• Title/Summary/Keyword: constant temperature & humidity

Search Result 247, Processing Time 0.022 seconds

An Experimental Study of the Effect of Regeneration Area Ratio on the Performance of Small-Sized Dehumidification Rotor for Residential Usage (재생 면적비가 가정용 소형 제습로터의 성능에 미치는 영향에 관한 실험적 연구)

  • Kim, Nae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.5
    • /
    • pp.277-282
    • /
    • 2015
  • During hot and humid weather, air-conditioners consume a large amount of electricity due to the large amount of latent heat. Simultaneous usage of a dehumidifier may reduce latent heat and reduce electricity consumption. In this study, dehumidification performance was measured for a small-sized dehumidification rotor made of inorganic fiber impregnated with metallic silicate within a constant temperature and humidity chamber. Regeneration to dehumidification depends on ratio, rotor speed, room temperature, regeneration temperature, room relative humidity and frontal velocity to the rotor. Results demonstrate an optimum area ratio (1/2), rotor speed (1.0 rpm), and regeneration temperature ($100^{\circ}C$) to achieve a dehumidification rate of 0.0581 kg/s. As the area ratio increases, the optimum rotation speed and the optimum regeneration temperature also increase. Above the optimum rotor speed, incomplete regeneration reduces dehumidification. Above the optimum regeneration temperature, increased temperature variation between regeneration and dehumidification reduces dehumidification. Dehumidification rate also increases with an increase of relative humidity, dehumidification temperature and flow velocity into the rotor.

Cooling Cycle for Energy Saving (에너지 절약용 냉방사이클)

  • Lee, Hung Joo;Kim, Yong Ku
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.2
    • /
    • pp.116-127
    • /
    • 1989
  • Research on reheating cooling cycle and its practical application have been made to prevent unequalized distribution of temperature and humidity of room due to lack of supply air volume and dewdrops on supply diffusers to be taken place as a result of lower temperature of supply air than that of dew point of room air in cooling cycle of constant air volume, single duct, single zone and draw-through fan type. In view of the fact that human body is insensitive to humidity, it is possible not only to construct the complete non-reheating cooling cycle by increasing the humidity point allowable with the deduction of occupant's sense of pleasantness minimizing, but also to get cooling cycle decreasing the reheating quantity if the humidity exceeds the point allowable. In addition, it is possible to save maximum 8% in electric energy for cooling in cooling system by constructing non-reheating cooling cycle instead of reheating cooling cycle and by increasing the relative humidity of room from 50% to 65% in case efficiency and air pressure of cooling system are low. It is also possible to get an optimum cooling cycle by determining the room humidity in consideration of pleasantness of occupants and conservation rate of electric energy if the cooling capacity, efficiency and total pressure of cooling equipment are fixed.

  • PDF

Investigation of Standard Error Range of Non-Contact Thermometer by Environment (외부 환경 변화에 의한 비 접촉 체온계의 오차 범위 측정)

  • Kim, Jeongeun;Park, Sangwoong;Choi, Heakyung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.307-321
    • /
    • 2020
  • Purpose : A person infected by SARS-CoV2 may present various symptoms such as fever, pain in lower respiratory tract, and pneumonia. Measuring body temperature is a simple method to screen patients. However, changes in the surrounding environment may cause errors in infrared measurement. Hence, a non-contact thermometer controls this error by setting a correction value, but it is difficult to correct it for all environments. Therefore, we investigate device error values according to changes in the surrounding environment (temperature and humidity) and propose guidelines for reliable patient detection. Methods : For this study, the temperature was measured using three types of non-contact thermometers. For accurate temperature measurement, we used a water bath kept at a constant temperature. During temperature measurement, we ensured that the temperature and humidity were maintained using a thermo-hygrometer. The conditions of the surrounding environment were changed by an air conditioner, humidifier, warmer, and dehumidifier. Results : The temperature of the water bath was measured using a non-contact thermometer kept at various distances ranging from 3~10 cm. The value measured by the non-contact thermometer was then verified using a mercury thermometer, and the difference between the measured temperatures was compared. It was observed that at normal surrounding temperature (24 ℃), there was no difference between the values when the non-contact thermometer was kept at 3 cm. However, as the distance of the non-contact thermometer was increased from the water bath, the recorded temperature was significantly different compared with that of mercury thermometer. Moreover, temperature measurements were conducted at different surrounding temperatures and the results obtained significantly varied from when the thermometer was kept at 3 cm. Additionally, it was observed that the effect on temperature decreases with an increase in humidity Conclusion : In conclusion, non-contact thermometers are lower in lower temperature and dry weather in winter.

Drying Characteristics of Mushroom (버섯의 건조특성(乾燥特性)에 관한 연구)

  • Shong, S.K.;Koh, H.K.;Lee, J.H.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.2
    • /
    • pp.112-123
    • /
    • 1994
  • At present, no appropriate drying conditions can be found for the heated-air drying of mushroom in Korea. Usually, mushroom is being dried at the temperature range of 40 to $50^{\circ}C$ until the moisture content reaches 10~13% (wb). However, drying characteristics of the mushroom should be investigated for quality improvement and efficient drying operation of the mushroom. The results of this study may be summarized as follows ; 1. The effect of air temperature on the rate of drying was greater than that of relative humidity for drying of mushroom, and the rate of drying was increased with increase in the air temperature. 2. Drying rate for Shiitake mushroom showed falling-rate period of drying without constant-rate period of drying. Drying rate for Oyster mushroom showed a short constant-rate period at the initial stage of drying process, and followed by falling-rate period of drying. 3. Exponential and App.-Diffusion models were found to describe well the drying process of Shiitake mushroom. Exponential and Thompson models for Oyster mushroom in which Thompson model was the most suitable for Oyster mushroom. 4. The equilibrium moisture content of the mushroom decreased with decrease in the air temperature and increase in the relative humidity. In room condition($20^{\circ}C$, 54% RH), the calculated values of the equilibrium moisture content showed 11.17% for Shiitake mushroom and 13.19% for Oyster mushroom, respectively.

  • PDF

Dimensional Responses of Wood Under Cyclical Changing Temperature at Constant Relative Humidity

  • Yang, Tiantian;Ma, Erni;Shi, Yi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.539-547
    • /
    • 2015
  • To investigate dimensional responses of wood under dynamic temperature condition, poplar (populous euramericana Cv.) specimens, 20 mm in radial (R) and tangential (T) directions with two thicknesses of 4 and 10 mm along the grain, were exposed to cyclic temperature changes in square wave between $25^{\circ}C$ and $40^{\circ}C$ at 60% relative humidity (RH) for three different cycling periods of 6 h, 12 h and 24 h. R and T dimensional changes measured during the cycling gave the following results: 1) Transverse dimensional changes of the specimens were generally square but at an opposite phase and lagged behind the imposed temperature changes. The phase lag was inversely correlated with cycling period, but positively related to specimen thickness, while the response amplitude was directly proportional to cycling period, but in a negative correlation with specimen thickness. 2) The specimens showed swelling hysteresis behavior. The heat shrinkage coefficient (HSC) became greater as cycling period increased or specimen thickness decreased. 3) Dimensional changes of the specimens produced deformation accumulation during repeated adsorption and desorption. The deformation accumulating ratio decreased with an increase in cycling period and specimen thickness. 4) Wood suffered 1.5 times as many dimensional changes per unit temperature variation as per unit humidity variation, and this deformation behaved even more seriously under static condition.

Effects of Hair Style on Human Physiological Response in a Thermal Neutral Environment (쾌적 환경에서 헤어스타일 유형이 인체 생리 반응에 미치는 영향)

  • Kim, Myung-Ju
    • The Korean Journal of Community Living Science
    • /
    • v.21 no.1
    • /
    • pp.117-124
    • /
    • 2010
  • Recently, research on variables associated with hair styles are increasing with the spreading of total coordinated intention in the fields of clothing and cosmetology. In the present study, we focused on examining the skin temperature on the scalp(the vertex, temporal, and occiput), humidity on the occiput, skin temperatures (the forehead, back of ear, back of neck, upper back, abdomen, forearm, hand, thigh, calf, and foot), rectal temperature, total body mass loss by hair styles in a thermal neutral environment. Four young females participated as subjects. For a certain period, each subject had the five different hair styles in a random order: (1)Straight short hair(SS), (2)Perm waved short hair(PS), (3) Straight long hair(SL), (4)Perm waved long hair(PL), (5)Ponytail style(PT). Subjects wore briefs, bra, shirts with long sleeves, long legged training pants, and socks. The environmental variables of a climatic chamber were kept constant at $21{\pm}0.5^{\circ}C$ of air temperature and 55${\pm}$5%RH of air humidity. The results indicated the following: The skin temperature and humidity on the scalp did not show any significant differences among five different hair styles, but straight long hair style(SL)was the highest on the vertex, temporal, and occiput. The temporal skin temperature($29.8\sim30.8^{\circ}C$) was the highest, while the vertex skin temperature($28.7\sim30.1^{\circ}C$) was the lowest. Humidity on the occiput was the highest in the perm waved long hair style(PL). The back of ear skin temperature was significantly lower in the ponytail style(PT) than in the other four hair styles(p<.001). In the straight long hair style(SL), the skin temperature on the back of the neck and on the upper back were significantly higher than those of the other four hair styles(p<.01). Mean skin temperature and rectal temperature had no significant differences among hair styles. Total body mass was the highest in the perm waved long hair style(PL)(p<.05). We acquired fundamental data to enable the improvement of the current hair clinic system, wigs, functional hats, and helmets.

Performance Analysis of a Wet Air-Cycle Refrigeration System (습공기사이클 냉동시스템의 성능해석)

  • Won, Sung Pil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.11
    • /
    • pp.504-511
    • /
    • 2014
  • The objective of this study is to theoretically analyze the performance of an open wet air-cycle refrigeration system, which nowadays is increasingly generating environmental concern. The temperature and relative humidity of the outside air are selected as the most important parameters. As the temperature and relative humidity of the outside air increase, the pressure ratio of the ACM compressor is determined to be nearly constant, the air temperature at the exit of the system increases, and the amount of condensed water, the cooling capacity, the COP, and the total entropy production rate increase overall. The effects of the effectiveness of the heat exchanger and the efficiency of the turbine on the performance are greater than that of the efficiency of the ACM compressor. Also, the performance of the wet air-cycle refrigeration system with two heat exchangers is enhanced, with a high COP and low total entropy production rate, compared to the system with a single heat exchanger.

A Statistical Approach to Examine the Impact of Various Meteorological Parameters on Pan Evaporation

  • Pandey, Swati;Kumar, Manoj;Chakraborty, Soubhik;Mahanti, N.C.
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.3
    • /
    • pp.515-530
    • /
    • 2009
  • Evaporation from surface water bodies is influenced by a number of meteorological parameters. The rate of evaporation is primarily controlled by incoming solar radiation, air and water temperature and wind speed and relative humidity. In the present study, influence of weekly meteorological variables such as air temperature, relative humidity, bright sunshine hours, wind speed, wind velocity, rainfall on rate of evaporation has been examined using 35 years(1971-2005) of meteorological data. Statistical analysis was carried out employing linear regression models. The developed regression models were tested for goodness of fit, multicollinearity along with normality test and constant variance test. These regression models were subsequently validated using the observed and predicted parameter estimates with the meteorological data of the year 2005. Further these models were checked with time order sequence of residual plots to identify the trend of the scatter plot and then new standardized regression models were developed using standardized equations. The highest significant positive correlation was observed between pan evaporation and maximum air temperature. Mean air temperature and wind velocity have highly significant influence on pan evaporation whereas minimum air temperature, relative humidity and wind direction have no such significant influence.

A Study on Heat Transfer Characteristics and Uncertainty of Heat Recovery Ventilator for Various Outdoor Temperature/Humidity Conditions (외기 온습도 조건에 따른 폐열회수 환기장치의 열전달 특성 및 불확실성에 관한 연구)

  • Han, Hwa-Taik;Choo, Youn-Bok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.9
    • /
    • pp.608-613
    • /
    • 2008
  • The purpose of the present paper is to investigate the effect of outdoor weather conditions on the performance of a heat recovery ventilator. Experiments have been performed by varying outdoor temperature/humidity conditions with the indoor conditions fixed at the standard conditions by KARSE. Results indicate humidity efficiency shows larger uncertainties than temperature efficiency in general. With the heat generation by an internal fan removed, the modified temperature efficiency remains almost constant regardless of the indoor-outdoor temperature difference. The enthalpy efficiency can have very large or negative values in case the outdoor conditions are in the vicinity of the indoor enthalpy line. The direction of heat flow, in such a case, can be opposite to that of moisture flow between two air streams. Discussions are included about various interesting features of the psychrometric processes taking place in a heat recovery ventilator.

Moisture Sorption and Desorption Isotherms of Various Leaf Tobaccos (잎담배의 흡습 및 탈습에 관한 연구)

  • 진학용;최승찬;이태호;유광근
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.3 no.1
    • /
    • pp.30-40
    • /
    • 1981
  • The moisture sorption and desorption isotherms of various tobaccos were obtained over a relative humidity range from 0 to 90% at $20^{\circ}C$ and $30^{\circ}C$. The hysteresis effect, constant and rate of moisture sorption and desorption, monomolecular-layer moisture content, and specific surface area were analyzed from the obtained data. The moisture sorption and desorption isotherms showed a different characteristics for different tobacco varieties. At a lower humidity range below 50% RH, Burley tobacco had higher moisture sorption and desorption figures than Hicks and Basma, while, at a higher humidity range above 50% RH, Hicks had higher values than the others. The hysteresis effect of tobacco were greater in an intermediate humidity range (40-70% RN), and Basma showed a greater effect than the others. The sorption and desorption constant (K) increased with temperature, but decreased with RH, and Burley tobacco had larger K values, while Hicks had smaller K values than others. The sorption and desorption rate of Burley tobacco were greater than the other tobaccos. The monomolecular-layer moisture was 27.8 and 51.4mg/g, and the specific surface was 101 and $186m^2/g$, for Basma and Burley, respectively.

  • PDF