• Title/Summary/Keyword: connection socket

Search Result 35, Processing Time 0.02 seconds

Removal torque of a two-piece zirconia abutment with a novel titanium component in an internal connection implant system after dynamic cyclic loading (새로운 타이타늄 구성요소를 사용한 내부연결 임플란트용 지르코니아 지대주의 동적하중 후 나사 제거력)

  • Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.151-155
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate screw removal torque of the two-piece zirconia abutment with the novel titanium component compared to the conventional one-piece titanium abutment in the internal connection implant before and after dynamic cyclic loading. Materials and methods: Two types of the abutment assemblies with internal connection were prepared and divided into the groups; titanium abutment-titanium abutment screw assemblies as control, and zirconia abutment-titanium socket-titanium abutment screw assemblies as experimental group. A total of 12 abutments and implants were used of six assemblies each group. Each assembly was tightened to 30 Ncm. A cyclic load of 300 N at an angle of 30 degrees in reference to the loading axis was applied until one million cycles or failure. The removal torque values (RTVs) of the abutment screws were measured with a digital torque gauge before and after cyclic loading. The RTVs of the pre load and post load were analyzed with t-test, and P-values < .05 were considered statistically significant. Results: The assemblies of both groups survived all after the dynamic cyclic loading test without screw loosening. The statistically significant differences were found between the mean RTVs before and after the cyclic loading in both groups (P < .05). The RTV differences for the control and the experimental group were $-7.25{\pm}1.50Ncm$ and $-7.33{\pm}0.93Ncm$, respectively. Statistical analysis revealed that the RTV differences in both groups were not significantly different from each other (P > .05). Conclusion: Within the limitation of this study, the two-piece zirconia abutment with the titanium component did not show a significant RTV difference of the abutment screw compared to the titanium abutment after dynamic cyclic loading.

Asynchronous Message Pushing Framework between Android Devices using Remote Intent (Remote Intent를 이용한 안드로이드 장치 간 비동기식 메시지 푸싱 프레임워크)

  • Baek, Jihun;Nam, Yongwoo;Park, Sangwon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.2 no.8
    • /
    • pp.517-526
    • /
    • 2013
  • When developing an android mobile application the androids intent is used as a mechanism to send messages between local equipment of androids application inner part and other applications. But the androids intent does not support sending messages via each android products intent. If there is a way to support each androids equipments to send messages, it will be easier to make non-stopping services. Non-stopping service is used when the user is using the android to do word or searching services and suddenly changes to a different android product but still maintains the progress what was currently being done without waiting the programs to be loaded. It is possible to send messages to each android products by using the socket, but the connection must be maintained stably which is the weak point. In this paper, I am suggesting a BRIF(Broadcasting Remote Intent Framework) framework to send messages to different android products. BRIF is a framework that uses the Googles C2DM service which services asynchronous transmissions to different android products. This is organized with the C2DM server, RemoteContext Api, web server and RISP(Remote Intent Service Provider) which is will be easy to be used for the developers since there are no big changes for coding compared to the intent code.

Immediate implant placement in areas of aesthetic priority (상악 전치부에서 단일 치아 발거 후 즉시 임플란트 식립)

  • Lee, Seung-Hoon;Kim, Young-Sung;Kim, Won-Kyung;Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.637-646
    • /
    • 2007
  • Implants placed immediately after tooth extraction have been shown to be a successfully predictable treatment modality. Several clinical papers suggest that placing implants immediately after tooth extraction may provide some advantages: reduction of the number of surgical procedures or patient visits, preservation of the dimensions of alveolar ridge, and shortening of the interval between the removal of the tooth and the insertion of the implant supported restoration. In this case report, three patients received single immediate implant placements to replace a maxillary anterior tooth at the time of extraction. As the three cases were somewhat different, treatment protocols had to be modified as follows: Case 1. Immediate implant placement with healing abutment connection. Case 2. Immediate implant placement with immediate provisionalization. Case 3. Immediate implant placement with Guided Bone Regeneration(GBR). Every implant of these cases was placed in proper position buccolingually, mesiodistally and apicocoronally, The procedures following implantation such as immediate provisionalization and GBR were free of problem. Healing of each case was uneventful. In all cases, treatment outcomes were mostly satisfactory and the results maintained during follow-up periods. However, one case (Case 3) showed some papilla loss due to failure in delicate soft tissue handling during surgery. This papilla loss was compromised by prosthetic means. In conclusion, immediate implant placement in the fresh extraction socket can be a valid and successful option of treatment in aesthetic area. Moreover, this treatment protocol seems to maintain the preexisting architecture of soft and hard tissues in most cases.

A Study of Service Middleware for Application Based on USN/RFID/GPS (USN/RFID/GPS 응용을 위한 서비스 미들웨어 연구)

  • Moon, Kyeung-Bo;Lee, Chang-Young;Kim, Do-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1284-1288
    • /
    • 2008
  • Recently, there is increasing the development requirement of middleware and interface for GPS(Global Positioning System), RFID(Radio Frequency IDentification), sensor networks. GPS supports a useful location based service. RFID supports products logistic and distribution services through the identification. A sensor network collects a context information, such as humidity, temperature and atmospheric pressure. This paper implements and verifies a integrated service middleware for supporting efficiently process of sensing data collected from RFID, GPS and sensor network. This middleware have the temporary store function, the redundancy exclusion function, certification function, the classification function and the database storage function. Additionary, this middleware connects with low-level adaptor using socket interface and supports the high-level application services using database connection. Therefore, user can develop easily various many ubiquitous application system using proposed middleware instead of each RFID middleware, GPS middleware and, middleware based on sensor network.

Prevent Information Leakage of Network Printers using the RAW Protocol (RAW 데이터 통신을 하는 네트워크 프린터의 보안 요구사항 도출)

  • Cho, Han-ik;Jeong, Young-hyeon;Cho, Young-bok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.58-62
    • /
    • 2019
  • The printing environment for output is commonly referred to as computers and printers using local connections in 1: 1 format. However, the local connection environment has spatial, temporal, and financial physical limitations. Therefore, a network-based output environment has been proposed and utilized as a way to supplement this.A network printer receives data in packets for document output, and generally does not support a security protocol. Therefore, when a network printer is used, there is a possibility that the content of a document being printed is stolen by being exposed to a network attack such as a meson attack or spoofing against a printed matter. In this paper, we define and define the requirements to cope with the meson attack on printed materials in a network printer environment where security protocol is not supported.

  • PDF