupational exposure on the reproductive health of male workers and the health of their children. Methods: In May 2020 we used the PubMed search engine to search the literature over the last 10 years and chose case-control, cohort, and cross-sectional studies and reviews. We selected epidemiological studies that investigated the association between pre-pregnant occupational exposure and the reproductive health of male workers and the health of their children. We excluded case reports, non-epidemiological studies (animal experiments, cellular-level experiments, and similar articles), and studies that described postnatal occupational exposure. Results: We eventually selected 23 studies. The studies that included exclusively male workers reported that those employed in the agricultural sector or those exposed to pesticides showed lower blood levels of reproductive hormones and a high risk of lympho-hematopoietic system cancer in their children. Male workers exposed to complex organic solvents and organic compounds showed a high risk of poor semen quality, increased time to pregnancy, decreased blood levels of reproductive hormones, and a high risk of lympho-hematopoietic system cancer in their children. Male workers employed in occupations that involved significant social contact, or in the leather and livestock industries, and in occupations with high levels of exposure to lead and organic solvents showed a high risk of malignancies, including lympho-hematopoietic system cancer, neuroblastoma, and central nervous system tumors in their children. Studies that investigated both male and female workers reported that children of male smelters showed a high risk of premature birth, and children of male workers exposed to metals showed a high risk of hypospadias and cryptorchidism. Children of male welders and workers employed in the glass, ceramic, and tile industries showed a high risk of premature birth. Conclusion: The findings of this study will serve as basic data for further research on male workers' reproductive health and provide a scientific basis for the development of strategies to protect the reproductive health of males employed in high-risk occupations. Moreover, the results of this study may provide guidelines to improve the understanding of and knowledge on male workers' reproductive health.

Numerical analysis on the estimation of optimal disc cutter angle in transition cutter zone (전이 구간(트렌지션 커터존)의 최적 디스크커터 각도 산정에 관한 수치해석 연구)

  • Lee, Sang Yun;Song, Ki-il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.1
    • /
    • pp.1-12
    • /
    • 2021
  • In the design of a tunnel boring machine (TBM), the excavation efficiency of the equipment depends on the design of the cutter head, which is directly in contact with the ground. Especially, the allocation of disc cutter is crucial issue. Disc cutters can be divided into center cutter zone, inner cutter zone and transition cutter zone depending on where they are placed. Many studies have been conducted to identify optimal cutting conditions for face cutters. However, research to determine the optimal cutting conditions for the transition cutter has been relatively incomplete. In this study, to identify the optimal cutting conditions for the transition cutter, numerical analysis using discrete element method was performed, and the specific energy curve according to the angle between the transition cutters was drawn to find out the optimum cutting conditions. The results show that the angle between the transition cutters showing minimum specific energy in the transition cutter zone is 9°. Transition cutter zone was divided into three sections according to the slope angle of the transition cutter. It is also found that, the greater the slope angle of the transition cutter. This finding shows good agreement with the present design of transition cutter zone.

Radon Hazard Review of Spilled Groundwater and Tap Water in Incheon Metropolitan City Subway Station (인천광역시 지하철 역사 내 지하수 및 수돗물의 라돈 위해성 검토)

  • Lee, Yoo-Sang;Lee, Sang-Bok;Kang, Min-Seok;Jeong, Dong-Ha;Kim, Jin-Hong;Oh, Yoon-Sik;Choi, Se-Rin;Park, Jeong-Soo;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.671-677
    • /
    • 2021
  • Interest in the everyday hazards of radon has recently increased as such, this study attempted to examine the dangers of radon in spilled groundwater by comparing the radon concentrations of the drained groundwater and tap water used in recirculating systems in Incheon Subway restrooms. At five stations of Incheon Subway Line 1 and three stations of Line 2, drained groundwater is recirculated and used in restrooms for toilet flushing. Stations restroom tap water for hand washing that used as a control and the measured values of each were compared. With the cooperation of Incheon Transportation Corporation, samples of spilled groundwater and tap water were collected sealed to prevent contact with the air, and a DURRIDGE RAD7 was used as the experimental equipment. The collected samples were subjected to radial equilibration for approximately 3.5 h, at which the radon concentration reached its maximum, and then calculated as 10 measurements using the RAD7 underwater radon measurement mode. In all eight stations, the radon concentration in tap water was lower than the recommended amount. However, in an average of 7 out of the eight stations, the radon concentration in the effluent groundwater was 100 times higher than that in tap water. Since high radon concentrations in groundwater runoff can be harmful to humans, and there is no accurate standard for radon concentrations in domestic water, it is necessary to continuously monitor radon in water and prepare a guidance of recommended values.

Exposure Assessment of Phthalates from House Dust and Organic Films in the Indoor Environment (실내환경 중 집먼지 및 유기필름에서 기인한 프탈레이트 노출평가)

  • Joen, Jeong-In;Lee, Hye-Won;Lee, Seung-Hyun;Lee, Jeong-Il;Lee, Cheol-Min
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.2
    • /
    • pp.75-85
    • /
    • 2022
  • Background: Various types of semi-volatile organic compounds (SVOCs) exist in the public's living environment. They occur in different forms in terms of their physical and chemical properties and partition coefficients. As a consequence, indoor exposure to SVOCs occurs via various routes, including inhalation of air and airborne particles, skin contact, and dust intake. Objectives: To propose a method for assessing human exposure to the SVOCs occurring in the air of an indoor environment, the concentrations of SVOCs in house dust and organic films measured in a real residential environment were estimated in terms of gas-phase concentration using the partition coefficient. Assessment of inhalation exposure to SVOCs was performed using this method. Methods: Phthalates were collected from samples of house dust and organic films from 110 households in a real residential environment. To perform an exposures assessment of the phthalates present in organic films, gas-phase concentration was calculated using the partition coefficient. The airborne gas-phase concentrations of phthalates from the house dust and organic films were estimated and exposure assessment was performed based on the assumption of inhalation exposure from air. Results: As a result of the exposure assessment for gas-phase phthalates from house dust and organic films, preschool children showed the highest level of inhalation of phthalates, followed by school children, adults, and adolescents. Conclusions: This study includes the limitation of not considering different SVOCs exposure pathways in the health impact assessment, including those of phthalates in the indoor living environment. However, this study has the significance of performing exposure assessment based on exposure to SVOCs present in indoor air that originated from organic films in the indoor residential environment. Therefore, the results of this study should be useful as basic data for exposure and health risk assessments of SVOCs associated with organic films in the indoor environment.

Characterization of Materials and Color Formation for Black Potteries from the Proto-Three Kingdoms Period in Ulsan, Korea (울산지역 원삼국시대 흑색토기의 재질 및 발색 특성)

  • Kim, Su Kyoung;Jang, Sungyoon;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.37 no.2
    • /
    • pp.77-89
    • /
    • 2021
  • In this study, materials and color formation techniques were assessed for black potteries excavated from the Janghyeon-dong, Jungsan-dong and Gyodong-ri sites during the Proto-Three Kingdoms period in Ulsan, Korea. Although the black potteries were black superficially, the inner cores were either black or reddish yellow. Microscopy analysis identified that body clay was used for reddish iron oxide rich soils with quartz, alkali feldspar and mica, along with grains of myrmechite texture. Additionally, as marginal differences exist in the contents of SiO2, Fe2O3 and CaO, the composition of the host rock and clay distributed around the sites was affected. Thus, we can deduce that pottery was made by soiling at a short distance. Raman spectroscopy results revealed that the black layer of the black pottery was used as amorphous combustion carbon. In addition, as a transparent layer of brown lacquer was observed on the substrate that was in contact with the surface layer, the black layer of the pottery induced black color development by a combination of combustion carbon and lacquer. Based on the mineral composition and microtexture of the body clay, the firing temperature of the potteries seemed to range from 750 to 850℃, whereas the lacquer layer was pyrolyzed at 468℃ by thermal analysis. Therefore, a combined layer of combustion carbon and lacquer, which formed the black color, was painted after the body clay was fired.