• Title/Summary/Keyword: confocal scanning

Search Result 395, Processing Time 0.022 seconds

Flow Visualization of Blood Cell and Detection of Cell Depleted Layer Using a Confocal Laser Scanning Microscope (공초점 레이저 주사 현미경을 이용한 혈구 유동가시화 및 세포공핍층 측정에 관한 연구)

  • Lim, Soo-Hee;Kim, Wi-Han;Lee, Ho;Lee, Choon-Young;Park, Cheol-Woo
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.1
    • /
    • pp.46-52
    • /
    • 2010
  • In the present study, we employed the confocal laser scanning microscopy (CLSM) system to visualize the blood flow field with $1{\times}1{\mu}m^2$ spatial resolution. Based on the confocal microscopic image of red blood cells (RBCs), we performed the velocity vector field measurement and evaluated characteristics of cell migration from the cell depleted layer thickness calculation. The rat and mouse's blood were supplied into a micro glass tubes in vitro. The line scanning rate of confocal microscopy was 15 kHz for a $500{\times}500$ pixels image. As a result, the red blood cell itself can be used as a tracer directly without any kind of invasive tracer particle to get the velocity vector field of blood flow by performing particle image velocimetry (PIV) technique.

Surface profiling by the phase shifting method in fiber-optical confocal scanning interference microscopes (광섬유 공초점 간섭 현미경과 위상 변위법을 결합한 표면 검색)

  • 김대찬;이승걸
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.3
    • /
    • pp.201-207
    • /
    • 1999
  • The fiber-optical confocal scanning interference microscope with a simple configuration was constructed with a 4-port fiber-optic coupler, and the new method based on the phase shifting method was proposed for surface profiling by the system. In the method, the height of a specimen was determined from the phase of confocal beam. It was verified experimentally that the method was applicable to even the confocal interference microscope with a long-wavelength source and a low NA objective, and that the scanning time could be drastically reduced compared with the conventional method. Finally, it was found that our method is less sensitive to the variation of surface reflectivity than the conventional method.

  • PDF

QUANTITATIVE ANALYSIS OF MINERAL CHANCE IN THE INITIAL CAR10US LESION USING CONFORMAL LASER SCANNING MICROSCOPY (공초점 레이저 주사 현미경을 이용한 법랑질 초기 우식 재광화의 정량적 분석)

  • 차승우;윤태철;박성호;이찬영;금기연
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • Dental Caries which has high prevalence rate, accounts for majority of dental diseases. Many treatment and preventive treatment has been developed, thereby reducing the prevalence rate, but in our country, fluoridization has not spread widely yet, so prevention has not been done satisfactorily. When dental caries progresses, irreversible damage of tooth structure occurs. In initial dental caries, demineralizing tooth structure can be remineralized, so restorative treatment is unnecessary. In this study, 20 teeth restored with composite resin without fluoride release were used and divided into two groups. Incipient dental caries were artificially made and demineralization procedure was done for 1 and 2 weeks, for each group. Changes in mineral contents around the margins were analysed with confocal laser scanning microscope. The results were as follow. 1. Both total fluorescence of the lesion and average fluorescence of the lesion of remineralized samples decreased compared to demineralizing state. (p<0.01) 2. Confocal laser scanning microscopy can be used in quantitative analysis of mineral change. In result, confocal laser scanning microscopy can be used in quantitative analysis of mineral change and it could be used in many different fields of dentistry in the future.

  • PDF

STUDY OF INCIPIENT ENAMEL CARIES USING A DIGITAL ILLUMINATION FIBER-OPTIC TRANSILLUMINATION AND CONFOCAL LASER SCANNING MICROSCOPE (Digital Imaging Fiber-Optic Trans-Illuminational과 Confocal Laser Scanning Microscope를 이용한 초기 법랑질 우식증 연구)

  • Kim, Jae-Tae;Kim, Seung-Oh;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • The purpose of this study were to evaluate the efficacy of the newly developed Digital Imaging Fiber-Optic Trans-illumination (DIFOTI) system in detecting carious lesions in vivo as gold standard with confocal laser scanning microscopy and compared the efficacy of traditional radiography and DIFOTI system in vito as gold standard with confocal laser scanning microscopy, too. For the in vivo study, the subject pool consisted of 23 grammar school age patients just prior to entering the mixed dentition phase Each patient was given a DIFOTI examination of the anterior and posterior teeth. During $6{\sim}8$ months, the naturally expire primary teeth were collected and the efficacy of DIFOTI system was compared with confocal laser scanning microscopy. For in vitro study, 40 primary teeth were collected and decalcified by Carbopol decalcification solution for 1, 2, 4 and 8 days. Every experiment period, all teeth were DIFOTI examined and sectioned to take an image of confocal laser scanning microscopy Sensitivity and specificity were calculated from the result of DIFOTI examine and confocal laser scanning microscopy analysis. The results are as follows : 1. From the in vivo study, the sensitivity of DIFOTI examine was 0. 61 and specificity was 0.63. 2. From the in vivo study, the sensitivity of DIFOTI examine was 0.71 and specificity was 0.75.

  • PDF

Confocal Scanning Microscopy with Multiple Optical Probes for High Speed 3D Measurements and Color Imaging (고속 3차원 측정 및 칼라 이미징을 위한 다중 광탐침 공초점 주사 현미경)

  • Chun, Wan-Hee;Lee, Seung-Woo;Ahn, Jin-Woo;Gweon, Dae-Gab
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.1
    • /
    • pp.11-16
    • /
    • 2008
  • Confocal scanning microscopy is a widely used technique for three dimensional measurements because it is characterized by high resolution, high SNR and depth discrimination. Generally an image is generated by moving one optical probe that satisfies the confocal condition on the specimen. Measurement speed is limited by movement speed of the optical probe; scanning speed. To improve measurement speed we increase the number of optical probes. Specimen region to scan is divided by optical probes. Multi-point information each optical probe points to can be obtained simultaneously. Therefore image acquisition speed is increased in proportion to the number of optical probes. And multiple optical probes from red, green and blue laser sources can be used for color imaging and image quality, i.e., contrast, is improved by adding color information by this way. To conclude, this technique contributes to the improvement of measurement speed and image quality.

  • PDF

New Measurement of Whitening Effects by Using Confocal Scanning Laser Microscope (CSLM) (Confocal Scanning Laser Microscope (CSLM)을 이용한 신규 미백 효과 측정 연구)

  • Kim, Myong Ki;Cho, Seok-Cheol;Nam, Gaewon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.3
    • /
    • pp.279-285
    • /
    • 2015
  • Hyperpigmentation on face is a highly anxiety-producing symptom, especially for women from the aspect of beauty. Pigmentation of the skin is related to the amount of melanin that provides protection against UV radiation. In vivo reflectance confocal microscopy is a non-invasive imaging tool allowing visualization of the skin without tissue alteration, by placing a microscopy directly on the living skin. The aim of this study was to develop the new evaluation method of whitening effects using in vivo reflectance confocal microscopy and to validate other instruments for measuring skin colors, and UV-induced hyperpigmentation was elicited on the inside skin of the forearm. It suggested that the new method for whitening effects using the confocal microscopy was useful to evaluate the de-pigmentation products and to easy for understanding to customers.

The Development of Confocal Microscopy Using the Amplified Double-compound Flexure Guide (레버 증폭 구조의 플렉서를 이용한 공초점 현미경의 개발)

  • Lee, Sang-Won;Kim, Wi-Han;Jung, Young-Dae;Park, Min-Kyu;Kim, Jee-Hyun;Lee, Sang-In;Lee, Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.1
    • /
    • pp.46-52
    • /
    • 2011
  • A confocal microscope was developed utilizing a scanning sample stage based on a home-built double-compound flexure guide. A scanning sample stage with nano-scale resolution consisted of a double leaf spring based flexure, a displacement amplifying lever, a Piezo-electric Transducer(PZT) actuator and capacitance sensors. The performance of the two-axis stage was analyzed using a commercial finite element method program prior to the implementation. A single line laser was employed as the light source along with the Photo Multiplier Tube(PMT) that served as the detector. The performance of the developed confocal microscope was evaluated with a mouse ear skin imaging test. The designed scanning stage enabled us to build the confocal microscope without the two optical scanning mirror modules that are essential in the conventional laser scanning confocal microscope. The elimination of the scanning mirror modules makes the optical design of the confocal microscope simpler and more compact than the conventional system.

Fiber Orientation in Injection-Molded Short Fiber Composites with a Confocal Laser Scanning Microscope and Numerical Simulation (공초점 레이저 주사 현미경을 이용한 단섬유 복합재료 사출 성형물 내의 섬유 배열 측정 및 수치모사)

  • Lee, Kwang-Seok;Le, Seok-Won;Youn, Jae-Ryoun
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.201-204
    • /
    • 2001
  • A Confocal Laser Scanning Microscope (CLSM) is applied to determine three-dimensional fiber orientation states in injection-molded short fiber composites. Since the CLSM optically sections the composites, more than two planes either on or below the surface of composites can be obtained. Therefore, three dimensional fiber orientation states are determined without destruction. To predict the orientation states, velocity and temperature fields are calculated by using a hybrid FEM/FDM method. The change of orientation state during packing stage is also considered by employing a compressible Hele-Shaw model. The predicted orientation states show good agreement with measured ones. However, some differences are found at the end of cavity. They may result from other effects, which are not considered in the numerical analysis.

  • PDF

Scanning confocal microscope of a surface following effect using a quad-detector (4분할 광검출기를 이용한 표면 추적 효과의 공초점 현미경)

  • 김수철;송장섭;권남익
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.1
    • /
    • pp.1-4
    • /
    • 1998
  • A compact scanning confocal microscope has been constructed using a quad-detector in a CD-player. The variation of error signal on depth which obtained by a quad-detector is used in the scanning confocal microscope. Bipolar error signals, which is sensitive near a focus, give a surface following effect whiout following the surface. In the case of small depth difference, the difference of materials through the reflection signal has been identified. The image which uses reflection signal only, has been obtained with the same setup. And, the results obtained in two different way were compared and analyzed.

  • PDF