Experimental and analytical behaviour of composite slabs

  • Lopes, Emanuel;Simoes, Rui
    • Steel and Composite Structures
    • /
    • 제8권5호
    • /
    • pp.361-388
    • /
    • 2008
  • The Eurocode 4 presents some negative aspects in the design of composite slabs by the m-k Method or the Partial Connection Method. On one hand, the component chemical adherence is not accounted for in the connection between the profiled steel sheet and the concrete. On the other hand, the application of these methods requires some fitting parameters that must be determined by full scale tests. In this paper, the Eurocode 4 methods are compared with a method developed at the Federal Polytechnic School of Lausanne, based on pullout tests, which can be a valid alternative. Hence, in order to calculate the necessary parameters for the three methods, several tests have been performed such as the full scale test described in Eurocode 4 and pull-out tests. This last type of tests is of small dimensions and implicates lower costs. Finally, a full-scale test of a steel-concrete composite slab with a generic loading is presented, with the goal of verifying the analytical formulation.

찬넬형 PC교의 실물실험 연구 (Full Scale Model Test on Channel Type PC Bridge)

  • 구민세;황윤국;조현준;유영찬;김정호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 가을 학술발표회 논문집
    • /
    • pp.89-94
    • /
    • 1990
  • This study was performed to verify the behavior of channel type PC bridge through the full scale model test. It is well known that the behavior of connection is especially important in case of precast multi-beam bridges. In this study, the lateral load distribution capacity was found satisfactory and influenced little either by the type or strength of connections. Analysis results agreed well with test results. Parameter studies were performed based on the test and analysis results.

  • PDF

Cyclic testing of weak-axis steel moment connections

  • Lee, Kangmin;Li, Rui;Jung, Heetaek;Chen, Liuyi;Oh, Kyunghwan
    • Steel and Composite Structures
    • /
    • 제15권5호
    • /
    • pp.507-518
    • /
    • 2013
  • The seismic performance of six types of weak-axis steel moment connections was investigated through cyclic testing of six full-scale specimens. These weak-axis moment connections were the column-tree type, WUF-B type, FF-W type, WFP type, BFP-B type and DST type weak-axis connections. The testing results showed that each of these weak-axis connection types achieved excellent seismic performance, except the WFP and the WUF-B types. The WFP and WUF-B connections displayed poor seismic performance because a fracture appeared prematurely at the weld joint due to stress concentrations. The column-tree type connection showed the best seismic behavior such that the story drift ratio could reach 5%.

실물크기의 H형강 기둥-보 신형상 약축접합부에 대한 구조성능평가 (Performance Evaluation of Full-scale H-shape Beam-to-Column New-Shape Weak Axis Connection)

  • 심현주;조한솔;김대회;김상섭
    • 한국강구조학회 논문집
    • /
    • 제25권3호
    • /
    • pp.233-242
    • /
    • 2013
  • 현재 가장 많이 사용되는 기존 약축접합부는 브라켓 타입으로 기둥과 보를 접합하는 과정에서 수평 스티프너가 필요하며, 기둥과 브라켓의 용접접합으로 인해 용접량이 비교적 많아 접합부에서 취성파괴가 우려된다. 본 논문은 용접플레이트를 사용함으로써 기존 약축접합부가 가지는 문제점에 대한 해결책을 제시할 수 있는 신형상 약축접합부를 제작해 기존 약축접합부 및 표준 약축접합부와 비교하여 구조성능을 평가하였다. 신형상 약축접합부는 H형강 기둥웨브에서 보 단부사이의 거리를 50mm, 100mm, 150mm, 200mm로 하였다. 실험결과 신형상 약축접합부는 H형강 기둥웨브와 보 단부사이의 거리가 150mm일 때 기준 실험값과 가장 비슷한 것으로 나타났으며, 기존 약축접합부와 표준 약축접합부와 비교해 우수한 구조성능을 가지는 것으로 나타났다.

Study on the behavior of beam-column connection in precast concrete structure

  • Kataoka, Marcela N.;Ferreira, Marcelo A.;El Debs, Ana Lucia H.C.
    • Computers and Concrete
    • /
    • 제16권1호
    • /
    • pp.163-178
    • /
    • 2015
  • Due to the increase of the use of precast concrete structures in multistory buildings, this paper deals with the behavior of an specific type of beam-column connection used in this structural system. The connection is composed by concrete corbels, dowels and continuity bars passing through the column. The study was developed based on the experimental and numerical results. In the experimental analysis a full scale specimen was tested and for numerical study, a 3D computational model was created using a finite element analyze (FEA) software, called DIANA. The comparison of the results showed a satisfactory correlation between loading versus displacement curves.

Static behavior of novel RCS through-column-type joint: Experimental and numerical study

  • Nguyen, Xuan Huy;Le, Dang Dung;Nguyen, Quang-Huy
    • Steel and Composite Structures
    • /
    • 제32권1호
    • /
    • pp.111-126
    • /
    • 2019
  • This paper deals with experimental investigation and modeling of the static behavior of a novel RCS beam-column exterior joint. The studied joint detail is a through-column type in which an H steel profile totally embedded inside RC column is directly welded to the steel beam. The H steel profile was covered by two supplementary plates in the joint area in order to avoid the stirrups resisting shear in the joint area. Two full-scale through-column-type RCS joints were tested under static loading. The objectives of the tests were to examine the connection performance and to highlight the contribution of two supplementary plates on the shear resistance of the joint. A reliable nonlinear 3D finite element model was developed using ABAQUS software to predict the response and behavior of the studied RCS joint. An extensive parametric study was performed to investigate the influences of the stirrups, the encased profile length and supplementary plate length on the behavior of the studied RCS joint.

Anchored blind bolted composite connection to a concrete filled steel tubular column

  • Agheshlui, Hossein;Goldsworthy, Helen;Gad, Emad;Mirza, Olivia
    • Steel and Composite Structures
    • /
    • 제23권1호
    • /
    • pp.115-130
    • /
    • 2017
  • A new type of moment-resisting bolted connection was developed for use in composite steel- concrete construction to connect composite open section steel beams to concrete filled steel square tubular columns. The connection was made possible using anchored blind bolts along with two through bolts. It was designed to act compositely with the in-situ reinforced concrete slab to achieve an enhanced stiffness and strength. The developed connection was incorporated in the design of a medium rise (five storey) commercial building which was located in low to medium seismicity regions. The lateral load resisting system for the design building consisted of moment resisting frames in two directions. A major full scale test on a sub-assembly of a perimeter moment-resisting frame of the model building was conducted to study the system behaviour incorporating the proposed connection. The behaviour of the proposed connection and its interaction with the floor slab under cyclic loading representing the earthquake events with return periods of 500 years and 2500 years was investigated. The proposed connection was categorized as semi rigid for unbraced frames based on the classification method presented in Eurocode 3. Furthermore, the proposed connection, composite with the floor slab, successfully provided adequate lateral load resistance for the model building.

플레이트형 에너지 흡수장치를 가지는 기둥-보 접합부에 관한 연구 (A Study on Beam-to-Column Connections with Plate Type Energy Absorption System)

  • 오상훈;박해용
    • 한국강구조학회 논문집
    • /
    • 제25권1호
    • /
    • pp.103-114
    • /
    • 2013
  • 최근 지진동과 같은 강한 수평력 작용시 골조에 작용하는 대부분의 손상을 댐퍼부에 집중시키며 주부재의 재사용을 가능하게 하는 지속가능형 접합부 시스템에 관한 관심이 커지고 있다. 본 연구에서는 이러한 개념을 적용한 새로운 형태의 손상제어형 접합부 시스템을 제안하고 실물대 반복이력실험 및 비선형 유한요소해석을 통하여 제안 시스템의 주요 구조성능을 분석하였다. 분석결과를 통하여 주부재의 손상을 극소화하면서 보의 전소성모멘트 이상을 만족하는 최적의 댐퍼/보 내력비를 도출하였으며 내진접합상세로서의 적용가능성을 확인하였다.

반복재하 실물대 실험에 의한 컬럼-트리(Column-Tree) 형식 철골 모멘트 접합부의 내진거동 연구 (Cyclic Seismic Testing of Full-Scale Column-Tree Type Steel Moment Connections)

  • 이철호;박종원
    • 한국강구조학회 논문집
    • /
    • 제10권4호통권37호
    • /
    • pp.629-639
    • /
    • 1998
  • 본 연구에서는 반복재하 실물대 실험에 의해 철골 모멘트접합부(column-tree 형식)의 내진거동을 평가하였다. 시험체는 $H-600{\times}200$ (보) 및 $H-400{\times}400$ (기둥) 계열의 SS41 (SS400) 압연형강으로 제작되었으며 보에 대한 패널존의 상대강도를 실험의 주요변수로 고려하였다. 본 실험결과에 의할 때 패널존의 강도가 클수록 열등한 내진성능을 보였다. 시험체의 모멘트 접합부에서 접합부의 파괴 이전까지 발휘된 총소성회전각은 1.8 (% rad)에서 3 (% rad) 범위에 있었다. 시험체의 접합부는 보플랜지 열영향부의 파단 또는 기둥플랜지 두께방향의 뽑힘으로 인하여 파괴되었다. 비록 제한된 실험자료이긴 하나 본 연구의 결과는 보에만 항복을 유발하는 것 보다는 패널존의 항복도 허용하는 것이 접합부의 전체적 소성변형능력을 높이는데 유리할 것임을 시사한다. 이러한 실험결과를 역학적으로 설명할 수 있는 모델도 제시하고자 하였다.

  • PDF

강관기둥과 PHC 파일을 연결하는 접합부에 관한 구조성능평가 (Structural Performance Evaluation of Joint between PHC Pile and Steel Tube Column)

  • 김상봉;오진탁;김영식;주영규
    • 한국공간구조학회논문집
    • /
    • 제15권3호
    • /
    • pp.85-93
    • /
    • 2015
  • This paper presents a foundation pile to steel column connection that can resist large magnitude of moment and that can be easy installed. The developed joint has spherical shape and it is given the name HAT joint to mean Hallow half-sphere steel joint. Four types of HAT joints are developed. Namely, H-type, T-type, P-type and K-type. In this paper I will talk about the performance assessment of T-type(Tube Column) and P-type(Pile Column) of HAT joints with finite element analysis and experiment on a full scale model is presented.