Microscopic Studies and Simulations of Bloch Walls in Nematic Thin Films

  • Park, Jung-Ok;Zhou, Jian;Srinivasarao, Mohan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.493-495
    • /
    • 2005
  • The director profiles of the Bloch walls are directly visualized using fluorescence confocal polarizing microscopy. Both pure twist Bloch walls and diffuse Bloch walls are analyzed. Polar anchoring energy was measured from optical simulation of the transmitted light interference pattern or the fluorescence intensity profile of a pure twist wall..

  • PDF

Study for comparison with male & female rat locus coeruleus using confocal laser scanning microscopy (공초점현미경을 이용한 암수 흰쥐 청색반점의 비교연구)

  • Park, Il-kwon;Song, Chi-won;Lee, Kyung-youl;Kwon, Hyo-jung;Kim, Moo-kang;Lee, Kang-iee;Jeong, Young-gil;Lee, Nam-seob;Ha, Kwon-soo
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.3
    • /
    • pp.451-461
    • /
    • 2000
  • The locus coeruleus(LG) is known to be observed a sexual dimorphism in rat CNS. LC is the largest collections of norepinephrine(NE)-containing neurons in the mammalian brain. Especially in rat, all LC neurons contained NE unlike other mammalians, so that specific reactions were found in the tyrosine-hydroxylase(TH) immunoreactive neurons. Sexual dimorphism of rat LC has affected by genes before sex hormone appeared, thereafter affected by sex hormones. In these day, many scientists founded morphological differences between male and female LC morphology, but differences of entire structure was not founded. Thus we investigated sex differences of the LC neuron's morphology in rat by three-dimensional(3-D) reconstruction using Confocal laser scanning microscopy(CLSM). We reported that neuron's shape was relatively-large multipolar neurons and neuron's processes in dorsal LC proceeded to ventral direction in the male and female rat. Male had a longer anterior-posterior length than female had in dorsal LC. In addition to middle-LC, male rat's LC had a more thicker posterior region but had not viewed in a previous study. In reverse, female rat's LC had a thicker anterior region like a previous study. This results using 3-D reconstruction by CLSM showed that the male's LC was more wide-ranging than female's relatively.

  • PDF

Investigation of Bordered Pit Ultrastructure in Tracheid of Korean Red Pine (Pinus densiflora) by Confocal Reflection Microscopy (공초점반사현미경을 이용한 소나무 유연벽공의 초미세구조 연구)

  • Kwon, Ohkyung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.346-355
    • /
    • 2014
  • Confocal reflection microscopy (CRM) was utilized to create 3-dimensional images of bordered pits and cell wall in the tracheid of Korean red pine (Pinus densiflora). Ultrastructures of torus, margo, and pit border were clearly observable in the CRM micrograph. Micrograph of cross-field pit revealed the connecting and supporting structure between tracheid and ray parenchyma cell. The CRM micrographs enabled to investigate detailed structures of tracheid cell wall such as S1, S2, S3 layers, transition layers between these layers, and microfibril (MF) orientation in S3 and S2 layers as well as complicated distribution of MF orientation around bordered pits. Not only concentric MF orientation of border thickening in the pit border was observed, but also changes in MF orientation from the cell wall to the border. From the experimental results, the CRM was thought to be a versatile microtechnique to investigate detailed structures of cell wall and bordered pit in the tracheid and cross-field pit between tracheid and ray parenchyma cell.

Enhancement of Immunomodulatory and Anticancer Activity of Fucoidan by Nano Encapsulation

  • Qadir, Syed Abdul;Kwon, Min-Chul;Han, Jae-Gun;Ha, Ji-Hye;Jin, Ling;Jeong, Hyang-Suk;Kim, Jin-Chul;You, Sang-Guan;Lee, Hyeon-Yong
    • Food Science and Biotechnology
    • /
    • v.17 no.6
    • /
    • pp.1254-1260
    • /
    • 2008
  • The aim of the present study was to prepare nanosample of fucoidan using lecithin as encapsulated material and to investigate the anticancer and immunomodulatory activity of nanoparticle in vitro. The nanoparticles have been characterized by dynamic light scattering (DLS) and transmission electron microscopy (TEM). Confocal microscopy confirmed the internalization of the fucoidan conjugates into the immune cells. The uptake of nanoparticles was confirmed with confocal microscopy demonstrating their localization in the cells. The anticancer activity was increased over 5-10% in different cancer cells of fucoidan nanoparticle as compare with fucoidan. The human B and T cells growth and the secretion of interleukin-6 and tumor necrosis factor-a from B cell were also improved by fucoidan nanoparticle because of the rapid absorption of nanoparticle into the cells as compare to fucoidan. At 0.6 mg/mL concentrations, the fucoidan nanoparticle showed better activity than 1.0 mg/mL concentration in T cell growth because the cells reached their saturation capacity. When the fucoidan was encapsulated in lecithin, its anticancer as well as its immunomodulatory activity proved to be superior from that of itself in pure form.

Surface alterations following instrumentation with a nylon or metal brush evaluated with confocal microscopy

  • Kim, Young-Sung;Park, Jun-Beom;Ko, Youngkyung
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.5
    • /
    • pp.310-318
    • /
    • 2019
  • Purpose: Surface alterations of titanium discs following instrumentation with either a nylon brush or a metal brush were evaluated. Methods: A total of 27 titanium discs with 3 surface types (9 discs for each type), including machined (M) surfaces, sandblasted and acid-etched (SA) surfaces, and surfaces treated by resorbable blast media (RBM), were used. Three discs were instrumented with a nylon brush, another 3 discs were instrumented with a metal brush, and the remaining 3 discs were used as controls for each surface type. Surface properties including the arithmetic mean value of a linear profile (Ra), maximum height of a linear profile (Rz), skewness of the assessed linear profile (Rsk), arithmetic mean height of a surface (Sa), maximum height of a surface (Sz), developed interfacial area ratio (Sdr), skewness of a surface profile (Ssk), and kurtosis of a surface profile (Sku) were measured using confocal microscopy. Results: Instrumentation with the nylon brush increased the Ra, Sa, and Sdr of the M surfaces. On the SA surfaces, Ra, Sa and Sdr decreased after nylon brush use. Meanwhile, the roughness of the RBM surface was not affected by the nylon brush. The use of the metal brush also increased the Ra, Sa, and Sdr of the M surface; however, the increase in Sdr was not statistically significant (P=0.119). The decreases in the Rz, Sz, Ra, Sa, and Sdr of the SA surfaces were remarkable. On the RBM surfaces, the use of the metal brush did not cause changes in Ra and Sa, whereas Rz, Sz, and Sdr were reduced. Conclusions: Titanium surfaces were altered when instrumented either with a nylon brush or a metal brush. Hence, it is recommended that nylon or metal brushes be used with caution in order to avoid damaging the implant fixture/abutment surface.

Influence of access cavity design on calcium hydroxide removal using different cleaning protocols: a confocal laser scanning microscopy study

  • Seda Falakaloglu;Merve Yeniceri Ozata;Betul Gunes;Emmanuel Joao Nogueira Leal Silva;Mustafa Gundogar;Burcu Gucyetmez Topal
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.3
    • /
    • pp.25.1-25.13
    • /
    • 2023
  • Objectives: The purpose of this study was to evaluate the influence of endodontic access cavities design on the removal of calcium hydroxide medication of the apical third of mandibular incisor root canal walls and dentinal tubules with different cleaning protocols: EDDY sonic activation, Er,Cr:YSGG laser-activated irrigation, or conventional irrigation with IrriFlex. Materials and Methods: Seventy-eight extracted human mandibular incisors were assigned to 6 experimental groups (n = 13) according to the endodontic access cavity and cleaning protocol for calcium hydroxide removal: traditional access cavity (TradAC)/EDDY; ultraconservative access cavity performed in the incisal edge (UltraAC.Inc)/EDDY; TradAC/Er,Cr:YSGG; UltraAC. Inc/Er,Cr:YSGG; TradAC/IrriFlex; or UltraAC.Inc/IrriFlex. Confocal laser scanning microscopy images were used to measure the non-penetration percentage, maximum residual calcium hydroxide penetration depth, and penetration area at 2 and 4 mm from the apex. Data were statistically analyzed using Shapiro-Wilk and WRS2 package for 2-way comparison of non-normally distributed parameters (depth of penetration, area of penetration, and percentage of non-penetration) according to cavity and cleaning protocol with the significance level set at 5%. Results: The effect of cavity and cleaning protocol interactions on penetration depth, penetration area and non-penetration percentage was not found statistically significant at 2 and 4 mm levels (p > 0.05). Conclusions: The present study demonstrated that TradAC or UltraAC.Inc preparations with different cleaning protocols in extracted mandibular incisors did not influence the remaining calcium hydroxide at 2 and 4 mm from the apex.

The Development of Confocal Microscopy Using the Amplified Double-compound Flexure Guide (레버 증폭 구조의 플렉서를 이용한 공초점 현미경의 개발)

  • Lee, Sang-Won;Kim, Wi-Han;Jung, Young-Dae;Park, Min-Kyu;Kim, Jee-Hyun;Lee, Sang-In;Lee, Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.1
    • /
    • pp.46-52
    • /
    • 2011
  • A confocal microscope was developed utilizing a scanning sample stage based on a home-built double-compound flexure guide. A scanning sample stage with nano-scale resolution consisted of a double leaf spring based flexure, a displacement amplifying lever, a Piezo-electric Transducer(PZT) actuator and capacitance sensors. The performance of the two-axis stage was analyzed using a commercial finite element method program prior to the implementation. A single line laser was employed as the light source along with the Photo Multiplier Tube(PMT) that served as the detector. The performance of the developed confocal microscope was evaluated with a mouse ear skin imaging test. The designed scanning stage enabled us to build the confocal microscope without the two optical scanning mirror modules that are essential in the conventional laser scanning confocal microscope. The elimination of the scanning mirror modules makes the optical design of the confocal microscope simpler and more compact than the conventional system.