• 제목/요약/키워드: contact angles

검색결과 443건 처리시간 0.024초

액적 충돌에 동반된 열전달에 관한 수치적 연구 (Numerical Study of Heat Transfer Associated with Droplet Impact)

  • 김성일;손기헌
    • 대한기계학회논문집B
    • /
    • 제28권9호
    • /
    • pp.1093-1100
    • /
    • 2004
  • Numerical analysis of the heat transfer associated with droplet impact on a hot solid surface is performed by solving the equations governing conservation of mass, momentum and energy in the liquid and gas phases. The deformed droplet shape is tracked by a level set method which is modified to achieve volume conservation and to include the effect of contact angle at the wall. The numerical method is validated through the calculations for the cases reported in the literature. Based on the numerical results, the heat transfer rate is found to depend strongly on the droplet spread radius. Decreased advancing/receding contact angles enlarge the splat radius and in turn enhance the wall heat flux. The effect of impact velocity on the droplet spread is reduced as the droplet size decreases. Also, droplet atomization is observed to significantly enhance the heat transfer rate and the effect is pronounced for a smaller size of droplet. An existing model equation to predict the maximum spread radius is improved for application to a micro droplet.

Effects of Oxygen Plasma Treatment on the Wettability of Polypropylene Fabrics

  • Kwon, Young Ah
    • 한국의류산업학회지
    • /
    • 제16권3호
    • /
    • pp.456-461
    • /
    • 2014
  • The objective of this study is to give PP(polypropylene) fabric a good affinity for water. Oxygen plasma was treated to PP fabrics in a commercial glow discharge reactor with different RF power, discharge pressure, and reaction time. The PP fiber surfaces were characterized by the measurement of contact angle and ESCA. A JEOL scanning electron microscope was used to observe the surface morphology of fibers. The spontaneous water uptake amount of PP fabrics was determined by the demand wettability test. To determine the effect of aging on the surface properties of $O_2$ plasma treated PP, all the above measurements of the samples were carried out after 1, 7, 30, 60, and 150 days. The results are as follows. The PP fiber surfaces treated by $O_2$ plasma treatment have a chemical composition that consisted of various oxygen containing polar groups. Consequently, the contact angles of the treated PP fibers decreased, which improved the water uptake rate of PP fabrics. Surface roughness of the treated PP affected the fabric wettabiity as well. Wettability of the treated PP decreased and leveled off with aging. The $O_2$ plasma treatment is a simple and effective method to increase the water uptake rate of PP fabrics.

벨트식 유회수기의 접촉각이 회수율에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effect of Contact Angle for Recovery Rate of a Belt Skimmer)

  • 송동업;윤경환
    • 대한기계학회논문집B
    • /
    • 제22권12호
    • /
    • pp.1702-1714
    • /
    • 1998
  • Removal of spilled oil over the sea and the river has become one of the urgent problems in these days. Removing oil using mechanical devices was recommended because chemical dispersion could cause the secondary contamination in the environment. In the present study a series of experiments were carried out to study the effect of operating conditions, especially, the angle between the belt and the fluid surface on the rate of recovery for the spilled oil using a belt skimmer. Three different types of operation, namely, upward pickup, downward pickup and up-and-downward pickup situations have been investigated for various contact angles, belt speeds and oil thicknesses to find the effects on the recovery rate. The highest rate of oil recovery was found in the case of a contact angle of $45^{\circ}$ and downward pickup. Furthermore, an optimal belt speed was found to reach the saturated recovery rate for a given oil thickness.

실리콘 기판 위에 제작된 나노 크기의 구조물을 가진 그루브 표면이 이방성 젖음에 미치는 영향 (Effects of Grooved Surface with Nano-ridges on Silicon Substrate on Anisotropic Wettability)

  • 이동기;조영학
    • 한국생산제조학회지
    • /
    • 제22권3_1spc호
    • /
    • pp.544-550
    • /
    • 2013
  • A grooved surface with anisotropic wettability was fabricated on a silicon substrate using photolithography, reactive ion etching, and a KOH etching process. The contact angles (CAs) of water droplets were measured and compared with the theoretical values in the Cassie state and Wenzel state. The experimental results showed that the contact area between a water droplet and a solid surface was important to determine the wettability of the water. The specimens with native oxide layers presented CAs ranging from $71.6^{\circ}$ to $86.4^{\circ}$. The droplets on the specimens with a native oxide layer could be in the Cassie state because they had relatively smooth surfaces. However, the CAs of the specimens with thick oxide layers ranged from $33.4^{\circ}$ to $59.1^{\circ}$. This indicated that the surface roughness for a specimen with a relatively thick oxide layer was higher, and the water droplet was in the Wenzel state. From the CA measurement results, it was observed that the wetting on the grooved surface was anisotropic for all of the specimens.

와이퍼 블레이드 고무의 표면 처리에 따른 특성 (The Characteristics of Wiper Blade Rubber with Surface Treatments)

  • 노승백;임미애;박진규;손전익
    • Elastomers and Composites
    • /
    • 제33권1호
    • /
    • pp.27-36
    • /
    • 1998
  • The surface of wiper blade(W/B) rubber was chlorinated by chemical treatment method using the hydrochloric acid(HCI) and sodium hypochlorite(NaOCl). From the results of contact angle measurement, friction coefficient measurement, and ATR-IR spectra, the surface characteristics of chlorinated W/B rubber with time of chlorination were studied. Contact angles for W/B rubber with increasing time of chlorination and chlorine concentration were measured for the water and ethylene glycol. From the results, contact angle fell rapidly with increasing time of chlorination and chlorine concentration, reaching a constant value after about 10min. And the wettability of W/B rubber surface by means of chlorination has been improved. For an unchlorinated W/B rubber, the friction coefficient with time of chlorination decreased from 1.27 to 0.20~0.23 on full chlorination. As the results it was considered that abrasion resistance of W/B rubber surface has been also improved. The values of pH and $Cl^-$ ion concentration in a chlorine treatment solution decreased as the extent of chlorination of W/B rubber surface increased. From the results of ATR-IR spectra, it was observed that C=C double band of W/B rubber surface transformed into C-Cl band, but quantitative determination of the extent of chlorination was not feasible because of the complexity of chlorination reactions.

  • PDF

저온프로세스를 이용한 고분자필름의 플라즈마 표면처리 (Plasma Surface Treatment of the Polymeric Film with Low Temperature Process)

  • 조욱;양성채
    • 한국전기전자재료학회논문지
    • /
    • 제21권5호
    • /
    • pp.486-491
    • /
    • 2008
  • The plasma processing is applied to many industrial fields as thin film deposition or surface treatment technique. In this study, we investigated large-area uniformed surface treatment of PET film at low temperature by using Scanning Plasma Method(SPM). Then, we measured difference and distribution of temperature on film's surface by setting up a thermometer. We studied the condition of plasma for surface treatment by examining intensity of irradiation of uniformed plasma. And we compared contact angles of treated PET film by using Ar and $O_2$ plasma based low temperature. In our result, surface temperature of 3-point of treating is low temperature about $22^{\circ}C$, in other hands, there is scarcely any variation of temperature on film's surface. And by using Ar plasma treatment, contact angle is lower than untreatment or $O_2$ plasma treatment. In case of PET film having thermal weak point, low temperature processing using SPM is undamaged method in film's surface and uniformly treated film's surface. As a result, Ar plasma surface treatment using SPM is suitable surface treatment method of PET film.

Droplet transient migration and dynamic force balance mechanism on vibration-controlled micro-texture surfaces

  • Xu, Jing;Liu, Guodong;Lian, Jiadi;Ni, Jing;Xiao, Jing
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1368-1374
    • /
    • 2018
  • In this paper, forced vibration was used to regulate the droplet migration, fully recording the transient migration of droplets on a micro-textured substrate under the resonance frequency by a high-speed camera. The influence of resonance frequency and dynamic migration characteristics of droplets on the solid micro-texture surface under lateral vibration were researched. The experiment demonstrates that the driving force is caused by the difference between the left and right contact angles made the droplet oscillate and migrate, and as time t increases, the left and right contact points are periodically shifted and the amplitude of migration increases. Therefore, based on the droplet migration behavior and its force balance mechanism, a spring vibration model of migration behavior of the vibrating droplet micro unit was set up to predict the complete trajectory of its migration on a solid surface. The calculation results show that the theoretical displacement is less than the experimental displacement, and the longer the time, the larger the difference. Affected by the vibration, part of the droplet permeates through the micro-texture, resulting in the droplet losing height and the contact angle becoming smaller as well. While the other part of droplet overcomes the internal surface tension to migrate.

경사 돌기 표면의 젖음 특성 평가 (Hydrophobicity Evaluation of Oblique Micro-asperities Structures)

  • 백승익;김태완
    • Tribology and Lubricants
    • /
    • 제39권2호
    • /
    • pp.56-60
    • /
    • 2023
  • In this study, we evaluate the anisotropic flow of droplets according to the directionality of asperities. We manufacture a mold with an inclined hole by adjusting the jig angle using a high-power diode laser. Using the manufactured mold, we prepare specimens for wettability studies by the micro molding technique. We fabricate twelve kinds of surfaces with micro-asperities inclined at 0°, 15°, 30°, and 45° for asperity pitches of 100 ㎛, 200 ㎛, and 300 ㎛. We evaluate the static and dynamic behaviors of the droplets as a function of the asperities pitch and inclination angles. The anisotropic effect increases as the pitch increases between asperities, and the anisotropic flow characteristics increase as the inclination angle of the asperities increases. On the surface with hole pitches of 100 ㎛ and 200 ㎛, the contact angle of the droplet shows high hydrophobicity at approximately 160°, but on the surface with the 300-㎛ hole pitch, the contact angle is approximately 110°, indicating that the hydrophobic effect rapidly reduces. Additionally, when the inclination angle of the asperities is approximately 30°, the left and right contact angle deviations of the droplet are the lowest, showing that the roll-off angle is relatively low.

Carboxymethylcellulose(CMC) 용액과 인공 타액의 점도와 습윤성 (Viscosity and Wettability of Carboxymethylcellulose(CMC) solutions and Artificial Saliva)

  • 박문수;김영준
    • Journal of Oral Medicine and Pain
    • /
    • 제32권4호
    • /
    • pp.365-373
    • /
    • 2007
  • 구강건조증 환자에서 자주 발생하는 구강 연조직과 경조직의 손상은 구강건조증 환자의 삶의 질에 심각한 문제를 일으킨다. 타액선의 기능을 완전히 상실한 구강건조증 환자의 경우 인공타액은 유일한 처치법임에도 불구하고, 현재 통용되고 있는 인공타액은 환자들의 기대치에 비해 많이 부족한 실정이다. 본 연구는 CMC 용액과 인공타액의 점도와 습윤성을 비교함으로써 향후 이상적인 인공타액의 개발에 필요한 정보를 얻고자 시행되었다. CMC를 타액모방완충용액(simulated salivary buffer, SSB)과 증류수에 용해시켜 동물 mucin 용액을 완성한 후, 이를 인체 전타액, 인체 개별 타액선 타액, 그리고 CMC를 주성분으로 하는 인공타액인 Salivart 및 Moi-Stir와 비교 분석하였다. 점도는 cone-and-plate digital viscometer로 검체 당 6개의 전단율에서 측정하였고, 습윤성은 아크릴릭 레진과 Co-Cr alloy 표면 위에서의 접촉각 측정을 통해 평가하여 다음과 같은 결론을 얻었다. 1. CMC 용액의 점도는 CMC 농도에 비례하여 증가하였으며, 0.5% CMC 용액의 점도는 비자극성 전타액의 점도와 유사하였다. 반면에 CMC 용액의 접촉각은 점도와는 반대로 CMC 농도를 증가시킴에 따라 감소하였다. 2. 인체 타액의 점도는 전단율 증가에 따라 감소하는 non-Newtonian fluid의 특성을 나타내었다. 다양한 전단율에서의 평균 점도는 자극성 이하선 타액, 자극성 전타액, 비자극성 전타액, 자극성 악하선-설하선 타액의 순으로 증가하였다. 3. 인체 타액의 접촉각은 점도와는 반대로 자극성 이하선 타액, 자극성 전타액, 비자극성 전타액, 자극성 악하선-설하선 타액의 순으로 감소하였다. 4. 타액모방완충용액에 용해시킨 CMC를 가열하여 변성시킨 경우 점도가 감소하였다 (P < 0.01, 전단율 $90s^{-1}$). 5. 인체 타액의 아크릴릭 레진 표면에서의 접촉각은 인체 타액의 Co-Cr alloy 표면에서의 접촉각보다 유의하게 작은 것으로 나타났다 (P < 0.01). 6. 인체 타액의 아크릴릭 레진 표면에서의 접촉각은 CMC 용액의 아크릴릭 레진 표면에서의 접촉각보다 유의하게 작은 것으로 나타났다 (P < 0.01). 이번 연구에서 CMC 용액의 유동학적 성질을 객관적으로 확인할 수 있었으며, 이상의 결과를 종합하여 보면 CMC는 향후 효과적인 인공타액의 개발에 있어서도 중요한 역할을 수행 할 것으로 기대된다.

액체 침투 특성과 표면 거동 분석을 이용한 사이즈도 자동측정법 (Automatic Test Method of Sizing Degree by Analysis of Liquid Penetration and its Surface Behavior)

  • 이지영;김경철;김철환;;박현진;김성호;심성웅;조후승
    • 펄프종이기술
    • /
    • 제44권2호
    • /
    • pp.18-28
    • /
    • 2012
  • This study was to develop a novel automatic system for measuring St$\ddot{o}$ckigt sizing degree and contact angle at a time. The conventional methods to measure sizing degree had serious problems in obtaining significant differences according to different dosages of a sizing agent, and moreover they disclosed unique limitation due to liquid types used and tester's subjectivity. However, the newly developed system could get reproducible results through total automation of all procedures including liquid dropping, image acquisition and measurement of both St$\ddot{o}$ckigt sizing degree and contact angle. For the St$\ddot{o}$ckigt sizing test, the automatic system could measure sizing degree with more definite differences according to different dosage of AKD, compared to the conventional method. For the contact angle test, the automatic system showed a similar trend to the conventional method but had smaller contact angles due to distortion of an image focus by a sheet curl than the conventional testing machine. The problem from the image out of focus due to specimen curl will be overcome with adopting a new specimen holder for the future system.