• Title/Summary/Keyword: consumption volume

Search Result 573, Processing Time 0.033 seconds

Prediction of compressive strength of slag concrete using a blended cement hydration model

  • Wang, Xiao-Yong;Lee, Han-Seung
    • Computers and Concrete
    • /
    • v.14 no.3
    • /
    • pp.247-262
    • /
    • 2014
  • Partial replacement of Portland cement by slag can reduce the energy consumption and $CO_2$ emission therefore is beneficial to circular economy and sustainable development. Compressive strength is the most important engineering property of concrete. This paper presents a numerical procedure to predict the development of compressive strength of slag blended concrete. This numerical procedure starts with a kinetic hydration model for cement-slag blends by considering the production of calcium hydroxide in cement hydration and its consumption in slag reactions. Reaction degrees of cement slag are obtained as accompanied results from the hydration model. Gel-space ratio of hardening slag blended concrete is determined using reaction degrees of cement and slag, mixing proportions of concrete, and volume stoichiometries of cement hydration and slag reaction. Furthermore, the development of compressive strength is evaluated through Powers' gel-space ratio theory considering the contributions of cement hydration and slag reaction. The proposed model is verified through experimental data on concrete with different water-to-binder ratios and slag substitution ratios.

An Analysis of the Water Supply System with Pressurizing Tank (가압탱크를 이용한 급수시스템의 해석 및 최적화 연구)

  • Lee, T.W.;Kim, T.H.;Choi, D.H.;Kim, S.D.;Kim, J.P.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.93-102
    • /
    • 1994
  • It is the goal of this study to provide the essential data for design and operation of optimum water supply system. Experimental and theoretical analyses have been conducted for various parameters, for example, volume and air percent of pressurizing tank, pump speed and pressure range inside tank, etc. Pressure inside tank with time, flow rate, energy consumption rate and pump operation time have been obtained for design and operating parameters to optimize the components and to establish the operating method of system, and therefore to contribute to the development of technology from a point of view of the improvement of quality, the enhancement of system efficiency and the reduction of construction cost.

  • PDF

Optimal Velocity Profile for Minimum Power Consumption of Korean Total Artificial Heat

  • Chang, Jun-Keun;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.51-64
    • /
    • 1997
  • A dynamic model of the Korean total artificial heart(TAH) which contains a brushless DC motor, all of mechanical components, the pump system with integrated variable volume space(WS) and the circulatory system model including the bronchial circulation were established Two different sets of seven differential equations were separately derived for the left and right systolic period of the Korean TAH operation. Throughout the computer simulation, a full-state fEedback optimal controller that minimizes the power consumption of the Korean TAH and drives the end stage velocity of the energy converter to zero was developed based upon the optimal control theory. Robustness of the controller were also analyzed with the dynamic model of the Korean TAH.

  • PDF

Energy Analysis for Variable Air Volume System (변풍량(變風量)시스템의 에너지해석(解析)에 관(關)한 연구(硏究))

  • Park, B.K.;Cho, D.W.;Shin, H.J.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.5
    • /
    • pp.575-582
    • /
    • 1988
  • This paper presents an energy analysis on the VAV system of 10-story building in Seoul using DOE-2 program and Modified Bin Method. The use of VAV system is an excellent means of saving energy in new buildings and/or retrofit. The fan control techniques considered are cycling, discharge dampers, inlet vanes, and motor speed control. The monthly and annual energy consumption is calculated for fan control techniques, components, and chiller types. The results of annual fan electricity use are compared using DOE-2 and Modified Bin Method, and show fairly good agreement. In addition, factors affecting energy consumption are also described.

  • PDF

An Analysis of Economy Improvement Method and Power Demand Effect when the Battery is Applied to the Building Based on the Measured Energy Consumption (전기저장장치의 건물수용가 적용에 따른 Demand영향 및 경제성 향상방안)

  • Yang, Seung-Kwon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.5
    • /
    • pp.86-93
    • /
    • 2015
  • Recently, ESS became efficient device to stabilize electric power supply system with the development SG related technology. In fact. there are some constraints to supply ESS, because of the high cost and required space, but rapid technology development for ESS will make it more useful soon. So, through this paper, we analyzed the benefit and demand effect when the battery is applied the building based on the measured energy consumption. After that, we got the conclusion that there is a volume limit in ESS application, in a benefit view point. And we realized that there is a demand violation, and the Cost-based BEMS is the best solution to enhance the effect of ESS application.

Effects of propofol-remifentanil versus sevoflurane-remifentanil on acute postoperative pain after total shoulder arthroplasty: a randomized trial

  • Eun Kyung Choi;Saeyoung Kim;Do young Kim
    • Journal of Yeungnam Medical Science
    • /
    • v.40 no.3
    • /
    • pp.247-251
    • /
    • 2023
  • Background: While some evidence indicates that propofol-based anesthesia has less postoperative pain than sevoflurane-based anesthesia, these results are controversial. We compared acute postoperative pain intensity and opioid consumption after total shoulder arthroplasty between propofol-remifentanil (PR) and sevoflurane-remifentanil (SR) anesthesia. Methods: Among 48 patients undergoing shoulder arthroscopic surgery anesthetized with PR or SR, postoperative pain intensity was assessed at 30 minutes and at 2, 6, 12, and 24 hours. The total patient-controlled analgesia volume and number of patients requiring rescue analgesics were assessed. Results: No significant difference in postoperative pain intensity was observed between the two groups. Postoperative opioid consumption and analgesic requirements were also comparable in the first 24 hours after surgery. Conclusion: PR and SR anesthesia for shoulder arthroscopic surgery provide comparable postoperative analgesia results.

Characteristic of Power Consumption for Paddle Impeller in Various Agitated Vessels (여러 가지 교반조에서 Paddle 임펠러의 교반소요동력 특성)

  • Lee, Young Sei;Kato, Yoshihito
    • Applied Chemistry for Engineering
    • /
    • v.16 no.5
    • /
    • pp.698-704
    • /
    • 2005
  • Power consumption for paddle impeller in spherical and cylindrical agitated vessel was measured over a wide range of Reynolds number from laminar to turbulent flow regions. The power correlation was obtained for both spherical and cylindrical vessels, where the apparent diameter of the spherical vessel was equal to the diameter of the cylindrical vessel (height equal to its diameter and had the same volume as the spherical vessel). The power consumption well correlated with the experimental results of Nagata, et al. and Hixson-Baum. Also the critical Reynolds numbers was directly related to the transition coefficient $C_{tr}$ characterizing the transition from a laminar to a turbulent flow region in the correlation proposed here.

Comparison of GHG Emission with Activity Data in Korean Railroad Sector (국내 철도부문의 활동도 자료에 따른 온실가스 배출량 비교 연구)

  • Lee, Jae-Young;Rhee, Young-Ho;Kim, Yong-Ki;Jung, Woo-Sung;Kim, Hee-Man
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.861-864
    • /
    • 2011
  • Since national GHG reduction target by 2020 has been presented in Korea, the role of railroad has been reinforced within transport system due to the allocation of reduction target into sector. So, it is necessary to manage activity data systematically for the calculation of GHG emission in railroad. Now, the activity data of diesel consumption for NIR(National Inventory Report) are provided from oil supply and demand statistics. On the other hands, the activity data collected directly from railroad operating companies are used for GHG & Energy Target Management Act. This study aimed to assess the GHG emissions using two kinds of activity data related to the diesel consumption of railroad in 2009 and 2010. As a result, GHG emissions based on oil supply and demand statistics was 636 thousands ton $CO_{2e}$, but the activity data collected from railroad operating companies showed 649 thousands ton $CO_{2e}$ in 2009. Also, the gap of $CO_{2e}$ emission was increased in 2010. These trends were caused because oil supply and demand statistics included total diesel sales volume during 1 year and the activity data collected from railroad operating companies were the amount of diesel consumption only at railcar operation and maintenance step. In conclusion, it is important to develop the management and verification system of activity data with high reliability to substitute oil supply and demand statistics in railroad sector.

  • PDF

Economic Development, Globalization, Political Risk and CO2 Emission: The Case of Vietnam

  • VU, Thi Van;HUANG, De Chun
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.12
    • /
    • pp.21-31
    • /
    • 2020
  • This study investigates the dynamic effects of economic development, international cooperation, electricity consumption, and political risk on the escalation of CO2 emission in Vietnam. We adopted autoregressive distributed lag model and Granger causality method to examine the interaction between CO2 and various economic and political factors, including foreign direct investment, trade openness, economic growth, manufacture, electricity consumption, and political risk in Vietnam since the economic revolution in 1986. The findings reflect opposite influence between these factors and the level of CO2 in the intermediate and long-term durations. Accordingly, foreign direct investment and CO2 emission have a bidirectional relationship, in which foreign direct investment accelerates short-term CO2 emission, but reduces it in the long run through an interactive mechanism. Moreover, economic development increases the volume of CO2 emission in both short and long run. There was also evidence that political risk has a negative effect on the environment. Overall, the findings confirm lasting negative environmental effects of economic growth, trade liberalization, and increased electricity consumption. These factors, with Granger causality, mutually affect the escalation of CO2 in Vietnam. In order to control the level of CO2, more efforts are required to improve administrative transparency, attract high-quality foreign investment, and decouple the environment from economic development.

A Detailed Analysis of the Part Load Ratio and Cooling Energy Characteristics of Chiller Operation in an Office Building (사무소 건물에서 냉동기의 부분부하율 및 냉방 에너지 성능 특성 분석)

  • Seo, Byeong-Mo;Yu, Byeong-Ho;Lee, Kwang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.567-573
    • /
    • 2015
  • Commercial buildings account for significant portions of the total building energy in Korea, and thus, a variety of research on chiller operation has been carried out. However, most of the studies were carried out on the chiller itself, i.e., the part load ratio characteristics and the corresponding electricity energy consumption patterns were not analyzed in existing studies. In this study, the part load ratio and the operating characteristics of the vapor compression chiller were analyzed within an office building equipped with the conventional variable air volume system. As a result, significant portions of total operating hours, cooling load, and energy consumption turned out to be in the part load ratio range of 0 through 50%. Thus, energy consumption was significantly affected by the chiller COP at low part load conditions, indicating that chiller operation at the part load is an important factor in commercial buildings.