• Title/Summary/Keyword: conformance test

Search Result 177, Processing Time 0.029 seconds

Development and Verification Methodology for Small Civil Unmanned Aerial Vehicle System based on Open System Architecture (개방형 시스템 아키텍처 기반의 소형 민간 무인항공기 시스템 개발 및 검증 방법)

  • Jo, Hyun-Chul;Park, Keunyoung
    • Journal of Platform Technology
    • /
    • v.8 no.2
    • /
    • pp.32-43
    • /
    • 2020
  • The Unmanned Aerial Vehicle(UAV) system has been mainly used for military domains, but it also widely applied to used in the civilian domains. In civilian domains, low-cost and small-sized UAV systems are mainly applied in various industries. The software that operates UAV systems has a lot of common functions. However, even though there are many common functionalities of the software, changing the devices may cause a problem requiring software modification. These problems degrade interoperability, modularity and portability in UAV systems. In order to solve the problems, an Open System Architecture(OSA) has been proposed. In this paper, we propose a UAV system software architecture based on Future Airborne Capability Environment(FACE) standard. Our system can support UAV systems of various platforms in the civilian domains, which is supplied in small quantity batch production. And it has the advantages of software consolidation and portability. Finally, We describe the development and conformant methodology of the software based on the FACE standard using open development tools.

  • PDF

A Complexity Reduction Method of MPEG-4 Audio Lossless Coding Encoder by Using the Joint Coding Based on Cross Correlation of Residual (여기신호의 상관관계 기반 joint coding을 이용한 MPEG-4 audio lossless coding 인코더 복잡도 감소 방법)

  • Cho, Choong-Sang;Kim, Je-Woo;Choi, Byeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.3
    • /
    • pp.87-95
    • /
    • 2010
  • Portable multi-media products which can service the highest audio-quality by using lossless audio codec has been released and the international lossless codecs, MPEG-4 audio lossless coding(ALS) and MPEG-4 scalable lossless coding(SLS), were standardized by MPEG in 2006. The simple profile of MPEG-4 ALS, it supports up to stereo, was defined by MPEG in 2009. The lossless audio codec should have low-complexity in stereo to be widely used in portable multi-media products. But the previous researches of MPEG-4 ALS have focused on an improvement of compression ratio, a complexity reduction in multi-channels coding, and a selection of linear prediction coefficients(LPCs) order. In this paper, the complexity and compression ratio of MPEG-4 ALS encoder is analyzed in simple profile of MPEG-4 ALS, the method to reduce a complexity of MPEG-4 ALS encoder is proposed. Based on an analysis of complexity of MPEG-4 ALS encoder, the complexity of short-term prediction filter of MPEG-4 ALS encoder is reduced by using the low-complexity filter that is proposed in previous research to reduce the complexity of MPEG-4 ALS decoder. Also, we propose a joint coding decision method, it reduces the complexity and keeps the compression ratio of MPEG-4 ALS encoder. In proposed method, the operation of joint coding is decided based on the relation between cross-correlation of residual and compression ratio of joint coding. The performance of MPEG-4 ALS encoder that has the method and low-complexity filter is evaluated by using the MPEG-4 ALS conformance test file and normal music files. The complexity of MPEG-4 ALS encoder is reduced by about 24% by comparing with MPEG-4 ALS reference encoder, while the compression ratio by the proposed method is comparable to MPEG-4 ALS reference encoder.

Study on the Developing of Evaluation Indicators for Smart City from the Perspective of Digital Social Innovation (디지털 사회혁신관점의 스마트도시 평가지표 설정에 관한 연구)

  • Kim, Yu-Mi;Koo, Ja-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.10
    • /
    • pp.511-521
    • /
    • 2019
  • This study is designed to define the smart city as the platform for digital social innovation, and acquire the evaluation indicator for objectively diagnosing domestic cities from the perspective of the implementation process and capability of smart city and analyze its importance. Through prior studies and in-depth interview with experts, candidate groups for evaluation indicators were acquired and the conformance test(T-test) was conducted to finally select 16 detailed indicators in 4 fields. The importance of the evaluation item was found to be high in the policy and system, followed by innovation infrastructure, citizen's participation and infrastructure. The analysis of the 16 detailed indicators for importance showed that the willingness of conducting the smart city by the head of local government, construction of organization dedicated to the smart city have the highest importance. This may reflect the fact that in domestic cities, the smart city is sponsored by public organizations. The analysis of the importance of expert groups (local government and Private sector groups) found that both groups recognized that politics and systems are important factors but they varied in the recognition of importance in the innovation infrastructure and citizen's participation. This study has implication as the indicator for smart city from the perspective of digital social innovation can be acquired for use of the domestic cities and that it can give basic and objective data for the priority of policies on which the domestic smart cities shall focus.

The Comparison of Effectiveness in Prehospital Protocol Education on CardioPulmonary Resuscitation (심폐소생술에 대한 현장업무 프로토콜 교육 효과 비교)

  • Shin, Sang-Yol;Jung, Ji-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3418-3426
    • /
    • 2009
  • The purpose of this study was to investigate the feasibility of field operation protocol for cardiopulmonary resuscitation(CPR) in person with non-traumatic arrest. This study was performed from May 1 through June 27, 2008, and subjects were 150 students who are attending the department of Emergency Medical Service in J and K universities which located in Jeollabuk-do and Jeollanam-do areas. Practical conformance was verified using by nonequivalent control group pretest-posttest design. This study divided into two groups; experimental group that employed field operation protocol and control group that applied conventional CPR protocol, and comparative analyzed statistically the necessary time of the items of each protocol. The results indicated that each performance time of 18 items was reduced over 3 seconds except 5 items(assessment of consciousness, airway control, two times of artificial respiration, check of circulation, and five cycles of CPR). And time of 6 items(intubation, peripheral intravenous line, reassessment of consciousness, pupil reaction, carotid artery pulse, and vital sign) was minimized more than 60 seconds, and total performing time was shortened 110.85 seconds. The results suggested that total performing time in pre and post test where the protocol was applied for two groups showed a statistically significant decrease(t=-6.580, p=.000). Consequently, field operation protocol for cardiopulmonary resuscitation(CPR) in person with non-traumatic arrest will be a available manual which support prompt and accurate decision making, and improve emergency medical service.

Acoustic outputs from clinical ballistic extracorporeal shock wave therapeutic devices (임상에서 사용중인 탄도형 체외충격파 치료기의 음향 출력)

  • Cho, Jin Sik;Kwon, Oh Bin;Jeon, Sung Joung;Lee, Min Young;Kim, Jong Min;Choi, Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.570-588
    • /
    • 2022
  • We scrutinized the acoustic outputs from the 70 shock wave generators of the 15 product models whose technical documents were available, among the 46 ballistic extracorporeal shock wave therapeutic devices of 11 domestic and 6 foreign manufacturers, approved by the Minster of Food & Drug Safety (Rep. Korea). We found that the acoustic Energy Flux Density (EFD), the most popular exposure parameter, was different by up to 563.64 times among shock wave generators at their minimum output settings and by up to 74.62 times at their maximum settings. In the same product model, the EFD was shown to vary depending on shock wave transmitters by up to 81.82 times at its minimum output setting and by up to 46.15 times at its maximum setting. The lowest EFD 0.013 mJ/mm2 at the maximum output settings was much lower (2.1 %) than the maximum value 0.62 mJ/mm2 at the minimum settings. The Large acoustic output differences (tens to hundreds of times)from the therapeutic devices approved for the same clinical indications imply that their therapeutic efficacy & safety may not be assured. The findings suggest the regulatory authority to revise her guideline to give clearer criteria for clinical approval and equality in performance, and recommend the authority to initiate a post-approval surveillance as well as a test in conformance between the data in technical documents and the real acoustic outputs clinically used.

A Classification Model for Customs Clearance Inspection Results of Imported Aquatic Products Using Machine Learning Techniques (머신러닝 기법을 활용한 수입 수산물 통관검사결과 분류 모델)

  • Ji Seong Eom;Lee Kyung Hee;Wan-Sup Cho
    • The Journal of Bigdata
    • /
    • v.8 no.1
    • /
    • pp.157-165
    • /
    • 2023
  • Seafood is a major source of protein in many countries and its consumption is increasing. In Korea, consumption of seafood is increasing, but self-sufficiency rate is decreasing, and the importance of safety management is increasing as the amount of imported seafood increases. There are hundreds of species of aquatic products imported into Korea from over 110 countries, and there is a limit to relying only on the experience of inspectors for safety management of imported aquatic products. Based on the data, a model that can predict the customs inspection results of imported aquatic products is developed, and a machine learning classification model that determines the non-conformity of aquatic products when an import declaration is submitted is created. As a result of customs inspection of imported marine products, the nonconformity rate is less than 1%, which is very low imbalanced data. Therefore, a sampling method that can complement these characteristics was comparatively studied, and a preprocessing method that can interpret the classification result was applied. Among various machine learning-based classification models, Random Forest and XGBoost showed good performance. The model that predicts both compliance and non-conformance well as a result of the clearance inspection is the basic random forest model to which ADASYN and one-hot encoding are applied, and has an accuracy of 99.88%, precision of 99.87%, recall of 99.89%, and AUC of 99.88%. XGBoost is the most stable model with all indicators exceeding 90% regardless of oversampling and encoding type.

The Comparative Analysis Study and Usability Assessment of Fat Suppressed 3D T2* weighted Technique and Fat Suppressed 3D SPGR Technique when Examining MRI for Knee Joint Cartilage Assesment (슬관절 연골 평가를 위한 자기공명영상 검사 시 지방 신호 억제 3D T2* Weighted 기법과 지방 신호 억제 3D SPGR 기법의 비교 및 유용성 평가)

  • Kang, Sung-Jin
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.6
    • /
    • pp.219-225
    • /
    • 2016
  • In this study, for assessment of degenerative knee joint cartilage disease we acquired images by fat suppressed 3D spoiled gradient recalled (SPGR) and fat suppressed 3D $T2^*$ weighted imaging techniques. To do a quantitative evaluation, the knee joint cartilage was divided into medial femoral cartilage (MFC), medial tibial cartilage (MTC), lateral femoral cartilage (LFC), lateral femoral cartilage (LFC) and patella cartilage (Pat) to measure their respective signal intensity values, signal-to-noise ratio, and contrast-to-noise ratio. As for the measured values, statistical significance between two techniques was verified by using Mann-Whitney U-Test. To do a qualitative evaluation, two radiologists have examined images by techniques after which image artifact, cartilage surface, tissue contrast, and depiction of lesion distinguishing were evaluated based on 4-point scaling (1: bad, 2: appropriate, 3: good, 4: excellent), and based on the result, statistical significance was verified by using Kappa-value Test. 3.0T MR system and HD T/R 8ch knee array coil were used to acquire images. As a result of a quantitative analysis, based on SNR values measured by using two imaging techniques, MFC, LFC, LTC, and Pat showed statistical significance (p < 0.05), but MTC did not (p > 0.05). As a result of verifying statistical significance for measured CNR value, MFC, LFC, and Pat showed statistical significance (p < 0.05), while MTC and LTC did not show statistical significance (p > 0.05). As a result of a qualitative analysis, by comparing mean values for evaluated image items, 3D $T2^*$ weighted Image has indicated a slightly higher value. As for conformance verification between the two observers by using Kappa-value test, all evaluated items have indicated statistically significant results (p < 0.05). 3D $T2^*$ weighted technique holds a clinical value equal to or superior to 3D SPGR technique with respect to evaluating images, such as distinguishing knee joint cartilages, comparing nearby tissues contrast, and distinguishing lesions.