• 제목/요약/키워드: confined system

검색결과 388건 처리시간 0.034초

Evaluation of Dry Matter Intake and Average Daily Gain Predicted by the Cornell Net Carbohydrate and Protein System in Crossbred Growing Bulls Kept in a Traditionally Confined Feeding System in China

  • Du, Jinping;Liang, Yi;Xin, Hangshu;Xue, Feng;Zhao, Jinshi;Ren, Liping;Meng, Qingxiang
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제23권11호
    • /
    • pp.1445-1454
    • /
    • 2010
  • Two separate animal trials were conducted to evaluate the coincidence of dry matter intake (DMI) and average daily gain (ADG) predicted by the Cornell Net Carbohydrate and Protein System (CNCPS) and observed actually in crossbred growing bulls kept in a traditionally confined feeding system in China. In Trial 1, 45 growing Simmental${\times}$Mongolia crossbred F1 bulls were assigned to three treatments (T1-3) with 15 animals in each treatment. Trial 2 was conducted with 60 Limousin${\times}$Fuzhou crossbred F2 bulls allocated to 4 treatments (t1-4). All of the animals were confined in individual stalls. DMI and ADG for each bull were measured as a mean of each treatment. All of the data about animals, environment, management and feeds required by the CNCPS model were collected, and model predictions were generated for animals on each treatment. Subsequently, model-predicted DMI and ADG were compared with the actually recorded results. In the three treatments in Trial 1, 93.3, 80.0 and 73.3% of points fell within the range from -0.4 to 0.4 kg/d for DMI mean bias; similarly, in the four treatments in Trial 2, about 86.7, 73.3, 73.3 and 80.0% of points fell within the same range. These results indicate that the CNCPS model can accurately predict DMI of crossbred bulls in the traditionally confined feeding system in China. There were no significant differences between predicted and observed ADG for T1 (p = 0.06) and T2 (p = 0.09) in Trial 1, and for t1 (p = 0.07), t2 (p = 0.14) and t4 (p = 0.83) in Trial 2. However, significant differences between predicted and observed ADG values were observed for T3 in Trial 1 (p<0.01) and for t3 in Trial 2 (p = 0.04). By regression analysis, a statistically different value of intercept from zero for the regression equation of DMI (p<0.01) or an identical value of ADG (p = 0.06) were obtained, whereas the slopes were significantly different (p<0.01) from unity for both DMI and ADG. Additionally, small root mean square error (RMSE) values were obtained for the unbiased estimator of the two variances (DMI and ADG). Thus, the present results indicated that the CNCPS model can give acceptable estimates of DMI and ADG of crossbred growing bulls kept in a traditionally confined feeding system in China.

소방공무원의 비화재 밀폐공간 구조·구급 활동 중 질식 및 중독재해 사례 분석 (Fire fighters' Asphyxiation Incidents during Confined Space Rescue in Korea)

  • 이주희;강태선
    • 한국산업보건학회지
    • /
    • 제29권4호
    • /
    • pp.590-602
    • /
    • 2019
  • Objectives: This study was conducted to prevent asphyxiation of firefighters during confined space rescue. The specific purpose was to identify the magnitude of the problem, identify the cause of the accidents, and suggest measures to ensure safety of confined space rescues. Methods: We collected data from National Fallen Firefighters Memorial, press releases, and other sources In order to identify the current situation of asphyxiation incidents among firefighters from 1945 to 2019. In addition, an incident investigation was conducted for each case, and the processes, causes, and control measures of the incidents were described as a narrative data entry. Results: Over the past 73 years, eight incidents involving firefighter in Korea have occurred. In these incidents, five firefighters were killed, and eight were injured. The confined spaces incidents occurred were water supply tanks, wastewater treatment tanks, pickling pits, septic tanks, and more. The causes were three cases of hydrogen sulfide poisoning, one of oxygen deficiency, one of carbon monoxide poisoning, and three unclassifiable asphyxiations. The people in need were all workers in various industries. Conclusions: The number of firefighters' deaths and injuries during rescues in confined spaces was severe and the risks have not been completely eliminated. By establishing and implementing a precise incident investigation system, according control measures should be initiatedin order to prevent a recurrence of the same type of disaster and reflected in the SOP. In particular, due to the high risk of occurrence at workplaces, cooperation between fire and rescue authority and relevant agencies such as the Ministry of Employment and Labor and the KOSHA should be strengthened.

NEUTRON SCATTERING INVESTIGATIONS OF PROTON DYNAMICS OF WATER AND HYDROXYL SPECIES IN CONFINED GEOMETRIES

  • Chen, S.H.;Loong, C.K.
    • Nuclear Engineering and Technology
    • /
    • 제38권3호
    • /
    • pp.201-210
    • /
    • 2006
  • This article presents a brief overview of an important area of neutron scattering: the general principles and techniques of elastic, quasielastic and inelastic scattering from a system composed predominately of incoherent scatterers. The methodology is then applied to the study of water, specifically when it is confined in nanometer-scale environments. The confined water exhibits uniquely anomalous properties in the supercooled state. It also nourishes biological functions, and supports essential chemical reactions in living systems. We focus on recent investigations of water encapsulated in nanoporous silica and carbon nanotubes, hydrated water in proteins and water or hydroxyl species incorporated in nanostructured minerals. Through these scientific examples, we demonstrate the advantages derived from the high sensitivity of incoherent neutron spectroscopy to hydrogen atom motions and hydrogen-bond dynamics, aided by rigorous data interpretation method using molecular dynamics simulations or theoretical modelling. This enables us to probe the inter-/intramolecular vibrations and relaxation/diffusion processes of water molecules in a complex environment.

횡구속 콘크리트의 압축 응력-변형률 모델 : Part II. 사각단면 부재 (Stress-Strain Model for Laterally Confined Concrete : Part II. Rectangular Sectional Members)

  • 선창호;정혁창;김익현
    • 한국지진공학회논문집
    • /
    • 제21권1호
    • /
    • pp.59-67
    • /
    • 2017
  • Due to a lack of the hoop action of lateral reinforcements the effective confining force in rectangular sections reduces compared to circular ones. Therefore, the stress-strain model obtained from the experimental data with circular sections overestimates the lateral confinement effect in rectangular sections, which evaluates seismic safety margin of overall structural system excessively. In this study experiments with laterally-confined square sections have been performed and the characteristic values composing stress-strain model have been analyzed. With introduction of section coefficients, in addition, the new unified stress-strain model applicable to square sections as well as circular ones has been proposed.

주변이 RC로 구속된 조적조 벽체의 내진성능향상에 관한 실험적 연구 (Experimental Study for Higher Seismic Performance of Confined Masonry Wall System)

  • 김경태;서수연;윤승조;요시무라코지;성기태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.5-8
    • /
    • 2004
  • In order to investigate the effect of the height of application point of lateral loads and reinforcing steel bars in walls and columns in improving the seismic behavior of confined concrete block masonry walls, an experimental research program is conducted. A total of four one-half scale specimens are tested under repeated lateral loads. Specimens are tested to failure with increasing maximum lateral drifts while a vertical axial load was applied and maintained constant. The constant vertical axial stresses applied are 0, 0.84 and 1.80MPa, while the amount of reinforcements in horizontal and vertical directions are $0\%,\;0.08\%\;and\;0.18\%$ respectively. Test results obtained for each specimen include cracking patterns, load-deflection data, and strains in reinforcement and walls in critical locations. Analysis of test data showed that above parameters generate a considerable effect on the seismic performance of confined concrete block masonry walls.

  • PDF

MMG 모델을 이용한 제한수로를 운항하는 선박의 침로안정성능 추정에 관한 연구 (A Study on Estimation of the Course Keeping Ability of a Ship in Confined Waterways Using the MMG Model)

  • 김현철;김인태;김상현;권수연
    • 한국항해항만학회지
    • /
    • 제43권6호
    • /
    • pp.369-376
    • /
    • 2019
  • 선박이 제한수로를 운항할 때에는 기존 심수 및 천수 중을 운항하는 선박의 조종특성과 일반적으로 다르기 때문에 선박의 안전한 항해를 위해 달라지는 선박의 조종특성 추정이 중요하다. 본 연구에서는 제한수로를 운항하는 선박의 조종성능을 추정하기 위해 조종운동 방정식과 가상 구속모형시험 시뮬레이션을 통한 유체력 미계수를 이용하여 조종성능을 추정하였다. 조종 수학 모델 중 선체, 프로펠러, 타를 분리하여 유체력을 모델링하는 방식인 모듈형(modular type) 모델에 제한수로의 영향을 고려하는 항을 추가하여 제한수로 중 조종성능을 추정 연구를 수행하였다. 제한수로 중 선체에 작용하는 유체력 미계수를 도출하기 위하여 상용 CFD 프로그램을 이용한 가상 구속모형시험 시뮬레이션을 수행하였다. 최종적으로 제한수로 중 직진 시뮬레이션과 Zig-zag 시뮬레이션을 수행하여 제한수로의 영향이 고려된 조종 시뮬레이션을 수행하였다. 특히 선박의 침로 안정성능을 평가하기 위해 Zig-zag 시험을 수행하는데, 측벽으로 인한 선박 주위의 비대칭 유동이 좌현과 우현에 압력차이를 발생시켜 선박의 궤적에 큰 영향을 미침을 확인하였다.

Better Housing for Effective Pig Production - Review -

  • Choi, H.L.;Song, J.I.;An, H.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제12권8호
    • /
    • pp.1310-1315
    • /
    • 1999
  • Air quality in confinement pig houses is important to production and health. Mechanical ventilation and confinement is known to be the most practical tool for maintaining adequate air quality in pig houses through extensive researches since Millier (1950) invented the 'slotted inlet' ventilation system. A variety of mechanical ventilation systems have been applied to confined nursery pig houses in Korea without scientific verification of their ventilation effectiveness. Ventilation systems with three feasible combinations (NA, NB, and NC) of inlets and outlets in a confined nursery pig house were tested to evaluate their ventilation efficiency, of which the one with the performance was supposed to be taken as a standard ventilation system for nursery pig houses in Korea. Field data of air velocity and temperature fields, and ammonia concentration with three ventilation systems were taken and compared to determine the best system. The air velocity and temperature fields predicted by the PHOENICS computer program were also validated against the available experimental data to investigate the feasibility of computer simulation of air and temperature distribution with an acceptable accuracy in a confined house. NC system with duct-induced in-coming air, performed best among the three different ventilation systems, which created higher velocity field and evener distribution ($2.5m/s{\pm}0.3m/s$) over the space with a Reynolds number of $10^4$. The experimental data obtained also fitted well with the simulated values using the modified PHOENICS, which suggested a viable tool for the prediction of air and temperature field with given calculation geometries.

Acridine Fluorescence Behaviors in Different Polymeric Microenvironments Directed by C2-Proton-Acidity of Imidazolium-Based Ionic Liquids

  • Ji, Myoung-Jin;Kim, Jong-Gyu;Shin, Ueon-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권8호
    • /
    • pp.2489-2493
    • /
    • 2012
  • A new fluorescent system (acridine/RTIL hybrid gel) confined in the 3D micro-structure of a poly(lactic acid) membrane were prepared from 1-butyl-3-methylimidazolium-based ionic liquids ([bmim]X (X = $SbF_6$, $NTf_2$, Cl); RTILs), poly(lactic acid) (PLA), and acridine via the sol-gel route. SEM images showed that, in the presence of [bmim]$SbF_6$ and [bmim]$NTf_2$, 3D-ly paticulated structures were created inside the PLA membranes and acridine/RTIL hybrid gels were confined in gabs of particulates. However, the use of [bmim]Cl induced the formation of a 3D-ly porous structure containing the hybrid gel of acridine/[bmimCl in the micropores. The three fluorescent systems exhibited different fluorescence behaviors (fluorescence maximum and intensity) depending on the C2-H acidity scale of the RTILs (or their anion type). Acridine gels hybridized with [bmim]$SbF_6$ and [bmim]$NTf_2$ showed blue fluorescence with relative high intensity, whereas the hybrid gel with [bmim]Cl exhibited almost no fluorescence under dry conditions. However, the acridine/[bmim]Cl hybrid system in the micro-porous PLA membrane started to emit fluorescent light under humid conditions and showed a possible response, indicating that it could be applied as a humidity sensor.

Design of Rule-based Inference Engine for the Monitoring of Harmful Environments in Workplace

  • 안윤애
    • 한국산업정보학회논문지
    • /
    • 제14권4호
    • /
    • pp.65-74
    • /
    • 2009
  • 맨홀, 지하정화조, 저장탱크, 밀폐공간 등의 유해 작업장은 환기가 불충분한 상태에서 산소결핍, 유해가스로 인한 건강장해와 인화성 물질에 의한 화재, 폭발 등의 위험이 있다. 이와 같은 유해환경 정보를 작업장 내의 센서를 통해서 실시간으로 모니터링하고, 위험으로부터 작업자의 안전을 보장할 수 있는 시스템이 필요하다. 이 논문에서는 작업장의 유해환경을 모니터링하기 위한 추론엔진을 설계한다. 제안하는 추론엔진은 규칙기반 시스템의 구조를 가지며 JESS를 활용한다. 제안 시스템은 특정 컴퓨팅 플랫폼에 제약되지 않으며 OSGi 기반의 미들웨어와 연동이 쉬운 특징을 가진다.